• Title/Summary/Keyword: degree of contamination

Search Result 337, Processing Time 0.028 seconds

Survey of the Presence of Aflatoxins in Compound Feeds and Feed Ingredients (국내생산 사료의 Aflatoxin 오염도 조사)

  • Jang, Han-Sub;Jo, Hyun-Jung;Lee, Kyung-Eun;Lee, Chan
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.4
    • /
    • pp.346-352
    • /
    • 2007
  • Contamination of aflatoxins(AFs) was monitored in 447 compound feeds and 138 feed ingredients samples distributed in South KOREA in 2006 and 2007. The degree of $AFB_1\;and\;AFB_2$ contamination in compound feed was 20% and 3%, respectively. The levels of detection were ranged from 0.48 to 10.46 ppb for $AFB_1$ and from 0.25 to 0,42 ppb for $AFB_2$. Thirty eight percent of compound feeds were contaminated with $AFB_1$ at concentration between 0.43 and 5.52 ppb and $AFB_2$ was detected in 2% of compound feeds at levels ranging 0.26-0.40 ppb. The highest degree of $AFB_1$ contamination was observed in compound feeds for beef cattle (75%) followed by for dairy cattle (72%) and in bran among feed ingredients (30%). Bran exhibited the highest level of $AFB_1$contamination (3.1 ppb). Vegetable proteins and compound feeds for dog showed relative lower degree of contamination at 2.9 and 1.9 ppb, respectively. $AFG_1\;and\;AFG_2$ were not detected in any compound feeds and feed ingredients samples.

Quantification of Uncertainty Associated with Environmental Site Assessments and Its Reduction Approaches (부지 오염도 평가시 불확실성 정량화 및 저감방안)

  • Kim, Geonha;Back, JongHwan;Song, Yong-Woo
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.1
    • /
    • pp.26-33
    • /
    • 2014
  • Uncertainty associated with a sampling method is very high in evaluating the degree of site contamination; therefore, such uncertainty affects the reliability of precise investigation and remediation verification. In particular, in evaluating a site for a small-sized filling station, underground utilities, such as connection pipes and oil storage tanks, make grid-unit sampling impossible and the resulting increase in uncertainty is inevitable. Accordingly, this study quantified the uncertainty related to the evaluation of the degree of contamination by total petroleum hydrocarbon and by benzene, toluene, ethylene, and xylene. When planning a grid aimed at detecting a hot spot, major factors that influence the increase in uncertainty include grid interval and the size and shape of the hot spot. The current guideline for soil sampling prescribes that the grid interval increase in proportion to the area of the evaluated site, but this heightens the possibility that a hot spot will not be detected. In evaluating a site, therefore, it is crucial to estimate the size and shape of the hot spot in advance and to establish a sampling plan considering a diversity of scenarios.

Signal analysis of surface discharge and electromagnetic wave for insulator by kaolin contamination (카올린으로 오손된 애자의 표면방전 및 방사전자파의 신호 분석)

  • Park, Jae-Jun
    • The Journal of Information Technology
    • /
    • v.7 no.3
    • /
    • pp.113-118
    • /
    • 2004
  • Recently, diagnosis techniques have been investigated to detect a partial discharge associated with a dielectric material defect in a high voltage electrical apparatus. However, the properties of detection technique of PD aren't completely understood because the physical process of PD. Therefore, this paper analyzes the process on Surface Discharge of Polymer Insulator using Wavelet transform. Wavelet transform provides a direct quantitative measure of spectral content in the time frequency domain. As it is important to develop a non-contact method for detecting the Contamination Degree, this research analyzes the electromagnetic waves emitted from PD using Wavelet transform. This result experimentally shows the process of PD as a two-dimensional distribution in the time-frequency domain. The method is shown to be useful for detecting prediction of contamination degree.

  • PDF

Studies on the Contamination Degree of Effluent from the Sewage Purification System and Septic Tank (오수정화시설 및 정화조 방류수의 수질오염도에 관한 연구)

  • 어수미;이홍근
    • Journal of Environmental Health Sciences
    • /
    • v.17 no.2
    • /
    • pp.35-40
    • /
    • 1991
  • This study was performed to investigate the contamination degree of effluent from the sewage purification system and septic tank. The 711 samples, were collected from the large size tank located in Seoul from Mar. to June 1991. The results were as follows 1. The pH values of effluent were largely neutral of 6.96 in sewage and 7.43 in septic tank. 2. The average concentration of BOD was 48.18 mg/l in sewage and 127.0 rng/l in septic tank. 3. The average concentration of SS was 40.8mg/l in sewage and 90.5rng/l in septic tank. 4. In the analysis of nutrient salts, the average concentration of NH$_{3}$-N was 31.62mg/l in sewage and 88.79 mg/l in septic tank. 5. In the analysis of correlation among items, BOD, SS, NH$_{3}$-N and PO$_{4}$-P were higly correlated beween items. 6. As a results of above analysis, it is considered as desirable evaluation method of effluent not through the only item but through the integrated items.

  • PDF

Consideration of Radioactive Contamination Materials Disposal (방사성오염물질 처분에 대한 고찰)

  • Im, Hyun-Jin;Kim, Tae-Yeob;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.128-132
    • /
    • 2010
  • Purpose: Nuclear medicine general operation room is radioactive control room which is used for the handling of radioisotope(R.I). Radioactive contamination materials must be under control and separated from general trash. With this experiments, we want to actively suggest the guideline of controling and operating radioactive contamination materials by measuring contamination degree and analyzing the causes which is not realized so far. Materials and Methods: Materials are selected from Oct. 2009 to March. 2010. salines which are used for labelling radiophamaceuticals and generator cap, saline needle cap, $^{99m}Tc$-needle cap saline vial which is generated from $^{99}Mo$/$^{99m}Tc$ generator. After measuring each surface contamination degree by survey meter, mean value and standard deviation one were solved out. Results: In result, After measuring surface contamination degree, radioactivity of saline for labelling radiophamaceuticals showed $14429{\pm}26378$ cpm (p<0.05) and in measured generators, foreign imported things showed that generator cap : $9{\pm}21$ cpm, saline vial : $17{\pm}28$ cpm. saline needle cap : $35{\pm}66$ cpm, $^{99m}Tc$-needle cap : $9{\pm}21$ cpm, saline vial $13{\pm}28$ cpm. domestic things showed that generator cap : $22852{\pm}52545$ cpm, saline needle cap : $87367{\pm}109711$ cpm, $^{99m}Tc$-needle cap : $9008{\pm}10459$ cpm, saline vial : $186416{\pm}158196$ cpm (p<0.05). Conclusion: The saline which is used for labelling, exceeded 1/10 of maximum permissible range. this is generated from radiophamaceuticals dilution procedure. and In generators, radioactive value of foreign import things showed closely background value. but which of domestic thing showed that exceeded more than 1000 values 1/10 of maximum permissible range. the causes of that is domestic generator is contaminated in manufacturing procedure. So, to dispose radioactive contamination materials which is could betaken out of, the control and operation must be radical under controlled by radioactive measuring, recording and equipping of its own. if this is kept well, we can prevent surely that radioactive waste could be disposed like as general trash.

  • PDF

A Study on Bacterial Contamination of Ice Tea Sold on the Street in Seoul Area (路上販賣冷茶의 세균오염에 관한 조사연구)

  • Jang, Jae Seon
    • Journal of Environmental Health Sciences
    • /
    • v.12 no.2
    • /
    • pp.39-48
    • /
    • 1986
  • This study was carried out to investigate the bacterial contamination of Ice Tea sold on the l street in Seoul area. For this, study 81 samples were collected on the street from July to September, 1985 and were examined on the following items. 1. Degree of bacterial contamination. 2. The relation of the occurrence of fecal coliform and salmonella. 3. The change of bacterial contamination in Ice Tea against temperature. As the results of this study, the following conclusion were obtained. 1. The mean count of total viable bacteria by standard plate count was $6.5{\times}10^3$/ml, the mean count of total coliform and fecal coliform by MPN method were $3.4{\times}10^2$/100ml, 5.5/100ml and those of fecal streptococci was $3.2{\times}10^2$/100ml. 2. The mean count of Staphylococcus aureus was 10.5/ml, the isolated rate of salmonella was 7.41%. 3. In relation to the occurrence of fecal colfform and salmonella, salmonella isolated that for values above $10^2$ fecal coliform 100ml. 4. In the change of bacterial contamination in Ice Tea against temperature, the number of total coliform and fecal coliform increased at $25{\circ}$C, decreased at $4{\circ}$C, but fecal streptococci increased at $25{\circ}$C and $4{\circ}$C.

  • PDF

Geotechnical Characteristics of Crude Oil-Contaminated Sands (원유(Crude-Oil)로 오염된 사질토외 공학적 특성)

  • Eun Chul Shin;Seung Seo Hong
    • Journal of Korea Soil Environment Society
    • /
    • v.2 no.1
    • /
    • pp.91-97
    • /
    • 1997
  • The result of an investigation conducted to study the effect of crude oil contamination on the geotechnical properties of sand is presented. The effect of the degree of oil contamination on compaction charateristics, shear strength, and one-dimensional compression charateristics has been investigated. The test results indicate that the compaction charateristics are somewhat influenced by oil contamination The angle friction of sand (based on total stress basis) decreases due to the presence of oil within the pore spaces in sand. The compression charateristics of sand are significantly influenced by oil contamination. The details of the tests conducted and the results are presented in the paper.

  • PDF

Influence of Different Methods of Cutting Ampules on Drug Contamination by Glass Flakes from the Ampule (유리앰플 주사제 개봉방법이 유리조각 혼입 및 약물오염에 미치는 영향)

  • Jeong, Hyeon-Cheol;Jeon, Mi-Yang
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.16 no.2
    • /
    • pp.207-213
    • /
    • 2009
  • Purpose: This study was done to examine how medication contamination in a single-dose glass ampule is affected by minute glass flakes generated in different methods of cutting the ampule. Method: Sixty medication-containing glass ampules were randomly assigned to two groups. The number of glass flakes, resulting from two different cutting methods (with cotton and without cotton), were counted under the microscope. Contamination was evaluated by extracted the medication with a syringe and culturing it in E. coli, coliform, and aerobic bacteria culture media. Result: Fewer glass flakes were found in the ampules when the ampule was cut with cotton. The use of cotton, however, did not significantly change the degree of drug contamination. Conclusion: Although minute glass flakes generated in the ampule cutting operation did not significantly contaminate the medication and the use of cotton decreased the number of glass flakes in the ampules, glass flakes injected into the blood and tissues of the patient remain a risk factor. Therefore, pre-filled syringes or syringes with filters would be alternative methods and safeguards against the possible injection of glass flakes generated while cutting the ampule.

  • PDF

Geophysical Applications on the Soil-contamination Mapping and Detection of Buried Mine Tailings in the Abandoned Mine Area (폐광산의 토양오염영역 및 폐기된 광미의 탐지)

  • Lee, Sang Kyu;Hwang, Se Ho;Lee, Tai Sup
    • Economic and Environmental Geology
    • /
    • v.30 no.4
    • /
    • pp.371-377
    • /
    • 1997
  • This paper presents the geophysical applications to the environmenml problem in an abandoned mine area. We would like to focus our attention on the mapping of the soil contamination and the detection of the buried mine tailings. For mapping the soil contamination. measurements of both in-situ magnetic susceptibility (k) and terrain conductivity were carried out. In-situ magnetic susceptibilities of the contaminated soil due to the acid mine drainage show higher values than those of the uncontaminated area. However. those data do not show the correlation with the degree of the soil contamination observed on the surface. The least-squares fitted formula obtained with the measured insitu magnetic susceptibilities is $k=4.8207{\times}W^{0.6332}$, where W is the $Fe^{+2}$ weight percentage. This weight gives most effect to magnetic susceptibility of the soil. Lateral variations of the soil contamination in the shallow subsurface can be detected by the electrical conductivity distributions from EM induction survey. TDIP (Time Domain Induced Polarization) and EM induction surveys were conducted to detect the buried mine tailings. From the results of TDIP, the spatial zone, which shows high chargeability-low resistivity, is interpreted as the buried mine tailings. Therefore, it is concluded that it is possible to discriminate the spatial zone from the uncontaminated ground.

  • PDF

Study on the Drinking Water Index with Minerals and Anions (식수의 수질중 미네랄성분과 음이온을 이용한 지수에 관한 연구)

  • 김형석;신현덕;이기태
    • Journal of environmental and Sanitary engineering
    • /
    • v.8 no.2
    • /
    • pp.99-108
    • /
    • 1993
  • It is well known that we should take 2L of drinking water per day to maintain our health. The drinking water quality is becoming worse owing to sewage discharge and industrial wastewater. Surface water is polluted by various kinds of contaminants and ground water were known as clean and unpolluted water, but through recent many reports the ground waters are also contaminated by waste disposal and intrusion of organic and bacterial movement. This research was undertaken to make a water index of water contamination by referringcations cations and anions. NH$_{4}$, Fe, Mn, and Pb are chosen as cations and $NO_3$, Cl, and $SO_4$ ions are chosen as anions to make a index, and the following water index was made as the contamination index. (Fe+Mn+Pb)/0.7+$(NH_4+NO_3+Cl+SO_4)$/10.5<6.0 By using ton Chromatography the cations and anions are rapidly analyzed and plotting the analyzed data to the equation, we can easily get the degree of contaminations by avoiding analysis of over 37 water parameters in several days. Of course this index of water contamination is not perfect and detail one, but in case of emergent case or to know the overall trends of contamination, it is convenient to use this index. Among the tested 5 kinds of samples the ground water showed contamination index of 6.87. Authors used the already published healthy index and tasty index and differentiated their degrees in detail.

  • PDF