• 제목/요약/키워드: dental composites

검색결과 173건 처리시간 0.025초

Color discrepancy of single-shade composites at different distances from the interface measured using cell phone images

  • Marcia Luciana Carregosa Santana;Gabriella de Jesus Santos Livi;Andre Luis Faria-e-Silva
    • Restorative Dentistry and Endodontics
    • /
    • 제49권1호
    • /
    • pp.7.1-7.11
    • /
    • 2024
  • Objectives: This study aimed to evaluate the impact of substrate color and interface distance on the color adjustment of 2 single-shade composites, Vittra APS Unique and Charisma Diamond One. Materials and Methods: Dual disc-shaped specimens were created using Vittra APS Unique or Charisma Diamond One as the center composite, surrounded by shaded composites (A1 or A3). Color measurements were taken with a spectrophotometer against a gray background, recording the color coordinates in the CIELAB color space. Illumination with a light-correcting device and image acquisition using a polarizing filter-equipped cell phone were performed on specimens over the same background. Image processing software was used to measure the color coordinates in the center and periphery of the inner composite and in the outer composite. The color data were then converted to CIELAB coordinates and adjusted using data from the spectrophotometer. Color differences (ΔE00) between the center/periphery of single-shade and outer composites were calculated, along with color changes in single-shade composites caused by different outer composites. Color differences for the inner composites surrounded by A1 and A3 were also calculated. Data were analyzed using repeated-measures analysis of variance (α = 0.05). Results: The results showed that color discrepancies were lowest near the interface and when the outer composite was whiter (A1). Additionally, Charisma Diamond One exhibited better color adjustment ability than Vittra APS Unique. Conclusions: Color discrepancies between the investigated single-shade composites diminished towards the interface with the surrounding composite, particularly when the latter exhibited a lighter shade.

Bulk-fill 복합레진, 믿고 사용해도 될까?

  • 고결;박정원
    • 대한치과의사협회지
    • /
    • 제57권3호
    • /
    • pp.162-168
    • /
    • 2019
  • Composite resin restorations in posterior teeth are increasing due to the aesthetic needs of patients and the development of materials. This trend will accelerate in line with domestic insurance policies. However, resin composites generate stresses due to their contraction during the polymerization process. To reduce the polymerization shrinkage stress of resin composites, incremental layering technique has been recommended for decades. This technique reduces stress at the cavity wall interface and allows a more efficient light curing of the material. Bulk-fill resin composites have been designed to simplify the restorative technique because they can be placed into cavities in a single increment of 4-5mm. The simplification of the operative procedures is desirable in clinical daily practice. In this context, bulk-fill resin composites are an attractive alternative for posterior restorations. However, a clearer understanding of the clinical performance of this relatively new class of materials in comparison to conventional resin composites is required. Based on previous studies, the aim of the current review was to present the clinical criteria for the use of bulk-fill composites in direct restorations of posterior teeth.

  • PDF

Silorane-기질 치아 수복용 복합레진의 중합수축과 중합수축응력 (Polymerization Shrinkage and Stress of Silorane-based Dental Restorative Composite)

  • 이인복;박성환;권현정;구자국;최낙삼
    • Composites Research
    • /
    • 제26권3호
    • /
    • pp.182-188
    • /
    • 2013
  • 본 연구의 목적은 silorane 기질의 치아 수복용 복합레진의 중합수축과 수축응력의 동력학을 평가하고 전통적인 methacrylate 기질의 복합레진과 비교하기 위함이다. 두 종의 methacrylate 기질의 복합레진(Z250, Z350 flowable)과 silorane 기질 복합레진(P90)이 사용되었다. 아르키메데스 원리를 응용해 자체 제작한 중합수축 측정 장치를 사용하여 광중합 중 일어나는 복합레진의 체적 중합수축을 측정하였고 스트레인게이지로 중합수축응력을 측정하였다. Silorane 기질 복합레진인 P90의 중합수축과 최대 중합수축률이 가장 낮았고 methacrylate 기질 복합레진인 Z350 flowable이 가장 높았다. Methacrylate 기질의 복합레진과 비교하여 silorane 기질의 복합레진 P90이 최대 수축률에 이른 시간은 더 길었고 중합수축응력은 낮았다.

수계공정에 의한 알루미나 테이프로 제조한 세라믹 인공치관용 알루미나 유리 복합체의 기계적 물성 (Mechanical Properties of Alumina-Glass Dental Composites Prepared from Aqueous-Based Tape Casting)

  • 이명현;김대준;이득용;이정훈;김창은
    • 한국세라믹학회지
    • /
    • 제36권10호
    • /
    • pp.1123-1131
    • /
    • 1999
  • Alumina-glass composites which are considered as the material of the choice for all dental crown was prepared by aqeous-based tape casting and sintering for 2h at 1120$^{\circ}C$ followed by glass infiltration for 2h at 1100$^{\circ}C$ Biaxial strength and fracture toughness of the composites were evaluated to determine the optimum composition of the tape as a function of the amount of constituent such as alumina binder and plasticizer. The strength and the fracture toughness of the alumina tape increased with increasing the contents of alumina and binder. These observations are consistent with in fluence of the constituents on mean alumuna particle distance in tapes suggesting that high strength of the glass infiltrated alumina composites is related to toughening by crack bowing. The biaxial strength and the fracture toughness of the composite containing the optimum constituent composition were 523 MPa and 3.3 MPa$.$1/2 respectively.

  • PDF

나노 충전제 함량에 따른 복합레진의 표면 미세경도 차이 (EFFECTS OF NANOFILLER CONTENT ON THE MICROHARDNESS OF EXPERIMENTAL MICROHYBRID RESIN COMPOSITES)

  • 정영정;김영재;김정욱;이상훈;김종철;한세현;장기택
    • 대한소아치과학회지
    • /
    • 제32권1호
    • /
    • pp.7-12
    • /
    • 2005
  • 최근에 개발된 나노 충전제를 microhybrid 복합레진에 첨가할 때, 나노 충전제 함량이 중합에 미치는 영향을 조사하기 위해, 실험적으로 나노 충전제의 함량을 다르게 제작한 복합레진에서 광중합 후 미세경도를 측정, 분석하여 다음과 같은 결론을 얻었다. 1. 나노 충전제의 함량이 2%, 3%인 군은 0%, 1%인 군에 비해 중합된 면의 미세경도가 유의하게 높았으나(p<0.01), 그 차이는 크지 않았다. 2. 나노 충전제의 함량이 높을수록 레진 시편의 하면에서의 미세경도는 증가하였으며, 나노 충전제의 함량이 0%, 1%, 2%간에 0%, 1%, 3%간에 유의한 차이가 있었고(p<0.01), 2%와 3%간에는 차이가 없었다(p>0.05). 3. 레진 시편의 상면과 하면의 미세 경도 차이는 나노 충전제 함량이 높을수록 감소하였으며, 나노 충전제의 함량이 0%, 1%, 2%간에, 0%, 1%, 3%간에 유의한 차이가 있었고(p<0.01), 2%와 3%간에는 차이가 없었다(p>0.05).

  • PDF

Effect of water storage on flexural strength of silorane and methacrylate-based composite resins

  • Panahandeh, Narges;Torabzadeh, Hassan;Naderi, Hani;Sheikh-Al-Eslamian, Seyedeh Mahsa
    • Restorative Dentistry and Endodontics
    • /
    • 제42권4호
    • /
    • pp.309-315
    • /
    • 2017
  • Objectives: This study assessed the effect of water storage on the flexural strength (FS) of low shrinkage composites. Materials and Methods: A total of 165 bar-shaped specimens ($2{\times}2{\times}25mm$) were fabricated of 2 low shrinkage composites (Filtek P90 [3M ESPE], GC Kalore [GC International]) and a conventional methacrylate-based composite (Filtek Z250 [3M ESPE]). The specimens were subjected to 3-point bending test at 6 time intervals, namely: immediately after curing, at 24 hours, 1 week, 1 month, 6 months, and 1 year following storage in wet and dry conditions. The FS of the specimens were measured by applying compressive load at a crosshead speed of 1.0 mm/min. Data was analyzed using 3-way analysis of variance (ANOVA) and Tukey's test. Results: Three-way ANOVA revealed significant interactions between time, type of composite, and storage condition (p = 0.001). Tukey's multiple comparison test revealed significant reductions in FS of all composites after 6 months and 1 year of storage in distilled water compared to dry condition. Conclusions: Filtek P90 showed the highest and GC Kalore showed the lowest FS after 1 year storage in distilled water. The immediate high strength of Filtek Z250 significantly decreased at 1 year and its final value was lower than that of Filtek P90.

The effect of individualization of fiberglass posts using bulk-fill resin-based composites on cementation: an in vitro study

  • Lins, Rodrigo Barros Esteves;Cordeiro, Jairo Matozinho;Rangel, Carolina Perez;Antunes, Thiago Bessa Marconato;Martins, Luis Roberto Marcondes
    • Restorative Dentistry and Endodontics
    • /
    • 제44권4호
    • /
    • pp.37.1-37.10
    • /
    • 2019
  • Objectives: This study evaluated the bond strength of various fiberglass post cementation techniques using different resin-based composites. Materials and Methods: The roots from a total of 100 bovine incisors were randomly assigned to 5 treatment groups: G1, post + Scotchbond Multi-Purpose (SBMP) + RelyX ARC luting agent; G2, relined post (Filtek Z250) + SBMP + RelyX ARC; G3, individualized post (Filtek Z250) + SBMP; G4, individualized post (Filtek Bulk-Fill) + SBMP; G5, individualized post (Filtek Bulk-Fill Flow) + SBMP. The samples were subjected to the push-out (n = 10) and pull-out (n = 10) bond strength tests. Data from the push-out bond strength test were analyzed using 2-way analysis of variance (ANOVA) with the Bonferroni post hoc test, and data from the pull-out bond strength test were analyzed using 1-way ANOVA. Results: The data for push-out bond strength presented higher values for G2 and G5, mainly in the cervical and middle thirds, and the data from the apical third showed a lower mean push-out bond strength in all groups. No significant difference was noted for pull-out bond strength among all groups. The most frequent failure modes observed were adhesive failure between dentine and resin and mixed failure. Conclusions: Fiberglass post cementation using restorative and flowable bulk-fill composites with the individualization technique may be a promising alternative to existing methods of post cementation.

Radiopacity of restorative composites by conventional radiograph and digital images with different resolutions

  • Dantas, Raquel Venancio Fernandes;Sarmento, Hugo Ramalho;Duarte, Rosangela Marques;Meireles Monte Raso, Sonia Saeger;de Andrade, Ana Karina Maciel;Dos Anjos-Pontual, Maria Luiza
    • Imaging Science in Dentistry
    • /
    • 제43권3호
    • /
    • pp.145-151
    • /
    • 2013
  • Purpose: This study was performed to evaluate and compare the radiopacity of dentin, enamel, and 8 restorative composites on conventional radiograph and digital images with different resolutions. Materials and Methods: Specimens were fabricated from 8 materials and human molars were longitudinally sectioned 1.0 mm thick to include both enamel and dentin. The specimens and tooth sections were imaged by conventional radiograph using #4 sized intraoral film and digital images were taken in high speed and high resolution modes using a phosphor storage plate. Densitometric evaluation of the enamel, dentin, restorative materials, a lead sheet, and an aluminum step wedge was performed on the radiographic images. For the evaluation, the Al equivalent (mm) for each material was calculated. The data were analyzed using one-way ANOVA and Tukey's test (p<0.05), considering the material factor and then the radiographic method factor, individually. Results: The high speed mode allowed the highest radiopacity, while the high resolution mode generated the lowest values. Furthermore, the high resolution mode was the most efficient method for radiographic differentiation between restorative composites and dentin. The conventional radiograph was the most effective in enabling differentiation between enamel and composites. The high speed mode was the least effective in enabling radiographic differentiation between the dental tissues and restorative composites. Conclusion: The high speed mode of digital imaging was not effective for differentiation between enamel and composites. This made it less effective than the high resolution mode and conventional radiographs. All of the composites evaluated showed radiopacity values that fit the ISO 4049 recommendations.

Nanomechanical properties and wear resistance of dental restorative materials

  • Karimzadeh, A.;Ayatollahi, Majid R.;Nikkhooyifar, M.;Bushroa, A.R.
    • Structural Engineering and Mechanics
    • /
    • 제64권6권
    • /
    • pp.819-826
    • /
    • 2017
  • The effects of thermocycling procedure and material shade on the mechanical properties and wear resistance of resin-based dental restorative materials are investigated. The modulus of elasticity, hardness, plasticity index and wear resistance are determined for the conventional composite, the nanohybrid composite and the nanofilled dental composites. Disc-shape samples are prepared from each material to investigate the effects of thermocycling procedure on the mechanical properties and wear resistance of different types of dental restorative materials. In this respect, a group of samples is thermocycled and the other group is stored in ambient conditions. Then nano-indentation and nano-scratch tests are performed on the samples to measure their mechanical properties and wear resistance. Results show that the A1E shade of the dental nanocomposite possesses higher modulus of elasticity and hardness values compared to the two other shades. According to the experimental results, the mean values for the modulus of elasticity and hardness of the A1E shade of the nanocomposite are 13.71 GPa and 1.08 GPa, respectively. The modulus of elasticity and hardness of the conventional dental composite increase around 30 percent in the oral environment due to the moisture and temperature changes. The wear resistance of the dental composites is also significantly affected by moisture and temperature changes in the oral conditions. It is observed that thermocycling has no significant effect on the hardness, plasticity index and wear resistance of the nanohybrid composite and the nanocomposite dental materials.

용융침투법으로 제조한 인공치관용 스피넬/지르코니아-유리 복합체의 기계적 특성에 미치는 지르코니아 첨가효과 (Effect of Zirconia Addition on Mechanical Properties of Spinel/Zirconia-glass Dental Crown Composites Prepared by Melt-infiltration)

  • 이득용;김병수;장주웅;이명현;박일석;김대준
    • 한국세라믹학회지
    • /
    • 제39권11호
    • /
    • pp.1028-1034
    • /
    • 2002
  • 용융침투법을 이용 스피넬/지르코니아-유리 복합체를 제조하여 지르코니아 첨가가 복합체의 기계적 특성에 미치는 영향을 조사하였다. 유리 침투시간이 증가할수록 침투깊이는 Washburn식에 의한 포물선 관계로 증가하였으며 유리 침투상수 K는 기공 크기의 함수로 지르코니아 첨가량이 증가할수록 감소하였다. 지르코니아가 20 wt% 첨가되었을 때 스피넬/지르코니아-유리 복합체의 최적의 강도값(308 MPa)이 관찰되었지만 지르코니아 양이 증가함에 따라 유리 침투 상수와 투과율(transmittance)이 감소하였다. 지르코니아 첨가가 스피넬/지르코니아-유리 복합체의 기계적 특성 향상에 미치는 증진 효과는 크지 않은 것으로 관찰되었다.