• Title/Summary/Keyword: daytime temperature

Search Result 319, Processing Time 0.024 seconds

Characteristics of the Seasonal Variation of the Radiation in a Mixed Forest at Kwangneung Arboretum (광릉수목원 혼합림에서 복사 에너지의 계절 변화 특성)

  • 김연희;조경숙;김현탁;엄향희;최병철
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.3
    • /
    • pp.285-296
    • /
    • 2003
  • The measurement of the radiation energy, trunk temperature, leaf area index (LAI), air temperature, vapor pres-sure, and precipitation has been conducted under a mixed forest at Kwangneung Arboretum during the period of 2001. Characteristics of the diurnal and seasonal variation of the radiative energy were investigated. The aerodynamic roughness length was determined as about 1.6 m and the mean albedo was about 0.1 The downward short-wave radiation was linearly correlated with the net radiation and its correlation coefficient was about 0.96. From this linear relation, the heating coefficient was calculated and its annual mean value was about 0.21 The albedo and heating coefficient was varied with season, surface characteristics, and meteorological conditions. The diurnal and seasonal variations of radiation energy were discussed in terms of the surface characteristics and meteorological conditions. In the daytime, during clear skies, net radiation was dominated by the shortwave radiation. In presence of clouds and fog, the radiation energy was diminished. At night, the net radiation was entirely dominated due to the net longwave radiation. There was no distinct diurnal variation in net radiation flux during the overcast or rainy days. The net radiation was strongest in spring and weakest in winter. The seasonal development in leaf area was also reflected in a strong seasonal pattern of the radiation energy balance. The timing, duration, and maximum leaf area and trunk temperature were found to be an important control on radiation energy budget. The trunk temperature was either equal or warmer than air temperature during most of the growing season because the canopy could absorb a substantial amount of sunlight. After autumn (after the middle of October), the trunk temperature was consistently cooler than air temperature.

Evaluation of the Outdoor Radiant Thermal Environment by Building Scale and Block Type of Office Building in Summer (사무소건물의 규모 및 배치유형에 따른 하기 옥외 복사열환경 평가)

  • Park, Su-Jin;Jung, Sun-Young;Yoon, Seong-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.6
    • /
    • pp.81-87
    • /
    • 2009
  • The purpose of this study is to evaluate of the outdoor thermal environment by building scale and block type as variable factors. In this study, 18 cases of office in central business district that have different condition are compared about their surface temperature, HIP(Heat Island Potential), and MRT(Mean Radiant Temperature). They are simulated with 3-dimension numerical simulation software named Hoyano-model. The output results contain visualized distribution chart and numerical data. The results of evaluation are as follows. (1)The surface temperature of the building becomes higher as building coverage ratio is higher but floor area ratio is lower. In same conditions, unified block type is maximum $3.2^{\circ}C$ higher than divided block type. (2)HIP shows different daily pattern as block type. During daytime, divided block type is much higher than unified block type but after sunset, it is changed. (3)MRT shows different distribution pattern as sunlight moves expecially at noon. (4)As the results of this study, cases that have high floor area ratio condition show lower surface temperature by tendency to stay low indoor temperature in office building and big rate of windows on building surface.

Night Interruption and Night Temperature Regulate Flower Characteristics in Cymbidium

  • Kim, Yoon-Jin;Park, Chae-Jeong;Rho, Hyung-Min;Kim, Ki-Sun
    • Horticultural Science & Technology
    • /
    • v.30 no.3
    • /
    • pp.236-242
    • /
    • 2012
  • We investigated the influences of night interruption (NI) and night temperature on flowering and flower coloration in Cymbidium. Cymbidium 'Red Fire' and 'Yokihi' were grown under a 9 hours photoperiod (control), a 9 hours photoperiod with NI at a low light intensity (LNI) of 3-7 ${\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, or a 9 hours photoperiod with NI at a high light intensity (HNI) of 120 ${\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ for four hours (22:00-02:00 HR) for 16 weeks during the reproductive growth stage (Experiment 1). Thirty month-old Cymbidium 'Red Fire' plants with initiated flowering buds were placed in four different growth chamber with night temperature set points of 6, 9, 12, or $15^{\circ}C$ for 16 hours (18:00 to 09:00 HR) and a daytime temperature of $25^{\circ}C$ (Experiment 2). In Experiment 1, the numbers of visible buds and flowers increased, and time to flowering decreased in both the LNI and HNI treatments, as compared to the control in both cultivars. Red color in Cymbidium 'Red Fire' increased by both LNI and HNI, as evidenced by an increased $a^*$ in plants grown under these conditions, relative to those grown under the control condition. Number of days to visible buds at 9-$15^{\circ}C$ ranged from 31-34 days, as compared to 39 days at $6^{\circ}C$ in Experiment 2. Although as the temperature increased days to flowering decreased when the plant was grown at $15^{\circ}C$ as compared to 6, 9, or $12^{\circ}C$, the red color ($a^*$) also decreased. The number of flowers and percent flowering increased when the night temperature was maintained higher than $9^{\circ}C$. Therefore, NI treatment and maintaining the night temperature at approximately 9-$12^{\circ}C$ during the winter season after flower spike initiation in the reproductive developmental growth stage improve flower quality and controls flowering time.

The Design Criteria of the Indoor Temperature and Humidity for the Prevent Condensation of Small Apartment Buildings (소형 공동주택의 동계 실내온습도 조사를 통한 결로방지 설계 기준온습도 설정방안)

  • Kim, Gil-Tae;Kim, Jong-Yeob;Hwang, Ha-Jin;Kim, Kyoung-Sik
    • Land and Housing Review
    • /
    • v.5 no.4
    • /
    • pp.291-296
    • /
    • 2014
  • The apartment buildings were hard to emission of water vapor by reduced infiltration. The purpose of this study was to investigate the generation of indoor temperature and humidity in the recent construction of small size apartment buildings. The temperature and humidity were measured in 3 apartments in Seongnam and Daejeon city. During the winter indoor temperature and relative humidity were measured ranged from 20 to $24^{\circ}C$ and 40 to 60%. Generated humidity caused by various characteristics of the residents, rather than external influences. Compare daytime (6:00 to 22:00) and nighttime (22:00 to 6:00), the temperature is low and absolute humidity is high at nighttime. Condensation is likely to occur at nighttime. Using the cumulative relative frequency and absolute humidity, small apartments design criteria (temperature, relative humidity) can be set.

Evaluation of Heat Waves Predictability of Korean Integrated Model (한국형수치예보모델 KIM의 폭염 예측 성능 검증)

  • Jung, Jiyoung;Lee, Eun-Hee;Park, Hye-Jin
    • Atmosphere
    • /
    • v.32 no.4
    • /
    • pp.277-295
    • /
    • 2022
  • The global weather prediction model, Korean Integrated Model (KIM), has been in operation since April 2020 by the Korea Meteorological Administration. This study assessed the performance of heat waves (HWs) in Korea in 2020. Case experiments during 2018-2020 were conducted to support the reliability of assessment, and the factors which affect predictability of the HWs were analyzed. Simulated expansion and retreat of the Tibetan High and North Pacific High during the 2020 HW had a good agreement with the analysis. However, the model showed significant cold biases in the maximum surface temperature. It was found that the temperature bias was highly related to underestimation of downward shortwave radiation at surface, which was linked to cloudiness. KIM tended to overestimate nighttime clouds that delayed the dissipation of cloud in the morning, which affected the shortage of downward solar radiation. The vertical profiles of temperature and moisture showed that cold bias and trapped moisture in the lower atmosphere produce favorable conditions for cloud formation over the Yellow Sea, which affected overestimation of cloud in downwind land. Sensitivity test was performed to reduce model bias, which was done by modulating moisture mixing parameter in the boundary layer scheme. Results indicated that the daytime temperature errors were reduced by increase in surface solar irradiance with enhanced cloud dissipation. This study suggested that not only the synoptic features but also the accuracy of low-level temperature and moisture condition played an important role in predicting the maximum temperature during the HWs in medium-range forecasts.

Performance Improvement of an Air Source Heat Pump by Storage of Surplus Solar Energy in Greenhouse (온실 내 잉여 태양열을 이용한 공기열원 히트펌프 성능향상)

  • Kwon, Jin Kyung;Kang, Geum Chun;Moon, Jong Pil;Kang, Youn Ku;Kim, Chung Kil;Lee, Su Jang
    • Journal of Bio-Environment Control
    • /
    • v.22 no.4
    • /
    • pp.328-334
    • /
    • 2013
  • A greenhouse heating system to improve heat pump performance using inside and outside air of greenhouse as a heat source selectively and cut $CO_2$ enrichment costs by delay of greenhouse ventilation was developed. In this system, thermal storage modes divided into inside circulation mode using surplus solar energy and outside circulation mode using outside air heat. The thermal storage modes were designed to be switched mutually according to inside greenhouse temperature and six temperature values were input to control the heat pump operating, thermal storage mode switching and greenhouse heating automatically. Operating characteristics of this system were tested in a plastic greenhouse of non-ventilation condition. The results of test showed that the inside circulation mode began at about 11:00 and lasted for about 210 minutes and inside greenhouse temperature was maintained between $20{\sim}28^{\circ}C$ in spite of non-ventilation. System heating COP of the inside circulation mode in the daytime was 3.35, which was 36% and 25% higher than that of the outside circulation modes in the nighttime and daytime respectively.

Effect of Bagging Material and Removal Time on Soluble Solid and Fruit Color of Oriental Melon(Cucumis melo L. var makuwa Makino) (봉지종류 및 제거시기가 참외의 당도 및 색도에 미치는 영향)

  • Shin, Yong-Seub;Lee, Ji-Eun;Yeon, Il-Kweon;Do, Han-Woo;Cheung, Jong-Do;Kang, Chan-Ku;Choi, Chung-Don;Choi, Seng-Yong
    • Journal of Bio-Environment Control
    • /
    • v.17 no.2
    • /
    • pp.157-161
    • /
    • 2008
  • This experiment was conducted to make eatable fruit of oriental melon with peel, we covered oriental melon fruit with pear, apple and grape paper bag. Temperature inside paper bags was lower than air temperature in daytime but reversed in night. Relative humidity inside paper bags was higher than outside humidity in daytime but reversed in night. Covering with paper bags seemed to make fruit length shorter, fruit width narrower, flesh thickness thinner and fruit weight heavier but no difference was found among treatments. Soluble solid contents of flesh and placenta seemed lower with covering with paper bags but also difference did not find among treatments. Increasing of soluble solid contents of fruits was observed at 5 days after removing paper bags but not immediately at removing paper bags. Fruit hardness and chromaticity were dropped by covering paper bags. Decrease of fruit hardness by covering paper bags made more eatable with peel but more study have to be taken to improve chromaticity and soluble solid of fruits.

A Study of the Residential Environment, Mood States, ADL and Nursing Need of the Elderly who Live Alone (독거노인의 거택환경과 기분상태, 일상생활활동 및 간호요구도에 관한 연구)

  • Kim Jin-Hee;Jung Moon-Hee
    • Journal of Korean Public Health Nursing
    • /
    • v.14 no.1
    • /
    • pp.26-40
    • /
    • 2000
  • This study was conducted to find out residential environment, mood states, ADL(Activity Daily Living) and nursing need of the elderly who live alone. The questionnaire survey was conducted on 154 single household elderly over 65years who live n D-city, Kangwon Province. The data were collected between September 1. 1999 and October 17, 1999 and analyzed by means of SPSS package. The results were as follows; 1. The percentage of the subjects who owned their house was no were than $13\%$., which showed that they still belonged to the economically vulnerable class. As for their residential environment, the average indoor temperature and humidity level were $16.45^{\circ}C\;and\;44.62\%$ respectively during the daytime between September and October, which proved to range within the standard scope. The average indoor illumination level was, however, 43.61 Lux, which showed that their illumination environment was very poor. 2. The average score of their mood states was 3.31. which turned out to be rather low. 3. The mean score of ADL was 1.69, which showed that they didn't have any serious inconveniences in their ordinary lives. 4. The mean score of their nursing need was 275, which proved to be close to the normal level. 5. The higher the room humidity was, the higher their nursing need increased. The higher the degree of illumination level was, the lower the degree of their nursing need was and the higher the level of ADL was. 6. The major factors influencing their moon status were the frequency of their contact with children and room humidity. These two factors could account for $22\%$ of the total mood status. These results suggest that the residential environment should be necessarily considered in the psychological nursing intervention for the elderly who live alone and they should be urgently supported in terms of health policy so that they can maintain the optimum level of illumination during the daytime.

  • PDF

Characteristics of MODIS Satellite Data during Fog Occurrence near the Inchon International Airport

  • Yoo Jung-Moon;Kim Young-Mi;Ahn Myoung-Hwan;Kim Yong-Seung;Chung Chu-Yong
    • Journal of the Korean earth science society
    • /
    • v.26 no.2
    • /
    • pp.149-159
    • /
    • 2005
  • Simultaneous observations of MODIS (Moderate-resolution Imaging Spectroradiometer) onboard the Aqua and Terra satellites and weather station at ground near the Inchon International Airport (37.2-37.7 N, 125.7-127.2 E) during the period from December 2002 to September 2004 have been utilized in order to analyze the characteristics of satellite-observed infrared (IR) and visible data under fog and clear-sky conditions, respectively. The differences $(T_{3.7-11})$ in brightness temperature between $3.75{\mu}m\;and\;11.0{\mu}m$ were used as threshold values for remote-sensing fog (or low clouds) from satellite during day and night. The $T_{3.7-11}$ value during daytime was greater by about 21 K when it was foggy than that when it was clear, but during nighttime fog it was less by 1.5 K than during nighttime clear-sky. The value was changed due to different values of emission of fog particles at the wavelength. Since the near-IR channel at $3.7{\mu}m$ was affected by solar and IR radiations in the daytime, both IR and visible channels (or reflectance) have been used to detect fog. The reflectance during fog was higher by 0.05-0.6 than that during clear-sky, and varied seasonally. In this study, the threshold values included uncertainties when clouds existed above a layer of fog.

Reduction Potential for Thermal Load by Extensive Green Roofs (경량형 옥상녹화에 따른 열부하 저감 잠재성 연구)

  • Kim, Yeon Mee;Nam, Mi A;Jang, Dae Hee;Kim, Hyeon Soo;Kim, Hyun Ok
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.67-77
    • /
    • 2013
  • Based on the increasing demand for a solution to reduce thermal load, extensive green roofs have great opportunity for application to existing roofs due to their light-weight and easy maintenance. The present study delivers data regarding thermal behavior and heat reduction potential in relation to vegetation coverage between green roof types. 1) In the hottest hour in a day, green roofs showed considerable potential to mitigate heat load in roof environments, which can be up to $10^{\circ}C$ difference. 2) Compared to conventional cement roofs, the extensive green roofs only have a slight potential to cool the air over green roofs. By statistical analysis of linear regression, green coverage has little to do with the reduction of air temperature; the cooling effect was proven only in nighttime. 3) Green roofs act as an insulating roof membrane, the inner substrate of green roofs remained cooler than cement roof surfaces in the daytime, but in the nighttime the green roofs generally were warmer than the cement roof surfaces. 4) The variable of vegetation coverage resulted in no significant difference in thermal behavior in the air, but had the greatest effect in keeping the substrate cool in the daytime. The high vegetation coverage also hindered the rapid cooling of the substrate in the nighttime, and therefore was warmer than other measured temperatures. In order to draw a clear conclusion to combat urban heat island effect with extensive green roofs, the experiment needs to be applied on a larger scale.