Design of Multi-node Real-time Diagnostic and Management System Using Zigbee Sensor Network (Zigbee 센서 네트워크를 활용한 다중노드 실시간 진단 및 관리시스템 설계)

  • Kang, Moonsik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.6
    • /
    • pp.152-161
    • /
    • 2014
  • In this paper, a multi-node real-time diagnostic and management system based on zigbee sensor network is proposed, which is to monitor and diagnose multiple nodes as well as to control the data generated from the various multiple sensors collectively. The proposed system is designed to transmit the collected wireless and wired data to the server for monitoring and controling efficiently the condition for multi-nodes by taking the corresponding actions according to the analysis. The system is implemented to make it possible to manage the sensor data by classifying them, of which data are issued from the clustered sources with a number of the remote sensors. In order to evaluate the performance of the proposed system, we measure and analyze both the transmission delay time according to the distance and the data loss rate issued from multiple sensors. The results shows that the proposed system has a good performance.

A Range-based Relay Node Selecting Algorithm for Vehicular Ad-hoc Network (차량 애드혹 네트워크를 위한 영역 기반 릴레이 노드 선택 알고리즘)

  • Kim Tae-Hwan;Kim Hie-Cheol;Hong Won-Kee
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.9 s.351
    • /
    • pp.88-98
    • /
    • 2006
  • VANET has several different characteristics from MANET such as high mobility of nodes and frequent change of node density and network topology. Due to these characteristics, the network topology based protocol, often used in MANET, can not be applied to VANET. In this paper, we propose an emergency warning message broadcast protocol using range based relay node selecting algorithm which determines the minimal waiting time spent by a given node before rebroadcasting the received warning message. Because the time is randomly calculated based on the distance between sender node and receiver node, a node chosen as a relay node is assured to have a minimal waiting time, even though it is not located at the border of radio transmission range. The proposed emergency warning message broadcast protocol has low network traffic because it does not need to exchange control messages for message broadcasting. In addition, it can reduce End-to-End delay under circumstances of low node density and short transmission range in VANET.

Adaptive Dynamic Slot Assignment of VBR Traffics Using In-band Parameters in Wireless ATM (무선 ATM에서 In-Band 파라미터를 이용한 VBR 트래픽의 적응적 슬롯 할당)

  • Paek, Jong-Il;Jun, Chan-Yong;Kim, Young-Chul
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.39 no.7
    • /
    • pp.30-37
    • /
    • 2002
  • In this paper, we propose a new adaptive slot assignment algorithm called In-VDSA in order to guarantee the QoS(Quality of Service) of VBR(Variable Bit Rate) traffics in wireless ATM and maximize efficiency in use of wireless channels. In the proposed algorithm, the status of terminal buffers is encoded in signed number on the GFC(Generic Flow Control) field of an ATM cell header and piggybacked. And also, the number of slots to be assigned to the next frame is adjusted effectively, which is different to methods in the conventional slot assignment algorithms. As a result, we can guarantee QoS such as CLR(Cell Loss Rate) and cell delay and achieve the higher utilization of channels. The validity of the proposed algorithm has been justified in performance by analysis through simulation results using the BONeS tool and comparison with conventional methods.

ACUTE RESPONSE OF THE RAT INCISOR BY SINGLE AND FRACTIONATED IRRADIATION (단일 및 분할 방사선조사에 의한 백서절치의 급성반응에 관한 연구)

  • Rhee In-Suk;Park Tae-Won;Ahn Hyung-Kyu
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.19 no.1
    • /
    • pp.39-48
    • /
    • 1989
  • Six to eight-month-old female albino rats were used as experimental animals. As an irradiation equipment, a Co-60 was used. The experimental animals were divided to; 6 of the control group, 12 of the 500cGy single irradiation group, 12 of the 1000cGy fractionated irradiation group, and 12 of the 1500cGy fractionated irradiation group. From the first week to the forth, 3 rats were picked from each group every week to be sacrificed and fixed with formalin. Those rats were observed by means of H-E stain after being taken radiograph and decalcified. The analysis of radiographic findings and light microscopic findings gives results as follows: 1. The delay of dental eruption rate was found in every group which underwent the irradiation experiment. Dentin niche, osteodentin, and dentin island were formed in the parts which were damaged by the irradiation. 2. The longer the observation period was, the more deposit of osteodentin and dentin island was formed. 3. In the single irradiation group, the damage effect was in proportion to the increase of radiation dose, whereas the damage was much less in the fractionated group receiving the same dose. 4. The 500cGy single irradiation group got temporary repairable damage, while the 1000cGy single irradiation group got considerable damage and showed much slower eruption rate than the 500cGy single irradiation group. The basal portion of the 1500cGy single irradiation group, whose growth was arrested, was destroyed. 5. The fractionated group were irradiated 500cGy everyweek. Repair was visible during the interval periods. The damage was accumulated as irradiation repeated, but degree of damage was lower than that of the 1000cGy and 1500cGy single irradiation group.

  • PDF

Design of Nonuniform Coupled Line-Type Transversal Filters Using Improved Woodward-Lawson Sampling Method (개선된 Woodward-Lawson 샘플링법을 사용한 불균일 결합선로형 트랜스버설 필터 설계)

  • Jeung Hyun-Soo;Jun Sang-Jae;Park Eui-Joon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.2 s.93
    • /
    • pp.120-127
    • /
    • 2005
  • The design method of the transversal filter using continuously cascaded directional couplers is presented. The coupler can be treated for a continuously varying nonuniform coupled transmission line. The design method is based on the optimum extraction of desired coupling factor by the control of null positions which are inherent to the coupling spectra pattern. In the optimization process, the improved Woodward-Lawson sampling method is applied to easily synthesize the distributed delay and weighting elements for transversal filter properties. For application, the microstrip transversal filter is fabricated and optimum dielectric overlay is introduced for the mode phase velocity compensation for non-TEM coupler nodes by using SDA(Spectral Domain Approach). Experiment results confirm the validity of the proposed method.

Stacked LTCC Band-Pass Filter for IEEE 802.11a (IEEE 802.11a용 적층형 LTCC 대역통과 여파기)

  • Lee Yun-Bok;Kim Ho-Yong;Lee Hong-Min
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.2 s.93
    • /
    • pp.154-160
    • /
    • 2005
  • Microwave Otters are essential device in modem wireless systems. A compact dimension BPF(Band-pass Filter) for IEEE 802.11a WLAN service is realized using LTCC multi-layer process. To extrude 2-stage band-pass equivalent circuit, band-pass and J-inverter transform applied to Chebyshev low-pass prototype filter. Because parallel L-C resonator is complicate and hard to control the inductor characteristics in high frequency, the shorted $\lambda/4$ stripline is selected for the resonator structure. The passive element is located in the different layers connected by conventional via structure and isolated by inner GND. The dimension of fabricated stacked band-pass filter which is composed of six layers, is $2.51\times2.27\times1.02\;mm^3$. The measured filter characteristics show the insertion loss of -2.25 dB, half-power bandwidth of 220 MHz, attenuation at 5.7 GHz of -32.25 dB and group delay of 0.9 ns at 5.25 GHz.

Wall Shear Stress Between Compliant Plates Under Oscillatory Flow Conditions: Influence of Wall Motion, Impedance Phase Angle and Non-Newtonian Fluid (맥동유동하에 있는 유연성 있는 평판 사이의 벽면전단응력: 벽면운동과 임피던스 페이즈 앵글과 비뉴턴유체의 영향)

  • Choe, Ju-Hwan;Lee, Jong-Seon;Kim, Chan-Jung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.1
    • /
    • pp.18-28
    • /
    • 2001
  • The present study investigates flow dynamics between two dimensional compliant plates under sinusoidal flow conditions in order to understand influence of wall motion, impedance phase angle (time delay between pressure and flow waveforms), and non-Newtonian fluid on wall shear stress using computational fluid dynamics. The results showed that wall motion induced additional terms in the streamwise velocity profile and the pressure gradient. These additional terms due to wall motion reduced the amplitude of wall shear stress and also changed the mean wall shear stress. The trend of the changes was very different depending on the impedance phase angle. As the impedance phase angle was changed to more negative values, the mean wall shear stress decreased while the amplitude of wall shear stress increased. As the phase angle was reduced from 0°to -90°under $\pm$4% wall motion, the mean wall shear stress decreased by 12% and the amplitude of wall shear stress increased by 9%. Therefore, for hypertensive patients who have large negative phase angles, the ratio of amplitude and mean of the wall shear stress is raised resulting in a more vulnerable state to atherosclerosis according to the low and oscillatory shear stress theory. We also found that non-Newtonian characteristics of the blood protect atherosclerosis by decreasing the oscillatory shear index.

A Study on the Performances of Pullets and Subsequent Egg Production with the Substitution of Ground Sunflower Seeds (해바라기씨앗으로 사육된 병아리의 성장 및 산란계로서의 생산능력에 관한 연구)

  • K. H. Nahm
    • Korean Journal of Poultry Science
    • /
    • v.17 no.4
    • /
    • pp.281-283
    • /
    • 1990
  • Ten-week-old layer type pullets were used in this study, housed 10 birds per cage(61$\times$41cm) and were replicated 15 times After raising them on a 19% protein diet up to ten weeks of age they were fed a 12% protein corn-soy control diet or one with half or all of the soybean mea replaced with ground full-fat sunflower seeds. At 19 weeks of age, pulltes were transferred to a layer house and their respective diet was gradually changed to a 13.5% layer diet containing 635% oats. The 19% protein SFS diet in treatment 2 did not show my, adverse effect on body weight or subsequent egg productio. The higher level of SES(38%) appeared to delay sexual maturity somewhat as was indicated by body weight and egg production data. However, the higher replacement of soybean with SFS(38%) in the pullet ration may not be critical for sexual maturity, but beneficial in a full laying cycle. There were no adverse effects on later stages of production.

  • PDF

An Investigationi into the Dynamic Characteristics of Turbine and Gear Motor Type Flowmeters (터빈형과 기어모터형 유량계의 동특성 검토)

  • 예용택
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.3
    • /
    • pp.83-89
    • /
    • 2000
  • In hydraulic control system turbine and gear motor type flowmeters are widely used to measure the flow rate under steady flow conditions. With the recent growth of interest in the measurement of instantaneous values of unsteady flow rate the test of the transient response of these flowmeters are in some significance. however an unsteady flow rate mea-surment and its calibration method with a fast response and a high accuracy have not beendeveloped. In this research particularly the dynamic characteristics of turbine and gear motor type flowmeters are investigated experimentally and simple mathematical models are proposed. The measured flow rate waveforms are compared with those by remote instan-taneous flow rate measurement method(RIFM) which has been developed by author and used for calibration As the result of frequency response test gain and phase between the measured flow rate waveforms by turbine type flowmeter and those estimated by RIFM are in good agreement up to 70Hz For the gear motor type flowmeter th simulated results by a math-ematical model proposed here agree well with the experiment nearly up to 100Hz. Also it if sound that the pressure drop across the flowmeter is increased in proportion to the frequency of the flow rate variation in a high frequency region of more than 100Hz. It can be explained that the dealy of gear motor type flowmeter in high frequency regionis mainly attributed to a first order delay consisting of the inertia of gears and internal leakage of the gear motor.

  • PDF

Study on Enhancements to Ultrasonic Data Imaging Using Full Matrix Capture Technique (Full Matrix Capture 기법을 통한 초음파신호 영상화 향상 연구)

  • Lee, Tae-Hun;Yoon, Byung-Sik;Lee, Jeong-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.5
    • /
    • pp.299-306
    • /
    • 2015
  • A conventional phased array system can control an ultrasonic beam electronically by adjusting the excitation time delay of individual elements in a multi-element probe and produce an ultrasonic image. In Contrast, full matrix capture (FMC) is a data acquisition process that allows receiving ultrasonic signals from one single shot of the phased array transducer element through all the other elements and captures the complete dataset from every possible transmit-receive combination. This FMC data can be used to create the ultrasonic image in post processing. It is possible to produce not only images equivalent to conventional phased array image but also total focusing method (TFM) images with improved resolution and sharpness, which is virtually focused at any point in a region of interest. In this paper, the system that can perform FMC by using a conventional phased array instrument is developed, and a study was conducted on the imaging algorithms to reconstruct sector B-scan and TFM images from FMC dataset.