• Title/Summary/Keyword: difference signal

Search Result 1,752, Processing Time 0.029 seconds

On Estimating the Incident Angles of Wide Band Signals in Low SNR Environment (신호 대 잡음비가 낮은 경우 광대역 신호의 입사각 추정)

  • Jo, Jeong-Gwon;Hwang, Yeong-Su;Cha, Il-Hwan;Yun, Dae-Hui
    • The Journal of the Acoustical Society of Korea
    • /
    • v.8 no.4
    • /
    • pp.44-52
    • /
    • 1989
  • The UCERSS (Unit Circle Eigendecomposition Rational Signal Subspace) algorithm has extended MUSIC (MUltiple Signal Classification ) by using eigendecomposition on the unit circle in order to estimate incident angles of multiple wide band signals. The purpose of this thesis is to further extend the UCERSS to be able to estimate the direction of arrivals of multiple wide band signals in very low SNR . The wide band ESPRIT (Estimation of Signal Parameter via Rotational Invariance Technique) uses covariance difference matrices to reduce noise components. In this paper the wide band ESPRIT which combines the ideas of UCERSS and ESPRIT Is proposed. Computer simulation results Indicate that the performances of the proposed approaches are superior to those of the UCERSS in very low SNR.

  • PDF

Comparison of Alpha-Factor Preprosequence and a Classical Mammalian Signal Peptide for Secretion of Recombinant Xylanase xynB from Yeast Pichia pastoris

  • He, Zuyong;Huang, Yuankai;Qin, Yufeng;Liu, Zhiguo;Mo, Delin;Cong, Peiqing;Chen, Yaosheng
    • Journal of Microbiology and Biotechnology
    • /
    • v.22 no.4
    • /
    • pp.479-483
    • /
    • 2012
  • The secretory efficiency of recombinant xylanase xynB from yeast Pichia pastoris between the ${\alpha}$-factor preprosequence and a classical mammalian signal peptide derived from bovine ${\beta}$-casein was compared. The results showed that although the bovine ${\beta}$-casein signal peptide could direct high-level secretion of recombinant xylanase, it was relatively less efficient than the ${\alpha}$-factor preprosequence. In contrast, the bovine ${\beta}$-casein signal peptide caused remarkably more recombinant xylanase trapped intracellularly. Real-time RT-PCR analysis indicated that the difference in the secretory level between the two signal sequences was not due to the difference in the transcriptional efficiency.

An Accidental Position Detection Algorithm for High-Pressure Equipment using Microphone Array (Microphone Array를 이용한 고압설비의 고장위치인식 알고리즘)

  • Kim, Deuk-Kwon;Han, Sun-Sin;Ha, Hyun-Uk;Lee, Jang-Myung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2300-2307
    • /
    • 2008
  • This study receives the noise transmitted in a constant audio frequency range through a microphone array in which the noise(like grease in a pan) occurs on the power supply line due to the troublesome partial discharge(arc). Then by going through a series of signal processing of removing noise, this study measures the distance and direction up to the noise caused by the troublesome partial discharge(arc) and monitors the result by displaying in the analog and digital method. After these, it determines the state of each size and judges the distance and direction of problematic part. When the signal sound transmitted by the signal source of bad insulator is received on each microphone, the signal comes only in the frequency range of 20 kHz by passing through the circuit of amplification and 6th low pass filter. Then, this signal is entered in a digital value of digital signal processing(TMS320F2812) through the 16-bit A/D conversion. By doing so, the sound distance, direction and coordinate of bad insulator can be detected by realizing the correlation method of detecting the arriving time difference occurring on each microphone and the algorithm of detecting maximum time difference.

Initial Rendezvous Protocol using Multicarrier Operation for Cognitive Radio Ad-hoc Networks

  • Choi, Ik-Soo;Yoo, Sang-Jo;Seo, Myunghwan;Han, Chul-Hee;Roh, Bongsoo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.6
    • /
    • pp.2513-2533
    • /
    • 2018
  • In cognitive radio technology, the overall efficiency of communications systems can be improved without allocating additional bands by allowing a secondary system to utilize the licensed band when the primary system, which has the right to use the band, does not use it. In this paper, we propose a fast and reliable common channel initialization protocol without any exchange of initialization messages between the cluster head and the member nodes in cognitive ad-hoc networks. In the proposed method, the cluster and member nodes perform channel-based spectrum sensing. After sensing, the cluster head transmits a system activation signal through its available channels with a predetermined angle difference pattern. To detect the cluster head's transmission channels and to join the cluster, each member node implements fast Fourier transform (FFT) and computes autocorrelation for the angle difference sequence of the received signal patterns. This is compared to the predetermined reference angle difference pattern. The join-request and channel-decision procedures are presented in this paper. Performance evaluation of the proposed method is presented in the simulation results.

Study of Cross Correlation Using DRS(Delayed Reference Sample) for Precision Time Measurement of Input Signal on Multilateration (다변측정감시시스템 신호 입력 시각 정밀 측정을 위한 DRS(Delayed Reference Sample)를 이용한 Cross Correlation 방안 연구)

  • Chang, Jae-Won;Lee, Sang Jeong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.3
    • /
    • pp.244-250
    • /
    • 2018
  • Multilateration acquires the transponder signal of target from receivers installed on the ground and calculates the position of the target using the difference of the signal acquisition time of each receiver. One of the factors that influence the positioning accuracy of Multilateration using the TDOA calculation method is the error due to the precision measurement of signal input time. When measuring the signal input time at the receiver, the input signal is sampled using the reference clock of the receiver and a reference sample having the same sampling rate is applied to the cross correlation technique. Therefore, the accuracy of the signal input time is proportional to the reference clock. In this paper, the algorithm for precisely measuring the signal input time by performing cross correlation between the input signal of the receiver and DRS(Delayed Reference Sample) is proposed. In order to verify this, we implemented the pulse signal of the transponder that is transmitted from the target using Matlab. Through the simulation, cross correlation between the proposed DRS and the input signal was performed. From this result, the performance of the precise measurement of signal input time was analyzed.

Low Magnetic Field MRI Visibility of Rubber-Based Markers

  • Kim, Jeong Ho;Jung, Seongmoon;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.89-93
    • /
    • 2019
  • Purpose: This study aims to develop new markers based on silicone rubber and urethane rubber to enhance visibility in low magnetic field magnetic resonance (MR) imaging. Methods: Four types of markers were fabricated using two different base materials. Two of the markers were composed of two different types of silicone rubber: DragonSkin™ 10 MEDIUM and BodyDouble™ SILK. The other two markers were composed of types of urethane rubber: PMC™ 780 DRY and VytaFlex™ 20. Silicone oil (KF-96 1000cs) was added to the fabricated markers. The allocated amount of oil was 20% of the weight (wt%) of each respective marker. The MR images of the markers, with and without the silicone oil, were acquired using MRIdian with a low magnetic field of 0.35 T. The signal intensities of each MR image for the markers were analyzed using ImageJ software and the visibility for each was compared. Results: The highest signal intensity was observed in VytaFlex™ 20 (279.67±3.57). Large differences in the signal intensities (e.g., 627% in relative difference between BodyDouble™ SILK and VytaFlex™ 20) among the markers were observed. However, the maximum difference between the signal intensities of the markers with the silicone oil showed only a 62% relative difference between PMC™ 780 DRY and DragonSkin™ 10 MEDIUM. An increase in the signal intensity of the markers with the silicone oil was observed in all markers. Conclusions: New markers were successfully fabricated. Among the markers, DragonSkin™ 10 MEDIUM with silicone oil showed the highest MR signal intensity.

Signal Change and Compensation of Pulse Pressure Sensor Array Due to Wrist Surface Temperature (손목 피부 온도에 의한 맥센서 어레이(array)의 신호 변동 및 보정)

  • Jun, Min-Ho;Jeon, Young Ju;Kim, Young-Min
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.141-147
    • /
    • 2017
  • A pressure sensor in pulse measurement system is a core component for precisely measuring the pulse waveform of radial artery. A pulse sensor signal that measures the pulse wave in contact with the skin is affected by the temperature difference between the ambient temperature and skin surface. In this study, we found experimentally that the signal changes of the pressure sensors and a temperature sensor were caused by the temperature of the wrist surface while the pressure sensor was contacted on the skin surface for measuring pulse wave. To observe the signal change of the pulse sensor caused by temperature increase on sensor surface, Peltier device that can be kept at a set temperature was used. As the temperature of Peltier device was kept at $35^{\circ}C$ (the maximum wrist temperature), the device was put on the pulse sensor surface. The temperature and pressure signals were obtained simultaneously from a temperature sensor and six pressure sensors embedded in the pulse sensor. As a result of signal analysis, the sensor pressure was decreased during temperature increase of pulse sensor surface. In addition, the signal difference ratio of pressure and temperature sensors with respect to thickness of cover layer in pulse sensor was increased exponentially. Therefore, the signal of pressure sensor was modified by the compensation equation derived by the temperature sensor signal. We suggested that the thickness of cover layer in pulse sensor should be designed considering the skin surface temperature.

Comparison of On-Line Diagnotic Methods on Multi-Channel Signals in Nuclear Plant (원자력발전소 다채널 신호의 온라인 진단방법 비교)

  • Lee, Kwang-Dae;Yang, Seung-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.705-708
    • /
    • 2003
  • In this paper, we have evaluated the methods to generate the reference signal for the diagnosis of multi-channel signals. The channel signal integrity can be known by the difference between the reference signal and each channel value. The generation method of reference signal is important in the diagnosis of multi-channel measurement system. The continuous weighting average method rejects the abnormal signal using weighting method and makes the reference signal using sumation of all channel values. This gives the simple and reasonable reference signal. The principle component analysis, one of the multivariate analysis methods, and the neural network method give the reliable reference signal by using signal models, and learning algorithm. Two methods can make the reliable reference if all signals are normal, but any signal having the drift have an effect on the reference.

  • PDF

2D Backtracking Method of Ultrasonic Signal (초음파 신호의 2차원 역추적 방법에 관한 연구)

  • Kyu-Joung Lee;Choong Ho Lee
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.24 no.3
    • /
    • pp.172-177
    • /
    • 2023
  • In this paper, 2-dimensional backtracking method for ultrasonic signals. Ultrasonic sensors are a common technology used in industrial fields as many studies have been conducted on distance measurement and indoor location tracking using transmission and reception devices in pairs. A method for tracking a signal of an arbitrary ultrasonic transmission device on a 2D plane using only a receiver of an ultrasonic signal is proposed. In order to track the ultrasonic signal, the receiver receives the signal by making at least three. The three receivers may calculate a direction and a distance using a time difference in which the ultrasound reception sound is reached. The existing method of tracking signal sources using ultrasonic waves has a problem of time synchronization of devices because the transceivers must be paired or installed independently for each sensor. In order to solve this problem, the distance of the ultrasonic receiver is minimized, and it is configured as one device. The sensor installed as one device may be processed by one operator, thereby solving the time synchronization problem. To increase time difference accuracy, high-speed 32-bit timers with high time resolution can be used to quickly calculate and track distances and directions.

Signal qualification method for high density disk (고밀도 디스크를 위한 신호 품질 평가 방법)

  • Park Hyun-Soo
    • Transactions of the Society of Information Storage Systems
    • /
    • v.1 no.1
    • /
    • pp.53-57
    • /
    • 2005
  • In order to measure signal quality of optical disc such as CD or DVD, jitter is used traditionally. The signal attained from a disc by optical pick-up is processed by analog circuits. And then, binary signal can be obtained by using proper silcer. After the signal is changed into binary format, jitter is calculated as a time difference between the binary signal and the reference time. Jitter is used to express the signal quality. In this paper, a new method that is able to offer more precise measurement of the signal quality fur high density optical disc than the jitter is proposed. We named it LPSNR (Level Peak Signal to Noise Ratio). The relationship between bER (bit error rate) and LPSNR is shown in the paper.

  • PDF