• Title/Summary/Keyword: dental Lab.

Search Result 305, Processing Time 0.021 seconds

The effort and agony of dental laboratory for the balanced proportions of dental prosthesis. (보철물의 균형감을 위한 lab side의 고민과 노력)

  • Lee, Seung Sub;Pea, Young Hwan
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.29 no.2
    • /
    • pp.75-83
    • /
    • 2020
  • For the successful prosthetics treatment, the collaboration starting from the initial stage between dental clinic and laboratory is important. However, the collaboration can't persist all the processes, giving the ideal shape to prosthetics is one of the responsible part of dental laboratory. I'm going to explain how to access dental technician to case in restricted circumstance.

Study of the safety education condition and injury occurrence in dental technicians- in Seoul and Gyeonggi (치과기공사의 안전교육 실태 및 상해발생 조사연구 -서울·경기 지역을 중심으로)

  • Kim, Jin;Choi, Se-Woong;Shin, Su-Jeong;Cho, Yoon-Sang;Lim, Su-Min;Shim, Jeong-Seok;Lee, Jung-Soo;Bae, Eun-Jeong
    • Journal of Technologic Dentistry
    • /
    • v.39 no.3
    • /
    • pp.179-185
    • /
    • 2017
  • Purpose: It is intended to raise awareness of importance of protective equipment and necessity of safety education by examining the actual condition of measures to deal with accident, occurrence of injury, whether safety education is received or not, the actual condition of wearing protective equipment, and working environment of dental lab and dental technician. Methods: A self-administered survey was conducted for a total of 150 dental technologists. A chi-squared test and independent-samples t-test was carried out by using SPSS WIN Program (version 12.0) in order to analyze the actual condition of safety education according to work experience and position and whether injury occurred according to whether to wear protective equipment. Significance level was 0.05. Results: With regard to whether injury occurred according to whether safety education was received, there was 'receiving the safety education-injured (71.8%)', 'not receiving the safety education-injured (79.7%)', 'receiving the safety education-not injured (28.2%)', and 'not receiving the safety education-not injured (20.3%)'. The statistical results of injury occurrence according to safety education were not significant. With regard to whether to be injured according work experience, there was 'less than 10 years-injured (68.4%)', 'less than 10 years- not injured (31.6%)', '10 years or above-injured (89.1%)', and '10 years or above-not injured (10.9%)'. The statistical results of injury occurrence according to work experience were significant (p<0.001). Conclusion: Dental lab and specialized agencies should continue to be interested in periodic safety training, recommending wearing protective equipment and personal protective equipment support and so on.

Physical properties of composite resins for dental restorative (치과 수복재용 복합레진의 물리적 특성에 대한 연구)

  • Kim, Ji Yeob;Lee, Kwang-Rae
    • Journal of Industrial Technology
    • /
    • v.35
    • /
    • pp.35-39
    • /
    • 2015
  • One of the purposes of the study was to investigate and compare the physical properties(depth of light cure, degree of conversion, water absorption) of 4 kinds of composit resins prepared in this lab; Bis-GMA based, Bis-EMA based, Bis-GMA/UDMA based, and Bis-EMA/UDMA based composit. Another aim was to compare the physical properties of the composit resins with those of the commercialized products(Charmfil flow(Denkist), Quadrant flow(CAVEX)) in market. All of the composit resins and the commercialized products showed almost same values of the physical properties. It was found that all of the composit resins prepared in this lab satisfied the physical properties specified in ISO 4049.

  • PDF

Characterization and Genetic Profiling of the Primary Cells and Tissues from Mandible of Mouse Fetus and Neonate

  • Kang, Jung-Han;Nam, Hyun;Park, Soon-Jung;Oh, Keun-Hee;Lee, Dong-Seup;Cho, Jae-Jin;Lee, Gene
    • International Journal of Oral Biology
    • /
    • v.32 no.1
    • /
    • pp.13-22
    • /
    • 2007
  • The stem cell research is emerging as a cutting edge topic for a new treatment for many chronic diseases. Recently, dental stem cell would be possible for regeneration of tooth itself as well as periodontal tissue. However, the study of the cell characterization is scarce. Therefore, we performed the genetic profiling and the characterization of mouse fetus/neonate derived dental tissue and cell to find the identification during dental development. We separated dental arch from mandibles of 14.5 d fetal mice and neonate 0 d under the stereoscope, and isolated dental cells primarily from the tissues. Then, we examined morphology and the gene expression profiles of the primary cells and dental tissues from fetus/neonate and adult with RT-PCR. Primary dental cells showed heterogeneous but the majority was shown as fibroblast-like morphology. The change of population doubling time levels (PDLs) showed that the primary dental cells have growth potential and could be expanded under our culture conditions without reduction of growth rate. Immunocytochemical and flow cytometric analyses were performed to characterize the primary dental cell populations from both of fetus (E14.5) and neonate. Alpha smooth muscle actin (${\alpha}-SMA$), vimentin, and von Willebrand factor showed strong expression, but desmin positive cells were not detected in the primary dental cells. Most of the markers were not uniformly expressed, but found in subsets of cells, indicating that the primary dental cell population is heterogeneous, and characteristics of the populations were changed during culture period. And mesenchymal stem cell markers were highly expressed. Gene expression profile showed Wnt family and its related signaling molecules, growth factors, transcription factors and tooth specific molecules were expressed both fetal and neonatal tissue. The tooth specific genes (enamelin, amelogenin, and DSPP) only expressed in neonate and adult stage. These expression patterns appeared same as primary fetal and neonatal cells. In this study we isolated primary cells from whole mandible of fetal and neonatal mice. And we investigated the characteristics of the primary cells and the profile of gene expressions, which are involved in epithelial-mesenchymal interactions during tooth development. Taken together, the primary dental cells in early passages or fetal and neonatal mandibles could be useful stem cell resources.

Evaluation of Corrosion Resistance of Ti-Zr-Nb-Pd Based Alloys for Biomedical applications by electron Theory (전자론에 의한 생체용 Ti-Zr-Nb-Pd계 합금의 내식성 평가)

  • Jung, Jong-Hyun;Sun, Gum-Ju
    • Journal of Technologic Dentistry
    • /
    • v.26 no.1
    • /
    • pp.35-40
    • /
    • 2004
  • In order to understand alloying effects on the corrosion resistance of Ti-(10$\sim$20)%Zr-(2$\sim$8%)Nb-0.2%Pd alloys, Polarization curves were measured at 5%HCI solution. The results were interpreted in terms of two parameters obtained by the molecular orbital calculation ; one is the bond order($B_{\circ}$) and the other is the metal d-orbital level($M_{d}$). $B_{\circ}$ is a measure of the strength of covalent bonds between titanium and alloying elements. $M_{d}$ is correlative with the electronegativity of elements. It was found that increasing of Zr and Nb with higher $B_{\circ}$ values showed a lower critical anodic current density in the polarization curve and hence higher corrosion resistance. On the other hand, increasing of Zr and Nb with higher $M_{d}$ values showed a higher corrosion resistance.

  • PDF

An analysis of marginal adaptation of metal cores fabricated by selective laser sintering (레이저선택용융기술에 의해 제작된 금속 코어의 변연 적합도 분석)

  • Kim, Won-Soo;Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.38 no.4
    • /
    • pp.305-311
    • /
    • 2016
  • Purpose: The purpose of this study were to analysis of marginal adaptation of metal cores fabricated by selective laser sintering. Methods: Main model was prepared and ten stone models were fabricated. Ten single metal cores were fabricated by selective laser sintering(SLS group) and another ten single metal cores using lost wax technique and casting method were manufactured(CAST group). The marginal adaptation of metal cores were analysis using by the silicone replica technique. Silicone replicas were sectioned two times. The marginal adaptations were measured using by digital microscope. Statistical analyses was performed with independent t-test(${\bullet}{\cdot}=0.05$). Results: Means of marginal adaptations were 90.3 ${\ss}{\uparrow}$ for SLS group and 65.1 ${\ss}{\uparrow}$ for CAST group. Two groups were statistically significant differences (p < 0.05). Conclusion: Marginal adaptation of metal cores fabricated by selective laser sintering were ranged within the clinical recommendation.

Comparison the fit of three-unit metal framework fabricated by wax milling method and digital light projection method (왁스 밀링 방법 및 디지털 광 프로젝션 방법으로 제작된 3본 금속 구조물의 적합도 비교)

  • Lee, Jung-Hwan;Ahn, Jae-Seok
    • Journal of Technologic Dentistry
    • /
    • v.41 no.1
    • /
    • pp.9-19
    • /
    • 2019
  • Purpose: This study was conducted to comparative evaluate the marginal and internal gap of three-unit metal frameworks(Co-Cr) fabricated by wax milling method and digital light projection method of CAD/CAM systems. Methods: All the specimens were fabricated by three different fabrication methods: conventional wax up with casting(CWC), milled wax block with casting(MWC), digital light projection with casting(DLPC) (n=10 each). The marginal and internal fits of specimens were examined using a replica technique. The light-body silicone thickness was measured at 8 reference points(each abutment: 16 measurements). All measurements were conducted by a stereomicroscope. Digital photo were taken at $150{\times}$ magnification and then analyzed using a measurement software. The Mann-Whitney test was used for analyzing the results. Results: Statistically significant differences were found between the fabrication methods(p<0.001). The mean(SD) is ${\mu}m$ for fabrication methods, the mean marginal fit were recorded respectively, CWC 63(38), MWC group 50(33), DLPC 103(54) and the mean internal fit CWC 96(47), MWC group 116(41), DLPC 138(66). Conclusion : The marginal and internal fit were statistically different according to the fabrication methods(p<0.001). In all fabrication methods, the greatest misfit was found the occlusal area of all specimens.

Scalp injury management by a maxillofacial surgeon in a low-resource hospital

  • Frimpong, Paul;Nguyen, Truc Thi Hoang;Nimatu, Edinam Salia;Amponsah, Emmanuel Kofi;Kim, Soung Min
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.42
    • /
    • pp.39.1-39.5
    • /
    • 2020
  • Background: Head or scalp injury is a life-threatening and typically accidental human injury. Most medical departments require immediate medical treatment and proper treatment with specialized medical personnel and facilities. However, in low-resource environments, such as the rural region of West Africa, the authors have treated emergency trauma patients and provided immediate treatment despite lack of resources. Case presentation: We reviewed three cases of scalp injury patients, with representative clinical information, and used these cases to outline feedback on scalp trauma treatment based on the specialty knowledge of general and emergency surgeon. Conclusions: Oral and maxillofacial surgeons are medical specialists that can immediately diagnose and treat these scalp injuries based on their medical knowledge and experience with the maxillofacial region.

Regional anesthesia for maxillofacial surgery in developing countries

  • Kim, Soung Min;Seo, Mi Hyun;Myoung, Hoon;Lee, Jong Ho
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.16 no.4
    • /
    • pp.245-252
    • /
    • 2016
  • Regional anesthesia in the maxillofacial region is safer and more efficient than general anesthesia when its indications are carefully considered. In addition, the majority of medical institutions in developing countries are not well equipped for proper anesthesia and elective surgery. In this review, we describe regional anesthesia and cutaneous nerve divisions in the maxillofacial region. In addition, we summarize detailed regional anesthetic techniques adapted for representative cleft lip cases in developing countries.

Mechanical Properties of Ti-20%Zr-X%Cr(X=0,5) Based Alloys for Dental Casting (치과주조용 Ti-20%Zr-X%Cr(X=0,5)계 합금의 기계적 성질)

  • Jung, Jong-Hyun
    • Journal of Technologic Dentistry
    • /
    • v.25 no.1
    • /
    • pp.81-87
    • /
    • 2003
  • Ti-20%Zr-X%Cr(X=0,5) based alloys not containing hamful Al and V were newly designed in order to reveal their possibility for dental casting alloys, and melted in argon-arc casting machine. The mechanical properties were evaluated by using universal testing machine. The tensile strength and %elongaton of the alloys markedly increased with Cr content. The Ti-20%Zr-5%Cr alloy showed a similar tendency with Ti-6%Al-4%V alloy in tensile strength, but surpassed in %elongation. From these results, it was concluded that new alloys for successful dental casting materials should be designed as Ti-Zr-Cr based alloys.

  • PDF