• Title/Summary/Keyword: detector combination

Search Result 119, Processing Time 0.027 seconds

Development and Evaluation of an Immunochromatographic Assay for Screening Listeria spp. in Pork and Milk

  • Kim, Seong-Hee;Kim, Jin-Young;Han, Woong;Jung, Byeong-Yeal;Chuong, Pham-Due;Joo, Hae-Jin;Ba, Hoa-Van;Son, Won-Geun;Jee, Young-Heun;Yoon, Byoung-Su;Lee, Yong-Soon;Lim, Yoon-Kyu
    • Food Science and Biotechnology
    • /
    • v.16 no.4
    • /
    • pp.515-519
    • /
    • 2007
  • Rapid immunochromatographic assay (ICA) kits were developed using flagella-specific monoclonal antibodies (MAbs) and rabbit polyclonal antibodies for screening Listeria spp. in food. The establishment of different formats, MAb 2B1 as capture antibody and MAb 7A3 or rabbit polyclonal antibodies as detector antibody, was compared. The 2 formats of the ICA kit were shown to have specific reactions with Listeria and no cross-reactivity with any of the non-Listeria including Escherichia coli O157:H7 and Salmonella enteritidis. The detection limits of the ICA kit using the combination of gold-labeled MAb 7A3 and MAb 2B1 showed $1{\times}10^5$ and $1{\times}10^6\;CFU/0.1\;mL$ at 22 and $30^{\circ}C$, respectively. The other format of the ICA kit using the combination of gold-labeled rabbit polyclonal antibodies and MAb 2B1 showed $1{\times}10^6\;CFU/0.1\;mL$ at $22^{\circ}C$ but weak signal at 30 culture. The format utilizing MAb was more sensitive than the one using polyclonal antibodies for capture antibody. Samples contaminated with L. monocytogenes 4b culture (9-10, 5-6, and 1-2 CFU/mL) on pork and pasteurized milk were confirmed as positive results. Current data suggests that this ICA kit is a rapid, simple and effective tool to screen for Listeria spp. in food.

Hydrocarbon Speciation in Low Temperature Diesel Combustion (저온 디젤 연소에서 발생하는 탄화수소 종 분석)

  • Han, Man-Bae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.4
    • /
    • pp.417-422
    • /
    • 2010
  • Low temperature diesel combustion was achieved via a combination of late injection timing ($8.5^{\circ}$ CA BTDC to $0.5^{\circ}$ CA BTDC) and heavy exhaust gas recirculation (37% to 48%) with ultra low sulfur Swedish diesel fuel in a 1.7L common rail direct injection diesel engine. When injection timing is retarded at a certain exhaust gas recirculation rate, the particulate matter and nitrogen oxides decease simultaneously, while the hydrocarbon and carbon monoxide increase. Hydrocarbon speciation by gas chromatography using a flame ionization detector reveals that the ratio of partially burned hydrocarbon, i.e., mainly alkenes increase as the injection timing is retarded and exhaust gas recirculation is increased. The two most abundant hydrocarbon species are ethene which is a representative species of partially burned hydrocarbons, and n-undecane, which is a representative species of unburned hydrocarbons. They may be used as surrogate hydrocarbon species for performing a bench flow reactor test for catalyst development.

Investigation of Radiation Effects on the Signal and Noise Characteristics in Digital Radiography (디지털 래디오그라피의 신호 및 잡음 특성에 대한 방사선 영향에 관한 연구)

  • Kim, Ho-Kyung;Cho, Min-Kook;Graeve, Thorsten
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.756-767
    • /
    • 2007
  • For the combination of phosphor screens having various thicknesses and a photodiode array manufactured by complementary metal-oxide-semiconductor (CMOS) process, we report the observation of image-quality degradation under the irradiation of 45-kVp spectrum x rays. The image quality was assessed in terms of dark pixel signal, dynamic range, modulation-transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). For the accumulation of the absorbed dose, the radiation-induced increase both in dark signal and noise resulted in the gradual reduction in dynamic range. While the MTF was only slightly affected by the total ionizing dose, the noise power in the case of $Min-R^{TM}$ screen, which is the thinnest one among the considered screens in this study, became larger as the total dose was increased. This is caused by incomplete correction of the dark current fixed-pattern noise. In addition, the increase tendency in NPS was independent of the spatial frequency. For the cascaded model analysis, the additional noise source is from direct absorption of x-ray photons. The change in NPS with respect to the total dose degrades the DQE. However, with carefully updated and applied correction, we can overcome the detrimental effects of increased dark current on NPS and DQE. This study gives an initial motivation that the periodic monitoring of the image-quality degradation is an important issue for the long-term and healthy use of digital x-ray imaging detectors.

ANALYSIS OF GRAVITATIONAL WAVE EXPERIMENTAL DATA WITH DISTRIBUTED COMPUTING (분산 컴퓨팅을 이용한 중력파 검출을 위한 데이터 분석)

  • Lim, Soo-Il;Lee, Hyung-Mok;Kim, Jin-Ho;Oh, Sang-Hoon;Lee, Sang-Min
    • Publications of The Korean Astronomical Society
    • /
    • v.22 no.2
    • /
    • pp.43-54
    • /
    • 2007
  • Many gravitational wave detectors are now being built or under operation throughout the world. In particular, LIGO has taken scientific data several times, although current sensitivity is not sufficient to detect the weak signals routinely. However, the sensitivities have been improving steadily over past years so that the real detection will take place in the near future. Data analysis is another important area in detecting the gravitational wave signal. We have carried out the basic research in order to implement data analysis software in Korea@home environment. We first studied the LIGO Science Collaboration Algorithm Library(LAL) software package, and extracted the module that can generate the virtual data of gravitational wave detector. Since burst sources such as merging binaries of neutron stars and black holes are likely to be detected first, we have concentrated on the simulation of such signals. This module can generate pure gravitational wave forms, noise suitable for LIGO, and combination of the signal and noise. In order to detect the gravitational signal embedded in the noisy data, we have written a simple program that employs 'matched filtering' method which is very effective in detecting the signal with known waveform. We found that this method works extremely well.

Vital Sign Sensor Based on Second Harmonic Frequency Drift of Oscillator (발진기의 2채배 고조파 주파수 천이를 이용한 생체신호 측정센서)

  • Ku, Ki-Young;Hong, Yunseog;Lee, Hee-Jo;Yun, Gi-Ho;Yook, Jong-Gwan;Kim, Kang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.3
    • /
    • pp.299-306
    • /
    • 2016
  • In this paper, a vital sign sensor based on impedance variation of resonator is proposed to detect the respiration and heartbeat signals within near-field range as a function of the separation distance between resonator and subject. The sensor consists of an oscillator with a built-in planar type patch resonator, a diplexer for only pass the second harmonic frequency, amplifier, SAW filter, and RF detector. The cardiac activity of a subject such as respiration and heartbeat causes the variation of the oscillation frequency corresponding impedance variation of the resonator within near-field range. The combination of the second harmonic oscillation frequency deviation and the superior skirt frequency of the SAW filter enables the proposed sensor to extend twice detection range. The experimental results reveal that the proposed sensor placed 40 mm away from a subject can reliably detect respiration and heartbeat signals.

New Speech Enhancement Method using Psychoacoustic Criteria (심리 음향 기준을 이용한 새로운 음질 개선 방법)

  • 김대경;박장식;손경식
    • Journal of Korea Multimedia Society
    • /
    • v.4 no.1
    • /
    • pp.56-66
    • /
    • 2001
  • The spectral subtraction algorithm using a criterion based on the human perception has been recently developed. The speech processed with Virag's algorithm sounds more pleasant to a human listener than those obtained by the classical methods. However, Virag's algorithm requires a robust voice activity detector (VAD). In the ESS (extended spectral subtraction) algorithm without VAD, the residual noise becomes more noticeable as the SNR decrease. In this paper we propose a new speech enhancement method, the combination of Wiener filter and spectral subtraction based on noise masking characteristics in the human auditory system. There is no need of VAD because the noise can be successively updated even during speech activity using Wiener filter. The adjustment of the subtraction parameter based on the masking threshold makes the residual noise inaudible. The proposed method has been compared with conventional spectral subtraction algorithms. Objective and subjective evaluation of the proposed system is performed with several noise types having different time-frequency distributions. The application of objective measures, the study of the speech spectrograms, as well as subjective listening tests, confirm that the enhanced speech with proposed algorithm is more pleasant to a human listener.

  • PDF

Comparison of Sampling and Analytical Methods for Determining Airborne Hexavalent Chromium -Limit of Detection, Accuracy and Precision of Analytical Procedures (공기중 6가 크롬 측정 방법 비교 -검출한계, 정확도 및 정밀도-)

  • 신용철;이병규;이지태
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.1
    • /
    • pp.39-49
    • /
    • 2002
  • In this study, limits of detection (LOD), accuracy and precision of four sampling/ analytical methods were evaluated and compared for the determination of airborne hexavalent chromium, Cr (VI). The methods include : (1) a combination of the National Institute for Occupational Safety and Health (NIOSH) Method 7600/U. S. Environmental Protection Agency (EPA) Method 218.6 (NIOSH/EPA Method) proposed by Shin and Paik, 2) two impinger methods using 2% NaOH/3% Na$_2$CO$_3$. (3) same as (2) but with 0.02 N NaHCO$_3$absorbing solution, and (4) the Occupational Safety and Health (OSHA) Method ID-215. An ion chromatograph/visible absorbance detector was used for the analysis of Cr (VI) in sample solution. Limit of detection (LOD) , analytical accuracy, and precision were also tested using Cr (VI) spike samples. Recoveries (as index of accuracy) and coefficient of variation (CV) (as a index of precision) were determined. Two-way ANOVA and Turkey's test were performed to test the significance in differences among recoveries and CVs of the methods. In all the methods, the peaks of Cr (VI) were separated sharply on chromatograms and exhibited a strong linearity with Cr (VI) concentrations in solution. The correlation coefficients of calibration curves typically ranged from 0.9997 to 0.9999, and the analytical LODs from 0.025 to 0.1$\mu\textrm{g}$/sample. All the method had good sensitivities and linearities between Cr (VI) levels and peak areas. The accuracies (% mean recoveries) of the methods ranged from 80.1 to 104.2%, while the precisions (pooled coefficient of variation) ranged from 3.16 to 4.43%. The impinger methods showed higher recoveries ( > 95%) than those of the PVC filter methods (the OSHA Method and the NIOSH/EPA Method). It was assumed that Cr (VI) on PVC filter was exposed to air and reduced to trivalent chromium, Cr (III), whereas it was stabilized in alkali solution contained in impinger. Thus, a special treatment of Cr (VI) samples collected on PVC filters may be required.

Effectiveness of Bioremediation on Oil-Contaminated Sand in Intertidal Zone

  • Oh, Young-Sook;Sim, Doo-Suep;Kim, Sang-Jin
    • Journal of Microbiology and Biotechnology
    • /
    • v.13 no.3
    • /
    • pp.437-443
    • /
    • 2003
  • Bioremediation technologies were applied to experimental microcosms, simulating an oil spill in a lower intertidal area. Three treatments (oil only, oil plus nutrients, and oil plus nutrients and microbial inocula) were applied, and each microcosm was repeatedly filled and eluted with seawater every 12 h to simulate tidal cycles. To minimize washing-out of the inoculum by the tidal cycles, microbial cells were primarily immobilized on diatomaceous earth before they were applied to the oiled sand. Oil degradation was monitored by gravimetric measurements, thin layer chromatography/flame ionization detector (TLC/FID) analysis, and gas chromatography (GC) analysis, and the loss of oil content was normalized to sand mass or nor-hopane. When the data were normalized to sand mass, no consistent differences were detected between nutrient-amended and nutrient/inoculum-amended microcosms, although both differed from the oil-only microcosm in respect of oil removal rate by a factor of 4 to 14. However, the data relative to nor-hopane showed a significant treatment difference between the nutrient-amended and nutrient/inoculum-treated microcosms, especially in the early phase of the treatment. The accelerating effect of inoculum treatment has hardly been reported in studies of oil bioremediation in the Tower intertidal area. The inoculum immobilized on diatomaceous earth seemed to be a very effective formulation for retaining microbial cells in association with the sand. Results of this study also suggest that interpretation of the effectiveness of bioremediation could be dependent on the selection of monitoring methods, and consequently the application of various analytical methods in combination could be a solution to overcome the limitations of oil bioremediation monitoring.

Signal Energy-based Cyclostationary Spectrum Sensing for Wireless Sensor Networks (무선센서네트워크를 위한 신호 에너지 기반 사이클로스테이셔너리 스펙트럼 검출)

  • Nguyen, Quoc Kien;Jeon, Taehyun
    • Journal of Satellite, Information and Communications
    • /
    • v.11 no.3
    • /
    • pp.119-122
    • /
    • 2016
  • Feature detection is recognized as an accurate spectrum sensing approach when the information of the desired signal is partly known at the receiver. This type of detection was proposed to overcome large noise environment. Cyclostationary detection is an example of feature detection in spectrum sensing technique in cognitive radio. However, the cyclostationary process calculation requires a lot of processing time and information about the designed signals. On the other hand, energy detection spectrum sensing is widely known as a simple and compact spectrum sensing technique. However, energy detection is highly affected by large noise and lead to high detection error probability. In this paper, the combination of energy detection and cyclostationary is proposed in order to increase the accuracy and decrease the calculation and processing time. The two-layer threshold is utilized in order to reduce the complexity of computation and processing time in cyclostationary which can lead to the improved throughput of the system. The simulation result shows that the implementation of energy-based cyclostationary detector can help to improve the performance of the system while it can considerably reduce the required time for signal detection.

Effect of Xeroderma Pigmentosum Complementation Group F Polymorphisms on Gastric Cancer Risk and Associations with H.pylori Infection

  • Zhang, Ji-Shun;Zhang, Chuan;Yan, Xue-Yan;Yuan, Zhi-Fang;Duan, Zhuo-Yang;Gao, Hui
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.3
    • /
    • pp.1847-1850
    • /
    • 2013
  • We conducted a hospital case-control study by genotyping four potential functional single nucleotide polymorphisms (SNPs) to assess the association of Xeroderma pigmentosum complementation group F (XPF) with gastric cancer susceptibility, and role of XPF polymorphisms in combination with H.pylori infection in risk definition. A total of 331 patients with gastric cancer and 355 controls were collected. Four SNPs of XPF, rs180067, rs1799801, rs2276466 and rs744154, were genotyped by Taqman real-time PCR method with a 7900 HT sequence detector system. The gastric cancer patients were more likely to have smoking habit, a family history of cancer and H.pylori infection. We did not find any significant difference in the genotype distributions of XPF rs180067, rs1799801, rs2276466 and rs744154 between cases and controls. However, multivariate logistic analysis showed a non-significant decreased risk in patients carrying rs180067 G allele, rs1799801 T allele or rs2276466 T allele genotypes. A non-significant increased risk of gastric cancer was found in individuals carrying the rs744154 GG genotype. Stratification by H.pylori infection and smoking was not significantly different in polymorphisms of XPF rs180067, rs1799801, rs2276466 and rs744154. The four XPF SNPs did not show significant interaction with H.pylori infection and smoking status (P for interaction was 0.35 and 0.18, respectively). Our study indicated that polymorphisms in rs180067, rs1799801, rs2276466 and rs744154 may affect the risk of gastric cancer but further large sample size studies are needed to validate any association.