• 제목/요약/키워드: degree of contamination

검색결과 338건 처리시간 0.024초

Hydrogeochemistry of groundwaters in Boeun Area, Korea

  • Park, Seong-Sook;Yun, Seong-Taek;Kim, Kyoung-Ho;Kweon, Jang-Soon;Sung, Ig-Hwan;Lee, Byeong-Dae
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.519-519
    • /
    • 2003
  • We performed a hydrochemical study on a total of 89 bedrock groundwaters collected from preexisting wells (30 to 300 m deep) in the Boeun area. Hydrochemical data showed significant variations in the area, due to varying degrees of anthropogenic pollution. The waters were mostly enriched in Ca and HCO$_3$ but locally contained significant concentrations of anthropogenic constituents in the general order of Cl >NO$_3$>SO$_4$. In particular, about 11% of the examined wells exceeded the drinking water standard with respect to nitrate. We consider that aquifers in the area are locally highly susceptible to the contamination related to agricultural activities. Diagrams showing the relationships between the summation of cations (∑cations) and the concentration of several anions with different origin (natural versus anthropogenic) were used to estimate the relative role of anthropogenic contamination. A good correlation was observed for the relationship between ∑cations and bicarbonate, indicating that water-rock interaction (namely, hydrolysis of silicate minerals) is most important to control the water quality. Thus, we made an assumption that the equivalent of dissolved cations for a water should be equal to the alkalinity, if the chemistry were controlled solely by a set of natural weathering reactions. If we excluded the equivalent quantities of cations and bicarbonate (natural origin) from the acquired data for each sample, the remainder therefore could be considered to reflect the degree of anthropogenic contamination. Finally, we performed a multiple regression approach for hydrochemical data using the ∑cations as a dependent variable and the concentration data of each anion (natural or anthropogenic) as an independent variable. Using this approach, we could estimate the relative roles of anthropogenic and natural processes. Rather than the conventional evaluation scheme based on water quality criteria, this approach will be more useful and reasonable for the evaluation of groundwater quality in a specific region and also can be used for planning appropriate protection and remedial actions.

  • PDF

A study on the effects of an artificial oil-spill on the ultrastructural changes in the digestive glands of Crassostrea gigas (태안반도 기름 유출사고 이후 인근해안에 서식하는 굴(Crassostrea gigas) 간췌장 (digestive gland) 의 미세구조 변화에 관한 연구)

  • Jun, Je-Cheon;Kang, Se-Won;Baek, Moon-Ki;Jeong, Ji-Eun;Shin, Yun-Kyung;Park, Young-Je;Han, Yeon-Soo;Lee, Yong-Seok
    • The Korean Journal of Malacology
    • /
    • 제27권1호
    • /
    • pp.77-86
    • /
    • 2011
  • The unwanted artificial oil-spill has severely contaminated the coastal environment in the world. Level of contamination has so far been monitered by various indicator species including mussel, oysters, flounder, and cockle. In this study, we decided to use the oyster as a model organism to observe the morphological changes being exposed to the artificial oil-spill in the coastal areas in Taean, Korea. The oysters were collected from four local sites (Sindu-ri, Uiwang-ri, Jonghyeon-dong, Ansan and Uihang-ri) exposed to various levels of pollution after an oil spill in Taean. Microscopic analysis of the hepatopancreatic microstructure in the digestive gland from the collected oysters show that the swelling, whorl, and destruction phenomenon of the nuclear membrane, a well-known microstructure induced by heavy metal exposure, was observed. Nuclear body (Nb), another typical characteristic of contamination or infection were also observed in some samples. Necrosis was observed in tissue samples collected from the area with a high degree of oil pollution. In addition, parasite-like particles (virus, perkinsus) were observed in most samples. Taken together, these results suggest that oil contamination in the oyster habitats influences the cytopathological changes in Crassostrea gigas.

Determination of Phthalates Compounds in the Ambient Atmosphere (II) - Evaluation of Experimental Artifacts and Sample Clean-up Procedures - (환경대기 중 프탈레이트 화합물의 농도 측정 (II) - 실험재료 전처리 및 시료정제과정 평가 -)

  • Park, Young-Hwa;Hwang, Yoon-Jung;Seo, Young-Kyo;Baek, Sung-Ok
    • Journal of Korean Society of Environmental Engineers
    • /
    • 제32권5호
    • /
    • pp.455-460
    • /
    • 2010
  • This study was carried out to find out any inherent problems occurring in the sampling and analytical procedures, and to suggest the relevant solutions to the problems. In addition, an optimal condition of clean-up process was developed, which was based on a method using silica glass column. As a result of experiments to test any artificial contamination of blank samples such as glassware and collection media, artifacts of DBP and DEHP appeared to be detected in various kinds of laboratory tools and apparatuses used in the sampling and analytical works. Therefore, it is necessary to investigate a degree of contamination before laboratory works by conducting a prior check any possible contaminations in all experimental tools and apparatus. It is also necessary to devise a method to avoid a tool, if possible, or to use a substitute of phthalate free. If the use of any plastic tool to cause contamination is inevitable, it should be properly corrected with a blank level, as is equally treated as the sample. The clean-up process demonstrated in this study can give us a significant benefit in terms of the quantity and quality of a target compound by GC/MS analysis.

Bacteriological Research for the Contamination of Equipment in Chest Radiography (영상의학과 흉부 엑스선 촬영 기기의 세균 오염도)

  • Choi, Seung Gu;Song, Woon Heung;Kweon, Dae Cheol
    • Journal of radiological science and technology
    • /
    • 제38권4호
    • /
    • pp.395-401
    • /
    • 2015
  • The purpose is to determine the degree of contamination of the equipment for infection control in chest radiography of the radiology department. We confirmed by chemical and bacterial identification of bacteria of the equipment and established a preventive maintenance plan. Chest X-ray radiography contact area on the instrument patients shoulder, hand, chin, chest lateral radiography patient contact areas with a 70% isopropyl alcohol cotton swab were compared to identify the bacteria before and after sterilization on the patient contact area in the chest radiography equipment of the department. The gram positive Staphylococcus was isolated from side shoots handle before disinfection in the chest radiography equipment. For the final identification of antibiotic tested that it was determined by performing the nobobiocin to the sensitive Staphylococcus epidermidis. Chest radiography equipment before disinfecting the handle side of Staphylococcus epidermidis bacteria were detected using a disinfectant should be to prevent hospital infections.

The Association of Health Care Workers' Uniforms and Health Care-associated Infection: Systematic Review (병원근무자 유니폼에 의한 병원 내 감염에 대한 체계적 문헌고찰)

  • Jeong, Eun-Young;Kim, Jin-Hyun
    • Perspectives in Nursing Science
    • /
    • 제10권1호
    • /
    • pp.65-76
    • /
    • 2013
  • Purpose: To identify an associations between health care workers' uniforms and health care-associated infection. Methods: Electronic databases, including Ovid-Medline, the Cochrane Library, CINAHL, EMBASE, KMbase, and KoreaMed, were searched. The search terms included doctor, nurse, health care worker/staff/assistant, clothing, (white) gown, uniform, (neck)tie, and attire. Only papers published in English and Korean were included. Results: 16 studies were selected from 1,900 references screened. All of the studies were non-comparative studies except for one. Four were conducted with doctors, six with nurses, one with health care workers including physiotherapists and one for medical staff plus visitors in a neonatal intensive care unit. Doctors more frequently changed their uniforms than neckties; therefore, the degree of contamination was more serious in neckties. The cuff zone was more likely to be heavily contaminated than other areas of long-sleeve gowns. Coats become contaminated quickly once worn, and colony counts reached a similar level within the first few hours after wearing them. Wearing a plastic apron or protective clothing did not prevent the bacterial contamination of nurses' uniforms, and the best way to decrease the contamination was changing to newly laundered uniforms before starting every duty. Conclusion: Healthcare workers' uniforms are a potential source of health care-associated infection although there was no robust evidence. The government must establish standards for laundering of uniforms or a requirement for institutions to provide a laundering service for healthcare workers' uniforms.

  • PDF

Analysis of Trends in Dose through Evaluation of Spatial Dose Rate and Surface Contamination in Radiation-Controlled Area and Personal Exposed Dose of Radiation Worker at the Korea Institute of Radiological and Medical Sciences (KIRAMS)

  • Lee, Bu Hyung;Kim, Sung Ho;Kwon, Soo Il;Kim, Jae Seok;Kim, Gi-sub;Park, Min Seok;Park, Seungwoo;Jung, Haijo
    • Progress in Medical Physics
    • /
    • 제27권3호
    • /
    • pp.146-155
    • /
    • 2016
  • As the probability of exposure to radiation increases due to an increase in the use of radioisotopes and radiation generators, the importance of a radiation safety management field is being highlighted. We intend to help radiation workers with exposure management by identifying the degree of radiation exposure and contamination to determine an efficient method of radiation safety management. The personal exposure doses of the radiation workers at the Korea Institute of Radiological & Medical Sciences measured every quarter during a five-year period from Jan. 1, 2011 till Dec. 31, 2015 were analyzed using a TLD (thermoluminescence dosimeter). The spatial dose rates of radiation-controlled areas were measured using a portable radioscope, and the level of surface contamination was measured at weekly intervals using a piece of smear paper and a low background alpha/beta counter. Though the averages of the depth doses and the surface doses in 2012 increased from those in 2011 by about 14%, the averages were shown to have decreased every year after that. The exposure dose of 27 mSv in 2012 increased from that in 2011 in radiopharmaceutical laboratories and, in the case of the spatial dose rate, the rate of decrease in 2012 was shown to be similar to the annual trend of the whole institute. In the case of the surface contamination level, as the remaining radiation-controlled area with the exception of the I-131 treatment ward showed a low value less than $1.0kBq/m^2$, the annual trend of the I-131 treatment ward was shown to be similar to that of the entire institute. In conclusion, continuous attention should be paid to dose monitoring of the radiation-controlled areas where unsealed sources are handled and the workers therein.

Establishment of in Vitro Culture and Effect of Chilling Treatment of Mother Bulb On Bulblet Formation in Fritillaria thunbergii Miq. (패모의 초기배양과 모구의 저온처리가 자구형성에 미치는 영향)

  • Yu, Kwang-Jin;Paek, Kee-Yeoup;Seong, Nak-Sul;Choi, In-Sick;Cho, Jin-Tae
    • Korean Journal of Medicinal Crop Science
    • /
    • 제2권3호
    • /
    • pp.211-218
    • /
    • 1994
  • This experiment was conducted to obtain basic information for the establishment of in vitro initial culture system in Fritillaria thuubergii Miq. Methods of surface sterilization of scale segments as explant and effect of antibiotics added into the culture medium on contamination of explant and chilling treatment of mother bulb on bulblet formation were investigated. Portent of contamination of cultured scale segments was significantly higher in the outer scale segments which were unsuitable as initial culture explant than inner scale segments. Contamination of explants taken from inner scale of bulb was reduced by surface sterilizing explants in the solution of $4{\sim}5%$ sodium hypoclorite for $10{\sim}15$ mimutes. Addition of antibiotics such as kanamycin, vancomycia cefotaxim, agrirnycin and agreptomycin and dithane as fungicide and$lncyte^{tm}$ into MS medium was effective to reduce bateriological contamination, but did not work to control fungi. It had effective to delay the degree of contamination caused by fungi and bacteria haboring in cultured explants. Bulblet formation from cultured scale segments was promoted by dry storage for $2{\sim}4$ weeks or moisture storage of mother bulbs for $4{\sim}6$ weeks at $10^{\circ}C$ before excision of explants. Addition of kinetin into medium could not exerted for the bulblet formation from the scale segment of dry storaged bulb compared to control. But explant taken from 6 week moisture storaged bulb formed more than 10 bulblets per explant on the medium containing $3{\sim}5mg/L$ kinetin.

  • PDF

A Convergence Study on the Contamination and Disinfection of General X-ray generator Practical Equipment (일반촬영 실습 장비의 오염 및 소독에 관한 융합적 연구)

  • Park, Gyu-Tae;Kim, Dong-Heun;Park, Sang-Hee;Jung, Won-Hee;Kim, So-Yeon;Hong, Hee-Jin;Son, Na-Ra;Nam, Seoul-Hee;Han, Man-Seok
    • Journal of the Korea Convergence Society
    • /
    • 제11권1호
    • /
    • pp.51-56
    • /
    • 2020
  • It is going to select one X-ray generating device for diagnosis in a radiography laboratory at K university in Gangwon-do to detect bacteria on the surface contamination of tables, IP cassettes, and lead gowns for medical radiation shielding and to inform students of the need for proper disinfection control and hand hygiene. Then disinfection was carried out with tissue, tissue cleaner and 70% alchol and immediately collected with sterile cotton swabs to assess the contamination distribution status and disinfection effects of the surface. The results of measuring the degree of contamination on the surface showed that the largest number of bacteria were detected in Apron, and the evaluation of the disinfection effects according to surface contamination showed a noticeable effect at 70% Alcohol in IP Cassette, and the disinfection effect was the same for Apron. Therefore, in order to prevent bacterial infections among students, basic hand washing and regular disinfection should be performed before the practice to prevent infection.

Microorganism Contamination from Wearing One-Day Disposable Contact Lenses According to Wearing Time (일일 착용 콘택트렌즈의 연속 착용에 따른 세균 오염)

  • Choi, Gang-Won;Jang, Woo-Yeong;Lee, Jong-Wook;Kim, Su-Jung
    • Korean Journal of Microbiology
    • /
    • 제46권2호
    • /
    • pp.152-156
    • /
    • 2010
  • Disposable contact lenses, which are one type of soft contact lenses, provide convenience in use, but also cause various ocular infectious diseases. Microorganisms that cause eye diseases include Acanthamoeba, bacteria, Fungi, and so on. It is impossible to prevent microorganism contamination completely due to the use of hands as wearing contact lenses. The contamination by various microorganisms leads to infectious keratitis, but it is not well known for the exact microorganisms that affect the disease. For this reason, to identify the microorganisms, two groups that are commonly used for disinfection of lenses were divided: normal saline solution and multiple purpose solution. Using these solutions the degree of microorganism contamination was observed according to the days of 1, 3, 5, 10, and 15. Twenty students by two groups from Ophthalmic Optics department at D college in Daegu Metropolitan city participated in the experiment after their ocular health conditions were checked. During they wore one-day disposable lenses for 1, 3, 5, 10, and 15 days, bacteria were cultured in media. The results, which were Gram stained by selecting the cultured colonies, show as followings: Gram positive cocci 33%, Gram-negative cocci 2%, Gram positive bacilli 34%, and the Gram negative bacilli 31%, respectively. As for the identification of potential pathogens, VITEK system and API kit methods were used. Keratitis caused by bacteria known as Staphylococcus aureus, Pseudomonas aeruginosa were detected as a result of wearing contact lenses. This study examined the distribution of bacteria as wearing one-day disposable contact lenses and pathogenic bacteria according to the duration of wearing them. In conclusion, the importance of hygiene when using contact lenses is suggested.

A Model for Evaluating the Radioactive Contamination in the Urban Environment (도시환경에서 방사성물질의 오염평가 모델개발)

  • Hwang, Won-Tae;Kim, Eun-Han;Jeong, Hyo-Joon;Suh, Kyung-Suk;Han, Moon-Hee
    • Journal of Radiation Protection and Research
    • /
    • 제30권3호
    • /
    • pp.99-105
    • /
    • 2005
  • A model for evaluating radioactive contamination in the urban environment, named METRO-K, was developed as a basic step for accident consequence analysis in case of an accidental release. The three kind of radionuclides $(^{137}Cs,\;^{106}Ru,\;^{131}I)$ and the different chemical forms of iodine (particulate, organic and elemental forms) are considered in the model. The radioactive concentrations are evaluated for the five types of surface (roof, paved road, wall, lawn/soil, tree) as a function of time. Using the model, the contaminative impacts of the surfaces were intensively investigated with respect to with and without precipitation during the measurement periods of radionuclides in air. In addition, a practical application study was conducted using $^{137}Cs$ concentration in air and precipitation measured in an European country at the Chernobyl accident. As a result precipitation was an influential factor in surface contamination. The degree of contamination was strongly dependent on the types of radionuclide and surface. Precipitation was more influential in contamination of $^{137}Cs$ than that of $^{131}I$ (elemental form).