• Title/Summary/Keyword: depth calibration

Search Result 236, Processing Time 0.023 seconds

Measurement of soft tissue thickness on posterior palatal area by using computerized tomography in Korean population (전산화단층촬영법을 통한 한국인의 구개 저작 점막 두께에 대한 연구)

  • Song, Ji-Eun;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung;Kim, Chong-Kwan;Chai, Jung-Kiu
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.1
    • /
    • pp.103-113
    • /
    • 2007
  • The purpose of this study was to measure the thickness of masticatory mucosa in the hard palate as a donor site for mucogingival surgery by using computerized tomography(CT), Thickness measurements were performed in 84 adult patients who took CT on maxilla for implant surgery and 24 standard measurement points were defined in the hard palate according to the gingival margin and mid palatal suture. Radiographic measurements were utilized after calibration for standardization. Data were analyzed to determine the differences in mucosal thickness by gender, age, tooth positions and depth of palatal vault. The results of this study were as follows: 1. Mean thickness of palatal masticatory mucosa was $3.93{\pm}0.6mm$ and females had significantly thinner mean masticatory mucosa($3.76{\pm}0.56mm$) than males($4.04{\pm}0.6mm$)(p<0.05). 2. The thickness of palatal masticatory mucosa increased by aging. 3. Depending on position, masticatory mucosa thickness increased from canine to premeolar, but decreased at the first molar, and increased again in the second molar region(p<0.0001). 4. No significant difference in mean thickness of palatal masticatory mucosa were indentified between low palatal vault group and high palatal vault group(p>0.05). The results suggest that canine and premolar area appears to be the most appropriate donor site for soft tissue grafting procedure. The measurement of the thickness of palatal masticatory mucosa by using computerized tomography can offer useful information clinically but further studies in as-sessing the validity and reliability of the method using computerized tomography is needed.

Discussion of Soil Respiration for Understanding Ecosystem Carbon Cycle in Korea (생태계 탄소순환 이해를 위한 국내 토양호흡 연구의 고찰)

  • Lee, Jae-Ho;Yi, Jun-Seok;Chun, Young-Moon;Chae, Nam-Yi;Lee, Jae-Seok
    • Korean Journal of Ecology and Environment
    • /
    • v.46 no.2
    • /
    • pp.310-318
    • /
    • 2013
  • In territorial ecosystem, soil has stored considerable amount of carbon, and it is vulnerable to weakness release much of the carbon to atmosphere. In this study, we have been effort realization and discussion to the error between inter-instruments and measurement methods, time and special variations, gap filling and separation from each source included in soil respiration, used to collect soil respiration data in various ecosystems in Korea. In conclusion, it have to collect calibration data throughout comparison test between methods and instruments because accumulated data from past and accumulating data in present did not calibrated. In predicting change of soil carbon dynamic using the model method, it needs important data such as longterm and short-term data, artificial handling data of major factor, data from various ecosystem, soil texture, soil depth etc. In company with, we should collect highly qualified data through deep consideration of present problems.

Use of a Temperature as a Tracer to Study Stream-groundwater Exchange in the Hyporheic Zone (열추적자를 이용한 지하수-하천수 혼합대 연구)

  • Kim, Kue-Young;Chon, Chul-Min;Kim, Tae-Hee;Oh, Jun-Ho;Jeoung, Jae-Hoon;Park, Seung-Ki
    • Economic and Environmental Geology
    • /
    • v.39 no.5 s.180
    • /
    • pp.525-535
    • /
    • 2006
  • A study on stream-groundwater exchange was performed using head and temperature data of stream water, streambed, and groundwater. Groundwater level and temperature were obtained from multi-depth monitoring wells in small-scale watershed. During the summer and winter season, time series of temperature data at streambed and groundwater were monitored for six months. In the winter time, we measured the temperature gradient between stream water and streambed. The observed data showed three typical types of temperature characteristics. First, the temperature of streambed was lower than that of stream water; second, the temperature of streambed and stream water was similar; and the last, the temperature of streambed was higher than that of stream water. The interconnections between the stream and the streambed were not homogeneously distributed due to weakly developed sediments and heterogeneous bedrock exposed as bed of the stream. The temperature data may be used in formal solutions of the inverse problems to estimate groundwater flow and hydraulic conductivity.

The Effect of the CT Number for Each CT on Dose Calculation (CT 기종에 따른 CT 수의 변화가 선량계산에 미치는 영향)

  • Cho Kwang Hwan;Lee Suk;Cho Sam Ju;Lim Sangwook;Huh Hyun Do;Min Chul Kee;Cho Byung-Chul;Kim Yong Ho;Choi Doo Ho;Kim Eun Seog;Kwon Soo Il
    • Progress in Medical Physics
    • /
    • v.16 no.4
    • /
    • pp.161-165
    • /
    • 2005
  • The CT number corresponds to electron density and its influence on dose calculation was studied. Five kinds of CT scanners were used to obtain Images of electron density calibration phantom (Gammex RMI 467), Then the differences between CT numbers for each scanners were ${\pm}2\%$ In homogeneous medium and $9.5\%$ in high density medium. In order to Investigate the influence of CT number to dose calculation, patients' thoracic CT images were analyzed. The maximum dose difference was $0.48\%$ for each organ. It acquired the phantom Images inserted high density material in the water phantom. Comparing the doses calculated with CT Images from each CT scanner, the maximum dose difference was $2.1\%$ in 20 cm in depth. The exact density to CT number conversion according to CT scanner is required to minimize the uncertainty of dose depends on CT number Especially the each hospital with various CT scanners has to discriminate CT numbers for each CT scanner. Moreover a periodic quality assurance is required for reproducibility of CT number.

  • PDF

Patient-Specific Quality Assurance in a Multileaf Collimator-Based CyberKnife System Using the Planar Ion Chamber Array

  • Yoon, Jeongmin;Lee, Eungman;Park, Kwangwoo;Kim, Jin Sung;Kim, Yong Bae;Lee, Ho
    • Progress in Medical Physics
    • /
    • v.29 no.2
    • /
    • pp.59-65
    • /
    • 2018
  • This paper describes the clinical use of the dose verification of multileaf collimator (MLC)-based CyberKnife plans by combining the Octavius 1000SRS detector and water-equivalent RW3 slab phantom. The slab phantom consists of 14 plates, each with a thickness of 10 mm. One plate was modified to support tracking by inserting 14 custom-made fiducials on surface holes positioned at the outer region of $10{\times}10cm^2$. The fiducial-inserted plate was placed on the 1000SRS detector and three plates were additionally stacked up to build the reference depth. Below the detector, 10 plates were placed to avoid longer delivery times caused by proximity detection program alerts. The cross-calibration factor prior to phantom delivery was obtained by performing with 200 monitor units (MU) on the field size of $95{\times}92.5mm^2$. After irradiation, the measured dose distribution of the coronal plane was compared with the dose distribution calculated by the MultiPlan treatment planning system. The results were assessed by comparing the absolute dose at the center point of 1000SRS and the 3-D Gamma (${\gamma}$) index using 220 patient-specific quality assurance (QA). The discrepancy between measured and calculated doses at the center point of 1000SRS detector ranged from -3.9% to 8.2%. In the dosimetric comparison using 3-D ${\gamma}$-function (3%/3 mm criteria), the mean passing rates with ${\gamma}$-parameter ${\leq}1$ were $97.4%{\pm}2.4%$. The combination of the 1000SRS detector and RW3 slab phantom can be utilized for dosimetry validation of patient-specific QA in the CyberKnife MLC system, which made it possible to measure absolute dose distributions regardless of tracking mode.

A Prototype Architecture of an Interactive Service System for Digital Hologram Videos (디지털 홀로그램 비디오를 위한 인터랙티브 서비스 시스템의 프로토타입 설계)

  • Seo, Young-Ho;Lee, Yoon-Hyuk;Yoo, Ji-Sang;Kim, Man-Bae;Choi, Hyun-Jun;Kim, Dong-Wook
    • Journal of Broadcast Engineering
    • /
    • v.17 no.4
    • /
    • pp.695-706
    • /
    • 2012
  • The purpose of this paper is to propose a service system for a digital hologram video, which has not been published yet. This system assumes the existing service frame for 2-dimensional or 3-dimensional image/video, which includes data acquisition, processing, transmission, reception, and reconstruction. This system also includes the function to service the digital hologram at the viewer's view point by tracking the viewer's face. For this function, the image information at the virtual view point corresponding to the viewer's view point is generated to get the corresponding hologram. Here in this paper, only a prototype that includes major functions of it is implemented, which includes camera system for data acquisition, camera calibration and image rectification, depth/intensity image enhancement, intermediate view generation, digital hologram generation, and holographic image reconstruction by both simulation and optical apparatus. The proposed prototype system was implemented and the result showed that it takes about 352ms to generate one frame of digital hologram and reconstruct the image by simulation, or 183ms to reconstruct image by optical apparatus instead of simulation.

Study for Conductive and Non-conductive Multi-layers Depth Profiling Analysis of Radio Frequency Gas-jet Boosted Glow Discharge Spectrometry (Modified Gas-jet Boosted Radio-frequency Glow Discharge 셀의 개발 및 최적화에 관한 연구)

  • Cho, Won Bo;Borden, Stuart;Jeong, Jong Pil;Kang, Won Kyu;Kim, Kyu Whan;Kim, Hyo Jin
    • Analytical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.108-114
    • /
    • 2002
  • The new system using a glow discharge atomic emission spectrometer for the direct analysis of solid samples has been developed and characterized. The system was consisted of new glow discharge cell improved previous gas-jet boosted nozzle and radio-frequency power supply. In the case of previous type glow discharge chamber, it had been fitted trace analysis of low alloy steel with low discharge power, because it was to decrease redeposition and increase sample weight loss. But it had a problem that plasma becomes unstale due to increased sample weight loss and redeposition resulting from the high discharge power. Because of being problem of previous glow discharge, it is impossible to analyze using high power. The modified gas-jet boosted glow discharge to solve this problem would improve to be less sample loss rate of modified nozzle than sample loss rate of previous nozzle on the equal discharge condition, and improve to increase stability of plasma. The effect of discharge parameters such as discharge pressure, gas flow rate and power on the sample loss rate, emission intensity has been studied to find optimum discharge conditions. The calibration curves of Fe were obtained with 3 low-alloy samples.

Analysis of Water Quality Impact for Water Intake in Jinyang Reservoir Using CE-QUAL-W2 (CE-QUAL-W2를 이용한 진양호 취수량 변화에 따른 수질영향 분석)

  • Tak, Yong Hun;Kim, Young Do;Chong, Sun-a;Chung, Se Woong
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.10
    • /
    • pp.857-868
    • /
    • 2015
  • Hydraulic and water quality models with high reliability are necessary for the efficient management of water quality in the reservoir. The model capacity can be demonstrated by the application for the various hydrological conditions. CE-QUAL-W2 model is laterally averaged two-dimensional hydraulic and water quality model. The W2 model, which is suitable for the narrow reservoir like the Jinyang reservoir as compared with the depth and length of waterbody, has been frequently used by many researchers. Namgang watershed is expected to increase the water demand. In this study, the W2 model is validated under two different hydrological conditions; wet year (2011) and normal year (2009). Using hydrological and water quality condition for calibration, 2011, the effect of water intake increase was simulated. The simulation results showed that the increase of water intake led to increase the concentrations in total nitrogen, total phosphorus and Chlorophyll-${\alpha}$ concentration. Especially the concentration increase was appeared during the dry season in each of up to 62.53% (Total nitrogen), 39.07% (Total phosphorus) and 232.19% (Chlorophyll-${\alpha}$). The changes of chlorophyll-${\alpha}$ is similar to those of total phosphorus concentration.

Parameterization and Application of Regional Hydro-Ecologic Simulation System (RHESSys) for Integrating the Eco-hydrological Processes in the Gwangneung Headwater Catchment (광릉 원두부 유역 생태수문과정의 통합을 위한 지역 생태수문 모사 시스템(RHESSys)의 모수화와 적용)

  • Kim, Eun-Sook;Kang, Sin-Kyu;Lee, Bo-Ra;Kim, Kyong-Ha;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.9 no.2
    • /
    • pp.121-131
    • /
    • 2007
  • Despite the close linkage in changes between the ecological and hydrological processes in forest ecosystems, an integrative approach has not been incorporated successfully. In this study, based on the vegetation and hydrologic data of the Gwangneung headwater catchment with the Geographic Information System, we attempted such an integrated approach by employing the Regional Hydro-Ecologic Simulation System (RHESSys). To accomplish this, we have (1) constructed the input data for RHESSys, (2) developed an integrated calibration system that enables to consider both ecological and hydrological processes simultaneously, and (3) performed sensitivity analysis to estimate the optimum parameters. Our sensitivity analyses on six soil parameters that affect streamflow patterns and peak flow show that the decay parameter of horizontal saturated hydraulic conductivity $(s_1)$ and porosity decay by depth (PD) had the highest sensitivity. The optimization of these two parameters to estimate the optimum streamflow variation resulted in a prediction accuracy of 0.75 in terms of Nash-Sutcliffe efficiency (NSec). These results provide an important basis for future evaluation and mapping of the watershed-scale soil moisture and evapotranspiration in forest ecosystems of Korea.

Parameter Sensitivity Analysis of VfloTM Model In Jungnang basin (중랑천 유역에서의 VfloTM 모형의 매개변수 민감도 분석)

  • Kim, Byung Sik;Kim, Bo Kyung;Kim, Hung Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.6B
    • /
    • pp.503-512
    • /
    • 2009
  • Watershed models, which are a tool for water cycle mechanism, are classified as the distributed model and the lumped model. Currently, the distributed models have been more widely used than lumped model for many researches and applications. The lumped model estimates the parameters in the conceptual and empirical sense, on the other hand, in the case of distributed model the first-guess value is estimated from the grid-based watershed characteristics and rainfall data. Therefore, the distributed model needs more detailed parameter adjustment in its calibration and also one should precisely understand the model parameters' characteristics and sensitivity. This study uses Jungnang basin as a study area and $Vflo^{TM}$ model, which is a physics-based distributed hydrologic model, is used to analyze its parameters' sensitivity. To begin with, 100 years frequency-design rainfall is derived from Huff's method for rainfall duration of 6 hours, then the discharge is simulated using the calibrated parameters of $Vflo^{TM}$ model. As a result, hydraulic conductivity and overland's roughness have an effect on runoff depth and peak discharge, respectively, while channel's roughness have influence on travel time and peak discharge.