• 제목/요약/키워드: diameter distribution models

검색결과 106건 처리시간 0.025초

$Br{\aa}nemark\;Novum^{(R)}$ 즉시 임플랜트 보철 수복 방법에 관한 삼차원 유한요소 분석적 연구 (THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF $BR{\AA}NEMARK\;NOVUM^{(R)}$ IMMEDIATE IMPLANT PROSTHODONTIC PROTOCOL)

  • 김우영;김영수;장경수;김창회
    • 대한치과보철학회지
    • /
    • 제39권5호
    • /
    • pp.463-476
    • /
    • 2001
  • Since the treatment of edentulous patients with osseointegrated implant was first introduced more than 30 years ago, implant therapy has become one of the most important dental treatment modalities today. Based on the previous experience and knowledge, $Br{\aa}nemark\;Novum^{(R)}$ protocol was introduced with the concept of simplifying surgical and prosthetic technique and reducing healing time recently. This protocol recommends the installation of three 5mm wide diameter futures in anterior mandible and the prefabricated titanium bars for superstructure fabrication. This study was designed to analyze the stress distribution at fixture and superstructure area according to changes of fixture number, diameter and superstructure materials. Four 3-dimensional finite element models were fabricated. Model 1 - 5 standard fixtures (13mm long and 3.75mm in diameter) & superstructure consisted of type IV gold alloy and resin Model 2- 3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of type IV gold alloy and resin Model 3-3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of titanium and resin Model 4-3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of titanium and porcelain A 150N occlusal force was applied on the 1st molar of each model in 3 directions - vertical($90^{\circ}$), horizontal($0^{\circ}$) and oblique($120^{\circ}$). After analyzing the stresses and displacements, following results were obtained. 1. There were no significant difference in stress distribution among experimental models. 2. Model 2, 3, 4 showed less amount of compressive stress than that of model 1. However, tensile stress was similar. 3. Veneer material with a high modulus of elasticity demonstrated less stress accumulation in the superstructure. Within the limites of this study, $Br{\aa}nemark\;Novum^{(R)}$ protocol demonstrated comparable biomechanical properties to conventional protocol.

  • PDF

국립산림과학원 제주시험림의 서어나무 수간형태와 수간곡선식 추정 (Development of Stem Profile and Taper Equation for Carpinus laxiflora in Jeju Experimental Forests of Korea Forest Research Institute)

  • 정영교;김대현;김철민
    • 농업생명과학연구
    • /
    • 제44권4호
    • /
    • pp.1-7
    • /
    • 2010
  • 본 연구는 난대산림연구소의 제주시험림에 있는 서어나무 (Carpinus laxiflora)에 대한 개체목의 수간곡선식 추정 및 재적표를 개발하기 위하여 수행하였다. 최적의 추정식을 선택하기 위하여 Max & Burkhart식, Kozak식 및 Lee식을 적용하여 수간곡선식을 유도한 후, 각 식의 직경 추정에 대한 검정 통계량 및 실측치와 추정치간의 오차분포를 검증하였다. 그 결과 Max & Burkhart식 및 Lee식이 특정 구간에서 과대치 또는 과소 추정치를 보인데 반하여 Kozak식은 전구간에서 고른 분포를 보였다. 추정력이 가장 좋은 Kozak식을 활용하여 수피포함 재적표를 작성하였다.

산사태 분포 예측을 위한 로지스틱, 베이지안, Maxent의 비교 (Comparison of Logistic, Bayesian, and Maxent Modelsfor Prediction of Landslide Distribution)

  • 알-마문;장동호;박종철
    • 한국지형학회지
    • /
    • 제24권2호
    • /
    • pp.91-101
    • /
    • 2017
  • Quantitative forecasting methods based on spatial data and geographic information system have been used in predicting the landslide location. This study compared the simulated results of logistic, Bayesian, and maximum entropy models to understand the uncertainties of each model and identify the main factors that influence landslide. The study area is Boeun gun where 388 landslides occurred in the year of 1998. The verification results showed that the AUC of the three models was 0.84. However, the landslide susceptibility distribution of Maxent model was different from those of the other two models. With the same landslide occurrence data, the result of high susceptible area in Maxent model is smaller than Logistic or Bayesian. Maxent model, however, proved to be more efficient in predicting landslide than the other two models. In Maxent's simulations, the responsible factors for landslide susceptibility are timber age class, land cover, timber diameter, crown closure, and soil drainage. The results suggest that it is necessary to consider the possibility of overestimation when using Logistic or Bayesian model, and forest management around the study area can be an effective way to minimize landslide possibility.

Effect of Boundary Conditions of Failure Pressure Models on Reliability Estimation of Buried Pipelines

  • Lee, Ouk-Sub;Pyun, Jang-Sik;Kim, Dong-Hyeok
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제4권6호
    • /
    • pp.12-19
    • /
    • 2003
  • This paper presents the effect of boundary conditions in various failure pressure models published for the estimation of failure pressure. Furthermore, this approach is extended to the failure prediction with the aid of a failure probability model. The first order Taylor series expansion of the limit state function is used in order to estimate the probability of failure associated with each corrosion defect in buried pipelines for long exposure period with unit of years. A failure probability model based on the von-Mises failure criterion is adapted. The log-normal and standard normal probability functions for varying random variables are adapted. The effects of random variables such as defect depth, pipe diameter, defect length, fluid pressure, corrosion rate, material yield stress, material ultimate tensile strength and pipe thickness on the failure probability of the buried pipelines are systematically investigated for the corrosion pipeline by using an adapted failure probability model and varying failure pressure model.

유한요소법을 이용한 치과 임플란트 고정체의 직경과 길이에 따른 지지골의 응력 분석 (Finite element analysis on the stress of supporting bone by diameters and lengths of dental implant fixture)

  • 이명곤
    • 대한치과기공학회지
    • /
    • 제38권3호
    • /
    • pp.151-156
    • /
    • 2016
  • Purpose: The dental implant should be enough to endure chewing load and it's required to have efficient design and use of implant to disperse the stress into bones properly. This study was to evaluate the stress distribution on a supporting bone by lengths and diameters of the implant fixture. Methods: The modeling and analysis of stress distribution was used for the simple molar porcelain crown model by Solidworks as FEM program. It was designed on applying with tightening torque of 20 Ncm of a abutment screw between a cement retained crown abutment and a fixture. The fixtures of experimental model used 10, 13mm by length and 4, 5mm by diameter. A external vertical loading on the two buccal cusps of crown and performed finite element analysis by 100 N. Results: The maximum von Mises stress(VMS) of all supporting bone models by fixture length and diameter were concentrated on the upper side of supporting compact bone. The maximum stress of each model under vertical load were 164.9 MPa of M410 model, and 141.2 MPa of M413 model, 54.3 MPa of M510 model, 53.6 MPa of M513 model. Conclusion: The stress reduction was increase of fixture's diameter than it's length. So it's effective to use the wider fixture as possible to the conditions of supporting bone.

Numerical and Experimental Analysis of Spray Atomization Characteristics of a GDI Injector

  • Park, Sung-Wook;Kim, Hyung-Jun;Lee, Chang-Sik
    • Journal of Mechanical Science and Technology
    • /
    • 제17권3호
    • /
    • pp.449-456
    • /
    • 2003
  • In this study, numerical and experimental analysis on the spray atomization characteristics of a GDI injector is performed. For numerical approach, four hybrid models that are composed of primary and secondary breakup model are considered. Concerning the primary breakup, a conical sheet disintegration model and LISA model are used. The secondary breakup models are made based on the DDB model and RT model. The global spray behavior is also visualized by the shadowgraph technique and local Sauter mean diameter and axial mean velocity are measured by using phase Doppler particle analyzer Based on the comparison of numerical and experimental results, it is shown that good agreement is obtained in terms of spray developing process and spray tip penetration at the all hybrid models. However, the hybrid breakup models show different prediction of accuracy in the cases of local SMD and the spatial distribution of breakup.

반건식 세정기의 슬러리 분무 특성에 따른 산성가스 제거효율 (The Effect of Spray Characteristics on Flue Gas Desulfurization Yield in Spray Drying Sorber)

  • 양현모;김상수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.79-84
    • /
    • 2001
  • The effect of spray characteristics on desulfurization yield was evaluated by performing experiments with pilot spray drying sorber (SDS). Among the variables of operating conditions, the slurry-spraying conditions were chosen as major parameters; Stoichiometric ratio and Sauter mean diameter of slurry droplet were varied for the different gas temperatures and $SO_{2}$ concentrations in the inlet gas flow. From the experimental results, we proposed semi-empirical models of desulfurization yield for both Stoichiometric ratio and Sauter mean diameter of droplets. The optimal condition of spray can be determined based on these results, which might be applied to the design or scale-up of SDS systems.

  • PDF

원형 노즐의 직경 변화 및 표면으로 부터의 거리변화에 따른 오목한 표면에 충돌하는 제트의 온도장 측정 및 CFD해석 (Temperature field measurement and CFD analysis of a jet impinging on a concave surface depending on changes in nozzle to surface distance and the diameter of a circular nozzle)

  • 조영민;임유진;염은섭
    • 한국가시화정보학회지
    • /
    • 제21권2호
    • /
    • pp.55-62
    • /
    • 2023
  • The characteristic of jet impinging on the concave surface were analyzed through thermographic phosphor thermometry (TPT) and numerical investigation. Under a jet Reynolds number of 6600, nozzle diameters and nozzle-to-surface distances (H/d) were changed 5mm and 10mm and H/d=2 and 5. The RNG k-ε turbulence model can accurately predict the distribution of Nusselt number, compared to other models (SST k-ω, realizable k-ε). Heat transfer characteristics varied with the nozzle diameter and H/d, with a secondary peak noted at H/d =2, due to vortex-induced flow detachment and reattachment. An increase in nozzle diameter enhanced jet momentum, turbulence strength, and heat transfer.

교정용 미니스크류 식립 시 스크류의 길이, 직경 및 피질골 두께에 따른 응력 분포에 관한 3차원 유한요소법적 연구 (Three dimensional finite element method for stress distribution on the length and diameter of orthodontic miniscrew and cortical bone thickness)

  • 임종원;김왕식;김일규;손충렬;변효인
    • 대한치과교정학회지
    • /
    • 제33권1호
    • /
    • pp.11-20
    • /
    • 2003
  • 본 연구는 교정치료 시 고정원 보강을 위해 사용되는 교정용 미니스크류의 길이, 직경 및 피질골 두께에 따른 응력 분포 양상을 알아보기 위하여 시행되었다. 미니스크류의 길이와 직경 변화에 따른 응력 분포 양상을 관찰하기 위하여 식립되는 피질골의 두께를 1.0mm로 고정하고 미니스크류의 길이를 6.0mm, 8.0mm, 10.0mm, 12.0mm로, 직경을 1.2mm, 1.6mm, 2.0mm인 3차원 유한요소 모델을 제작하였다. 또한, 피질골의 두께 변화에 따른 응력 분포 양상을 관찰하기 위하여 미니 스크류의 길이를 8.0mm로 고정하고 직경은 1.2mm, 1.6mm, 2.0mm로, 피 질골의 두께는 1.0mm, 1.5mm, 2.0mm, 2.5mm인 3차원 유한요소 모델을 제작하였다. 각각의 유한요소 모델의 미니스크류 head중심에 200gm의 수평력을 가하여 응력 분포 양상과 크기를 3차원 유한요소 해석 프로그램인 ANSYS를 이용하여 비교한 결과 다음과 같은 결론을 얻었다. 1. 미니스크류 내부에서 나타나는 최대 응력값을 비교한 결과, 미니스크류의 직경이 1.2mm에서 2.0mm로 증가할수록 응력이 감소하였으며 같은 직경에서는 길이 증가에 상관없이 일정한 값을 유지하였다. 2. 피질골 및 해면골에 작용되는 최대 응력값을 비교한 결과, 미니스크류의 직경이 1.2mm에서 2.0mm로 증가할수록 응력이 감소하였으며 같은 직경에서는 길이 증가에 상관없이 일정한 값을 유지하였다. 3. 피질골 및 해면골에 작용되는 응력 분포를 관찰한 결과, 대부분의 응력이 피질골에서 흡수되었으며 ,해면골에 전달되는 응력값은 미미하였다. 4. 피질골 두께에 따른 최대 응력값을 비교한 결과, 같은 미니스크류의 직경에서는 피질골의 두께 증가에 상관없이 일정한 값을 유지하였다. 이상의 결과는 교정용 미니스크류의 유지에 길이보다는 직경이 더 크게 관여하는 것으로 나타나 미니스크류의 식립시 이에 대한 고려가 필요함을 시사하였다.

APPLICATION OF FINITE ELEMENT ANALYSIS TO EVALUATE IMPLANT FRACTURES

  • Kim Yang-Soo;Kim Chang-Whe;Lim Young-Jun;Kim Myung-Joo
    • 대한치과보철학회지
    • /
    • 제44권3호
    • /
    • pp.295-313
    • /
    • 2006
  • Statement of problem. Higher fracture rates were reported for Branemark implants placed in the maxilla and for 3.75 mm diameter implants installed in the posterior region. Purpose. The purpose of this study was to investigate the fracture of a fixture by finite element analysis and to compare different diameter of fixtures according to the level of alveolar bone resorption. Material and Methods. The single implant and prosthesis was modeled in accordance with the geometric designs for the 3i implant systems. Models were processed by the software programs HyperMesh and ANSA. Three-dimensional finite element models were developed for; (1) a regular titanium implant 3.75 mm in diameter and 13 mm in length (2) a regular titanium implant 4.0 mm in diameter and 13 mm in length (3) a wide titanium implant 5.0 mm in diameter and 13 mm in length each with a cementation type abutment and titanium alloy screw. The abutment screws were subjected to a tightening torque of 30 Ncm. The amount of preload was hypothesized as 650 N, and round and flat type prostheses were 12 mm in diameter, 9 mm in height were loaded to 600 N. Four loading offset points (0, 2, 4, and 6 mm from the center of the implants) were evaluated. To evaluate fixture fracture by alveolar bone resorption, we investigated the stress distribution of the fixtures according to different alveola. bone loss levels (0, 1.5, 3.5, and 5.0 mm of alveolar bone loss). Using these 12 models (four degrees of bone loss and three implant diameters), the effects of load-ing offset, the effect of alveolar bone resorption and the size of fixtures were evaluated. The PAM-CRASH 2G simulation software was used for analysis of stress. The PAM-VIEW and HyperView programs were used for post processing. Results. The results from our experiment are as follows: 1. Preload maintains implant-abutment joint stability within a limited offset point against occlusal force. 2. Von Mises stress of the implant, abutment screw, abutment, and bone was decreased with in-creasing of the implant diameter. 3. With severe advancing of alveolar bone resorption, fracture of the 3.75 and the 4.0 mm diameter implant was possible. 4. With increasing of bending stress by loading offset, fracture of the abutment screw was possible.