• Title/Summary/Keyword: device-to-device verification

Search Result 478, Processing Time 0.032 seconds

Development of High Energy X-ray Dose Measuring Device based Ion Chamber for Cargo Container Inspection System (이온전리함 기반의 컨테이너 검색용 고에너지 X-선 선량 측정장치 개발)

  • Lee, Junghee;Lim, Chang Hwy;Park, Jong-Won;Lee, Sang Heon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.12
    • /
    • pp.1711-1717
    • /
    • 2020
  • X-ray of up to 9MeV are used for container inspection. X-ray intensity must be maintained stably regardless of changes in time. If dose is not constant, it may affect the image quality, and as a result, may affect the inspection of abnormal cargo. Therefore, to acquire high-quality images, continuous dose monitoring is required. In this study, the ion-chamber based device was developed for monitoring the dose change in high-energy x-ray. And to estimate the performance of signal-processing device change according to the environmental change, the output changing due to the change of temperature and humidity was observed. In addition, verification of the device was performed by measuring the output change. As a result of the measurement, there was no significant difference in performance due to changes in temperature and humidity, and the change in output according to the change in exposure was linear. Therefore, it was found that the developed device is suitable for the dose monitoring of high-energy x-ray.

Development of Dose Verification Method for In vivo Dosimetry in External Radiotherapy (방사선치료에서 투과선량을 이용한 체내선량 검증프로그램 개발)

  • Hwang, Ui-Jung;Baek, Tae Seong;Yoon, Myonggeun
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.23-30
    • /
    • 2014
  • The purpose of this study is to evaluate the developed dose verification program for in vivo dosimetry based on transit dose in radiotherapy. Five intensity modulated radiotherapy (IMRT) plans of lung cancer patients were used in the irradiation of a homogeneous solid water phantom and anthropomorphic phantom. Transit dose distribution was measured using electronic portal imaging device (EPID) and used for the calculation of in vivo dose in patient. The average passing rate compared with treatment planning system based on a gamma index with a 3% dose and a 3 mm distance-to-dose agreement tolerance limit was 95% for the in vivo dose with the homogeneous phantom, but was reduced to 81.8% for the in vivo dose with the anthropomorphic phantom. This feasibility study suggested that transit dose-based in vivo dosimetry can provide information about the actual dose delivery to patients in the treatment room.

System Performance Improvement of IEEE 802.15.3a By Using Time Slot Synchronization In MAC Layer (UWB MAC의 Time Slot 동기를 통한 시스템 성능 개선)

  • Oh Dae-Gun;Chong Jong-Wha
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.3 s.345
    • /
    • pp.84-94
    • /
    • 2006
  • In this paper, we propose the algorithm to reduce guard time of UWB MAC time slot for throughput gain. In the proposed draft by multiband ofdm alliance (MBOA), Guard time of each medium access slot (MAS) is composed of shortest inter-frame space (SIFS) and MaxDrift which is the time caused by maximum frequency offset among devices. In this paper, to reduceguard time means that we nearly eliminate MaxDrift term from guard time. Each device of a piconet computes relative frequency offset from the device initiating piconet using periodically consecutive transferred beacon frames. Each device add or subtract the calculated relative frequency offset to the estimated each MAS starting point in order to synchronize with calculated MAS starting point of the device initiating piconet. According to verification of simulations, if the frequency offset estimator is implemented with 8 decimal bit, the ratio of the wasted time to Superframe is always less than 0.0001.

Development of Patient-Immobilizing Device for Total Body Irradiation (TBI) (전신 방사선치료(Total Body Irradiation, TBI)를 위한 한국인에 맞는 환자 고정장치에 관한 연구)

  • 김명세
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.114-119
    • /
    • 2002
  • A immobilizing device that is essential for correct lung and lens shielding with homogenous dose distribution in fractionated total body irradiation was developed and it's efficiency was evaluated. The main frame was made of stainless steel bar (5 cm in diameter) to withstand up to 230 cm in height and 100 kg in weight to prevent any injury even in unconsciousness condition. The saddle was designed to adjust the body weight and hight of standing patients. Chest and back supporter were made of 1 cm acryl which could fix the lung block and cassette holder. Leather and sponge pedding were used for head rest to keep patients comfortable. The device was strongly fixed by specially designed bolts on the bottom panel which was made of 1 cm stainless steel and 10 cm thick wooden board. Precise manipulation ($\pm$2 mm) was possible by upper two pulleys and side handles. Average four minutes twenty five seconds were needed for exact setting in fractionated TBI. No significant difference of lung block location on repeated verification films was confirmed and relatively homogeneous dose distribution was measured in rando phantom experiments and patient treatments ($\pm$5%). This immobilizing device was very efficient to keep correct position of patients, which is essential for better result and less complication in fractionated TBI.

  • PDF

The Design and Performance Verification of Real-Time Inspection Equipment Software based on Windows Operating System (윈도우 운영체제 기반의 실시간 점검장비 소프트웨어 설계 및 성능검증)

  • Kim, Hyo-Joung;Heo, Yong-Kwan;Kwon, Byung-Gi
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.10
    • /
    • pp.1-8
    • /
    • 2017
  • As the recent advancement of military equipment has been accelerated, it is becoming more important to act as an inspection device that verifies the performance of equipment in real time. Most of the inspection equipments were developed on the Windows OS based system. considering development convenience and development period. However, sice the data communication between these models occurs asynchronously, there is a problem that it is difficult to guarantee real-time performance of the window-based inspection equiment. To solve these problems, we use real-time commercial solutions to guarantee the real-time performance of Windows-based inspection equipment. In this paper, we propose a method of designing and implementing the inspection equipment software based on Real-Time implanted Kernel-Multi Processor (RTiK-MP) operating in Windows environment. In addition, real-time performance data accuracy was measured through a high-speed communication tool and interlocking test to verify the performance of the inspection device based on the real-time porting kernel.

Design of a Pendulum-type Anti-rolling System for USSV and Verification Based on Roll Damping Coefficient (무인반잠수정의 진자식 횡동요 저감 장치 설계 및 감쇠계수 기반 검증)

  • Jin, Woo-Seok;Kim, Yong-Ho;Jung, Jun-Ho;Lee, Kwangkook;Kim, Dong-Hun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.56 no.6
    • /
    • pp.550-558
    • /
    • 2019
  • The roll motion of a general vessel, which is more influenced by resonance as compared to other motions, adversely affects the passenger and hull. Therefore, reducing the roll motion through an anti-rolling system is critical, and most ships use various devices such as anti-rolling tanks, bilge keels, and fin stabilizers to accomplish this. In this study, a simplified model is developed for the application of an anti-rolling device for unmanned semi-submersible vessels. The applied anti-rolling device is installed on the stern and stem of a ship using a pair of servo motors with added weight, and the motor is controlled through the Arduino. The moment of the motor is designed and implemented based on a mathematical model such that it is calculated through the restoring force according to the heel angle of the ship. The performance of the proposed system was verified by utilizing the roll damping coefficient calculated by the free-roll decay test and logarithmic decrement method and was validated by a towing tank test. The system is expected to be used for unmanned vessels to perform sustainable missions.

Prediction and Evaluation of Power Output for Energy Scavengers using the Piezoelectric Material (압전 재료를 이용한 에너지 변환 시스템의 출력 파워 예측 및 평가)

  • Oh, Jae-Eung;Kim, Seong-Hyeon;Sim, Hyoun-Jin;Lee, Jung-Yoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.827-830
    • /
    • 2006
  • With recent advanced in portable electric devices, wireless sensor, MEMS and bio-Mechanics device, the new typed power supply, not conventional battery but self-powered energy source is needed. Particularly, the system that harvests from their environments are interests for use in self powered devices. For very low powered devices, environmental energy may be enough to use power source. In the generality of cases, these energy harvesting systems are used in the piezoelectric materials as mechanisms to convert mechanical vibration energy into electric energy. Through the piezoelectric materials, the ambient vibration energy could be used to prolong the power supply or in the ideal case provide endless energy f9r the devices. Therefore, the piezoelectric power harvesting cantilever beam is developed. Also, the output voltage and power are predicted in this study. We also discuss the developing system of the piezoelectric energy scavenger. An experimental verification of the model is also performed to ensure its accuracy.

  • PDF

Study on Thermal Analysis for Heating System of Mobile Smart Device Cover Glass Molding Machine (Mobile Smart Device Cover Glass 성형기기의 가열시스템 열해석에 관한 연구)

  • Shin, Hwan June;Lee, Jun Kyoung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.4
    • /
    • pp.50-55
    • /
    • 2014
  • Currently, flat cover glasses are widely applied to mobile devices. However, for a good design and for convenience of use, curved cover glasses are in demand. Thus, many companies are attempting to produce curved cover glasses using a shaving technique, but the production efficiency is very low. Therefore, a molding technique has been adopted to increase the efficiency of curved glass production systems. For a glass molding system, a uniform temperature distribution of the mold is crucial to produce high-quality curved cover glasses. Before setting the heating conditions of the molding system for a uniform temperature distribution by a thermal analysis, verification is required. Therefore, in this study, temperature measurements were conducted for a prototype molding system and the experimental results were compared with simulation computations. The temperatures of the heating block surface were in good agreement with the computational results for transient and steady conditions.

Development on the Process Control System for Full Gate Visual Test of LCD Manufacturing Process (LCD 생산공정의 전게이트 시각 검사를 위한 공정 제어장치 개발)

  • Park, Hyoung-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.7
    • /
    • pp.1725-1728
    • /
    • 2009
  • This research developed process control device and FGV pattern generating device essential for full gate visual inspection to improve process so that defect detection capability may be maximized in specified environment. The devices developed in this research, which can be swiftly replaced in case loss or error occurs, are anticipated to improve module yield as well as maintain tact loss near '0'. In addition, as a result of mounting H/W and S/W system to control detailed operation sequence in production line and executing performance check and verification, detection rates were 98.1% and 99.1% respectively for pixel defect by tact and line defect, and yield of the entire module process including gate and visual level test increased up to 98.3%.

A Study on HILS Test Modeling and Simulation for Telegraph Controller Verification (Telegraph 제어기 검증을 위한 HILS 테스트 모델링 및 시뮬레이션 연구)

  • Kim, Sung-Dong;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.11
    • /
    • pp.1612-1618
    • /
    • 2021
  • The telegraph controller is a device used to control the speed of a ship, and it is a device that has a very direct effect on the safety of the crew. Accordingly, ship owners demand very high reliability of the telegraph controller, and the classification trend is to introduce HILS (hardware in loop system) test as a method to verify reliability. Therefore, in this paper, an electric propulsion ship was modeled to perform the HILS test of the Telegraph controller. For modeling, the specifications of the electric propulsion tug boat were defined, and the battery parts, propulsion motor parts, and ship model parts were modeled. In addition, various operation scenarios were defined and the Telegraph controller was modeled accordingly. Finally, the results of the integrated model were confirmed through simulation.