• Title/Summary/Keyword: developed HPLC/PDA method

Search Result 29, Processing Time 0.02 seconds

Simultaneous Determination of Vitamin A and E in Infant Formula by Rapid Extraction and HPLC with Photodiode Array Detection (신속추출법 및 PDA-HPLC에 의한 조제분유 중 비타민 A, E의 동시분석)

  • Kwak, Byung-Man;Lee, Ki-Woong;Ahn, Jang-Hyuk;Kong, Un-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.189-195
    • /
    • 2004
  • Rapid and simple method was developed for simultaneous determination of vitamins A and E contents in infant formula. Vitamins A and E were extracted by PDA-HPLC with reversed phase column using organic solvent, and their contents in Certified Reference Material (CRM) and infant formula were determined and compared with results of Food Standards Codex and AOAC method for evaluation of developed method, Vitamins A and E contents in CRM determined by developed method were within certified range of standard values. Developed method has great advantages of simple and rapid sample preparation and simultaneous determination of vitamins A and E by PDA-HPLC using reversed phase column.

Simultaneous Determination of the Seven Phenylpropanoids in Xanthii Fructus Using a HPLC-PDA and LC-MS

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Natural Product Sciences
    • /
    • v.24 no.3
    • /
    • pp.206-212
    • /
    • 2018
  • Xanthii Fructus has been traditionally used for the treatment of rhinitis, rheumatoid arthritis, and eczema. In this study, a high-performance liquid chromatography-photodiode array (HPLC-PDA) method was developed and then used for the simultaneous analysis of eight phenylpropanoids in Xanthii Fructus. The analytical column used for this separation was a $SunFire^{TM}$ $C_{18}$ column, maintained at $40^{\circ}C$. The mobile phase used was 1.0% acetic acid in distilled water and 1.0% acetic acid in acetonitrile with gradient elution. For identify of each component, the mass spectrometer (MS) was used a Waters triple quadrupole mass spectrometer requipped with electrospray ionization (ESI) source. The HPLC-PDA method showed good linearity: correlation coefficients were ${\geq}0.9996$. The limits of detection and quantification of the eight compounds were 0.02 - 0.04 and $0.06-0.14{\mu}g/mL$, respectively. The extraction recoveries ranged from 97.51 to 108.67%. The relative standard deviation values of intra- and inter-day precision were 0.06 - 1.55 and 0.09 - 1.68%, respectively. The validated HPLC-PDA method was applied to simultaneously analyse the amounts of eight phenlypropanoids in Xanthii Fructus.

Development of Analytical Method and Validation using HPLC/PDA for Discrimination between Artemisiae Argyi Folium and Artemisiae Iwayomogii Herba

  • Le, Duc Dat;Nguyen, Duc Hung;Zhao, Bing Tian;Min, Byung Sun;Woo, Mi Hee
    • Natural Product Sciences
    • /
    • v.25 no.3
    • /
    • pp.275-283
    • /
    • 2019
  • In this study, we described the new developed method to simultaneously discriminate two herbal drugs of Artemisiae Argyi Folium and Artemisiae Iwayomogii Herba using eight marker compounds (1 - 8) on an HPLC-PDA system. The developed method was applied to quantify the major components of two herbal drugs. The pattern analysis successfully discriminated and evaluated different components between Artemisiae Argyi Folium and Artemisiae Iwayomogii Herba. Results were used for classification of different species from collected samples.

Simultaneous Analysis of Liquiritin and Glycyrrhizin in Sagunja-tang by HPLC-PDA (HPLC-PDA에 의한 사군자탕 중 Liquiritin과 Glycyrrhizin의 동시분석)

  • Seo, Chang-Seob;Kim, Jung-Hoon;Shin, Hyeun-Kyoo
    • Korean Journal of Pharmacognosy
    • /
    • v.42 no.3
    • /
    • pp.240-245
    • /
    • 2011
  • A high-performance liquid chromatography (HPLC) method was developed for quantitative analysis of liquiritin and glycyrrhizin in Sagunja-tang (SGT, Sijunzi-tang in Chinese), a traditional Korean medicine. HPLC analysis was performed using a Gemini C18 column operating at $40^{\circ}C$, and photodiode array (PDA) detection at 254 nm and 280 nm for quantification of the two components in SGT. The mobile phase using a gradient flow consisted of two solvent systems. Solvent A was 1.0% (v/v) aqueous acetic acid and solvent B was acetonitrile with 1.0% (v/v) acetic acid. Calibration curves were acquired with $r^2$ values > 0.9998, and the relative standard deviations (RSDs, %) for intra- and inter-day precision were not exceed 4.0%. The recovery of each component was in the range of 91.85 - 108.62%, with a RSD less than 4.0%. The contents of the two components in SGT were 7.94 - 13.83 mg/g.

Quantitation and Radical Scavenging Activity Evaluation of Iridoids and Phenylethanoids from the Roots of Phlomis umbrosa (Turcz.) using DPPH Free Radical and DPPH-HPLC Methods, and their Cytotoxicity

  • Le, Duc Dat;Nguyen, Duc Hung;Zhao, Bing Tian;Min, Byung Sun;Song, Si Whan;Woo, Mi Hee
    • Natural Product Sciences
    • /
    • v.25 no.2
    • /
    • pp.122-129
    • /
    • 2019
  • The roots of Phlomis umbrosa (Turcz.) (Phlomidis Radix) have been traditionally used to treat cold, reduce swelling and staunch bleeding. Four iridoids (1 - 3 and 5) and six phenylethanoid derivatives (4, and 6 - 10) were isolated from the roots of P. umbrosa. A simple, sensitive, and reliable analytical HPLC/PDA method was developed, validated, and applied to determine 10 marker compounds in Phlomidis Radix. Furthermore, the isolates were evaluated for cytotoxic and anti-oxidant activities as well as DPPH-HPLC method. Among them, compounds 4 and 6 - 9 displayed potent anti-oxidant capacities using DPPH assay with $IC_{50}$ values of $27.7{\pm}2.4$, $10.2{\pm}1.1$, $18.0{\pm}0.8$, $19.1{\pm}0.3$, and $19.9{\pm}0.6{\mu}M$, and compounds 6, 8, and 9 displayed significant cytotoxic activity against HL-60 with $IC_{50}$ values of $35.4{\pm}3.1$, $18.6{\pm}2.0$, and $42.9{\pm}3.0{\mu}M$, respectively.

Development of an analytical method for the quantification of oleanonic acid from mastic gum using HPLC/PDA

  • Hak-Dong Lee;Chang-Dae Lee;So Yeon Choi;Sanghyun Lee
    • Journal of Applied Biological Chemistry
    • /
    • v.66
    • /
    • pp.67-72
    • /
    • 2023
  • A simple and accurate method was developed for the quantitative analysis of oleanonic acid (OA) from mastic gum. The analysis was carried out using reverse-phase high-performance liquid chromatography combined with a photodiode array detector (HPLC/PDA). Our optimized method was validated by measuring various parameters, using an INNO C18 column fitted with a gradient elution system. The results revealed limits of detection and quantification of 0.34 and 1.042 ㎍/mL, respectively. The OA calibration curve exhibited excellent linearity over the concentration range of 0.0625 to 2.0 mg/mL, with r2 =0.9996. Accuracy tests revealed a high recovery rate of 99.44-103.66%, with precision values below 0.15%. These results suggest that the present analytical method can identify and quantify OA in mastic gum with high precision. The HPLC approach developed in this study might be applied to routine analyses and large-scale extraction procedures for OA content quantification.

Development and Validation of HPLC-PDA Method and Pattern Recognition Analyses Using Eight Marker Compounds for the Quality Control Between the Seeds of Cuscuta chinensis Lam. and Cuscuta japonica Choisy

  • Nguyen, Duc Hung;Zhao, Bing Tian;Le, Duc Dat;Ma, Eun Sook;Min, Byung Sun;Woo, Mi Hee
    • Natural Product Sciences
    • /
    • v.25 no.4
    • /
    • pp.334-340
    • /
    • 2019
  • Cuscuta chinensis Lam. and Cuscuta japonica Choisy are parasitic plants. C. chinensis seeds were traditionally used for treatment of kidney and liver deficiencies. C. japonica seeds were used as tonic medicine to improve liver function and strengthen kidneys, treatment of high blood pressure, chronic diarrhea, and sore eyes. Cuscutae Semen are seeds of only C. chinensis in Korean Herbal Pharmacopoeia (K.H.P.). The developed HPLC-PDA method easily, accurately, and sensitively quantified using eight marker compounds [hyperoside (1), astragalin, (2), quercetin (3), kaempferol (4), chlorogenic acid (5), 3,4-di-O-caffeoylquinic acid (6), 1,5-di-O-caffeoylquinic acid (7), and 4,5-di-O-caffeoylquinic acid (8)]. In addition, the method may be used to distinguish seeds between C. chinensis Lam. and C. japonica Choisy. Furthermore, the result from the current study was applied to clarify samples between steam processed and unprocessed samples of C. chinensis by pattern analysis.

Development of simultaneous determination of vitamin A and E in infant formula by micro-HPLC (Micro-HPLC를 이용한 조제분유 중 비타민 A.E 동시분석법 개발)

  • Yun I-Ran;Choi You-Jeong;Lee Min-Kwon;Jeong Myeong-Ho;Kim Byeong-Hun
    • Korean Journal of Veterinary Service
    • /
    • v.29 no.3
    • /
    • pp.339-346
    • /
    • 2006
  • Semi-micro-HPLC using a column-switching technique was developed for simultaneous determination of vitamin A and E contents in infant formula. Vitamin A and E were extracted by PDA - HPLC with reversed phase column using organic solvent and their contents in Certified Reference Material (CRM) and infant formula were determined and compared with hydrolysis method and rapid extraction. Developed method has many advantages of simple and rapid sample preparation and simultaneous determination of vitamin A and E by micro-HPLC using reversed phase column.

A Study for Analytical Method of Sudan Colorants in Foods (식품 중 수단색소의 분석법에 관한 연구)

  • 김희연;윤혜정;최장덕;최우정;박선영;이경주;김지혜
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.3
    • /
    • pp.549-552
    • /
    • 2004
  • A simple, efficient and accurate method was developed for the simultaneous determination of non-permitted oil soluble colorants (sudan I, II, III and IV) in foods. The identification has been carried out for sudan colorants by TLC as well as HPLC with photodiode array (PDA) detection. Separation of sudan colorants was achieved within 20 min by a gradient elution with water and acetonitrile as eluents. Sudan colorants showed good linear relationships in the range of 0.1 ~ 100 $\mu\textrm{g}$/mL. The correlation coefficients of the calibration curve for sudan colorants exceeded 0.999. The detection limits (signal-to-noise ratio 3 : 1) for sudan I, II, III and IV were 0.01, 0.01, 0.02 and 0.02 $\mu\textrm{g}$/mL, respectively. This method has been successfully applied to the analysis of red pepper powder, Kimchi and Kakdugi, and the average recoveries for real samples ranged from 83.02% to 104.3%.

Determination of eugenol in Eugenia caryophyllata by high-performance Liquid chromatography with photodiode array detection and method validation (HPLC-PDA를 이용한 정향(Eugenia caryophyllata) 중의 eugenol 분석법 확립 및 검증)

  • Yun, Hyeong-Jun;Yun, So-Mi;Lee, Myoung-Heon;Son, Seong-Wan
    • Korean Journal of Veterinary Research
    • /
    • v.48 no.1
    • /
    • pp.9-16
    • /
    • 2008
  • A method for the quantification of eugenol in the medicinal herb Clove was developed and validated. For preparation of sample solutions clove was dried at $60^{\circ}C$ for 2h and ground by mixer and extracted with 95% ethanol for shaking extraction. The elutes were analyzed by HPLC system included a reversed phase column, a isocratic mobile phase of 60% methanol and PDA detector set at 280 nm. Calibration graphs were linear with very good correlation coefficients ($r^2>0.9999$) from $0.0125~1{\mu}g/ml$. The limit of detection per sample injection ($20{\mu}l$) was $0.81ng/{\mu}l$ and limit of quantification was $2.47ng/{\mu}l$. The method showed good intra-day precision (%RSD 0.08 ~ 0.27%) and inter-day precision (%RSD 0.32 ~ 1.19%).