• Title/Summary/Keyword: diameter 3

Search Result 9,968, Processing Time 0.038 seconds

Normal Corpus Callosum Dimensions Measured by MRI (MR Midsagittal 영상을 이용한 정상 뇌량의 크기 측정)

  • Kim, Ham-Gyum
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.277-285
    • /
    • 2008
  • As a result of measuring the size of corpus callosum in normal Korean people by using MRI, the following conclusions were obtained. 1. Maximum, minimum, and mean values by the region in whole subjects 1) Anteroposterior length amounted to the mean with 69.30mm, the minimum with 50.70mm, and the maximum with 80.40mm. 2) Diameter of genu amounted to the mean with 11.93mm, the minimum with 6.00mm, and the maximum with 18.50mm. 3) Diameter of mid body amounted to the mean with 7.00mm, the minimum with 3.40mm, and the maximum with 10.40mm. 4) Diameter of narrowing portion amounted to the mean with 4.51mm, the minimum with 0.80mm, and the maximum with 9.50mm. 5) Diameter of splenium amounted to the mean with 12.17mm, the minimum with 6.90mm, and the maximum with 17.20mm. 2. Comparison by region according to the gender in the whole subjects 1) Anteroposterior length was bigger in men than in women, and showed the significant difference depending on gender. 2) Diameter of genu, diameter of mid body, and diameter of narrowing portion were bigger in men than in women, but there was no significant difference. 3) Diameter of splenium was bigger in men than in women, and showed the statistically significant difference. 3. Comparison by region according to the age in the whole subjects 1) Anteroposterior length was the biggest in the 50s at the age, and was smaller in heir 10s than other age levels. In addition, the significant difference was indicated depending on age. 2) Diameter of genu and diameter of mid body were the biggest in their 30s, and were smaller in the 60s than other age levels. And, the statistically significant difference was indicated. 3) Diameter of narrowing portion was the thickest in their 20s, and was thinner in their 60s than other age levels. And, the significant difference was indicated depending on age. 4) Diameter of splenium was the thickest in their 30s, and was thinner in their 10s than other age levels. And, the statistically significant difference was indicated. 4. Correlation by region in whole subjects 1) Diameter of genu showed the statistically significant positive correlation with anteroposterior length. 2) Diameter of mid body showed the statistically significant positive correlation with anteroposterior length and diameter of genu. 3) Diameter of narrowing portion didn't show the statistically significant correlation with anteroposterior length, but showed the statistically significant positive correlation with diameter of genu and diameter of mid body. 4) Diameter of splenium showed the statistically significant positive correlation with anteroposterior length, diameter of genu, diameter of mid body, and diameter of narrowing portion.

  • PDF

A Study on the Correlation Between Nugget Diameter and Contact Diameter of Sheets by Electrode Force (點熔接 의 너깃지름 과 板間接觸지름 의 關聯性)

  • 송삼홍;김부동
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.7 no.3
    • /
    • pp.313-318
    • /
    • 1983
  • It is required in designing a spot welding to get in advance an estimated figure of nugget diameter. A method of estimating nugget diameter of low carbon steel sheets is suggested in tesms of utilizing elastic calculation in theory and of making a sectional observation of specimen of spot welding in experiment. The resultant findings are summarized as follows: 1) A contact diameter of sheet, 2.gamma.$_{o}$=d sub e/+(1.1)t, wheer de is the electrode tip diameter and t is the thickness of sheets. 2) The practical measurement of the nugget diameter reveals that $d_{n}$=(1.05) $d_{e}$+(0.9)t, and $d_{b}$ is less by 0.8-4.3% than 2.gamma.$_{o}$. 3) The more $d_{n}$ is as compared with t, the less the difference between a theoretical value and an experimental value is. 4) In the spot welding of thin steel sheets less than 3mm in thickness that are commonly used in sheet metal works, the contact diameter equals the nugget diameter. In this case, either the theoretical or experimental approach can be used for estimating the nugget diameter.meter.ter.r.

Fault Diameter and Mutually Disjoint Paths in Multidimensional Torus Networks (다차원 토러스 네트워크의 고장지름과 서로소인 경로들)

  • Kim, Hee-Chul;Im, Do-Bin;Park, Jung-Heum
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.34 no.5_6
    • /
    • pp.176-186
    • /
    • 2007
  • An interconnection network can be represented as a graph where a vertex corresponds to a node and an edge corresponds to a link. The diameter of an interconnection network is the maximum length of the shortest paths between all pairs of vertices. The fault diameter of an interconnection network G is the maximum length of the shortest paths between all two fault-free vertices when there are $_k(G)-1$ or less faulty vertices, where $_k(G)$ is the connectivity of G. The fault diameter of an R-regular graph G with diameter of 3 or more and connectivity ${\tau}$ is at least diam(G)+1 where diam(G) is the diameter of G. We show that the fault diameter of a 2-dimensional $m{\times}n$ torus with $m,n{\geq}3$ is max(m,n) if m=3 or n=3; otherwise, the fault diameter is equal to its diameter plus 1. We also show that in $d({\geq}3)$-dimensional $k_1{\times}k_2{\times}{\cdots}{\times}k_d$ torus with each $k_i{\geq}3$, there are 2d mutually disjoint paths joining any two vertices such that the lengths of all these paths are at most diameter+1. The paths joining two vertices u and v are called to be mutually disjoint if the common vertices on these paths are u and v. Using these mutually disjoint paths, we show that the fault diameter of $d({\geq}3)$-dimensional $k_1{\times}k_2{\times}{\cdots}{\times}k_d$ totus with each $k_i{\geq}3$ is equal to its diameter plus 1.

INFLUENCE OF IMPLANT DIAMETER ON THE OSSEOINTEGRATION OF IMPLANTS : AN EXPERIMENTAL STUDY IN RABBITS (임플란트 직경이 골유착에 미치는 영향에 관한 연구)

  • Lee Jun-Ho;Shin Sang-Wan;Kwon Sang-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.169-181
    • /
    • 2003
  • Statement of problem : The survival rate of wide diameter implants was lower than of 3.75-mm implants in some clinical researches. Purpose : The purpose of this study was to investigate the influence of implant diameter on the osseointegration of implants in the rabbit femoral condyle and tibial metaphyses by means of removal torque measurements and histomorphometric analysis. Material and Method : Ten adult New Zealand White rabbits were used in this study Two 3.75-mm diameter implants were inserted through one cortical layer in the tibial metaphyses and one 3.75-mm diameter implant was inserted in the femoral condyle. 5.0-mm diameter implants were inserted in the other leg in the same manner. A total of 60 implants (3.75-mm diameter implants:30 : 5.0-mm diameter implants:30) were installed. After a healing time of 4 and 12 weeks, the peak removal torque values required to shear off the implants were recorded. From the removal torque values (Ncm) obtained, the mean shear stress ($N/mm^2$) was calculated. And the percentage of direct bone-to-implant contact and the percentage of bone area inside the thread were measured by Kappa Image Base-metreo. The Student's t-test was undertaken for statistical analysis (p<0.05). Results : The removal torque value of 5.0-mm diameter implants was higher than of 3.75-mm diameter implants (p<0.05). The difference of shear stress value between 3.75-mm and 5.0-mm diameter implants was not statistically significant (p>0.05). The percentage direct bone-to-implant contact had no statistical difference between two groups (p>0.05). The percentage of bone area inside the thread had no statistical difference between two groups (p>0.05). Conclusion It is concluded that the quality f osseointegration is not influenced by increasing implant diameter.

Diameter Growth Analysis for Major Species using National Forest Resource Inventory - In the Gangwon-do Forests - (국가산림자원조사를 이용한 주요수종별 직경생장량 분석 - 강원도 산림을 대상으로 -)

  • Lee, Won-A;Shin, Ju-Won;Choi, Jung-Kee;Lee, Woo-Kyun;Lee, Young-Jin;Kim, Sung-Ho;Jung, Dong-Jun
    • Journal of Forest and Environmental Science
    • /
    • v.27 no.2
    • /
    • pp.113-118
    • /
    • 2011
  • This study was carried out to analyze annual diameter growth characteristics for major 11 tree species using the data for Gangwon province of the National Forest Resources Inventory in 2007. The annual diameter growth of coniferous species was 5.02 mm, 4.70 mm, and 3.90 mm in Korean white pine, Japanese larch, and Korean red pine, respectively. In growths of the deciduous trees, dogwood, basswood, and cork oak had 3.55 mm, 3.48 mm and 3.01 mm, respectively. Average of the annual diameter growths for all species was 3.38 mm. The relationship between diameter growth and age class showed that the growth rate decreased for all species as age increased. The age class II had the highest annual diameter rate. In relation of the stand density(trees per hectare) and diameter growth, the diameter growth tended to decrease as the stand density increased for most species, especially Korean white pine, cork oak, and basswood. Finally age had the highest value in the correlation coefficients between measurement factor and growth rate regardless of species.

[Retracted]Improving Performance of Foam Proportioner Utilizing Metering Venturi Type ([논문철회]미터링 벤츄리를 이용한 포소화약제 혼합장치의 성능개선)

  • Joo, Seung-Ho;Kong, Ha-Sung;Gong, Ye-Som
    • Fire Science and Engineering
    • /
    • v.29 no.3
    • /
    • pp.48-52
    • /
    • 2015
  • In this study, we have evaluated whether the mixing ratio is proper by creating a mixing device for foam proportioner that mainly is employed in practice utilizing a metering venturi type. In case of the mixing ratio for 3%, water under pressure of 76 mm in diameter and the original liquid of a foam fire extinguishing agent of 31.75 mm in diameter have showed up the fluctuation rate just as much as 3.1~3.5% of the mixing ratio. Because water under pressure of 101.6 mm in diameter and the original liquid of a foam fire extinguishing agent of 38.1 mm in diameter have showed up 3.3~3.7% of the fluctuation rate, water under pressure of 101.6 mm in diameter and the original liquid of a foam fire extinguishing agent of 38.1 mm in diameter have satisfied 3.0~3.9% of performance criterion. And also, in case of the 6% of mixture rate, water under pressure of 76.2 mm in diameter and the original liquid of a foam fire extinguishing agent of 31.75 mm in diameter have showed up the fluctuation rate just as much as 6.4~6.8% of the mixing ratio. Because water under pressure of 101.6 mm in diameter and the original liquid of a foam fire extinguishing agent of 38.1 mm in diameter have showed up 6.0~6.8% of the fluctuation rate, water under pressure of 101.6 mm in diameter and the original liquid of a foam fire extinguishing agent of 38.1 mm in diameter have satisfied 6.0~7.0% of performance criterion.

Study on the evaporation Heat Transfer Characteristics of R-134a in Small Diameter Tubes

  • Roh, Geon-Sang;Oh, Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.3
    • /
    • pp.224-234
    • /
    • 2007
  • Large diameter tubes have been used until comparatively lately. However, small diameter tubes are largely used because of their high efficiency in heat transfer and low cost, recently. This study focuses on the experimental research of the heat transfer coefficients during evaporation process of R-22 and R-134a in small diameter tubes. The evaporation heat transfer coefficients were measured in smooth horizontal copper tubes with ID 1.77, 3.36 and 5.35 mm. The evaporation heat transfer coefficients in the small diameter tubes (ID <7 mm) were observed to be strongly affected by the size of tube diameters and to differ from those of general predictions in the large diameter tubes. The heat transfer coefficients of ID 1.77 mm copper tube were higher by 20 and 30 % than those of ID 3.36 mm, ID 5.35 mm copper tubes respectively. Also, it was found that it was very difficult to apply some well-known previous predictions (Shah's, Jung's. Kandlikar's and Oh-Katsuda's correlation) to small diameter tubes. Based on the data, the new correlation is proposed to predict the evaporation heat transfer coefficients of R-22 and R-134a in small diameter tubes.

Effect of Sediment Size On Air Injection and Flowing Aspect of Groundwater Saturated Zone (대수층 토양입자크기에 따른 공기분사 흐름 양상)

  • 이준호;박갑성
    • Journal of Soil and Groundwater Environment
    • /
    • v.8 no.3
    • /
    • pp.13-22
    • /
    • 2003
  • Laboratory scale study for an air injection and flowing aspect of groundwater saturated zone was conducted for three sediment grains (AMG 0.34, 1.38, 3.89 mm diameter). Air flow for AMG (Average Modal diameter Grains) 0.34 mm diameter grain size provides indication of pattern of channelized air flow in saturated zone and expansion state in above saturated zone. Maximum area of influence is approximately l5.2%/$\textrm{m}^2$for AMG of 0.34 mm diameter. For AMG of 1.38 mm and 3.89 mm modal diameter grains, air flow are pervasive air flow, forming a symmetrical cone of influence around the injection point. Maximum areas affected are 37%/$\textrm{m}^2$for AMG 1.38 mm diameter and 30%/$\textrm{m}^2$for AMG 3.89 mm diameter. AMG 1.38 mm and 3.89 mm diameter grains show onset of collapse and approach to steady state in above saturated zone, respectively. In this study, optimal sites for in situ air sparging, may be grain diameters between about AMG 1.5-2.5 mm diameter.

현장공기분사공정법(IAS)을 이용한 공기 영향반경과 흐름 양상 연구

  • 이준호;박갑성
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.213-217
    • /
    • 2004
  • Laboratory scale study for an area of influence and flowing aspect of groundwater saturated zone was conducted for three sediment grains. On the AMG(Average Modal diameter Grains) 0.34, 1.38, 3.89mm diameter samples, the affected area of the aquifer were 15.2, 37.0, 30.0%/m2 each. Air flow for AMG 0.34mm diameter grain size provides indication of pattern of channelized air flow in saturated zone and expansion state in above saturated zone. For AMG of 1.38, 3.89mm diameter grains, air flow are pervasive air flow, forming a symmetrical cone of influence around the injection point. And also AMG 1.38, 3.89mm diameter samples show onset of collapse and approach to steady state in above saturated zone, respectively. In this study, optimal sites for in situ air sparging, may be grain diameters between about AMC 1.5~2.5mm diameter.

  • PDF

A Study on the Wide Reach Nozzle of Sprayer(IV) (Characteristics of cap hole diameter and pressure for the medium range nozzle) (휴반용 분무기의 Nozzle에 관한 연구(IV) (중거리용 Nozzle예 있어서 구경과 압력의 특성))

  • 옹장우;이상우
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.17 no.3
    • /
    • pp.3872-3877
    • /
    • 1975
  • This study was conducted to examine the effects of the change of cap hole diameter and pressure on the travelling distance and the sprayed particle size for the medium range nozzle. The results of this study are summarized as follows; 1) The effective travelling distance was about from 1 meter to 8 meters and centro-position of the travelling distance was about 3 or 5 meters. 2) Main effect of change of cap hole diameter for the travelling distance was a slight convex quadratic curve. 3) Main effect of change of pressure increased linearly, its increasing rate about 1.6 was large. 4) Sizes of sprayed particles were less than 250${\mu}$ generally and the sizes decreased according to the increasing of travelling distance. 5) Changes of diameter of sprayed particles by cap hole diameter increased in accordance with increasing of cap hole diameter. 6) Changes of diameter of sprayed particles by the groove depth of swirl plate was very slight.

  • PDF