References
- Alcazar SS & Bass B(2005) Energy performance of green roofs in a multi storey residential building in Madrid. University of Toronto.
- Bousselot J, Klett JE, Koski RD(2011) Moisture content of extensive green roof substrate and growth response of 15 temperate plant species during dry down. HortScience 46(3): 518-522.
- Brenneisen S(2003) Oekologisches Ausgleichspotenzial von extensiven DachbegrueungenBedeutung fuer den Arten- und Naturschutz und die Stadtentwicklungsplanung. Doctoral dissertation, University of Basel, Switzerland.
- Del Barrio, EP(1998) Analysis of the green roofs cooling potential in buildings. Energy and Buildings, 27, 179-193. https://doi.org/10.1016/S0378-7788(97)00029-7
- Desjarlais AO, Zaltash A, Atchley JA (2010) Thermal Performance of vegetative roofing system. Proceedings of 25th RCI International convention. http://www.ornl.gov/sci/ees/etsd/btric/pdfs/ThermalPerfof VegetatedRoofSystems_Mar2010.pdf.
- Getter KL, Rowe DB (2006) The role of extensive green roofs in sustainable development. HortScience 41(5): 1276-1285.
- Jim CY, Tsang SW (2011) Ecological energetics of tropical intensive green roof. Energy and Buildings 43: 2696-2704 https://doi.org/10.1016/j.enbuild.2011.06.018
- Kim HS, Kang JS, Pyon HS (1999) A study on the development of roof-planting system and its thermal performance. Architectural Research 15(3):127-134.
- Koehler M, Schmidt M, Grimme FH, Laar M, Paiva VLA, Tavares S (2002) Green roofs in temperate climates and in the hothumid tropicsfar beyond the aesthetics. Environ Manag Health 13(4): 382391. DOI:10.1108/09566160210439297.
- Lee DK, Yoon SW, Sh SH, Jang SW (2005) The effect of temperature reduction as infludneced by rooftop greening. J. Korean Env. Res. & Reveg. Tech 8(6): 34-44.
- Littell RC, Henry PR, Ammerman CB (1998) Statistical Analysis of Repeated Measures Data using SAS Procedures. Journal of Animal Science 76: 1216-1231. https://doi.org/10.2527/1998.7641216x
- Liu K, Baskaran B (2005) : Thermal performance of green roofs through field evaluation. NRCC-46412. Proceedings for the First North American Green Roof Infrastructure Conference. http://archive.nrc-cnrc.gc.ca/obj/irc/doc/pubs/nrcc46412/nrcc46412.pdf.
- Liu K, Minor J (2005) Performance evaluation of an extensive green roof. In: Greening rooftops for sustainable communities. Washington, DC, pp.111.
- Nardini A, Andri S, Crasso M (2012): Influence of substrate depth and vegetation type on temperature and water runoff mitigation by extensive green roofs: shrubs versus herbaceous plants. Urban Ecosyst 15: 697708. DOI 10.1007/s11252-011-0220-5.
- Oh SH (2007) The analysis of temperate reduction effect of an extensive green roof. Master Thesis. Seoul National University.
- Oke, TR (1987) Boundary layer climates. New York.
- Park EJ, Kang KI, Nam MA (2010) Green roof strategy for mitigating the urban heat island effect. Policy research 2010-25, Gyeonggi Researc Institute pp.1-168.
- Simmons MT, Gradiner B, Windhager S (2008) Green roofs are not created equal: the hydrologic and thermal performance of six different extensive green roofs and reflective and non-reflective roofs in a sub-tropical climate. Urban Ecosyst. DOI 10.1007/s111252-008-0069-4.
- Unger, J. (2004). Intra-urban relationship between surface geometry and urban heat island. Review and new approach. Climate Research, 27, 253e264. https://doi.org/10.3354/cr027253
- Wanphen S, Nagano K (2009) Experimental study of the perfor mance of porous materials to moderate the roof surface temperature by its evaporative cooling effect. Building and Environment 44: 338-351. https://doi.org/10.1016/j.buildenv.2008.03.012
- Wong NH, Chen Y, Ong CL, Sia A (2003) Investigation of thermal benefits of rooftop garden in the tropical environment. Building and Environment 38: 261-270. https://doi.org/10.1016/S0360-1323(02)00066-5
- Wong NH, Cheong KKW, Yan H, Soh J, Ong CL, Sia A (2003): The effects of rooftop garden on energy consumption of a commercial building in Singapore. Energy and Buildings 35: 353-364. https://doi.org/10.1016/S0378-7788(02)00108-1
Cited by
- 엔지니어링 PE방수.방근시트가 결합된 박스 유닛형 옥상 녹화 시스템 적용을 위한 성능평가 vol.16, pp.2, 2013, https://doi.org/10.5345/jkibc.2016.16.2.125