• Title/Summary/Keyword: defective effects

Search Result 104, Processing Time 0.028 seconds

Four Cases of Stroke Patients with Defective Vision Treated with Venesection on Palpebral Conjunctiva (眼瞼結膜 刺絡療法(棘鍼療法)을 시술한 中風 환자의 眼昏 치험 4例)

  • Ock, Min-keun;Lim, Woong-kyoung;Yoon, Hyoung-seon;Sun, Young-jae;Moon, Jang-hyuk;Kim, Chang-hwan
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.17 no.3
    • /
    • pp.107-113
    • /
    • 2004
  • Objective: This study was performed to evaluate the effects of venesection on palpebral conjunctiva, on the stoke patients complaint of defective vision. Methods: We studied four selected stroke patients with defective vision which start with stroke. Venesection was performed with syringe needleonce or several times on upper or lower palpebral conjunctiva. After every venesection we washed the eye(s) with normal saline. We evaluated the effects by VAS. Results & conclusion: Venesection on palpebral conjunctiva was efficacious against defective vision occured on the stoke patients. But more clinical & scienific trials are expected to follow this study.

  • PDF

Defective Medicine according to Product Liability Law (제조물책임법상 제조물로서 의약품의 결함)

  • Jeon, Byong-Nam
    • The Korean Society of Law and Medicine
    • /
    • v.8 no.1
    • /
    • pp.235-277
    • /
    • 2007
  • In Product Liability law, the 'defection' of the manufactured products is its key concept, defined in detail. The concept had been already developed through the precedents and theories for the past years even before the PL law was enacted and the concept was listed. Especially, the medicine products need the different approach, because they might directly harm to the human life and body due to their being injected or taken, unlikely other manufactured articles. Since the medical products have the double contradictory functions such as effects and side effects, the defection decisions become so difficult. However, because there are high concerns that wrong medical products will directly harm the human life and body, the decision standards should be more strengthened. The decision standards should include the risk-effect standard as the considered components and make the customer-expecting standard as the final standard. The decision time for defection should be made considering the science technology level when the medical products were provided, not when the accident occurred. It is the most important for the manufacturers to prevent the damages by making and selling the non-defective medicine products for themselves, rather than by taking the legal remedy means afterwards. Therefore, the non-defective guidelines for the medicine manufacturers will help increase the effects and minimize the side-effects.

  • PDF

An Analysis for Expected Effect of the Introduction of Motorcycle Safety Inspection (이륜자동차 안전검사제도 도입 시 기대효과 분석)

  • Bang, Soohyuk;Lee, Jisun
    • International Journal of Highway Engineering
    • /
    • v.15 no.5
    • /
    • pp.157-166
    • /
    • 2013
  • PURPOSES : This study is to analyze expected effect of a accident decrease when motorcycle safety inspection is introduced. METHODS : Based on the literature review of effect of 4-wheel vehicle inspection, probability of occurring accidents among defective motorcycles are calculated by using the number of estimated defective motorcycles and accidents resulting from defects of motorcycles. Then, the number of decreased accidents which is resulting from eliminating defects of motorcycles by safety inspection is estimated by using probability of occurring accidents among defective motorcycles. RESULTS : If the ratio of eliminating defects of motorcycles is 95% after motorcycle safety inspection, the effects of accident decrease of motorcycle safety inspection are analyzed from 2005 to 2008. As a result, 46,292 defective motorcycles are repaired and 1,376 accidents are prevented when the probability of occurring accidents among defective motorcycles is 2.97%. CONCLUSIONS : This study suggests the expected effect of motorcycle safety inspection is that the inspection can prevent 1,376 motorcycle accidents. However, the number of preventing motorcycle accidents are small, compared with the total number of motorcycle accidents because there are limitations to investigate the causes of defective motorcycle accidents. A more precise analysis of the expected effect of motorcycle inspection is possible when a systematic investigation of the causes of the accidents is implemented.

Nuclear Localization Signals in Prototype Foamy Viral Integrase for Successive Infection and Replication in Dividing Cells

  • Hossain, Md. Alamgir;Ali, Md. Khadem;Shin, Cha-Gyun
    • Molecules and Cells
    • /
    • v.37 no.2
    • /
    • pp.140-148
    • /
    • 2014
  • We identified four basic amino acid residues as nuclear localization signals (NLS) in the C-terminal domain of the prototype foamy viral (PFV) integrase (IN) protein that were essential for viral replication. We constructed seven point mutants in the C-terminal domain by changing the lysine and arginine at residues 305, 308, 313, 315, 318, 324, and 329 to threonine or proline, respectively, to identify residues conferring NLS activity. Our results showed that mutation of these residues had no effect on expression assembly, release of viral particles, or in vitro recombinant IN enzymatic activity. However, mutations at residues 305 (R ${\rightarrow}$ T), 313(R ${\rightarrow}$ T), 315(R ${\rightarrow}$ P), and 329(R ${\rightarrow}$ T) lead to the production of defective viral particles with loss of infectivity, whereas non-defective mutations at residues 308(R ${\rightarrow}$ T), 318(K ${\rightarrow}$ T), and 324(K ${\rightarrow}$ T) did not show any adverse effects on subsequent production or release of viral particles. Sub-cellular fractionation and immunostaining for viral protein PFV-IN and PFV-Gag localization revealed predominant cytoplasmic localization of PFV-IN in defective mutants, whereas cytoplasmic and nuclear localization of PFV-IN was observed in wild type and non-defective mutants. However sub-cellular localization of PFV-Gag resulted in predominant nuclear localization and less presence in the cytoplasm of the wild type and non-defective mutants. But defective mutants showed only nuclear localization of Gag. Therefore, we postulate that four basic arginine residues at 305, 313, 315 and 329 confer the karyoplilic properties of PFV-IN and are essential for successful viral integration and replication.

Effect of 20 % EDTA Aqueous Solution on Defective Tubes (Alloy600) in High Temperature Chemical Cleaning Environments (고온화학세정환경에서 20 % EDTA 용액이 결함 전열관 (Alloy600)에 미치는 영향)

  • Kwon, Hyuk-chul
    • Corrosion Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.84-91
    • /
    • 2016
  • The transport and deposition of corrosion products in pressurized water nuclear reactor (PWR) steam generators have led to corrosion (SCC, denting etc.) problems. Lancing, mechanical cleaning and chemical cleaning have been used to reduce these problems. The methods of lancing and mechanical cleaning have limitations in removing corrosion products due to the structure of steam generator tubes. But high temperature chemical cleaning (HTCC) with EDTA is the most effective method to remove corrosion products regardless of the structure. However, EDTA in chemical cleaning aqueous solution and chemical cleaning environments affects the integrity of materials used in steam generators. The nuclear power plants have to perform the pre-test (also called as qualification test (QT)) that confirms the effect on the integrity of materials after HTCC. This is one of the series studies that assess the effect, and this study determines the effects of 20 % EDTA aqueous solution on defective tubes in high temperature chemical cleaning environments. The depth and magnitude of defects in steam generator (SG) tubes were measured by eddy current test (ECT) signals. Surface analysis and magnitude of defects were performed by using SEM/EDS. Corrosion rate was assessed by weight loss of specimens. The ECT signals (potential and depth %) of defective tubes increased marginally. But the lengths of defects, oxides on the surface and weights of specimens did not change. The average corrosion rate of standard corrosion specimens was negligible. But the surfaces on specimens showed traces of etching. The depth of etching showed a range on the nanometer. After comprehensive evaluation of all the results, it is concluded that 20 % EDTA aqueous solution in high temperature chemical cleaning environments does not have a negative effect on defective tubes.

Advanced electromagnetic wave-based method for characterizing defects in cement-based structures using time domain reflectometry

  • Dongsoo Lee;Jong-Sub Lee;Young K. Ju;Yong-Hoon Byun
    • Computers and Concrete
    • /
    • v.33 no.5
    • /
    • pp.621-630
    • /
    • 2024
  • This study presents novel electromagnetic wave-based methods for evaluating the integrity of cement-based structures using time domain reflectometry (TDR). Two cement-based plates with embedded rebars are prepared under sound and defective conditions. TDR tests are carried out using transmission lines with various numbers of artificial joints, and electromagnetic waves are measured to assess the integrity of the plates. The experimental results show that the travel time of electromagnetic waves is consistently longer in sound plates than in defective ones, and an increase in the reflection coefficients is observed in the defect zone of the defective plates. Electromagnetic wave velocities are higher in the defective plates, especially when connectors are present in the transmission line. A novel approach based on the area of the reflection coefficient provides larger areas in the defective plates, and the attenuation effect of the electromagnetic waves induces a difference in the areas of the reflection coefficient between the two defect conditions. An alternative method using the centroid of the defect zone slightly overestimates the location of the defect zone. The length of the defect zone is estimated using the defect ratio and wave velocities of cement, air, and plate. The length of the defect zone can also be calculated using the travel times within the plate, total measured length of the plate, and wave velocities in the cement and air. Therefore, the electromagnetic wave-based methods proposed in this study may be useful for estimating the location and length of defect zones by considering attenuation effects.

The Characteristics and Implementations of Quality Metrics for Analyzing Innovation Effects in Six Sigma Projects (식스시그마 프로젝트 사례에서 혁신효과 분석을 위한 품질척도의 특성 및 적용)

  • Choi, Sungwoon
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.1
    • /
    • pp.169-176
    • /
    • 2014
  • This research discusses the characteristics and the implementation strategies for two types of quality metrics to analyze innovation effects in six sigma projects: fixed specification type and moving specification type. $Z_{st}$, $P_{pk}$ are quality metrics of fixed specification type that are influenced by predetermined specification. In contrast, the quality metrics of moving specification type such as Strictly Standardized Mean Difference(SSMD), Z-Score, F-Statistic and t-Statistic are independent from predetermined specification. $Z_{st}$ sigma level obtains defective rates of Parts Per Million(PPM) and Defects Per Million Opportunities(DPMO). However, the defective rates between different industrial sectors are incomparable due to their own technological inherence. In order to explore relative method to compare defective rates between different industrial sectors, the ratio of specification and natural tolerance called, $P_{pk}$, is used. The drawback of this $P_{pk}$ metric is that it is highly dependent on the specification. The metrics of F-Statistic and t-Statistic identify innovation effect by comparing before-and-after of accuracy and precision. These statistics are not affected by specification, but affected by type of statistical distribution models and sample size. Hence, statistical significance determined by above two statistics cannot give a same conclusion as practical significance. In conclusion, SSMD and Z-Score are the best quality metrics that are uninfluenced by fixed specification, theoretical distribution model and arbitrary sample size. Those metrics also identify the innovation effects for before-and-after of accuracy and precision. It is beneficial to use SSMD and Z-Score methods along with popular methods of $Z_{st}$ sigma level and $P_{pk}$ that are commonly employed in six sigma projects. The case studies from national six sigma contest from 2011 to 2012 are proposed and analyzed to provide the guidelines for the usage of quality metrics for quality practitioners.

Effect Analysis of Certification of ISO 9000 Quality Management System (ISO 9001:2000 품질경영시스템 인증 도입효과 분석)

  • Kwon, Bong-Gi;Kim, Ho-Gyun;Yun, Won-Young
    • Journal of Korean Society for Quality Management
    • /
    • v.34 no.2
    • /
    • pp.1-11
    • /
    • 2006
  • This paper is related to the effect analysis of certification of ISO 9000 Quality Management System. We collect and analyze the field data of certification costs and profit from companies that are located at southeast area in Korea. The effect analysis is based on the type and scale of companies. We use defective rate and inventory turnover rate as the criterion of positive effect after certification. As a result, we may conclude that the certification of ISO Quality Management System gives companies positive effects.

Effect of Simvastatin collagen graft on wound healing of defective bone (Simvastatin이 골결손부 회복에 미치는 영향)

  • Kang, Jung-Ho;Kim, Gyu-Tae;Choi, Yong-Suk;Lee, Hyeon-Woo;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.38 no.3
    • /
    • pp.133-146
    • /
    • 2008
  • Purpose : To observe and evaluate the effects of Simvastatin-induced osteogenesis on the wound healing of defective bone. Materials and Methods : 64 defective bones were created in the parietal bone of 32 New Zealand White rabbits. The defects were grafted with collagen matrix carriers mixed with Simvastatin solution in the experimental group of 16 rabbits and with collagen matrix carriers mixed with water in the controlled group. The rabbits were terminated at an interval of 3, 5, 7, and 9 days, 2, 4, 6, and 8 weeks after the formation of defective bone. The wound healing was evaluated by soft X-ray radiography. The tissues within defective bones were evaluated through the analysis of flow cytometry for the manifestation of Runx2 and Osteocalcin, and observed histopathologically by using H-E stain and Masson's trichrome stain. Results : 1. In the experimental group, flow cytometry revealed more manifestation of Runx2 at 5, 7, and 9 days and Osteocalcin at 2 weeks than in the controlled groups, but there was few difference in comparison with the controlled group. 2. In the experimental group, flow cytometry revealed considerably more cells and erythrocytes at 5, 7, and 9 days in comparison with the controlled group. 3. In the experimental group, soft x-ray radiography revealed the extended formation of trabeculation at 2, 4, 6, and 8 weeks. 4. Histopathological features of the experimental group showed more fibroblasts and newly formed vessels at 5 and 7 days, and the formation of osteoid tissues at 9 days, and the newly formed trabeculations at 4 and 6 weeks. Conclusion : As the induced osteogenesis by Simvastatin, there was few contrast of the manifestation between Runx2 and Osteocalcin based on the differentiation of osteoblasts. But it was considered that the more formation of cells and erythrocytes depending on newly formed vessels in the experimental group obviously had an effect on the bone regeneration.

  • PDF

The Evaluations of Thermal Stability and Stress Crack Resistance of Geomembranes with Surface Defects in the Landfill (폐기물매립지에서 표면결함이 있는 지오멤브레인의 열적 안정성 및 응력균열저항성 평가)

  • 전한용;이광열;이재영
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.1
    • /
    • pp.53-62
    • /
    • 2001
  • Effects of surface defect on thermal stability and stress crack resistance of high density polyethylene geomembranes in environmental conditions were examined by comparing the mechanical properties, chemical resistance and failure times of geomembranes between defective cases under different temperatures. Artificial surface defects were added to the surface of geomembranes by scratch apparatus designed specially. The number of surface defects was increased with the smaller size of scratch induced particles, and the more scratch addition numbers at the shear rate of scratch induced mechanism, 100mm/min. The tensile strength were decreased but the tensile strain was increased with the above conditions. In chemical resistance of defective geomembranes, the tensile strength were decreased but the tensile strain was increased with the longer immersion period and the higher temperature under the same scratch induced conditions. Finally, failure times of defective geomembranes by ESCR test were shifted to the shorter time ranges by increasing temperatures.

  • PDF