Bacteriological Research for the Contamination of Equipment in Chest Radiography

영상의학과 흉부 엑스선 촬영 기기의 세균 오염도

  • Choi, Seung Gu (Department of Clinical Laboratory Science, Shinhan University) ;
  • Song, Woon Heung (Department of Clinical Laboratory Science, Shinhan University) ;
  • Kweon, Dae Cheol (Department of Radiological Science, Shinhan University)
  • 최승구 (신한대학교 임상병리학과) ;
  • 송운흥 (신한대학교 임상병리학과) ;
  • 권대철 (신한대학교 방사선학과)
  • Received : 2015.10.23
  • Accepted : 2015.12.07
  • Published : 2015.12.31

Abstract

The purpose is to determine the degree of contamination of the equipment for infection control in chest radiography of the radiology department. We confirmed by chemical and bacterial identification of bacteria of the equipment and established a preventive maintenance plan. Chest X-ray radiography contact area on the instrument patients shoulder, hand, chin, chest lateral radiography patient contact areas with a 70% isopropyl alcohol cotton swab were compared to identify the bacteria before and after sterilization on the patient contact area in the chest radiography equipment of the department. The gram positive Staphylococcus was isolated from side shoots handle before disinfection in the chest radiography equipment. For the final identification of antibiotic tested that it was determined by performing the nobobiocin to the sensitive Staphylococcus epidermidis. Chest radiography equipment before disinfecting the handle side of Staphylococcus epidermidis bacteria were detected using a disinfectant should be to prevent hospital infections.

영상의학과의 흉부엑스선 검사에서 감염관리에 대한 기기의 오염 정도를 세균학적으로 확인하고 균을 동정하여 병원감염의 예방과 감염관리방안을 마련하는데 목적이 있다. 영상의학과 흉부 엑스선 검사에서 환자의 기기 접촉부위인 어깨, 손, 턱, 흉부 측면촬영의 손잡이 부위를 70% 이소프로필 알코올로 소독하기 전과 후를 면봉으로 검체를 채취하여 세균을 동정하여 비교하여 분석하였다. 흉부 엑스선 기기에서 소독전의 측면촬영의 손잡이에서 그람 양성의 Staphylococcus가 분리되었다. 최종동정을 위해 노보바이오신 (nobobiocin) 항생제 시험을 실시하여 민감성으로 Staphylococcus epidermidis로 확정하였다. 흉부촬영 기기에서 측면촬영의 손잡이 부위를 소독 전에 Staphylococcus epidermidis 균이 검출되었다. 흉부엑스선 검사에서 기기를 주기적인 소독 및 멸균을 실시하여 병원감염을 예방하는 관리방안을 마련하여야 한다.

Keywords

References

  1. Kim GP: Radiation exposure of Korean population from medical diagnostic examinations, Ministry of Food and Drug Safety. 2013
  2. Wouter JH, Veldkamp, Lucia JM: Dose and perceived image quality in chest radiography, European J Radiol,72(2), 209-217, 2009 https://doi.org/10.1016/j.ejrad.2009.05.039
  3. Kim SC: Bacteriological monitoring of radiology room apparatus in the department of radiological technology and contamination on hands of radiological technologists, J Radiol Sci Technol, 31(4), 329-335, 2008
  4. Lee JS, Jeong KH, Kim GH, Im IC, Kweon DC, Goo EH, Dong KR, Chung WK: Radiology department infection control according to radiography frequency and disinfection period, J Korean Soc Radiol, 5(2), 73-80, 2011 https://doi.org/10.7742/jksr.2011.5.2.073
  5. Bae SH, Lee MS, Lim CS, Kim GJ: A study on the measurement of the pollution level of bacteria and disinfection of table and IP cassette, J Radiol Sci Technol, 31,229-237, 2008
  6. Fox M, Harvey JM: An investigation of infection control for X-ray cassettes in a diagnostic imaging department, Radiography, 14(4), 306-311, 2008 https://doi.org/10.1016/j.radi.2007.09.004
  7. Manual of Clinical Microbiology, 11th edition, ASM Press, Washington DC, USA, 2015
  8. Swain, JA, Flinton DM: X-ray cassettes a potential cross-infection risk. J Diagn Radiogr Imaging, 3, 121-125, 2003
  9. Kim JS, Kim HS, Park JY, Koo HS, Choi CS, Song W, Cho HC, Lee KM: Contamination of X-ray cassettes with methicillin-resistant staphylococcus aureus and methicillin-resistant staphylococcus haemolyticus in a radiology department, Ann Lab Med, 32, 206-209, 2012 https://doi.org/10.3343/alm.2012.32.3.206
  10. Levin PD, Shatz O, Sviri S, Moriah D, Or-Barbash A, Sprung CL, Moses AE, Block C: Contamination of portable radiograph equipment with resistant bacteria in the ICU, Chest, 136(2), 426-432, 2009 https://doi.org/10.1378/chest.09-0049
  11. Sugarman B, Young EJ, Infections associated with prosthetic devices: magnitude of the problem. Infect Dis Clin North Am, 3, 187-198, 1989
  12. Kim KJ, Shin JH, Shin DH, Choi MJ, Cho D, Kee SJ, Suh SP, Ryang DW: Prevalence of pathogens causing centralvenous catheter CCV9-related sepsis: results of semiquantitative CVC tip cultures and differential quantitative blood cultures, Korean J Lab Med, 22, 260-266, 2002
  13. Kim JH, Eun HS, Choi KM, Kim DS, Young DE: Epidemiology of central venous catheter related blood stream infections in pediatric patients, Korean J Pediatr, 49, 157-161, 2006 https://doi.org/10.3345/kjp.2006.49.2.157
  14. Kweon DC, Kim MS, Kim DS, Park P: A Survey of the radiographic cassettes disinfection of university hospitals in Seoul, J Radiol Sci Technol, 24,65-70, 2001
  15. Kweon DC, Park P: Disinfection effect of film cassettes by ultraviolet irradiation, J Radiat Prot Res, 26(4), 425-432, 2001
  16. Kim JH, Kang SS, Kim CS: Analysis of hospital control awareness of ultrasound room office personal in Busan, , J Radiol Sci Technol, 38, 135-143, 2015 https://doi.org/10.17946/JRST.2015.38.2.08
  17. Dong KR, Ro SH, Kweon DC, Ryu YH, Dong CB, Yu EY, Cho YK: A study regarding measurements of bacterial contamination levels in radiology room within the department of radiological technology, J Odor Indoor Environ, 6(4), 275-284, 2009
  18. Park ES, Jeong JS, Kim KM, Kim OS, Jeong SY, Jang SY, Yoon SW, Descriptive study on the current usage of disinfectants in Korea, Korean J Nosocomial Infect Control, 11, 42-49, 2006.
  19. Park JH, Yoon HS: A study of hospital infection in the postoperative patients, J Korean Acad Nurs, 16(2), 70-76, 1986