• Title/Summary/Keyword: depth radiation

Search Result 637, Processing Time 0.029 seconds

Comparison of Air Kerma­based and Absorbed Dose to Water­based Protocols in the Dosimetry of High Energy Electron Beams (고 에너지 전자선에 대한 공기커마와 물 흡수선량에 기반한 프로토콜간의 비교)

  • 박창현;신동오;박성용
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.249-258
    • /
    • 2003
  • A few years ago, a proposal was made to change the dosimetry from the air kerma-based reference dosimetry to the absorbed dose-based reference dosimetry for all radiotherapy beams of ionizing radiation to improve the accuracy of dosimetry. Here, we present a dosimetry study in which the two most widespread absorbed dose­based protocols (IAEA TRS­398 and AAPM TG­51) were compared with an air kerma­based protocol (IAEA TRS-277) by measuring the absorbed dose in the same reference depth. Measurements were performed in three clinical electron beam energies using a PTW 30002 cylindrical chamber, and Markus and Roos plane­parallel chambers. $^{60}$ Co calibration factors were obtained from the KFDA. The absorbed dose differences between the air kerma­based and absorbed dose­based protocols were within 2.0% for all chambers in all beams. The results thus show that the obtained absolute dose values will be not significantly altered by changing from the air kerma­based dosimetry to the absorbed dose­based dosimetry. It was also shown that absorbed dose values between the absorbed dose­based protocols agreed by deviations of less than 0.5% for a cylindrical chamber and less than 0.7% for plane­parallel chambers using cross­calibration factors. Although the use of a cylindrical chamber and plane­parallel chambers resulted in a difference of less than 2% for all situations investigated here, to reduce errors, the plane­parallel chambers are recommended for electron energies in which the use of cylindrical chamber is not permitted in each protocol.

  • PDF

Beta Dosimetry for Applying $^{166}Ho$-chitosan Complex to Cystic Brain Tumor Treatment : Monte Carlo Simulations Using a Spherical Model ($^{166}Ho$-chitosan 복합체를 이용한 낭성뇌종양 치료를 위한 베타선의 흡수선량 평가 : 구형 모델을 이용한 Monte Cairo 모사계산)

  • Kim, Eun-Hee;Rhee, Chang-Hun;Lim, Sang-Moo;Park, Kyung-Bae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.4
    • /
    • pp.433-439
    • /
    • 1997
  • $^{166}Ho$-chitosan complex, or $^{166}Ho$-CHICO, is a candidate pharmaceutical for intracavitary radiation therapy of cystic brain tumors because of the desirable nuclear characteristics of $^{166}Ho$ for therapeutic use and the suitable biological and chemical characteristics of chitosan, not to mention its ready producibility The amount of $^{166}Ho$-CHICO to be administered to obtain the goal therapeutic effect can be suggested by predicting the dose to the cyst wall for a varying pharmaceutical dose. When $^{166}Ho$-CHICO is infused into the cyst, the major part of the energy delivery by beta particles emitted from $^{166}Ho$ occurs in the cyst wall within 4mm in depth from the cyst wall surface. Also, realizing the attachment of $^{166}Ho$-CHICO to the cyst wall surface would change the predictions of dose to the cyst wall.

  • PDF

Analysis of the Respiratory Motion Effects on Dose Distribution Using TLD Phantom (열형광선량계용 팬톰을 이용한 호흡 움직임에 따른 선량분포의 평가)

  • Hong, Ju-Young;Kim, Yon-Lae;Rah, Jeong-Eun;Chung, Jin-Beom;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.187-191
    • /
    • 2006
  • The purpose of this study was to measure the dose distribution from the moving phantom for the respiratory motion. The phantom for TLD measurement was designed and built for this study based on the multiple plates for placing TLD and film. The TLDs may be inserted at 3 mm intervals in each TLD plate. For the measurements, TLD plate was inserted into the phantom at 1.5 cm ($d_{max}$) depth, and phantom was allowed to move in SI directions in the range of 1 to 2 cm with 0.5 cm interval for 6 MV X-ray beams. Penumbra and FWHM were measured at both moving state and compared stationary. It was found that penumbra increased 0.71 cm at stationary and 2.10 cm at moving state in 2 cm movement, and that FWHM are 7.52 cm for stationary state and 7.02 cm for moving state (2 cm movement). In this study, film was used to compared with TLD results of measurements and simitar results were observed. Therefore, it is expected that TLD moving phantom may be useful for the treatment of tumors that move due to the respiratory motion.

  • PDF

Application and Analysis of the Steady State Spectral Wave Model Take into Account the Effect of Current (흐름의 영향을 고려한 정상상태 스펙트럼 파랑모델의 적용 및 분석)

  • Lee, Hak-Seung;Lee, Joong-Woo;Yang, Sang-Yong
    • Journal of Navigation and Port Research
    • /
    • v.28 no.1
    • /
    • pp.97-104
    • /
    • 2004
  • Introduction of wave model, take into account the effect of tide, wind and wave induced currents at the coastal waters of complex bathymetry, is a very important factor for most coastal engineering design and disaster protection problems. As the steady state spectral wave model could simulate depth induced wave shoaling and refraction, current induced refraction effect, steepness induced wave breaking, diffraction, wind wave growth, wave-wave interaction, and wave-current interaction that redistribute energy, this would support and compensate the gap in the real field of design where other wave models could not deal and cause wrong estimation. In this study, for better understanding and analysis of wave transformation process, we applied the spectral wave model to the large coastal waters near Gaduck Island where the Busan new port construction project is going on. We also compared the simulation results with the calculatea from the existing model. From such a trial of this study, we hope that broader and safer use of the spectral model in the area of port design and disaster prevention system come through in near future.

THE NONDESTRUCTIVE MEASUREMENT OF THE SOLUBLE SOLID AND ACID CONTENTS OF INTACT PEACH USING VIS/NIR TRANSMITTANCE SPECTRA

  • Hwang, I.G.;Noh, S.H.;Lee, H.Y.;Yang, S.B.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.210-218
    • /
    • 2000
  • Since the SSC(soluble solid contents) and titratable acidity of fruit are highly concerned to the taste, the need for measuring them by non-destructive technology such as NIR(Visual and Near-infrared) spectroscopy is increasing. Specially, in order to grade the quality of each fruit with a sorter at sorting and packing facilities, technologies for online measurement satisfying the tolerance in terms of accuracy and speed should be developed. Many researches have been done to develop devices to measure the internal qualities of fruit such as SSC, titratable acidity, firmness, etc. with the VIS(Visual)/NIR(Near Infrared) reflectance spectra. The distributions of the SSC, titratable acidity, firmness, etc. are different with respect to the position and depth of fruit, and generally the VIS/NIR light can interact with fruit in a few millimeters of pathlength, and it is very difficult to measure the qualities of inner flesh of fruit. Therefore, to measure the average concentrations of each quality factor such as SSC and titratable acidity with the reflectance-type NIR devices, the spectra of fruit at several positions should be measured. Recently, the interest about the transmittance-type VIS/NIR devices is increasing. NIR light can penetrate through the fruit about 1/10-1/1,000,000 %. Therefore, very intensive light source and very sensitive sensor should be adopted to measure the transmitted light spectra of intact fruit. The ultimate purpose of this study was to develop a device to measure the transmitted light spectra of intact fruit such as apple, pear, peach, etc. With the transmittance-type VIS/NIR device, the feasibility of measurement of the SSC and titratable acidity in intact fruit cultivated in Korea was tested. The results are summarized as follows; A simple measurement device which can measure the transmitted light spectra of intact fruit was constructed with sample holder, two 500W-tungsten halogen lamps, a real-time spectrometer having a very sensitive CCD array sensor and optical fiber probe. With the device, it was possible to measure the transmitted light spectra of intact fruit such as apple, pear and peach. Main factors affecting the intensity of transmitted light spectra were the size of sample, the radiation intensity of light source and the integration time of the detector. Sample holder should be designed so that direct light leakage to the probe could be protected. Preprocessing method to the raw spectrum data significantly influenced the performance of the nondestructive measurement of SSC and titratable acidity of intact fruit. Representative results of PLS models in predicting the SSC of peach were SEP of 0.558 Brix% and R2 of 0.819, and those in predicting titratable acidity were SEP of 0.056% and R2 of 0.655.

  • PDF

Soil Evaporation Evaluation Using Soil Moisture Measurements at a Hillslope on a Mountainous Forest (산림 사면에서 실측 토양수분을 이용한 토양증발평가)

  • Gwak, Yong-Seok;Kim, Sang-Hyun
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.6
    • /
    • pp.557-568
    • /
    • 2012
  • In order to understand the hydrological processes on the mountainous forest, the configuration of soil evaporation (E) out of evapotranspiration (ET) is a challenging and important topic. In this study, we attempted to understand the soil evaporation process for a humid forest hillslope via measuring and analyzing soil moistures with a sampling interval in 2 hours at three locations for 10 days between May 22th and 31th 2009. Two methods were used to estimate soil evaporation in every 2hr; one is a method using soil moisture measurement ($E_{SM}$), the others methods are based on Penman equation (Penman (1948), Staple (1974), Konukcu (2007), Equilibrium Penman ($E_{equili}$)). As a critical parameter in determining $E_{SM}$, the dry surface layer (DSL), was estimated using energy balance equation. The accumulated soil evaporation ($E_{SM}$) of A, B, C points were estimated as 2.09, 1.08 and 2.88 mm, respectively. The estimated evaporation of Penman (1948), Staple (1974), Konukcu (2007), $E_{equili}$ were 4.91, 8.80, 8.63 and 3.28 mm. The proposed method with soil moisture measurement showed lower soil evaporations than the other conventional methods. The increasing soil temperature and interaction between soil and atmosphere due to existence of litter and DSL are considered as dominant factors for soil evaporation. The $E_{SM}$ has the apparent lag time between 2 and 4 hr compared with $E_{equili}$ and net radiation. The DSL and surface resistance ($r_s$) were increased as soil moisture was decreased for in this study. The estimated DSL through the temporal distribution analysis of soil moisture and tension measurements was also similar to that of the energy balance relationship.

A Study on the Performance of Flat-plate Solar Air Collector and its Application to Grain Drying (평면식 태양열집열기를 이용한 곡물 건조개선에 관한 연구)

  • 민영봉;최규홍
    • Journal of Biosystems Engineering
    • /
    • v.3 no.2
    • /
    • pp.114-125
    • /
    • 1978
  • The use of petroleum fuels in grain drying causes problems of high cost and management. To solve these problems, it is required to study on soLar energy as an alternative to petroleum fuels for grain drying. The purposes of this study were to find out the optimum received area and air flow rate of a flat-plate solar air collector for grain drying and to assess its effects on grain drying with a small grain bin. The results of this study are summarized as follows ; 1. The calculated optimum tilt angles of the collector in the summer and autumn drying seasons were 20 and 50 degress, respectively, in suwon area. 2. The outlet temperature of the collector was $36^\circ C$ on the daily average with the maximum of $36^\circ C$ at 12:00 o clock. Solar radiation on the collector surface was 1.04 ly( 1 langley = 1 cal/$cm^2$) per minute on the daily average and 1.30 ly per minute on the maximum at 11:00am. The thermal efficiency of the collector was 62.4 percent on the daily average, and the air flow-rate per unit receiving are was 1.03 $m^3$/min/$m^2$.4. The calculated optimum receiving area and the air flow-rate per unit cubic volume for paddy in autumn drying season was 2 $m^2$ and 2$m^3$/min , respectively. 5. not significantly difference in the collector efficiency was appeared between the rotating and fixed type of solar collector. 6. For drying of wheat with 0.6 meter of the depth in the bin, approximately 9 hours were required to reduce the moisture content from 21.6% to 13% with air follow rate of 5 $m^3$/min an initial moisture per cubic meter of wheat and with air temperature of $52^\circ C$. 7. In the drying test of rough rice with a turning operation in a grain bin approximately 21 hours were required to reduced the moisture from 21% to 14.5% with airflow rate of 2 $m^3$/min per cubic meter of rice and the air temperature of $43.5^\circ C$. 8. Over-drying at the bottom and less -drying at the top of the grain mass was resulted from the high -temperature of drying air which was obtained from the flat-plate solar collector in this test. An appropriate operation should be prepared for the uniform moisture of the grain in the bin.

  • PDF

A Preliminary Investigation of Radon Concentration for Some Agricultural Greenhouses in Jeju Island (제주지역 일부 농업 시설 내 라돈 농도 예비 조사)

  • Kang, Tae-Woo;Song, Myeong-Han;Kim, Tae-Hyoung;Chang, Byung-Uck;Kim, Young-Jae;Kim, Geun-Ho;Park, Jae-Woo
    • Korean Journal of Environmental Agriculture
    • /
    • v.31 no.1
    • /
    • pp.9-15
    • /
    • 2012
  • BACKGROUND: A preliminary investigation of the radon ($^{222}Rn$) concentration has been conducted, employing solid-state nuclear-track detectors (SSNTD) and a continuous radon monitor (CRM), for fourteen randomly selected agricultural greenhouses in Jeju Island, where the underground-air was used for air conditioning and $CO_2$ supplement. METHODS AND RESULTS: The SSNTD was used to measure the average radon concentration for three months and the CRM was used for an instantaneous measurement. In order to obtain the radon concentration of a greenhouse, the SSNTDs were placed at a number of evenly distributed points inside the greenhouse and the mean of the measured values was taken. In addition, in order to assess the radon concentration of the underground-air itself, measurement was also made at the borehole of the underground-air in each agricultural facility, employing both the SSNTD and CRM. It is found that the radon concentration of the greenhouses ranges higher than those not using the underground-air and the average of Korean dwellings. While the radon concentration of most agricultural facilities is still lower than the reference level (1,000 Bq/$m^3$) recommended by the International Radiation Protection Committee (ICRP), three facilities at one site show higher concentrations than the reference level. The three-month-averaged radon concentration and the instantaneous radon concentration of the underground-air itself ranges 1,228- 5,259 and 3,322-17,900 Bq/$m^3$, respectively, and regional variation is more significant. CONCLUSION: From this results, radon concentration of the underground-air is assumed that it is associated with the geological characteristics and the boring depth of the region located of their.

Effects on Patient Exposure Dose and Image Quality by Increasing Focal Film Distance in Abdominal Radiography (복부 일반촬영시 초점-필름간거리 변화가 피폭선량 및 화질에 미치는 영향)

  • Kim, You-Hyun;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.21 no.1
    • /
    • pp.52-58
    • /
    • 1998
  • We can and must improve the diagnostic images using available knowledge and technology. At the same time we must strive to reduce the patient's integral and entrance radiation dose. Reducing the integral dose to the patient during the radiologic procedure is a primary concern of the patient, especially the pediatric patient, the radiologist and the technologist. A 100cm focal film distance generally is used for most over-table radiography. The early x-ray tubes and screen film combinations required long exposures, which often resulted in motion artifacts. But nowaday, we have the generators and x-ray tubes that can deliver the energy necessary in a very short time and the receptors that can record the information just as rapidly. And, we performed this studies to evaluate the patient exposure dose and the image quality by increasing focal film distance in diagnostic radiography. There are many factors which affected to exposure factor, but we studied to verify of FFD increase, only. Effect of increasing the focal film distance to a 140 cm distance was tested as follows; 1. The focal film distances were set at 100, 120, and 140cm. 2. A 18cm acryl(tissue equivalent) phantom was placed on the table top. 3. An Capintec 192 electrometer with PM 05 ion chamber was placed at the entrance surface of the phantom, and exposure were made at each focal film distances. 4. The procedure was repeated in the same manner as above except the ion chamber was placed beneath the phantom at the film plane. 5. Exit exposure were normalize to 8mR for each portions of the experiment. Based on the success of the empirical measurements, a detailed mathematical analysis of the dose reduction was performed using the percent depth dose data. The results of this study can be summerized as followings ; 1) Increasing FFD from 100 cm to 140 cm, we would create a situation that would have a significant effect on the overall quality of radiograph and achive the 17.42% reduction of entrance dose and the 18.95% reduction of integral dose that the patient receives. 2) Thickness of Al step wedge for equal film density increased with the long distance. 3) Increasing FFD, Magnification of image was lowered. 4) Resolution of image also increased with the FFD. As the results described above, we strongly recommend using the long FFD to provide better information for our patients and profession in abdomen radiographic studies.

  • PDF

Modeling of Dual Head Gantry Radiotherapy System with Monte Carlo Simulation (듀얼 헤드 갠트리 방사선치료 시스템 설계를 위한 몬테칼로 시뮬레이션 연구)

  • Park, Seungwoo
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.627-632
    • /
    • 2017
  • In order to design a dual-head gantry radiotherapy system, the single head of LINAC was modeled using GATE as a preliminary study. The LINAC head was designed with VARIAN manufacturer's information. 6 MV photons were generated from the head and the photons w irradiated to a water phantom for beam evaluation. GATE simulation was segmented by two stages, the one was to generate X-ray spectrum and the other one was for irradiation X-ray to the water phantom. The quantitative results were described in Percentage depth dose and beam profile. Two field size conditions were employed as $5{\times}5$ and $10{\times}10cm^2$. After beam quality was verified, dual heads gantry radiotherapy system were simulated and they was compared to the single head of LINAC system in terms of dose deposition with in the phantom. The simulated LINAC head showed acceptable beam quality result for radiotherapy. The efficiency was calculated that deposited dose from dual heads was divided by the dose from single head. At all conditions, dual heads showed higher treatment efficiency. Efficiency was increased about 40 to 60%. Form the result, The dual head gantry system of new LINAC system will contribute to the practical radiotherapy of tumor and to reduce treatment time.