• 제목/요약/키워드: differential probe

검색결과 93건 처리시간 0.025초

Identification of Genes Induced by Low Temperature in Rice

  • Choi, Kyong-Hee;Choi, Hack-Sun;Lee, Choon-Hwan;Kwon, Young-Myung;Rhew, Tae-Hyong
    • BMB Reports
    • /
    • 제30권4호
    • /
    • pp.292-295
    • /
    • 1997
  • Exposure of seedling of rice (Oriza sativa cv.Dongin) to cold stress ($6^{circ}C$, 7day) induced differential gene expression. Differentially expressed polyadenylated RNA induced by low temperature were isolated and identified from the leaves of rice (Oriza sativa cv.Dongin) seedling by using the technique, differential display of reverse transcription through polymerase chain reaction (DDRT-PCR). Four bands of cDNAs were differentially displayed on the PAGE gel through DDRT-PCR, and among them three bands were those of overexpressed genes while one band was of an underexpressed gene One of the overexpressed cDNA was characterized. The size of the DDRT-PCR product was found to be about 200 bp. The sequence of the cloned DNA was compared with those of GenBank through a BLAST E-Mail server, and it was found to have no homologies in the nucleotide sequence with that of any known DNA: therefore, it was designated as RC101 The expression of the cold-stress induced-gene, RC101, was sustained with Northern Blot analysis by using the cloned DDRT-PCR product as a probe.

  • PDF

초정밀 안내면 레일의 평행도 및 진직도 동시측정 (Parallelism and Straightness Measurement of a Pair of Rails for Ultra Precision Guide-ways)

  • 황주호;박천흥;;김승우
    • 한국정밀공학회지
    • /
    • 제24권3호
    • /
    • pp.117-123
    • /
    • 2007
  • This paper describes a three-probe system that can be used to measure the parallelism and straightness of a pair of rails simultaneously. The parallelism is measured using a modified reversal method, while the straightness is measured using a sequential two-point method. The measurement algorithms were analyzed numerically using a pair of functionally defined rails to validate the three-probe system. Tests were also performed on a pair of straightedge rails with a length of 250 mm and a maximum straightness deviation of $0.05{\mu}m$, as certified by the supplier. The experimental results demonstrated that the parallelism-measurement algorithm had a cancellation effect on the probe stage motion error. They also confirmed that the proposed system could measure the slope of a pair of rails about $0.06{\mu}rad$. Therefore, by combining this technique with a sequential differential method to measure the straightness of the rails simultaneously, the surface profiles could be determined accurately and eliminate the stage error. The measured straightness deviation of each straight edge was less than $0.05{\mu}m$, consistent with the certified value.

신경신호기록용 능동형 반도체미세전극을 위한 CMOS 전치증폭기의 잡음특성 설계방법 (Noise Performance Design of CMOS Preamplifier for the Active Semiconductor Neural Probe)

  • 김경환;김성준
    • 대한의용생체공학회:의공학회지
    • /
    • 제21권5호
    • /
    • pp.477-485
    • /
    • 2000
  • 본 논문에서는 신경신호기록을 위한 반도체 미세전극용 전치증폭기의 잡음특성을 설계하기 위한 체계적인 방법을 제시한다. 세포외기록(extracellular recording)에 의하여 측정된 신경신호와 전형적인 CMOS소자의 저주파 잡음특성을 함계 고려하여 전체 신호대잡음비를 계산하였다. 2단 CMOS 차동증폭기에 대한 해석과 함께 신호대잡음비에 중요한 영향을 끼치는 요소들에 대하여 설명하였다. 출력잡음전력에 대한 해석적인식을 유도하였으며 이로부터 회로설계자가 조절할 수 있는 주파수응답과 소자 파라미터들을 결정하였다. 입력소자의 크기와 트랜스컨덕턴스의 비가 최적영역으로부터 약간 벗어날 경우에 신호대잡음비가 크게 저하됨을 보였다. 이와 함께 만족스런 잡음특성을 위한 증폭이의 설계 변수 값들도 제시하였다.

  • PDF

지지대 부근의 전열관 결함으로 인해 발생되는 보빈 와전류신호의 예측 및 분석 (Prediction and Analysis of Bobbin ECT Signals generated by Tube Defects near Support Plate)

  • 신영길;이윤태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.942-944
    • /
    • 2005
  • In this study, eddy current signals from various anomalous defects in the heat exchanger tube are predicted af their signal slope characteristics no analyzed. The signal changes due to frequency increase are also observed. Based in the accumulated knowledge, the analysis of superimposed signal is attempted which includes the effects of support plate. Both differential and absolute bobbin probe signals are analyzed. For the prediction of signals, axisymmetric finite element modeling is used and this leads us to the utilization of slope angle analysis of the signal. Results show that differential signals are useful to locate the position of defect under the support plate and absolute signals no easy to predict and analyze even though they no superimposed signals. Combined use of these two types of signals will accomplish a reliable inspection.

  • PDF

Solvent-induced Expansion & Shrinkage of Demineralized Dentin Matrix

  • Lee, Kwang-Won
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.580-580
    • /
    • 2001
  • Before resin composites can serve as durable substitutes for amalgam restorations, the adhesive system used to retain them and add to seal dentin must be improved. The recent observations, using the newly developed LVDT (linear variable differential transformer) probe, that all commercial bonding systems cause a collapse of the demineralized dentin matrix, simulated a re-evaluation of the effects of these formulations on the matrix. The experiment was begun by examining solvents such as water-HEMA mixtures. These produced the same shrinkages as did the complete formulations.(omitted)

  • PDF

몽골 유래 Brucella melitensis 동정 및 특이 SNP를 이용한 real-time PCR법에 의한 진단 평가 (Identification of Brucella melitensis isolates originating from Mongolia and diagnostic real-time PCR evaluation using a specific SNP)

  • 강성일;김지연;김숙미;이진주;성소라;김연희;정석찬;허문
    • 대한수의학회지
    • /
    • 제55권2호
    • /
    • pp.105-110
    • /
    • 2015
  • A real-time PCR assay using hybridization probe (HybProbe) has been developed to detect Brucella (B.) melitensis strains. The primer and HybProbe sets were designed based on the gap gene of chromosome I with a specific single nucleotide polymorphism of B. melitensis. Specificity of the assay was confirmed by comparison to reference Brucella species and other related strains. In the melting curve analysis, B. melitensis generated a peak at $67^{\circ}C$ unlike those for other Brucella species observed at $61^{\circ}C$. Sensitivity of the assay for B. melitensis ranged from 20 ng to 200 fg of genomic DNA. The ability to identify 94 Mongolian B. melitensis isolates using the real-time PCR assay was identical to that of classical biotyping methods and differential multiplex PCR. These data showed that this new molecular technique is a simple and quick method for detecting B. melitensis, which will be important for the control and prevention of brucellosis.

Spatial Distributions of Alloying Elements Obtained from Atom Probe Tomography of the Amorphous Ribbon Fe75C11Si2B8Cr4

  • Shin, Jinkyung;Yi, Seonghoon;Pradeep, Konda Gokuldoss;Choi, Pyuck-Pa;Raabe, Dierk
    • 한국재료학회지
    • /
    • 제23권3호
    • /
    • pp.190-193
    • /
    • 2013
  • Spatial distributions of alloying elements of an Fe-based amorphous ribbon with a nominal composition of $Fe_{75}C_{11}Si_2B_8Cr_4$ were analyzed through the atom probe tomography method. The amorphous ribbon was prepared through the melt spinning method. The macroscopic amorphous natures were confirmed using an X-ray diffractometer (XRD) and a differential scanning calorimeter (DSC). Atom Probe (Cameca LEAP 3000X HR) analyses were carried out in pulsed voltage mode at a specimen base temperature of about 60 K, a pulse to base voltage ratio of 15 %, and a pulse frequency of 200 kHz. The target detection rate was set to 5 ions per 1000 pulses. Based on a statistical analyses of the data obtained from the volume of $59{\times}59{\times}33nm^3$, homogeneous distributions of alloying elements in nano-scales were concluded. Even with high carbon and strong carbide forming element contents, nano-scale segregation zones of alloying elements were not detected within the Fe-based amorphous ribbon. However, the existence of small sub-nanometer scale clusters due to short range ordering cannot be completely excluded.

감자로부터 Eukaryotic Translation Initiation Factor 5A (elF-5A) 유전자의 동정 및 발현 분석 (Isolation and Characterization of Eukaryotic Translation Initiation Factor 5A (eIF-5A) from Potato)

  • 인준교;신동호;최관삼;양덕춘
    • 식물조직배양학회지
    • /
    • 제28권5호
    • /
    • pp.283-287
    • /
    • 2001
  • 감자 (Solanum tuberosum L. cv. Irish Cobbler)의 괴경형성과정 (tuberization) 동안에 발현하는 유전자들의 발현양상을 조사하고자 differential display법을 실시하였다. Differential display를 이용하여 분리된 eIF5A DNA단편을 probe로 사용하여 감자의 cDNA library screening을 통하여 eIF5A full-length cDNA를 감자에서 처음으로 분리하였다. 감자의 eIF5A, clone은 토마토의 eIF5A cDNA 염기서열과 94.8%. 아미노산 서열에서는 97.5%로 매우 높은 유사성을 나타내었다. 감자의 eIF5A 유전자는 길이가 716 bp로 하나의 단백질 code영역 (ORF)을 포함하고 있었다. 이 영역은 분자량 17.4 kD, pI 5.5로 추정되는 160개의 아미노산으로 구성된 eIF5A단백질을 code하고 있었다. eIF5A 단백질들에서 12개의 아미노산 서열 (STSKTGKHGHAK)은 효모에서 사람에 이르기까지 완벽하게 보존되어 있는 것으로 알려져 있는데, 감자에서도 또한 잘 보존되어 있었다. 이 영역은 eIF5A 단백질의 활성을 나타내는 데 있어서 필수적인 hypusine을 생성하는 전사 후 수식 부위가 들어 있는 아주 중요한 곳이다. 감자에서 eIF5A 유전자의 발현양상을 조사한 결과 감자의 전조직에서 발현을 보였는데, 성숙잎이나 괴경보다는 세포분열 및 물질축적이 활발히 일어나고 있는 꽃기관들 (stamen, ovary, petal. sepal), 과실 (fruit)과 stolen 등의 조직들에서 비교적 활발히 발현되고 있었다.

  • PDF

자동차 시트용 탄소섬유 발열체의 전기적 및 저항 발열 특성 (Electrical and Resistance Heating Properties of Carbon Fiber Heating Element for Car Seat)

  • 최경은;박찬희;서민강
    • 공업화학
    • /
    • 제27권2호
    • /
    • pp.210-216
    • /
    • 2016
  • 본 연구에서는 무전해 니켈 도금 시간을 달리하여 제조한 자동차 시트용 탄소섬유 발열체의 발열 및 전기적 특성에 관하여 고찰하였다. 무전해 니켈 도금된 탄소섬유의 비저항 및 비열은 4-point probe method 및 differential scanning calorimetry (DSC)를 이용하여 분석하였으며, 표면 형상 및 표면 온도는 scanning electron microscope (SEM) 및 열화상 카메라를 이용하여 관찰하였다. 실험 결과, 도금시간의 증가에 따라 니켈 도금 두께 및 표면 온도는 증가하였으며, 반면에 비열 및 비저항은 도금시간이 증가함에 따라 감소하였다. 결과적으로 무전해 니켈 도금은 자동차 시트용 탄소섬유 발열체의 저항 발열 및 전기적 특성을 크게 향상시키는 것으로 판단된다.

비파괴검사 전용 시뮬레이터를 이용한 와전류검사 신호 시뮬레이션 (Simulation of Eddy Current Testing Signals Using Simulation Software Dedicated to Nondestructive Testing)

  • 이태훈;조찬희;이희종
    • 한국압력기기공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.75-81
    • /
    • 2014
  • A simulation of eddy current testing has been utilized for predicting the signal characteristics to the various defects and developing the probes. Especially, CIVA which is a simulation tool dedicated to nondestructive testing has a good accuracy and speed, and provides a three-dimensional graphical user interface for improved visualization and familiar data displays consistent with NDE technique. Although internal validations have been performed by the CIVA software development specialists, an independent validation study is necessary for the accuracy assessment of the software prior to practical use. For this purpose, in this study, eddy current testing signals of ASME FBH calibration standard tube for bobbin probe were simulated using CIVA and the results were compared to the experimental inspected signals based on the relationship between each flaw signal in terms of amplitude and phase, and the shape of the Lissajous curve. And then we verified the accuracy of the simulated signals and the possible range for simulation. Overall, there is a good qualitative agreement between the CIVA simulated and experimental results in the absolute and differential modes at the two inspection frequencies.