• Title/Summary/Keyword: decompression pump

Search Result 6, Processing Time 0.02 seconds

Evaluation of Diecasting Mold Cooling Ability by Decompression Cooling System (감압냉각장치를 이용한 다이캐스팅 금형의 냉각성능평가)

  • Kim, Eok-Soo;Park, Joo-Yul;Kim, Yong-Hyun;Son, Gi-Man;Lee, Kwang-Hak
    • Journal of Korea Foundry Society
    • /
    • v.29 no.5
    • /
    • pp.238-243
    • /
    • 2009
  • This study has been carried out to investigate the cooling ability improvement of diecasting mold by decompression cooling system. The decompression cooling system was applied to the new/used oil pump cover molds. The temperature of the surface mold applied the decompression cooling system fell to 15 degrees, especially in case of the used mold. The defect ratio of the oil pump cover manufactured by decompression cooling system has decreased from 2.8 percent to 0.2 percent. According to the results of the cooling ability improvement of diecasting mold by decompression cooling system, the decompression degree and supply pressure were set up the control item to apply the decompression cooling system to the diecasting mold in the industry field.

A Study on Effects of Piston Pumping Phase on Vibration and Noises of Tandem Swash Plate Type Axial Piston Pump(2) (피스톤 펌핑 위상이 텐덤형 사판식 액셜 피스톤 펌프의 진동, 소음에 미치는 영향에 관한 연구(2))

  • Park, Sung-Hwan;Lee, Jin-Kul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.12
    • /
    • pp.31-39
    • /
    • 1999
  • Previous researches and experiments have already verified that the primary noise source of high pressure tandem axial thpe piston pump is fluid-borne noise from the process of oil distribution between the kidney-shaped port and valve plate. So, many researchers have improved pressure gradients and reduced sound levels by applying pre-compression and pre-decompression metering grooves to valve plate. In practice however, the sound level of th high pressure tandem axial type piston pump is still undesirable. This paper testified the effect of pumping phase of the piston on vibration and noise of th high pressure tandem axial type piston pump on the best of theoretical research in $this^(1)$. Therefore considering the pumping phase of the piston when assembling the tandem axial type piston pump, it is possible to reduce 1.5~2[dB]of sound level.

  • PDF

Design of closed-loop nitrogen Joule-Thomson refrigeration cycle for 67 K with sub-atmospheric device

  • Lee, C.;Lee, J.;Jeong, S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.1
    • /
    • pp.45-50
    • /
    • 2013
  • Closed-loop J-T (Joule-Thomson) refrigeration cycle is advantageous compared to common open loop $N_2$ decompression system in terms of nitrogen consumption. In this study, two closed-loop pure $N_2$ J-T refrigeration systems with sub-atmospheric device for cooling High Temperature Superconductor (HTS) power cable are investigated. J-T cooling systems include 2-stage compressor, 2-stage precooling cycle, J-T valve and a cold compressor or an auxiliary vacuum pump at the room temperature. The cold compressor and the vacuum pump are installed after the J-T valve to create sub-atmospheric condition. The temperature of 67 K is possible by lowering the pressure up to 24 kPa at the cold part. The optimized hydrocarbon mixed refrigerant (MR) J-T system is applied for precooling stage. The cold head of precooling MR J-T have the temperature from 120 K to 150 K. The various characteristics of cold compressor are invstigated and applied to design parameter of the cold compressor. The Carnot efficiency of cold compressor system is calculated as 16.7% and that of vacuum pump system as 16.4%. The efficiency difference between the cold compressor system and the vacuum pump system is due to difference of enthalpy change at cryogenic temperature, enthalpy change at room temperature and different work load at the pre-cooling cycle. The efficiency of neon-nitrogen MR J-T system is also presented for comparison with the sub-atmospheric devices. These systems have several pros and cons in comparison to typical MR J-T systems such as vacuum line maintainability, system's COP and etc. In this paper, the detailed design of the subcooled $N_2$ J-T systems are examined and some practical issues of the sub-atmospheric devices are discussed.

Comparison of Recovery Rate and Fatty Acid Composition of Dried Sea Cucumbers Apostichopus japonicus Dried by Hybrid Heat Pump Decompression and by Hot Air (2종류의 건조기로 제조한 돌기해삼(Apostichopus japonicus)의 복원율과 지방산조성 비교)

  • Jeong, U-Cheol;Jin, Feng;Anisuzzaman, Md;Choi, Byeong-Dae;Jung, Hyun-Chol;Lee, Sang-Ro;Kang, Seok-Joong
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.52 no.3
    • /
    • pp.232-240
    • /
    • 2019
  • Approximately 80% of the world's sea cucumbers Apostichopus japonicas are processed into dried sea cucumbers. The hot air-drying method is currently used in industry, but it has many problems, such as a short drying time, severe browning, high nutrition loss, and low recovery. In this study, the moisture absorption rate, dry recovery rate, and lipid nutrient composition of sea cucumber dried by heat pump decompression and with a hybrid dryer were investigated. The moisture absorption rates for hybrid-dried sea cucumbers at 24, 48, 72, 96, and 120 h were 241.3%, 427.7%, 652.0%, 721.0%, and 742.2%, respectively. The moisture absorption rates for hot air-dried sea cucumbers were 155.8%, 240.0%, 390.3%, 655.5%, and 667.4%, respectively. Thus, moisture absorption was faster and greater with hybrid drying than with hot air drying. The dry recovery rate at 24 h was greater for hybrid-dried sea cucumber (70.7%) than for hot air-dried sea cucumber (59.8%). Saturated fatty acid contents of the hybrid- and hot air-dried sea cucumbers were 30.0% and 37.5%, respectively. Moreover, greater ${\Sigma}n-3$ polyunsaturated fatty acid content was found in hybrid-dried sea cucumber (15.8%) than in hot air-dried sea cucumber (11.7%).

Development of Metal-free Pump and Uni-material Packaging for Cosmetics to Improve Recycling (재활용성 향상을 위한 화장품용 메탈프리 펌프 및 유니소재 패키징 개발)

  • Sang Kyu, Ryu;Ho Sang, Kang;Jae Young, Oh
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.28 no.3
    • /
    • pp.171-174
    • /
    • 2022
  • Cosmetic packing materials tend to be difficult to recycle when discarded due to the cosmetic industry's pursuit of aesthetics, functionality, and high value-added design. Pump packaging, which is widely used for the good preservation and discharge of cosmetics contents, is difficult to be separated and recycled because of a metal spring, which is in charge of pump resilience. In this study, a polypropylene spring was developed to replace the existing metal spring to improve the recyclability of the pump packaging for cosmetics, and was uni-materialized by applying to the cosmetic packing materials with 0.2 ml of discharge amount. In addition, performance test was conducted to verify the equivalence with the existing metal spring pumps as grounds for the commercialization of metal-free uni material pump packaging. The decompression leak test showed no leakage and displayed 14.8~17.5 N of pressing strength, 2.3~8.8 % of deviation in dispensing volume, and 4 occasions of pumping for initial discharge.

A Solid-Phase Extraction Method for Analyzing Trace Amounts of Polychlorinated Dibenzo-p-Dioxins and Dibenzofurans in Waste Water

  • Park, Deok-Hie;Youn, Yeu-Young;Choi, Jae-Won;Lim, Young-Hee;Cho, Hye-Sung
    • Mass Spectrometry Letters
    • /
    • v.2 no.1
    • /
    • pp.12-15
    • /
    • 2011
  • The Korean government has regulated emission of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in waste water of manufacturing facilities producing chlorinated compounds since 2009. As this regulation is expected to be reinforced in 2013 to 50 pg I-TEQ/L, a large sample volume is required for the analysis of trace amounts of PCDD/Fs in waste water. Liquid-liquid extraction (LLE) is used to extract PCDD/Fs from aqueous samples; however, its low efficiency makes it inadequate for analyzing large sample volumes. Herein, we present a disk-type solid-phase extraction (SPE) method for the analysis of dioxin at a part per quadrillion level in waste water. This SPE system contains airtight glass covers with a decompression pump, which enables continuous semi-automated extraction. Small (0.5 L) and large (7 L) samples were extracted using LLE and SPE methods, respectively. The method detection limits (MDLs) were 0.001.0.25 and 0.015.4.1 pg I-TEQ/L for the SPE and LLE methods, respectively. The concentrations of detected congeners with both methods were similar. However, the concentrations of several congeners that were not detected with the LLE method were quantified using the SPE method.