• Title/Summary/Keyword: differential force

Search Result 426, Processing Time 0.026 seconds

Comparative analysis on darcy-forchheimer flow of 3-D MHD hybrid nanofluid (MoS2-Fe3O4/H2O) incorporating melting heat and mass transfer over a rotating disk with dufour and soret effects

  • A.M. Abd-Alla;Esraa N. Thabet;S.M.M.El-Kabeir;H. A. Hosham;Shimaa E. Waheed
    • Advances in nano research
    • /
    • v.16 no.4
    • /
    • pp.325-340
    • /
    • 2024
  • There are several novel uses for dispersing many nanoparticles into a conventional fluid, including dynamic sealing, damping, heat dissipation, microfluidics, and more. Therefore, melting heat and mass transfer characteristics of a 3-D MHD Hybrid Nanofluid flow over a rotating disc with presenting dufour and soret effects are assessed numerically in this study. In this instance, we investigated both ferric sulfate and molybdenum disulfide as nanoparticles suspended within base fluid water. The governing partial differential equations are transformed into linked higher-order non-linear ordinary differential equations by the local similarity transformation. The collection of these deduced equations is then resolved using a Chebyshev spectral collocation-based algorithm built into the Mathematica software. To demonstrate how different instances of hybrid/ nanofluid are impacted by changes in temperature, velocity, and the distribution of nanoparticle concentration, examples of graphical and numerical data are given. For many values of the material parameters, the computational findings are shown. Simulations conducted for different physical parameters in the model show that adding hybrid nanoparticle to the fluid mixture increases heat transfer in comparison to simple nanofluids. It has been identified that hybrid nanoparticles, as opposed to single-type nanoparticles, need to be taken into consideration to create an effective thermal system. Furthermore, porosity lowers the velocities of simple and hybrid nanofluids in both cases. Additionally, results show that the drag force from skin friction causes the nanoparticle fluid to travel more slowly than the hybrid nanoparticle fluid. The findings also demonstrate that suction factors like magnetic and porosity parameters, as well as nanoparticles, raise the skin friction coefficient. Furthermore, It indicates that the outcomes from different flow scenarios correlate and are in strong agreement with the findings from the published literature. Bar chart depictions are altered by changes in flow rates. Moreover, the results confirm doctors' views to prescribe hybrid nanoparticle and particle nanoparticle contents for achalasia patients and also those who suffer from esophageal stricture and tumors. The results of this study can also be applied to the energy generated by the melting disc surface, which has a variety of industrial uses. These include, but are not limited to, the preparation of semiconductor materials, the solidification of magma, the melting of permafrost, and the refreezing of frozen land.

Model on the Capillary Action-Induced Dynamics of Contact Lens (모세관 작용에 의한 콘택트 렌즈의 운동 모델)

  • Kim, Dae-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.85-97
    • /
    • 2001
  • A mathematical model was proposed to analyze the damped motion of contact lens which is initially displaced from the equilibrium position. The model incorporates the differential equations and their numerical solution program, based on the formulations of restoring force arising from the capillary action in the tear-film layer between the lens and cornea. The model predicts the capillary action induced surface tension, time dependence of displacement of lens when it is released from the equilibrium position. It seems that the motion of lens is similar to the typical over-damped oscillation caused by the large viscous friction in the liquid layer between the cornea and lens. The effect of variables such as base curves, lens diameters and thickness of tear film layer were illustrated by the computer simulation of the derived program. The time required for the lens to return to the original position increases as the liquid layer thickness increases and it decreases as the diameter of lens increases. With the certain value of base curve the time interval is found to be minimum. The free vibrations of lenses were also simulated varying the parameters such as base curve, diameter, layer thickness. The resonant frequencies are inversely proportional to the liquid layer thickness and it increases as the lens diameter increases. The resonant frequency of lens has a maximum when the diameter is of certain value. If the external impulse or force of the same frequency as the natural frequency of contact lens acted on the cornea in vivo it may cause an excessive movement and thus it might cause the distortion 10 the lens or be pulled off the eye.

  • PDF

Pork Quality Traits According to Postmortem pH and Temperature in Berkshire

  • Kim, Tae Wan;Kim, Chul Wook;Yang, Mi Ra;No, Gun Ryoung;Kim, Sam Woong;Kim, Il-Suk
    • Food Science of Animal Resources
    • /
    • v.36 no.1
    • /
    • pp.29-36
    • /
    • 2016
  • This study was performed to investigate the role of pH and temperature postmortem, and to demonstrate the importance of these factors in determining meat quality. Postmortem pH45min (pH at 45 min postmortem or initial pH) via analysis of Pearson’s correlation showed high positive correlation with pH change pHc24 (pH change from pH45min to pH24h postmortem). However, postmortem pH after 24 h (pH24h or ultimate pH) had a high negative correlation with pH change, pHc24, CIE L*, and protein content. Initial temperature postmortem (T1h ) was positively associated with a change in temperature from 45 min to 24 h postmortem (Tc24) and cooking loss, but negatively correlated with water holding capacity. Temperature at 24 h postmortem (T24h) was negatively associated with Tc24. Collectively, these results indicate that higher initial pH was associated with higher pHc24, T1h, and Tc24. However, higher initial pH was associated with a reduction in carcass weight, backfat thickness, CIE a* and b*, water holding capacity, collagen and fat content, drip loss, and cooking loss as well as decreased shear force. In contrast, CIE a* and b*, drip loss, cooking loss, and shear force in higher ultimate pH was showed by a similar pattern to higher initial pH, whereas pHc24, carcass weight, backfat thickness, water holding capacity, fat content, moisture content, protein content, T1h, T24h, and Tc24 were exhibited by completely differential patterns (p<0.05). Therefore, we suggest that initial pH, ultimate pH, and temperatures postmortem are important factors in determining the meat quality of pork.

Comparison of Super Structure-Sub Structure Separation Analysis and Unification Analysis about Building Structures (건축구조물의 상부구조-하부구조 분리해석과 일체해석의 비교분석)

  • Kim, Jae-Yo;Kim, Jin-Yong;Kang, Su-Min
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.1
    • /
    • pp.19-28
    • /
    • 2016
  • In the case of structural analysis for building structures, the super-structure and the sub-structure are analyzed by using separate structural models in the field because of time saving, facile result interpretation and easy analysis of dynamic behavior. However this separate structural model violated the compatibility condition of structural analysis and it can not consider the interaction of superand sub- structures. In the present study, the analysis results of this separate model were compared to those of the unified model of super- and sub- structures which can consider the interaction of super- and sub- structures and reflect the realistic boundary conditions. According to the comparison results, the the analysis model using separate models can underestimate the member force and deflection of structural members in the super-structures and overestimate the deflection and member force of sub-structures. Therefore, in the case of high-rise buildings, irregular shaped buildings, buildings which are expected to be affected by large differential settlement and remodeling buildings, the unified structural model for super- and sub- structures was recommended for structural analysis instead of the separate structural model.

Fundamentals of Tight fitted Contact Lens Movement (Tight Fit 콘택트렌즈 운동의 기초)

  • Kim, Dae Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.17-27
    • /
    • 2009
  • Purpose: This review article was written to determine the effects of parameters characterizing a hard contact lens (RGP included), such as BCs, diameters, edge angles, on the time interval for tight fitted lens to return to the equilibrium when it was decentered from blinking. Methods: A mathematical formulation was established to relate or calculate the restoring forces and thickness of lacrimal layer beneath the cornea with the various lens parameters when the tight fitted lens was decentered from blinking. Based on this formulation the differential equations and their numerical solution program were set up to describe the time dependence of the lens on the position and to estimate the time for the lens's return to the equilibrium after blink. Results: It is found that the time interval for the tight fitted lens to return to the equilibrium decreases as either the BC decreases or the diameter increases because both the reduction in BC and increase in diameter result in the increase in the lacrimal layer thickness between the lens and cornea increase which yielded the lowering of the viscous friction in the lens motion. As the edge angle of tight fitted lens increases the time for recentering decreases due to the increase in restoring force without change in lacrimal thickness beneath the lens. In the case of flat fitted hard lens (RGP included), the lacrimal layer thickness under the lens increases as either BC or diameter increases which results in reduction in viscous friction so that the time for the lens's return to the equilibrium were to decrease. The edge angle of flat fitted lens does not affect the lens motion. Conclusions: The effect of BCs on the lens motion (time to approach the equilibrium) was concluded to be significant with both tight and flat fitted lens where its results are contrary with each other. The edge angle of lens only affects the motion in tight fitted lenses.

  • PDF

Modeling of flat otter boards motion in three dimensional space (평판형 전개판의 3차원 운동 모델링)

  • Choe, Moo-Youl;Lee, Chun-Woo;Lee, Gun-Ho
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.43 no.1
    • /
    • pp.49-61
    • /
    • 2007
  • Otter boards in the trawl are the one of essential equipments for the net mouth to be spread to the horizontal direction. Its performance should be considered in the light of the spreading force to the drag and the stability of towing in the water. Up to the present, studies of the otter boards have focused mainly on the drag and lift force, but not on the stability of otter boards movement in 3 dimensional space. In this study, the otter board is regarded as a rigid body, which has six degrees of freedom motion in three dimensional coordinate system. The forces acting on the otter boards are the underwater weight, the resistance of drag and spread forces and the tension on the warps and otter pendants. The equations of forces were derived and substituted into the governing equations of 6 degrees of freedom motion, then the second order of differential equations to the otter boards were established. For the stable numerical integration of this system, Backward Euler one of implicit methods was used. From the results of the numerical calculation, graphic simulation was carried out. The simulations were conducted for 3 types of otter boards having same area with different aspect ratio(${\lambda}=0.5,\;1.0,\;1.5$). The tested gear was mid-water trawl and the towing speed was 4k't. The length of warp was 350m and all conditions were same to each otter board. The results of this study are like this; First, the otter boards of ${\lambda}=1.0$ showed the longest spread distance, and the ${\lambda}=0.5$ showed the shorted spread distance. Second, the otter boards of ${\lambda}=1.0$ and 1.5 showed the upright at the towing speed of 4k't, but the one of ${\lambda}=0.5$ heeled outside. Third, the yawing angles of three otter boards were similar after 100 seconds with the small oscillation. Fourth, it was revealed that the net height and width are affected by the characteristics of otter boards such as the lift coefficient.

Lateral Drift Control of High-rise Buildings using Partial Reanalysis Algorithm (부분재해석 기법을 이용한 고층건물 횡변위제어)

  • Lee, Jae-Cheol;Kim, Chee-Kyeong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.1
    • /
    • pp.81-88
    • /
    • 2009
  • This paper alined at the development of a lateral drift control method that is able to quantitatively control the lateral drift of global node. For this, we applied an efficient partial reanalysis algorithm. By using this algorithm, we could recalculate the displacement and member force of the specific node without reanalyzing the entire structure when member stiffness changes partially. The theoretical concepts of the algorithm are so simple that it is not necessary to solve the complicate differential equation or to repeat the analysis of entire structure. The proposed method calculates the drift contribution of each member for the global displacement according to the variation of section sizes by using the algorithm. Then by changing the member sizes as the order of drift contribution, we could control the lateral drift of global node with a minimum quantity of materials. 20 story braced frame structure system is presented to illustrate the usefulness of proposed method. It is shown that the proposed method is very effective in lateral drift control and the results obtained by proposed method are consistent with those of commercial analysis program.

Quantitative Analysis of Enlarged Cervical Lymph Nodes with Ultrasound Elastography

  • Zhang, Jun-Peng;Liu, Hua-Yan;Ning, Chun-Ping;Chong, Jing;Sun, Yong-Mei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.16
    • /
    • pp.7291-7294
    • /
    • 2015
  • Purpsoe: To investigate the diagnostic value of quantitative analysis of a tissue diffusion and virtual touch tissue imaging quantification (VTIQ) technique with acoustic radiation force impulse (ARFI) elastography for assessing enlarged cervical lymph nodes. Materials and Methods: Fifty-six enlarged cervical lymph nodes confirmed by pathologic diagnoses were covered in the study. According to the results of pathologic diagnosis, patients were classified into benign and malignant groups. All the patients were examined by both conventional ultrasonography and elastography. AREA% and shear wave velocity (SWV) in ROI of different groups were calculated and compared using ROC curves. Cut-off points of AREA% and SWV were determined with receiver operating characteristic curves. Results: Final histopathological results revealed 21 cases of benign and 35 cases of malignant lymph nodes. The mean values of AREA% and SWV in benign and malignant groups were $45.0{\pm}17.9%$ and $2.32{\pm}0.57m/s$, and $61.3{\pm}21.29%$ and $4.36{\pm}1.25$)m/s, respectively. For the parameters of elastography, "AREA%" and SWV demonstrated significant differences between groups (p=0.002). AREA% was positively correlated with SWV with a correlation coefficient of 0.809 (P<0.001). Conclusions: Stiffness of different lymph node diseases in patients may differ. Elastography can evaluate changes sensitively and provide valuable information to doctors. The study proved that the VTIQ elastography technique can play an important role in differential diagnosis of lymph nodes.

An Image Encryption Scheme Based on Concatenated Torus Automorphisms

  • Mao, Qian;Chang, Chin-Chen;Wu, Hsiao-Ling
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.6
    • /
    • pp.1492-1511
    • /
    • 2013
  • A novel, chaotic map that is based on concatenated torus automorphisms is proposed in this paper. As we know, cat map, which is based on torus automorphism, is highly chaotic and is often used to encrypt information. But cat map is periodic, which decreases the security of the cryptosystem. In this paper, we propose a novel chaotic map that concatenates several torus automorphisms. The concatenated mechanism provides stronger chaos and larger key space for the cryptosystem. It is proven that the period of the concatenated torus automorphisms is the total sum of each one's period. By this means, the period of the novel automorphism is increased extremely. Based on the novel, concatenated torus automorphisms, two application schemes in image encryption are proposed, i.e., 2D and 3D concatenated chaotic maps. In these schemes, both the scrambling matrices and the iteration numbers act as secret keys. Security analysis shows that the proposed, concatenated, chaotic maps have strong chaos and they are very sensitive to the secret keys. By means of concatenating several torus automorphisms, the key space of the proposed cryptosystem can be expanded to $2^{135}$. The diffusion function in the proposed scheme changes the gray values of the transferred pixels, which makes the periodicity of the concatenated torus automorphisms disappeared. Therefore, the proposed cryptosystem has high security and they can resist the brute-force attacks and the differential attacks efficiently. The diffusing speed of the proposed scheme is higher, and the computational complexity is lower, compared with the existing methods.

THE USE OF MINISCREWS FOR TOOTH MOVEMENT IN CHILDREN (성장기 아동에서 miniscrew를 고정원으로 이용한 치아이동)

  • Kim, Sang-Min;Park, Ho-Won;Lee, Ju-Hyun;Seo, Hyun-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.4
    • /
    • pp.537-544
    • /
    • 2010
  • Anchorage control in orthodontic treatment is an important factor affecting treatment results. In the conventional approach, intra-oral anchorage such as application of differential force and moment, Nance holding arch and lingual arch, as well as extra-oral anchorage such as head gear were used for anchorage reinforcement. However, these anchorages may result in undesired tooth movement and require patient cooperation. To overcome these disadvantages, skeletal anchorage system was introduced as orthodontic anchorage. Types of skeletal anchorage include implant, onplant, miniplate and miniscrew. Especially, miniscrew has many advantages such as reduced patient cooperation, low cost and easy placement. Recently, it is successfully used in orthodontic treatment. This cases were treated using orthodontic miniscrews for retraction of ectopically erupting maxillary canine and impacted mandibular canine and intrusion of maxillary incisors.