• Title/Summary/Keyword: difference signal

Search Result 1,762, Processing Time 0.027 seconds

Development of Small Size Coriolis Mass Flowmeter (소형 코리올리 질량 유량계의 개발)

  • Lim Ki-Won;Ji Jueng-Keun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.6 s.249
    • /
    • pp.497-504
    • /
    • 2006
  • A Coriolis mass flowmeter(CMF), which has U-Shaped unique measurins tube was developed fo. direct mass flow measurement. In order to convert the time difference between two measuring tubes motion into mass flowrate and flow quantity, a signal processing circuit, as a part of CMF, was also developed. The CMF was designed as the 15 mm nominal diameter of pipe connection and the 8 mm stainless steel(sus 316) pipe was used for measuring tube. To maximize the flow signal(time difference) from the measuring tubes, the natural frequency of measuring tube was adjusted as 220 Hz, which is same as the frequency of exciter. The maximum displacement at the end of the measuring tube was measured as 0.05 mm and the maximum time difference between two measuring tubes was observed as $20{\mu}s$, which was proper for discrimination and measuring range of CMF. The developed CMF was tested against the gravimetric flowmeter calibrator in the range of 3 kg/min and 30 kg/min. The results showed that the CMF has good linearity and repeatability in the tested flow range. Large size of CMF base on the current study experience will be developed.

Unmanned Patient Monitoring System Using Frame Difference Method and Decibel Threshold (프레임 차이법과 데시벨 임계치를 이용한 무인 환자 감시 시스템)

  • Lee, Kee-Woo;Lee, Hyuk-Soo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • In this paper, we propose an unmanned patient monitoring system design and performance of a motion capture and sound detection. Unmanned patient monitoring system can be used in the greek koma and meaning deep sleep patient to need 24 hour surveillance. To monitoring, we used laptop, CCTV camera (or PC camera), A/D converter, microphone and detection program. The detection program based on the frame difference method and sound level meter. It had several functions such as data collecting and storing. All of this system was tested in several the simulations of emergency situations. It can be expected that an unmanned patient monitoring system can be used in emergency situation and patient care.

  • PDF

Location Error Analysis of an Active RFID-Based RTLS in Multipath and AWGN Environments

  • Myong, Seung-Il;Mo, Sang-Hyun;Yang, Hoe-Sung;Cha, Jong-Sub;Lee, Heyung-Sub;Seo, Dong-Sun
    • ETRI Journal
    • /
    • v.33 no.4
    • /
    • pp.528-536
    • /
    • 2011
  • In this paper, we analyze the location accuracy of real-time locating systems (RTLSs) in multipath environments in which the RTLSs comply with the ISO/IEC 24730-2 international standard. To analyze the location error of RTLS in multipath environments, we consider a direct path and indirect path, in which time and phase are delayed, and also white Gaussian noise is added. The location error depends strongly on both the noise level and phase difference under a low signal-to-noise ratio (SNR) regime, but only on the noise level under a high SNR regime. The phase difference effect can be minimized by matching it to the time delay difference at a ratio of 180 degrees per 1 chip time delay (Tc). At a relatively high SNR of 10 dB, a location error of less than 3 m is expected at any phase and time delay value of an indirect signal. At a low SNR regime, the location error range increases to 8.1 m at a 0.5 Tc, and to 7.3 m at a 1.5 Tc. However, if the correlation energy is accumulated for an 8-bit period, the location error can be reduced to 3.9 m and 2.5 m, respectively.

A Study for Absolutely Distance Measurement System of Wavelength Variable Type by Using Pinciple of the Michelson Interometer (마이켈슨 간섭계의 원리를 이용한 파장변화형 절대 거리측정기의 기초 연구)

  • 김철한;신영록;양윤석;김한근;사공건
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.651-653
    • /
    • 2000
  • In this study, a distance-measurement system was proposed by using principle of the Michelson Interferometer and a fundamental research was carried out. In case of the rnichelson interferometer, relativity distance was measured by relativity-difference of two course of light. But wavelength of light source were changed in this system in order to use interference phenomenon of michelson interferometer in measuring absolutely distance. Wavelength of input signal were changed periodically and were interfered electrically. So absolute distance can be calculated by using $\Delta\lambda$ and measuring $\eta\Delta$ in electric interference. Nose by a external factor was small in this system because a absolutely distance was measured by phase difference. And a dispersion of noise was small in pulse-echo response because a error was occurred in range of phase difference of signal. Also very wide range can be measured by only single system because informations of distance were acquisited in wavelength level.

  • PDF

Direction Finding Method of the Uniform Circular Array Antenna Using the Pattern of Phase Differences (원형배열 안테나의 위상차 패턴을 이용한 방향탐지 기법)

  • Lim, Joong-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 2019
  • In this paper, we have studied a direction finding method of the radio signal by comparing the phase difference and its pattern from the uniform circular array antenna. In the phase comparison direction finding, if the length of the antenna baseline is longer than 0.5 wavelength of the incident signal, azimuth ambiguity occurs in which two or more azimuth angles are calculated in the same phase difference. The azimuthal ambiguity is removed by fusing the phase difference of the 5 antennas. The developed ambiguity elimination technology reduces the azimuth error where the antenna baseline is shorter than 1.236 wavelength in the uniform circular array with five antennas. This algorithm is very useful for the design of direction finder of an electronic information system.

Roles of mTOR and p-mTOR in Gastrointestinal Stromal Tumors

  • Li, Jun-Chuan;Zhu, Hong-Yu;Chen, Ting-Xuan;Zou, Lan-Ying;Wang, Xiao-Yan;Zhao, Hui-Chuan;Xu, Jun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.10
    • /
    • pp.5925-5928
    • /
    • 2013
  • Objective: This study aimed to examine the relationship between expression of mammal target of rapamycin (mTOR) and phosphorylation of mTOR (p-mTOR) protein in the PI3K/Akt/mTOR signaling pathways in gastrointestinal stromal tumors and relatiuonships with clinical factors. Methods: Immunohistochemistry was used to detect the expression of the associated proteins mTOR, p-mTOR, and phosphorylation of the tumor suppressor genes PTEN, P27, VEGF, and EGFR in 40 cases of gastrointestinal stromal tumors, with division into a very low and low risk group as well as a moderate and high risk group. Results: The positive rate of mTOR and p-mTOR was significantly increased in the moderate and high risk group compared with the very low and low risk group. The difference was statistically significant (P<0.05). When grouped according to size, the positive mTOR expression rate exhibited a statistical difference (P<0.05), which was significantly increased in the group of tumors larger than 5 cm. The difference in the positive mTOR and p-mTOR expression rate exhibit no statistical significance among the PTEN, P27, VEGF, and EGFR expression subgroups (P>0.05). Conclusion: The different expressions of mTOR and p-mTOR in the signal transduction pathway of gastrointestinal stromal tumor in the different degree-of-risk groups suggested that the mTOR and p-mTOR of the signal transduction pathway serve an important function in the occurrence and development of gastrointestinal stromal tumors.

Comparative Study on Signal Strength of Mechanical Index Using Ultrasound Machines with SonoVue Contrast (Sonovue 초음파 조영제를 이용한 장비 간 Mechanical Index의 변화에 따른 신호 강도 비교연구)

  • Kim, Myung-Seok;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.21-29
    • /
    • 2019
  • The purpose of this study was to compare the MI using SonoVue along with different machines output and to infer the meaning of the signal difference under the same condition. All of the comparative instruments showed strong signal values at early stage as MI value increased. Over time, the inter-instrumental signal values showed signal attenuation under all conditions except for 10 min of the condition of MI 0.1 of RS85A. E9 and EPIQ7 showed signal degradation due to microbubble collapse over time at all MI values. In the comparison of equipment, the signal strengths of MI 0.1, 0.2, and 0.4 were high in order of EPIQ7, RS85A and E9. In the quantitative analysis, there were statistically significant from the SNR and CNR that were obtained from RS85A and E9 (P-value<0.05). In the quantitative analysis, Epiq7 was statistically significant except for CNR as the MI value was changed In the contrast-enhanced ultrasound, even though MI value was low (MI <0.05), it will be helpful for diagnosis, controlling the MI and scan time because a difference in signal intensity was shown between the three machines.

An Analysis of Pedestrians' Speed according to Pedestrian Countdown Signal Systems (보행신호 잔여시간 표시장치에 따른 보행속도 분석)

  • Jang, Myeong-Sun;Im, Sam-Jin;Kim, Gyeong-Hui
    • Journal of Korean Society of Transportation
    • /
    • v.24 no.4 s.90
    • /
    • pp.43-53
    • /
    • 2006
  • Pedestrian countdown signals were newly introduced to make Pedestrians feel more comfortable and safer in crossing the streets This Paper analysed pedestrian walking-speed through a before-after behavior study Data was collected from 22 sites. and the total number of pedestrians was 19,800. The results showed that the average Pedestrian walking-speed of existing pedestrian signal, an inverted triangle countdown signal and a numeric countdown signal were 1.44, 1.39 and 1.42m/sec. The difference between the three methods was statistically significant. The results showed that the distribution of the walking-speed of existing signal. an inverted triangle countdown signal and a numeric countdown signal were statistically Erlang(0.117, 10) distribution. Weibull(1.17, 3.72) distribution and Gamma(0.137, 8.18) distribution at 95% confidence level.

Double Talk Detection before the Convergence of Echo Canceller (반향제거기의 수렴전 동시통화검출)

  • Yoo, Jae-Ha;Kim, Soo-Chan;Kim, Dong-Yon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.5
    • /
    • pp.203-208
    • /
    • 2013
  • In this paper, we proposed a performance improvement method of the double talk detector which can operate before the echo canceller converges. Microphone input signal is filtered by the linear prediction filter and this filtered signal is used for detection. The coefficients of the linear prediction filter are given by the far-end talker signal. During single talk, filtered signal has low power since the characteristics of the echo signal is similar with those of the far-end talker signal. But, during double talk, the filtered signal does not have low power because the signal of different characteristics is included in the microphone signal. Double talk is detected by this difference. Simulations using real speech signals verified that the proposed method outperformed the conventional methods.

Suppression Circuit Design of interference Using Orthogonal Signal (직교신호를 이용한 간섭 억제회로 설계)

  • Yoon, Jeoung-Sig;Chong, Jong-Wha
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.10A
    • /
    • pp.969-979
    • /
    • 2002
  • This paper proposes an novel method of minimizing Interference which causes data decision error in digital wireless communications. In this method, in order to suppress ISI which is caused by the phase difference between the transmitted and received signal phases, the transmitted and received signals are always kept orthogonal by compensating the transmitted signal for detecting the phase noise and the delay of the received signal was implemented by MOS circuits. To delay the phase of the signal, additive white Gaussian noise (AWGN) environment was used. The phase and delay of the signal transmitted through AWGN channel were compensated in the modulator of the transmitter and the compensated signal was demodulated using quasi-direct conversion receiver and QPSK demodulator. ISI suppression was achieved by keeping the orthogonality between the compensated transmitted signal and the receive signal. The error probability of data decision was compared. By simulation the proposed system was proved to be effective in minimizing the ISI.