• Title/Summary/Keyword: dental ceramic

Search Result 559, Processing Time 0.026 seconds

FLEXURE STRENGTH AND MICROSTRUCTURE OF IPS EMPRESS 2 GLASS-CERAMIC ON HEAT-PRESSING AND HEAT TREATMENTS (열가압 및 열처리에 따른 IPS Empress 2 세라믹의 굴곡강도와 미세구조)

  • Oh, Sang-Chun;Dong, Jin-Keun;Luthy, Heinz;Scharer, Peter
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.575-582
    • /
    • 2000
  • This investigation was designed to determine whether heat-pressing and/or simulated heat treatments affected the flexure strength and the microstructure of the lithium disilicate glass-ceramic in the IPS Empress 2 system. Four groups of the specimens were prepared as follows: group 1 - as-received material, group 2 - heat-pressed material; group 3 - heat-pressed and simulated initial heat-treated material; group 4 - heat-pressed and the simulated heat-treated material with full firings for a final restoration. The three-point bending test and the scanning elec-tron microscope (SEM) analysis was conducted for the purpose of this study. The flexure strength of group 2 was significantly higher than that of group 1. However, there were no significant differences in strength among group 2, 3, and 4, and between group 1 and 4. The SEM micrographs of the lithium disilicate glass-ceramic showed the closely packed, multi-directionally interlocking microstructure of numerous lithium disilicate crystals protruding from the glass matrix. The crystals of the heat-pressed materials (group 2, 3, and 4) were a little denser and about two times bigger than those of the as-received material (group 1). This change of microstructure is more obviously exhibited particularly between group 1 and 2. However, there was no a marked difference among group 2, 3, and 4 after the heat-pressing procedure. Although there were significant increase of the strength and some changes of the microstructure after the heat-pressing operation, the combination of the heat-pressing and the simulated subsequent heat treatments did not produce the increase of strength of IPS Empress 2 glass-ceramic.

  • PDF

A study on the difference of Ceramic fracture strength according to the metal depth (금속의 두께가 도재의 파절강도에 미치는 영향)

  • Shin, Mu-Hak;Choi, Un-Jae;Kim, Yoong-Won
    • Journal of Technologic Dentistry
    • /
    • v.27 no.1
    • /
    • pp.89-95
    • /
    • 2005
  • In the manufacture of ceramo-metal crown, difference of fracture strength according to the metal depth has been known to be an important influence on enough intensity and internal stress to endure an occlusion-pressure as well as aesthetics of rehabilitating similar colour such as natural teeth. Depth of ceramic material could be determined by that of metal in three groups: first case of thin depth, second case of thick depth, and third case of constant depth. For the enhancement of the fracture strength between metal and ceramic materials and aesthetic satisfaction, a study on the bonding force, fracture strength, and aesthetics have been required more. In this study, therefore metal coping were made in three groups of A, B and C by using both ceramic powder of Norithe and metal of Columbium, which have been used primarily in the market. A group was made in $0.2mm\times10mm\times10mm$, B group was made in $0.4mm\times10mm\times10mm$, and, C group was made in $0.8mm\times10mm\times10mm$, respectively. The number of metal coping in each group was 10, and total sample numbers used in this study were 30 metal copings. After these metal coping tissue were in the process of build-up in 1.5mm constant depth of porcelain, firing, and glazing, the fracture strength about each metal coping tissue was investigated using oil press. It was found that the average values of durable occlusion pressure for separation of ceramic material in the porcelain fused to metal crown (PFM) in the each group showed the increasing order of A group (30 bar), B group (42 bar), and C group (44 bar), respectively. Proper depth of metal coping in the PFM was considered to be 0.4mm in the B group because this metal size showed higher durable property to the occlusion pressure and better coupling strength in the ceramo-metal crown.

  • PDF

Bond and fracture strength of metal-ceramic restorations formed by selective laser sintering

  • Bae, Eun-Jeong;Kim, Ji-Hwan;Kim, Woong-Chul;Kim, Hae-Young
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.4
    • /
    • pp.266-271
    • /
    • 2014
  • PURPOSE. The purpose of this study was to compare the fracture strength of the metal and the bond strength in metal-ceramic restorations produced by selective laser sintering (SLS) and by conventional casting (CAST). MATERIALS AND METHODS. Non-precious alloy (StarLoy C, DeguDent, Hanau, Germany) was used in CAST group and metal powder (SP2, EOS GmbH, Munich, Germany) in SLS group. Metal specimens in the form of sheets ($25.0{\times}3.0{\times}0.5mm$) were produced in accordance with ISO 9693:1999 standards (n=30). To measure the bond strength, ceramic was fired on a metal specimen and then three-point bending test was performed. In addition, the metal fracture strength was measured by continuing the application of the load. The values were statistically analyzed by performing independent t-tests (${\alpha}=.05$). RESULTS. The mean bond strength of the SLS group (50.60 MPa) was higher than that of the CAST group (46.29 MPa), but there was no statistically significant difference. The metal fracture strength of the SLS group (1087.2 MPa) was lower than that of the CAST group (2399.1 MPa), and this difference was statistically significant. CONCLUSION. In conclusion the balling phenomenon and the gap formation of the SLS process may increase the metal-ceramic bond strength.

Gross-β Level in Dental Ceramic Materials (치과용 세라믹 재료의 전β 방사능 준위)

  • Kim, Sung-Hwan;Jeong, Hyun-Ja
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.12
    • /
    • pp.4819-4825
    • /
    • 2010
  • In all of dental ceramics, these materials contained the radio-isotopes with natural abundance ratio. After dental treatment, remained dental ceramics in the oral cavity is caused for human internal dose. In this study, the gross beta activity levels were measured in dental materials including 22 dental ceramics, 1 resin, and 2 cements for estimation of human internal dose. In dental ceramic samples, the obtained results showed that the gross beta activity level varied between 1.317 ~ 2.935 Bq/g and the gross beta activity level was 2.379 Bq/g. And the same level for dentine, opacious dentine, translucent and enamel were 2.479 Bq/g, 2.491 Bq/g, 2.470 Bq/g and 2.069 Bq/g, respectively. The gross beta activity level of temporary resin and cements were negligible, compare to the same level of dental ceramics. The high gross beta activity level observed in opacious dentine code OD-A4 is 2.935 Bq/g thus mainly ascribable to 40K. The reduction of the radiation level of natural radio-isotopes and the improvement of the dental ceramic materials should be required for internal dose reduction.

A study on the visible wave of transmittance pressable ceramic core (열가압성형도재 코어의 가시광선 투과율에 관한 연구)

  • Jung, In-Ho;Lee, Sang-Deok;Nam, Sang-Yong
    • Journal of Technologic Dentistry
    • /
    • v.34 no.1
    • /
    • pp.1-9
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the transmittance differences of pressable ceramic core due to thickness within the visible light spectrum. Methods: 36 specimens were divided into 2 groups (0.6mm, 0.8mm) which have each 3 specimens. The size of specimens was 10mm high and 10mm wide. The transmittance of specimens are measured by spectrophotometer Model Cary 500 that can measure infrared-ray, visible wave and ultraviolet-ray. Results: The results shows that there was no significant difference between specimen's thickness(0.6mm, 0.8mm) and transmittance. Conclusion: The individual's color perception is personal and there are numerous factors that influence on it. In general, human eye can perceive the color of thing only within visible light spectrum but in this experiment through spectrophotometer there was no big difference between specimen's thickness(0.6mm, 0.8mm) and transmittance. To sum up, The most important factors were a layed porcelain structure and its thickness rather than core thickness in the porcelain crown. Also, When making all ceramic core with dead pulp (nervous treatment tooth) when used as a restorative esthetic think is more efficient to improve.

Comparison of the Marginal Fitness of Ceramic Co-Cr Metal Crown (도재용 코발트-크롬 금속관의 변연적합도 비교)

  • Jeon, Byung-Wook;Kim, Bu-Sob
    • Journal of Technologic Dentistry
    • /
    • v.37 no.2
    • /
    • pp.69-76
    • /
    • 2015
  • Purpose: In this study, the marginal fitness of ceramic Co-Cr metal crown made by precision casting, milling, and selective laser melting method were compared. Methods: The ceramic Co-Cr metal crown manufactured by precision casting used the lost wax(LC specimen) method. The abutment were scanned and then made by milling(CM specimen), selective laser melting(CS specimen) method. The specimen were cut bucco-lingual and mesio-distal, and absolute marginal discrepancy and marginal gap were measured using a digital microscope. The surface roughness of the crown was also observed. Results: On the bucco-lingual axial, absolute marginal discrepancy was the LC specimen $31.72({\pm}4.58){\mu}m$, the CM specimen $78.29({\pm}3.28){\mu}m$ and the CS specimen $143.13({\pm}3.83){\mu}m$, respectively. On the bucco-lingual axial, marginal gap was the LC specimen $22.70({\pm}1.46){\mu}m$, the CM specimen $22.70({\pm}1.49){\mu}m$ and CS specimen $99.60({\pm}1.57){\mu}m$, respectively. Conclusion: For ceramic Co-Cr metal crowns, LC specimen was superior for absolute marginal discrepancy and marginal gap. The surface of metal crowns by selective laser melting were the roughest.

Effec of different zirconia primers on shear bond strengths of composite resin to bonded zirconia (지르코니아 프라이머 종류에 따른 복합레진-지르코니아의 전단결합강도)

  • Shi, Hong-Bing;Kim, Tae-Seok;Ahn, Jae-Seok;Lee, Jung-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.135-142
    • /
    • 2016
  • Purpose: The aim of this research was to evaluate the influence of different surface treatments on the shear bond strength of zirconia ceramic to composite resin. Methods: Seventy two cylinder-shape (diameter: 5 mm; height: 12 mm) blocks of experimental industrially manufactured Y-TZP ceramic were abraded with $125{\mu}m\;Al_2O_3$ particles and randomly divided into 4 groups. All the materials were categorized as group Gc(control group - composite resin veneering on zirconia surface), Gr - composite resin veneering after surface treatment of Rocatec system (3M ESPE, Seefeld, Germany) group; Gz - composite resin veneering after surface treatment of Zirconia primer (Z-primer, Bisco, U.S.A) group; Gm - composite resin veneering after surface treatment of zirconia primer (Monobond plus, ivoclar vivadent AG, Liechtenstein) group. Two different zirconia primers and Rocatec system were used to zirconia cylinders (n=16) onto the zirconia surface. Zirconia specimens, polished and roughened, were pretreated and composite bilayer cylinders bonded using conventional adhesive techniques. Results: Shear bond strengths were analyzed using single-factor ANOVA(p<0.05). Bond strength values achieved after airbone particle abrasion and zirconia surface pre-treatments(p<0.05). Conclusion: Shear bond strength tests denmonstrated that zirconia primer is a viable method to improved bond strength between zirconia ceramic core and veneering composites.

COMPARATIVE STUDY OF FRACTURE STRENGTH DEFENDING ON THE THICKNESS OF SOME ALL CERAMIC CORES (수종의 전부도재관 코어의 두께에 따른 파절강도의 비교 연구)

  • Kim Doo-Yong;Lee Young-Soo;Park Won-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.49-57
    • /
    • 2004
  • Statement of problem : The increased awareness of esthetics in dentistry has brought the esthetic consideration in prosthetic restorations . Dental ceramics offer better esthetics for use of prosthetic restorations. Unfortunately, dental ceramic materials are not always the most suitable candidate materials since their inherently brittle nature. In recent years, basic research in ceramic science has led to the recognition or several approaches to strengthen and to enhance esthetics of ceramics. Several all ceramic systems use ceramic core and porcelain build up structures . Ceramic cores influence to strength of all ceramic crowns . So the strength of ceramic cores is important to all ceramic crowns. Purpose : The purpose of this study is to estimate the flexural strength of ceramic cores in some all ceramic systems. Material and method : A biaxial flexure test was conducted on three groups(Cergo, Empress 2, In-Ceram). Each group consisted of 30 discs of nearly identical dimension with a 0.5mm, 1.0mm, 1.5mm thickness and 12mm in diameter. The fracture load was recorded by Instron. Analysis of valiance(ANOVA) and Tukey's tests were performed using SAS statistical software. Results : 1.5mm thickness of specimens were significantly stronger than 0.5mm and 1.0mm thickness of specimens in Cergo and In-Ceram. But each sepecimen group of Empress 2 was no significantly strength by thickness. In order of In-Ceram, Empress 2 and Cergo has significantly stronger strength in the same thickness. Conclusion : In-Ceram is the strongest ceramic material in 3 materials. All the materials can be used according to the required characters.

The research about the physical properties and flexural strength changed by Low Temperature Degradation of TZP monolithic all-ceramic crown block to make bio-prosthetic dentistry (치과용 생체보철물 제작을 위한 TZP 단일구조 전부도재관 블럭의 물성과 저온열화 후 굴곡강도에 관한 연구)

  • Lee, Jong-Hwa;Park, Chun-Man;Song, Jae-Sang;Lim, Si-Duk;Kim, Jae-Do;Kim, Byung-Sik;Hwang, In-Whan;Lee, Sung-Kuk
    • Journal of Technologic Dentistry
    • /
    • v.34 no.2
    • /
    • pp.83-93
    • /
    • 2012
  • Purpose: The objective of this study is to find out physical properties and the flexural strength changed by the low temperature degradation of the block which is needed to make bio-prosthetic dentistry which is better than feldspar affiliated ceramic made by building up ceramic powder and also to apply this to the clinical use of zirconia monolithic all-ceramic crown. Methods: Flexural strength of each sample was evaluated before and after the Low Temperature Degradation, and physical properties of the Tetra Zirconia Block containing 3mol % was evaluated as well. The average and standard deviation of each experimental group were came out of the evaluation. Statistical package for social science 18.0 was used for statistics. Results: The average density of the monolithic all-ceramic crown was $6.0280{\pm}0.0147g/cm$, the relative density was 99.01 %. When the sample was sintered at $1480^{\circ}C$ the diameter of average particle was $396.62{\pm}33.71nm$. All the samples had no monolithic peak after XRD evaluation but only had tetragonal peak. There were statistically significant differences in the result of flexural strength of the samples evaluated after and before the low temperature degradation, the flexural strength before the low temperature degradation was $1747.40{\ss}{\acute{A}}$, at the temperature of $130^{\circ}C$ the flexural strength after the low temperature degradation was 1063.99MPa (p<0.001). There was statistically significant difference in the result of strength of 1020.07MPa after the low temperature degradation at the temperature of $200^{\circ}C$ (p<0.001). Conclusion: The block which was made for this evaluation possesses such an excellent strength among dental restorative materials that it is thought to have no problems to use for tetragonal zirconia polycrystal.

A study on ceramic shade prescriptions for work authorizations (도재 보철물 색조의 처방에 관한 고찰)

  • Sung, Hwan-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.10 no.1
    • /
    • pp.177-183
    • /
    • 1988
  • This paper aims to examine ceramic shade prescriptions for work authorizations in all its aspectclincal information, recording information, technical considerations, extended application, practical applications. The results are as follows : 1. The basic application provides essential data for ceramic veneer fabrication. 2.Three-dimensional information divides the space for body and enamel components. 3. The second body shade selection improves shade matching in the middle one-third of the tooth and enhences the appearance of the enamel component. 4. Ceramists are encouraged to recognize the influence each component has upon the total shade composition. 5. A format is established for recording clinical information. 6. The use of available ceramic systems is seemingly unlimited. The method presented provides flexisility for recording the most detailed shade information in simple graphic and verbal terms. 7. Technical simplification is a by-product of complete, precise work information.

  • PDF