• Title/Summary/Keyword: diagnostic test

Search Result 1,890, Processing Time 0.03 seconds

Analysis of Insulation Characteristics for High-voltage Motor Stator Winding using Insulation Diagnostic Test (절연진단법을 이용한 고전압전동기 고정자권선의 절연특성분석)

  • Oh, Bong-Keun;Kang, Hyun-Goo;Kim, Hyun-Il;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.404-405
    • /
    • 2009
  • Insulation diagnostic tests for high voltage motor stator winding were conducted to analyze the insulation characteristics. Test motors were manufactured same factory and year(1996). Insulation characteristics of moisture winding are different from those of deteriorative winding. Insulation resistance and disscipation factor test results are sensitive to moisture winding. AC current, disscipation factor tip-up and PD test results are sensitive to deteriorative winding. Also, Capacitance value for stator winding insulation material has characteristic of increasing in moisture winding.

  • PDF

A Study on Diagnostic Validity of Spurling Test Compared to Magnetic Resonance Imaging Findings in Diagnosing Herniated Cervical Intervertebral Disc (경추 추간판 탈출증을 진단함에 있어 경추부 자기공명 영상 소견과 비교한 Spurling test의 진단적 타당성에 대한 연구)

  • Moon, Tae-Woong;Kang, Myung-Jin;Kong, Duck-Hyun;Kim, Jun-Su;Yang, Kee-Young;Lee, Jae-Hoon;Eun, Young-Jun;Kim, Ki-Joo
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.19 no.2
    • /
    • pp.203-212
    • /
    • 2009
  • Objectives : Spurling test is one of the most widely used physical tests to diagnose herniated cervical intervertebral disc. The purpose of this study is to analyse diagnostic validity of Spurling test. Methods : This study was carried out on 382 subjects who visited Bu-Chun Ja-Seng oriental hospital with the neck pain or radiating pain from neck to upper extremities from November, 2007 to October, 2008. All subjects underwent both Spurling test and cervical magnetic resonance imaging(MRI). The associations between Spurling test and herniated cervical intervertebral disc were analysed. Results : 1. The sensitivity of Spurling test for herniated cervical intervertebral disc was 64%. 2. The specificity of Spurling test for herniated cervical intervertebral disc was 86%. 3. The positive predictive value of Spurling test for herniated cervical intervertebral disc was 93%. 4. The negative predictive value of Spurling test for herniated cervical intervertebral disc was 44%. Conclusions : This study suggests that Spurling test is not useful in screening for herniated cervical intervertebral disc due to the test's relatively low sensitivity. Thus it is necessary to consult advanced tests such as diagnostic imaging to diagnose herniated cervical intervertebral disc.

Quality Control of Diagnostic X-ray Units for Animal Hospital (동물병원의 방사선발생장치 정도관리에 대한 연구)

  • Kim, Sang-Woo;Lee, Ji-Hoon;Park, Yei-Seul;Rhim, Jea-Dong;Seoung, Youl-Hun
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2010.04a
    • /
    • pp.231-237
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using quality assurance (QA) and quality control (QC) of diagnostic X-ray units. The surveys for QA/QC, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The QA/QC included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. As a result, 44.44% of reproducibility of dose exposure was proper, 81. 25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test.

  • PDF

Comparison of the lateralization using the activation of the Brocas and the Wernickes area with that of total cortical activation amount of cerebral hemisphere in the functional MR for measuring language lateralization based on Wada test

  • Lee, Sang-Hyun;Chang, Kee-Hyun;Chung, Chun-Kee;Song, In-Chan;Han, Moon-Hee
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.105-105
    • /
    • 2001
  • Purpose: The activation of the Brocas and the Wernickes area in the language functional MR (fMR) well-known phenomena. We want to evaluate correlation of that activation with langua lateralization. So we evaluate the lateralization using the activation of the Brocas and t Wernickes area comparing with total cortical activation amount of cerebral hemisphere in t functional MR for measuring language lateralization based on Wada test.

  • PDF

Evaluation of the Accuracy of the $EasyTest^{TM}$ Malaria Pf/Pan Ag, a Rapid Diagnostic Test, in Uganda

  • Chong, Chom-Kyu;Cho, Pyo Yun;Na, Byoung-Kuk;Ahn, Seong Kyu;Kim, Jin Su;Lee, Jin-Soo;Lee, Sung-Keun;Han, Eun-Taek;Kim, Hak-Yong;Park, Yun-Kyu;Cha, Seok Ho;Kim, Tong-Soo
    • Parasites, Hosts and Diseases
    • /
    • v.52 no.5
    • /
    • pp.501-505
    • /
    • 2014
  • In recent years, rapid diagnostic tests (RDTs) have been widely used for malaria detection, primarily because of their simple operation, fast results, and straightforward interpretation. The Asan $EasyTest^{TM}$ Malaria Pf/Pan Ag is one of the most commonly used malaria RDTs in several countries, including Korea and India. In this study, we tested the diagnostic performance of this RDT in Uganda to evaluate its usefulness for field diagnosis of malaria in this country. Microscopic and PCR analyses, and the Asan $EasyTest^{TM}$ Malaria Pf/Pan Ag rapid diagnostic test, were performed on blood samples from 185 individuals with suspected malaria in several villages in Uganda. Compared to the microscopic analysis, the sensitivity of the RDT to detect malaria infection was 95.8% and 83.3% for Plasmodium falciparum and non-P. falciparum, respectively. Although the diagnostic sensitivity of the RDT decreased when parasitemia was ${\leq}500\;parasites/{\mu}l$, it showed 96.8% sensitivity (98.4% for P. falciparum and 93.8% for non-P. falciparum) in blood samples with parasitemia ${\geq}100\;parasites/{\mu}l$. The specificity of the RDT was 97.3% for P. falciparum and 97.3% for non-P. falciparum. These results collectively suggest that the accuracy of the Asan $EasyTest^{TM}$ Malaria Pf/Pan Ag makes it an effective point-of-care diagnostic tool for malaria in Uganda.

Diagnostic Agents for Oral and Maxillofacial Diseases (구강 질환 진단용 제제)

  • Kho, Hong-Seop
    • Journal of Oral Medicine and Pain
    • /
    • v.24 no.2
    • /
    • pp.181-187
    • /
    • 1999
  • The most important progress in diagnostic sciences is the increased sensitivity and specificity in diagnostic procedures due to the development of newer micromethodologies and increasing availability of immunological and molecular biological reagents. The outcome of researches in this field has already provided DNA probes and antibodies which can be used for diagnosing various kinds of diseases including inherited ones. This development can be also applied to diagnose diseases in oral and maxillofacial regions. Technological advances have yielded highly sensitive test methodologies so that low analyte concentration and small sample volume are no longer limiting factors. Therefore, saliva can be useful test fluid for an array of analytes. Salivary constituents of diagnostic significance include steroid hormones, antibodies, drugs, and tumor markers. Of the proteins present in saliva, viral-specific immunoglobulins are of the greatest diagnostic interest. The development of conjugates and antigens by recombinant DNA technique and peptide synthesis is necessary for clinical application. Several kits developed for the purpose of blood testing should be modified to permit their application to saliva. The final practical outcome of researches in diagnostic sciences will be various diagnostic agents which can be used for detection of bacteria and viruses, screening and diagnosis of diseases, genetic screening for forensic individual identification. For these purposes, collaboration researches and development between institutions and companies are essential.

  • PDF

Development and Effects of Smart Personalized Assessment(SPA) System for Using of Diagnostic and Formative Assessment in Earth Science Classes (지구과학 수업에서 진단 및 형성평가 활용을 위한 스마트 맞춤 평가(SPA) 시스템의 개발 및 효과)

  • Son, Jun Ho;Kim, Jonghee
    • Journal of the Korean Society of Earth Science Education
    • /
    • v.9 no.1
    • /
    • pp.1-14
    • /
    • 2016
  • The purpose of this study is to develop SPA system using diagnostic and formative assessment in earth science classes in order to discuss its effect on learning achievement and self-directed learning attitude. For this purpose, we developed total management system, app for teachers, and app for students. This research was practiced to 76 students in 5th grade. The results are as follows. Firstly, the group taking a class used by app for diagnostic and formative assessment had an effect of improving learning achievement. However, as for learning achievement long term endurance test, the group taking a class using app for diagnostic and formative assessment had no effect. Secondly, the group taking a class using apps for diagnostic and formative assessment had an effect of improving learners' self-directed learning attitude. As for self-directed long-term endurance test, the group taking a class using app for diagnostic and formative assessment had an effect. In conclusion, I hope that this SPA system might apply to the science classes as it is a system that will satisfy the needs of both teachers and students, giving much needed feedback to students.

Diagnostic Value of Immunoglobulin G Anti-Deamidated Gliadin Peptide Antibody for Diagnosis of Pediatric Celiac Disease: A Study from Shiraz, Iran

  • Anbardar, Mohammad Hossein;Haghighi, Fatemeh Golbon;Honar, Naser;Zahmatkeshan, Mozhgan
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.25 no.4
    • /
    • pp.312-320
    • /
    • 2022
  • Purpose: Screening serologic tests are important tools for the diagnosis of celiac disease (CD). Immunoglobulin (Ig)G anti-deamidated gliadin peptide (anti-DGP) is a relatively new autoantibody thought to have good diagnostic accuracy, comparable to that of anti-tissue transglutaminase (anti-tTG) antibody. Methods: Pediatric patients (n=86) with a clinical suspicion of CD were included. Duodenal biopsy, anti-tTG, and IgG anti-DGP antibody tests were performed. The patients were divided into CD and control groups based on the pathological evaluation of duodenal biopsies. The diagnostic accuracy of serological tests was determined. Results: IgA anti-tTG and IgG anti-DGP antibodies were positive in 86.3% and 95.4% of patients, respectively. The sensitivity, specificity, and diagnostic accuracy of the IgA anti-tTG test were 86.3%, 50.0%, and 68.6%, respectively, and those of the IgG anti-DGP test were 95.4%, 85.7%, and 90.7%, respectively. The area under the receiver operating characteristic (ROC) curve was 0.84 (95% confidence interval [CI], 0.74-0.91) for IgA anti-tTG test and 0.93 (95% CI, 0.86-0.97) for IgG anti-DGP test. The comparison of IgA anti-tTG and IgG anti-DGP ROC curves showed a higher sensitivity and specificity of the IgG anti-DGP test. Conclusion: IgG anti-DGP is a reliable serological test for CD diagnosis in children. High tTG and DGP titers in the serum are suggestive of severe duodenal atrophy. The combined use of IgA anti-tTG and IgG anti-DGP tests for the initial screening of CD can improve diagnostic sensitivity.

Assessment of Insulation Aging in 6.6 kV Class High Voltage Motor Stator Windings (6.6 kV급 고압전동기 고정자 권선의 절연열화 평가)

  • Kim, Hee-Dong;Kim, Byong-Han
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.11
    • /
    • pp.1067-1071
    • /
    • 2006
  • Prior to destructive testing, diagnostic tests were performed in ten high voltage motors. Diagnostic tests included polarization infer, ac current, dissipation factor$(tan{\delta})$ and partial discharge magnitude. The rewind of motet slater insulation at rated voltage is assessed by the results of these tests. After completing the diagnostic tests, the stator windings of motors were subjected to gradually increasing ac voltage, until the insulation punctured. No. 8 motor failed near rated voltage of 19.0 kV. The breakdown voltage of No. 4 motet was 7.0 kV which is lower that expected for good quality coils in 6.6 kV class motors. The failure was located in a line-end coil at the exit from the core slot. These two motors began operation in 1994. While testing No. 7 motor, flashover occurred between the stator winding and the stator frame at 15 kV. The relationship between the diagnostic test and the drop in insulation breakdown voltage was analyzed.

Design of a composite diagnostic DC test apparatus for high voltage power cable (고압전력케이블 현장진단시험용 종합 직류시험설비의 검토)

  • Ryoo, Hee-Suk;Kang, Dong-Sik;Sim, Jong-Tae;Lee, Ho-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2326-2328
    • /
    • 1999
  • Developments of effective and economic diagnostic apparatus for industrial plastic insulated high voltage power cables are in discontented condition still. Some report told that DC high voltage was damaged plastic insulation of a partially aged power cable to lead breakdown easily. But now, we have no alternative tools of DC diagnostic apparatus, and we try to reduce a possibility of hazard DC diagnosis. DC diagnostic apparatus still have many advantages to field cable engineer like low price, portability easy applications and sufficient data. Main hazard of DC diagnosis is excessive hight of applied voltage Recent developments for DC diagnosis use considerably low voltage. But new test methods need special measuring device and manipulator, like high input impedance voltmeter, low leakage current high voltage switches, etc. So that reason, new DC diagnostic devices are normally very expensive and have low efficiency, economically. We try to design a composite test device for 3$\sim$4 newly developed method, have economical benefit th industrial engineer.

  • PDF