• 제목/요약/키워드: denture cleansers

검색결과 14건 처리시간 0.023초

Evaluation of antibacterial activity against Candida albicans according to the dosage of various denture cleansers

  • Bae, Cha-Hwan;Lim, Yun-Kyong;Kook, Joong-Ki;Son, Mee-Kyoung;Heo, Yu-Ri
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권2호
    • /
    • pp.100-106
    • /
    • 2021
  • PURPOSE. The purpose of this study is to compare the antibacterial activity of currently purchasable denture cleansers against Candida albicans. Materials and methods: This study used tablet-type denture cleansers, PolidentⓇ, CoolingdentⓇ and FittydentⓇ, along with liquid denture cleansers, HexamedineⓇ, ListerineⓇ and Apple vinegarⓇ. The antibacterial activities of denture cleansers were evaluated based on the number of C. albicans and concentrations of the denture cleansers. Results. In the 0.5 × 106 cfu/㎖ culture medium, the C. albicans' death rate of PolidentⓇ was significantly lower than those of FittydentⓇ, HexamedineⓇ, ListerineⓇ, and Apple vinegarⓇ(P<.05). In the 0.5 × 107 cfu/, the C. albicans' death rates of PolidentⓇ and CoolingdentⓇ were significantly lower than those of FittydentⓇ, HexamedineⓇ, ListerineⓇ and Apple vinegarⓇ(P<.05). The C. albicans' death rates of PolidentⓇ and CoolingdentⓇ were significantly decreased at 0.02 g and 0.01 g. The C. albicans' death rate of FittydentⓇ was significantly decreased at 0.005 g (P<.05). The C. albicans' death rate of HexamedineⓇ was significantly decreased at 1/16 dilution. The C. albicans' death rate of ListerineⓇ was decreased at 1/8 dilution, and the antibacterial activity of Apple vinegarⓇ was decreased at 1/4 dilution (P<.05). Conclusion. As the number of C. albicans increased, the antibacterial activities of the denture cleansers decrease. In the tablet-type denture cleanser, all denture cleansers showed 100% C. albicans' death rate when used at a dose of 1 tablet. One denture cleanser showed the same antibacterial effect with only 1/3 of a tablet. In the liquid type denture cleanser, the level of dilution required was different for each denture cleanser.

의치 세정제가 의치상용 레진과 이장용 레진의 결합강도에 미치는 영향 (The effect of denture cleansers on the bond strength of reline resin to denture base resin)

  • 최에스더;한민수;권은자
    • 대한치과기공학회지
    • /
    • 제40권4호
    • /
    • pp.225-230
    • /
    • 2018
  • Purpose: The purpose of this study was to evaluate the effect of denture cleansers on the flexural bond strength of heat curing denture base resin and reliners. Methods: The denture base resin was bonded to the reliners(vertex self curing, kooliner, rebase II) to make the specimen. The specimens were immersed in denture cleansers(Polident, Cleadent) and evaluated after 1week, 3week, 5weeks. After denture reliners were injected, flexural bond strength was measured. Results: The bond strength of denture base resin and vertex self curing resin as reliner was significantly decreased at 5 weeks in cleadent and polident(p<0.05). The bond strength of kooliner and rebase II was significantly decreased at 5 weeks in denture cleaners(p<0.05). Kooliner was significantly decreased at 3 and 5 weeks in polident and rebase II was significantly decreased at 3 and 5 weeks in all denture cleansers(p<0.05). Conclusion : The flexural strength between the denture base resin and the reliners decreased significantly as the treatment time increased.

의치 세정제가 탄성 의치상 이장재에 미치는 효과에 관한 연구 (THE EFFECT OF DENTURE CLEANSERS ON SOFT LINING MATERIALS)

  • 장복숙;김창회;김영수
    • 대한치과보철학회지
    • /
    • 제31권2호
    • /
    • pp.219-235
    • /
    • 1993
  • To determine the compatibilities of soft liming materials with denture cleansers by measuring the flexibility and elasticity and investigating the surface changes, 4 self-curing acrylic resin soft lining materials and 1 heat-curing silicone soft lining material were evaluated. 3mm thick x 20mm diameter discs of soft lining materials were individually bonded to a hard acrylic resin base as per manufacturers’instructions. Using an Instron universal testing machine, a static stress of $2kg/cm^2$ was applied for 30secs., the strain in compression was measured, giving an indication of the material’s flexibility. Elastic recovery was measured at 10secs. After removal of stress. Surface changes were investigated with Stereomicroscope. Then the specimens were immersed in 4alkaline peroxide denture cleansers and water as control group, tests were carried out at 1 day, 2 days, 7 days, 14 days and 30 days. The results were as follows : 1. Alkaline peroxide denture cleansers caused considerable porosity on the surface of selfcuring acrylic resin soft lining materials, and the most affected by the cleansers were Viscogel, Coe-Soft, Coe-Comfort, Lynal, in that order. 2. There was significant difference in flexibility between each soft lining material except for Coe-Comfort and Visco-gel, and every soft lining material was significant difference in elasticity. Especially Molloplast-B and Lynal were less flexible and more elastic than other soft lining materials(p<0.05). 3. The denture cleansers increased the flexibility and elasticity of the soft lining materials compared with control group(p<0.05), and Denalan, Polident, Kleenite, Efferdent affected the soft lining materials in that order. 4. There was significant difference in flexibility between each denture cleanser except for Denalan and Polident(p<0.05). Though Denalan and Polident, Denalan and Kleenite did not show significant difference in elasticity, other denture cleansers showed significant difference among each other(p<0.05). 5. Clinically Coe-Comfort, Coe-Soft and Visco-gel were incompatible with alkaline peroxide denture cleansers, and Lynal would be used within only 2 weeks. But Molloplast-B was compatible with alkaline peroxide denture cleansers.

  • PDF

의치 세정제가 의치상 레진과 이장용 레진의 결합강도와 표면경도에 미치는 영향 (THE EFFECT OF DENTURE CLEANSERS ON THE BOND STRENGTH AND THE SURFACE HARDNESS OF RELINE RESIN TO DENTURE BASE RESIN)

  • 김계순;정회열;김유리;조혜원
    • 대한치과보철학회지
    • /
    • 제41권4호
    • /
    • pp.493-502
    • /
    • 2003
  • Statement of problem : Removable partial denture and complete denture often require denture base relines to improve the fittness against tissue-bearing mucosa because of the gradual change in edentulous ridge contour and resorption of underlyng bony structure. Self-curing hard reline resins offers the immediate and relatively inexpensive means to be recondition the surface of denture base directly However weak bond between denture base resin and reline material can harbor bacteria, promote staining, or result in complete separation of the two materials. Purpose : The purpose of this study was to evaluate the effect of denture cleansers on bond strength and surface hardness of reline resin to denture base resin Denture base resin beams($60.0{\times}15.0{\times}3.0mm$) were made with Lucitone 199. Material and methods : 10mm section was removed from the center of each specimen. The samples were replaced in the molds and the space of l0mm sections were packed with Tokuso Rebase reline material. The specimens were immersed in denture cleansers (Polident, Cleadent) and were evaluated after 1 week, 2 weeks, and 4 weeks. The bond strength and surface hardness of self-curing hard reline materials to heat-curing denture base resin were measured using an UTM (universal testing machine). Results and conclusion : 1) There was no significant difference of usage, kind, and denture cleaner by application time on the bonding strength of self-curing hard reline resin to denture base resin. 2) There was no significant difference of usage, kind, and denture cleaner by application time on the surface hardness, but the surface hardness showed decreasing tendency, as the time of immersion was extended. 3) The failure modes of the specimens was initially adhesive failure and finally cohesive failure of self-curing hard reline resin.

Effect of denture cleansers on Candida albicans biofilm formation over resilient liners

  • Huh, Jung-Bo;Lim, Younghun;Youn, Hye-In;Chang, Brian Myung;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권2호
    • /
    • pp.109-114
    • /
    • 2014
  • PURPOSE. The purpose of this study was to analyze the effect of denture cleansers on Candida albicans biofilm formation over resilient liners and to evaluate compatibility between resilient liners and denture cleansers. MATERIALS AND METHODS. Acrylic resin (Lucitone 199$^{(R)}$) and 3 resilient liners (COE-SOFT$^{TM}$, GC RELINE$^{TM}$ and SOFRELINER TOUGH TOUGH$^{(R)}$) were incubated in denture cleansers (Polident$^{(R)}$ and Cleadent$^{(R)}$) for 8 hours a day and in unstimulated saliva for 16 hours a day (n=25/gp) for 60 days. Two-way and three-way repeated measures ANOVA were performed to compare the surface roughness (Ra), pH and C. albicans binding level by radioisotope (${\alpha}$=0.05). The statistical significance of the relation between Ra and adhesion was evaluated by correlation analysis. RESULTS. The degree of Ra was significantly decreased in the following order: COE-SOFT$^{TM}$, acrylic resin, GC RELINE$^{TM}$ and SOFRELINER TOUGH$^{(R)}$. The immersion in denture cleansers significantly increased Ra of resilient liners, except for SOFRELINER TOUGH$^{(R)}$ in Cleadent$^{(R)}$. No significant differences in pH curves were observed among groups immersed in distilled water and denture cleansers. The binding levels of C. albicans were significantly decreased in the following order: COE-SOFT$^{TM}$, GC RELINE$^{TM}$, SOFRELINER TOUGH$^{(R)}$, and acrylic resin. The immersion in Cleadent$^{(R)}$ seemed to decrease C. albicans binding level on GC RELINE$^{TM}$ and SOFRELINER TOUGH$^{(R)}$. CONCLUSION. Based on the C. albicans binding levels results, it is not recommended to immerse COE-SOFT$^{TM}$ in denture cleansers, and GC RELINE$^{TM}$ and SOFRELINER TOUGH$^{(R)}$ should be immersed in Cleadent$^{(R)}$.

의치세정제와 소독제가 의치상 레진의 색조, 표면경도, 표면조도에 미치는 영향에 대한 연구 (THE EFFECTS OF DENTURE CLEANSERS AND DISINFECTANTS ON THE COLOR, SURFACE HARDNESS, SURFACE ROUGHNESS OF DENTURE BASE RESINS)

  • 양희진;장복숙;정동준;허성주;한동후;심준성;장명우
    • 대한치과보철학회지
    • /
    • 제39권1호
    • /
    • pp.105-113
    • /
    • 2001
  • The purpose of this study is to compare effects of denture cleansers and disinfectants on the color. surface hardness, and surface roughness of reinforced acrylic resin using polyhedral oligosilsesquioxane molecules(POSS resin) to those of common resins. According to manufacturer's instructions, 45 specimens were made from three denture resins(Luciton 199, Paladent 20, POSS resin), and polished. Five denture cleansers(distilled water, glutaraldehyde, alkaline hypochlorites, chlorhexidine, alkaline peroxides) in combination with three denture resins were evaluated before and after immersion for 7 days. Color data in $L^*a^*b^*$ system were measured with a colorimeter. Surface hardness data were measured with a microhardness tester. Surface roughness data were measured with a 3-dimensional surface analyzer. Data were analyzed with two-way ANOVA, one-way ANOVA, and t-test. The results were as follows : 1. All resins(Luciton 199, Paladent 20, POSS resin) showed significant differences in color after immersion in hypochlorites(p<0.05). 2. POSS resin showed significant differences in color compared with Paladent 20 in all denture cleansers, but no statistically significant differences with Luciton 199(p<0.05). 3. Luciton 199 showed significant differences of surface hardness in chlorhexidine, Paladent 20 showed significant differences in glutaraldehyde and chlorhexidine. POSS resin showed a little change of surface in all denture cleanser, but no statistically significant differences(p<0.05). 4. Luciton 199 and Paladent 20 showed significant differences of surface roughness in hypochlorites and glutaraldehyde, and POSS resin showed no statistically significant differences in all denture cleansers(p<0.05).

  • PDF

Effect of denture cleansers on surface hardness of resilient denture liners at various time intervals- an in vitro study

  • Pahuja, Rasleen Kaur;Garg, Sandeep;Bansal, Sanjay;Dang, Rajat Harvinder
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권3호
    • /
    • pp.270-277
    • /
    • 2013
  • PURPOSE. This study was aimed to determine the effect of two chemically distinct denture cleansers and water on the surface hardness of acrylic and silicone based soft denture liners at various time intervals. MATERIALS AND METHODS. Two commonly used commercial resilient liner material were selected based on their chemical composition (silicone- and acrylic-based soft liners) for this investigation. 120 cylindrical specimens were made of $15mm{\times}10mm$ dimensions (according to ASTM: D-2240-64T) in a custom made metal mold. All specimens were stored in artificial saliva throughout the study. Forty specimens were cleansed daily in 0.5% sodium hypochlorite solution; forty were cleansed in sodium perborate and remaining forty specimens were daily rinsed in water. Testing was done at 1 week, 1 month, 3 months and 6 months for surface hardness using a Shore A Durometer. A mean of 3 reading for each sample was subjected to one-way ANOVA, Post Hoc test and pair-t test for statistical analysis. P values of less than 0.05 were taken as statistically significant. RESULTS. Surface hardness of all the samples was significantly higher after a period of 6 months irrespective of the cleansing treatment. Minor changes were observed between control, sodium hypochlorite and sodium perborate groups with time. Greater change was observed in surface hardness of acrylic-based soft denture liners as compared to silicone-based soft liners for all groups, as time progressed. CONCLUSION. Silicone-based soft denture liners performed significantly better in all cleansing treatments than acrylic-based soft denture liners.

Effect of different denture cleansers on surface roughness and microhardness of artificial denture teeth

  • Yuzugullu, Bulem;Acar, Ozlem;Cetinsahin, Cem;Celik, Cigdem
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권5호
    • /
    • pp.333-338
    • /
    • 2016
  • PURPOSE. The aim of this study was to compare the effects of different denture cleansers on the surface roughness and microhardness of various types of posterior denture teeth. MATERIALS AND METHODS. 168 artificial tooth specimens were divided into the following four subgroups (n=42): SR Orthotyp PE (polymethylmethacrylate); SR Orthosit PE (Isosit); SR Postaris DCL (double cross-linked); and SR Phonares II (nanohybrid composite). The specimens were further divided according to the type of the denture cleanser (Corega Tabs (sodium perborate), sodium hypochlorite (NaOCl), and distilled water (control) (n=14)) and immersed in the cleanser to simulate a 180-day immersion period, after which the surface roughness and microhardness were tested. The data were analyzed using the Kruskal-Wallis test, Conover's nonparametric multiple comparison test, and Spearman's rank correlation analysis (P<.05). RESULTS. A comparison among the denture cleanser groups showed that NaOCl caused significantly higher roughness values on SR Orthotyp PE specimens when compared with the other artificial teeth (P<.001). Furthermore, Corega Tabs resulted in higher microhardness values in SR Orthotyp PE specimens than distilled water and NaOCl (P<.005). The microhardness values decreased significantly from distilled water, NaOCl, to Corega Tabs for SR Orthosit PE specimens (P<.001). SR Postaris DLC specimens showed increased microhardness when immersed in distilled water or NaOCl when compared with immersion in Corega Tabs (P<.003). No correlation was found between surface roughness and microhardness (r=0.104, P=.178). CONCLUSION. NaOCl and Corega Tabs affected the surface roughness and microhardness of all artificial denture teeth except for the new generation nanohybrid composite teeth.

일부 세치제와 주방세제 사용에 의한 의치상 레진의 표면변화 (Surface changes of denture base resin according to two toothpastes and a kitchen detergent)

  • 강재경;김수화;유은미;최혜숙;최유리;김광만
    • 한국치위생학회지
    • /
    • 제12권3호
    • /
    • pp.611-620
    • /
    • 2012
  • Objectives : This study evaluated the changes in surface roughness of denture base resin according to the types of denture cleansers. Methods : A denture base resin(Vertex RS, Dentimax, Netherland) was used. Two toothpaste(Antiplaque, Bukwang, Korea; 2080, Aekyung, Korea) and a kitchen detergent(Trio, Aekyung, Korea) were used as a denture cleanser. The specimens were put on the V8 crossbrushing machine(Sabri enterprises, Downers grove, IL, USA) to reproduce toothbrushing and the toothbrushes were flat, round end and soft type. The surfaces of denture base resin specimens were observed by profilometer(SJ-400, MITUTOYO, Japan) and SEM(S-3000N, Hitachi Co., Ibaraki, Japan). Results : 1. According to the result of measuring surface roughness, there was statistically significant difference in Ra, Rq, and Rz(p<0.05). 2. As for Ra, Rq and Rz, Antiplaque toothpaste showed the highest roughness, and there was significant difference from other groups(p<0.01). 2080 toothpaste, Trio, and distilled water were classified as the same group. 3. According to the result of observation with the SEM, the surfaces of the Antiplaque toothpaste group after toothbrushing showed the greatest roughness, and the surfaces of 2080 toothpaste, Trio, and distilled water groups were rough in order. Trio and distilled water had the surfaces similar to those before toothbrushing. Conclusions : Studies to compare the efficacy of denture management methods and examine the effects of denture cleansers on denture materials will be helpful for dental hygienists and dentists providing patients with proper information and education. And it will be also useful for denture users' oral health.

재가복지 노인의치 세정제의 음식물 세정효과 비교연구 (A comparative study on denture cleansers for food stain removal on the denture of elders in domiciliary care)

  • 이남순
    • 한국산학기술학회논문지
    • /
    • 제19권1호
    • /
    • pp.331-336
    • /
    • 2018
  • 고령화 시대에 건강을 유지하고 증진시키기 위한 가장 중요한 필수 요건 중 하나는 바로 구강건강이다. 특히 재가노인들의 구강건강 개선은 그들의 삶의 질에 직접적인 영향을 미치며, 의치의 위생적인 관리와 깊은 연관관계가 있는 것으로 알려져 있다. 하지만 노인의치의 청결한 관리의 중요성이 강조되고 있음에도 불구하고 시장에 출시된 의치관련 세정제들의 정량적인 성능평가나 연구는 부족한 실정이다. 따라서 본 연구의 목적은 단백분해효소가 들어있는 의치세정제의 음식물 얼룩 제거성능을 평가하여, 세정제를 이용한 자가 세정방법에 대한 기본 자료와 재가노인들의 구강건강을 위한 효율적인 치료 개선방안을 제시하는 것이다. 세 가지 종류의 각 단백효소 의치세정제의 음식 얼룩 제거성능에 관한 정량적인 데이터를 확보하기 위하여 한국소비자원이 제시한 시험평가방법과 관련 재료의 시험평가 기준인 ISO 20795가 사용되었다. 총 18개의 시편이 강황성분을 용해한 물에 48시간 담가 변색시킨 후, 각각의 단백효소 의치세정제로 24시간 동안 세정하였다. 세정시킨 의치 시편은 분광광도계를 이용하여 변색 전 의치 시편의 색조 값과 변색 시편을 의치세정제로 세정한 후의 색조 값의 색차를 정량적으로 측정하였다. 실험 값은 one-way ANOVA with post-hoc Tukey's test를 통해 분석 되었으며, 각 실험 군들 간의 통계적으로 유의한 차이를 발견하고 C가 A와 B보다 통계적으로 유의한 얼룩제거성능이 있는 것을 확인 할 수 있었다(p<.05). 모든 실험은 2017년 7월 3일부터 7월 23일까지 총 21일간 진행되었다. 이상과 같은 결과를 통해 노인의치의 적절한 의치관리 법으로 최소한의 손상을 주는 세척방법이 권장되고, 올바른 정보를 제공할 필요가 있으며, 고령화시대에 지속적인 구강보건과 구강건강에 노인의치의 재가 세정작업에 최적화하고자 한다.