Comparative Analysis on the Biomass Production between Machine-Transplanted and Water-Broadcast Seeded Silage Rice in the Central Plain Area of Korea (중부 평야지에서 사료용 벼 기계이앙과 담수산파 재배의 건물 생산성 비교 분석)

  • Yang, Woonho;Park, Jeong-Hwa;Kang, Shingu;Kim, Sukjin;Choi, Jong-Seo
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.63 no.3
    • /
    • pp.186-195
    • /
    • 2018
  • A field study was conducted over a 3-year period from 2014 to 2016 in the central plain area, Suwon, Korea, 1) to compare the biomass production between machine-transplanted and water-broadcast seeded silage rice and 2) to elucidate the growth factors that affect the difference in biomass production between the two cultivation practices. The heading date for the water-broadcast seeded silage rice was September 11-18, which was delayed by 11-17 days when compared to that for the machine-transplanted silage rice. On average, water-broadcast seeded silage rice had a shorter plant height, more panicles per area, and a greater biomass production because of the increased straw dry weight. However, the difference in dry weight of each plant organ between the two cultivation practices exhibited yearly variation. When the data were pooled across experimental years, cultivation practices, and varieties, biomass production was highly positively correlated with straw dry weight but not with panicle dry weight. When the ratio of water-broadcast seeding to machine-transplanting was analyzed, total dry weight and straw dry weight were positively associated with each other, whereas no relationship was found between total dry weight and panicle dry weight. Despite that water-broadcast seeded silage rice produced more panicles per area than machine-transplanted silage rice, the two cultivation practices had a similar dry weight per culm. Therefore, we conclude that the silage rice from the water-broadcast seeding, compared to the machine-transplanting, produced more biomass because of the combination of the increased panicle number per area and a similar dry weight per culm. These results suggest that silage rice could be produced through water-broadcast seeding to increase biomass production with low labor and cost input.

The Influence of Iteration and Subset on True X Method in F-18-FPCIT Brain Imaging (F-18-FPCIP 뇌 영상에서 True-X 재구성 기법을 기반으로 했을 때의 Iteration과 Subset의 영향)

  • Choi, Jae-Min;Kim, Kyung-Sik;NamGung, Chang-Kyeong;Nam, Ki-Pyo;Im, Ki-Cheon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.122-126
    • /
    • 2010
  • Purpose: F-18-FPCIT that shows strong familiarity with DAT located at a neural terminal site offers diagnostic information about DAT density state in the region of the striatum especially Parkinson's disease. In this study, we altered the iteration and subset and measured SUV${\pm}$SD and Contrasts from phantom images which set up to specific iteration and subset. So, we are going to suggest the appropriate range of the iteration and subset. Materials and Methods: This study has been performed with 10 normal volunteers who don't have any history of Parkinson's disease or cerebral disease and Flangeless Esser PET Phantom from Data Spectrum Corporation. $5.3{\pm}0.2$ mCi of F-18-FPCIT was injected to the normal group and PET Phantom was assembled by ACR PET Phantom Instructions and it's actual ratio between hot spheres and background was 2.35 to 1. Brain and Phantom images were acquired after 3 hours from the time of the injection and images were acquired for ten minutes. Basically, SIEMENS Bio graph 40 True-point was used and True-X method was applied for image reconstruction method. The iteration and Subset were set to 2 iterations, 8 subsets, 3 iterations, 16 subsets, 6 iterations, 16 subsets, 8 iterations, 16 subsets and 8 iterations, 21 subsets respectively. To measure SUVs on the brain images, ROIs were drawn on the right Putamen. Also, Coefficient of variance (CV) was calculated to indicate the uniformity at each iteration and subset combinations. On the phantom study, we measured the actual ratio between hot spheres and back ground at each combinations. Same size's ROIs were drawn on the same slide and location. Results: Mean SUVs were 10.60, 12.83, 13.87, 13.98 and 13.5 at each combination. The range of fluctuation by sets were 22.36%, 10.34%, 1.1%, and 4.8% respectively. The range of fluctuation of mean SUV was lowest between 6 iterations 16 subsets and 8 iterations 16 subsets. CV showed 9.07%, 11.46%, 13.56%, 14.91% and 19.47% respectively. This means that the numerical value of the iteration and subset gets higher the image's uniformity gets worse. The range of fluctuation of CV by sets were 2.39, 2.1, 1.35, and 4.56. The range of fluctuation of uniformity was lowest between 6 iterations, 16 subsets and 8 iterations, 16 subsets. In the contrast test, it showed 1.92:1, 2.12:1, 2.10:1, 2.13:1 and 2.11:1 at each iteration and subset combinations. A Setting of 8 iterations and 16 subsets reappeared most close ratio between hot spheres and background. Conclusion: Findings on this study, SUVs and uniformity might be calculated differently caused by variable reconstruction parameters like filter or FWHM. Mean SUV and uniformity showed the lowest range of fluctuation at 6 iterations 16 subsets and 8 iterations 16 subsets. Also, 8 iterations 16 subsets showed the nearest hot sphere to background ratio compared with others. But it can not be concluded that only 6 iterations 16 subsets and 8 iterations 16 subsets can make right images for the clinical diagnosis. There might be more factors that can make better images. For more exact clinical diagnosis through the quantitative analysis of DAT density in the region of striatum we need to secure healthy people's quantitative values.

  • PDF

Reference Values and Water quality Assessment Based on the Regional Environmental Characteristics (해역의 환경특성을 고려한 해양환경 기준설정과 수질등급 평가)

  • Rho, Tae-Keun;Lee, Tong-Sup;Lee, Sang-Ryong;Choi, Man-Sik;Park, Chul;Lee, Jong-Hyun;Lee, Jae-Young;Kim, Seung-Su
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.17 no.2
    • /
    • pp.45-58
    • /
    • 2012
  • For the development of reference values and evaluation of water quality in various environmental conditions, we divided the coastal region around Korean peninsular into 5 distinctive ecological regions based on the influence of surface current, depth, tidal range, turbidity, and climate condition. We used national marine environment monitoring data collected by National Fisheries Research & Development Institute(NFRDI) from 2000-2009. For the reference values, we used maximum seasonal mean from 2000 to 2007 for DIN, DIP, and chlorophyll-a and minimum seasonal mean for secchi depth measured at stations without the influence of river runoff in each ecological regions. For the reference value of bottom dissolved oxygen saturation, we used minimum mean value of 90% calculated from minimal riverine influence stations of whole regions. We calculated enrichment score for each assessment criteria. The enrichment score of DIN, DIP, and Chlorophyll-a was 1 (=< reference value), 2 (< 110% of reference value), 3 (< 125% of reference value), 4 (< 150% of reference value), and 5 (> 150% of reference value). The enrichment score of DO saturation and Secchi depth was 1 (> reference value), 2 (> 90% of reference value), 3 (>75 % of reference value), 4 (> 50% of reference value), and 5 (< 50% of reference value). We calculated water quality index using weighted linear combination of five enrichment score for the comparison of whole regions. From the water quality index distribution calculated from all stations between 2000 and 2007 period, we classified into 5 grade based on the standard deviation calculated from total water quality index. We assigned grade very good(I), good(II), moderate(III), bad(IV), and very bad(V) when the water quality index was less than 23, minimum + 1 sd, +2 sd, +3 sd, and grater than minium+ 3 sd, respectively.

An Analysis of the Use of Media Materials in School Health Education and Related Factors in Korea (학과보건교육에서의 매체활용실태 및 영향요인 분석)

  • Kim, Young-Im;Jung, Hye-Sun;Ahn, Ji-Young;Park, Jung-Young;Park, Eun-Ok
    • Journal of the Korean Society of School Health
    • /
    • v.12 no.2
    • /
    • pp.207-215
    • /
    • 1999
  • The objectives of this study are to explain the use of media materials in school health education with other related factors in elementary, middle, and high schools in Korea. The data were collected by questionnaires from June to September in 1998. The number of subjects were 294 school nurses. The PC-SAS program was used for statistical analysis such as percent distribution, chi-squared test, spearman correlation test, and logistic regression. The use of media materials in health education has become extremely common. Unfortunately, much of the early materials were of poor production quality, reflected low levels of interest, and generally did little to enhance health education programming. A recent trend in media materials is a move away from the fact filled production to a more affective, process-oriented approach. There is an obvious need for health educators to use high-quality, polished productions in order to counteract the same levels of quality used by commercial agencies that often promote "unhealthy" lifestyles. Health educators need to be aware of the advantages and disadvantages of the various forms of media. Selecting media materials should be based on more than cost, availability, and personal preference. Selection should be based on the goal of achieving behavioral objectives formulated before the review process begins. The decision to use no media materials rather than something of dubious quality usually be the right decision. Poor-quality, outdated, or boring materials will usually have a detrimental effect on the presentation. Media materials should be viewed as vehicles to enhance learning, not products that will stand in isolation. Process of materials is an essential part of the educational process. The major results were as follows : 1. The elementary schools used the materials more frequently. But the production rate of media materials was not enough. The budget was too small for a wide use of media materials in school health education. These findings suggest that all schools have to increase the budget of health education programs. 2. Computers offer an incredibly diverse set of possibilities for use in health education, ranging from complicated statistical analysis to elementary-school-level health education games. But the use rate of this material was not high. The development of related software is essential. Health educators would be well advised to develop a basic operating knowledge of media equipment. 3. In this study, the most effective materials were films in elementary school and videotapes in middle and high school. Film tends to be a more emotive medium than videotape. The difficulties of media selection involved the small amount of extant educational materials. Media selection is a multifaceted process and should be based on a combination of sound principles. 4. The review of material use following student levels showed that the more the contents were various, the more the use rate was high. 5. Health education videotapes and overhead projectors proved the most plentiful and widest media tools. The information depicted was more likely to be current. As a means to display both text and graphic information, this instructional medium has proven to be both effective and enduring. 6. An analysis of how effective the quality of school nurse and school use of media materials shows a result that is not complete (p=0.1113). But, the budget of health education is a significant variable. The increase of the budget therefore is essential to effective use of media materials. From these results it is recommended that various media materials be developed and be wide used.

  • PDF

Exposure Assessment for Polycyclic Aromatic Hydrocarbons in the Model Menu System of Korean (한국인의 모델식이에 대한 다환방향족탄화수소류(PAHs)의 인체노출량평가)

  • Kim YunHee;Yoon EunKyung;Lee HyoMin;Park KyungAh;Jun EunAh;Lee CherlHo;Choi SangYun;Lim SeungTaek;Ze KeumRyun;Choi KwangSik
    • Journal of Food Hygiene and Safety
    • /
    • v.19 no.4
    • /
    • pp.176-184
    • /
    • 2004
  • This study was conducted to compare and estimate the daily PAHs dietary intake from both home-cooking and dining-out, through approach of model diet used in exposure assessment of food contaminants. Food commodities reflecting in model diet were selected from the KHIDI report and were analysed in cooked or uncooked edible forms using HPLC-Fluorscence Detector. The PAHs dietary intake comparison between home-cooking and dining-out was based on one meal intake suggested in model diet and PAHs dietary intake was estimated by using food consumption rate and body weight of the Korean adult group. The daily PAHs dietary intake was calculated by permutation and combination method with assumption that a person consumed 2 meals from home-cooking menu and 1 meal from dining-out menu. The total PAHs levels in 36 food commodities with 200 samples were ranged from 2.00 ug/kg to 141.28 ug/kg and a food showing the highest PAHs level was the stir-fried anchovy. The $TEQ_{BaP}$ levels of PAHs were calculated using benzo(a)pyrene equivalents individual congener level and corresponding TEF value and the $TEQ_{BaP}$ level were ranged from $0.03\;ugTEQ{BaP}$ to $1.31\;ugTEQ_{BaP}$ and a food showing the highest $TEQ_{BaP}$ level was the hamburger. The PAHs dietary intakes per one meal from home-cooking and dining-out were $2.4\times10^{-3}\;ugTEQ_{BaP}/kg/meal\;and\;4.0\times10^{-3}\;ugTEQ_{BaP}/kg/meal$, respectively. This data showed the PAHs dietary intake from dining-out was about 1.7 times higher than from the home-cooking. The daily PAHs dietary intakes of general Korean adult having two meals from home-cooking and one meal from dining-out per a day were ranged between $8.0\times10^{-3}\~9.7\times10^{-3}\;ugTEQ_{BaP}/gg/day$ and mean value as $8.9\times10^{-3}\~9.7\times10^{-3}\;ugTEQ_{BaP}/gg/day$.

INFLUENCE OF SEVERAL POSTS AND IPS-EMPRESS INGOT THICKNESS ON THE FINAL SHADE OF ALL-CERAMIC CROWNS (수종의 post와 IPS-Empress Ingot 두께가 전부 도재 수복물 최종색조에 미치는 영향)

  • Bok Won-Mi;Choi Keun-Bae;Park Charn-Woon;Ahn Seung-Geun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.5
    • /
    • pp.514-523
    • /
    • 2004
  • Statement of problem: All-ceramic restorations have been advocated for superior esthetics. Various post and core systems have been used to improve the strength of damaged teeth, but it is unclear whether they affect the final shade of finished all-ceramic restorations. Purpose: The influence of different types of post and core systems on light transmission through all-ceramic crowns was assessed by spectrophotometric analysis. Also the masking effect of different thickness of ceramic ingot was evaluated. Material and Methods : Forty-five sample disks (15mm in diameter) at several thickness(1.0, 1.5, 2.0mm) and value(shade 100, 200, 300) were made in heat pressed ceramic(IPS-Empress). Background specimens simulating gold-alloy cast posts(Type III casting gold alloy), metal posts(Ni-Cr casting alloy) and ceramic posts(CosmoPost) were fabrica-ted. Resin composite(Z250, A3 shade) was used as a tooth substrate reference. For each combination, the change in color was measured with a spectrophotometer. Readings were performed for 2 conditions (1) ability of ceramic to mask the core in relation to its thickness(1.0, 1.5, or 2.0mm) ; (2) influence of post and core types on the final color of the ceramic. Data were recorded according to the CIE $L^*a^*b^*$ systems and color difference($\Delta$E) was calculated. Results: 100 shade ingot: when ceramic thickness was 1.0mm, $\Delta$E value for ceramic post larger than 1 but $\Delta$E value for metal and gold post was larger than 2. For ceramic thickness of 1.5mm, only $\Delta$E value for metal was larger than 2, and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 2. 200 shade ingot: when ceramic thickness was 1.0mm, $\Delta$E value for ceramic post was smaller than 1 but $\Delta$E value for metal and gold post was larger than 2. For ceramic thickness of 1.5 mm, only the $\Delta$E value for metal was larger than 2, and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 1. 300 shade ingot: when ceramic thickness was 1.0mm, only $\Delta$E value for metal was larger than 2 and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 1.5mm, $\Delta$E values for all specimens was smaller than 1. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 1. Conclusion: The final esthetic result of the IPS-Empress glass-ceramic restoration was not affected by the presence of different core materials when the thickness was more than 2.0 mm. When ceramic thickness decreases to 1.5mm, it is advised to take the substrate aspects into consideration. If the ceramic thickness is less than 1.0mm, using the tooth color matched substrate is strongly recommended.

Effects of activators contained in adhesives on dentin bond strengths (상아질 접착제에 포함된 활성제의 사용 유무가 자가중합 복합레진의 상아질에 대한 전단결합강도에 미치는 영향)

  • Kang, Hye-Kyung;Shin, Joo-Hee;Suh, Kyu-Won;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.511-519
    • /
    • 2008
  • Statement of problem: An incompatibility between the initiator systems of self-curing composite resins and light-curing adhesives was supposed recently. Purpose: The purpose of the study was to evaluate the influence of activators for self/dual bonding on dentin shear bonding strengths. Material and methods: Fifty human molars were divided into 5 groups. A flat dentin surface was created for each tooth. A self-curing composite resin (Luxacore) was bonded with the following adhesives (n = 10); One-Step, Prime&Bond NT, AdheSE, Prime&Bond NT and AdheSE were also used in combination with activators. Shear bond strengths were measured after 24 hours of water storage. The specimens were loaded in shear in the Instron until failure at a 1 mm/min crosshead speed. Data were compared using one-way ANOVA and Tukey HSD test (${\alpha}$= 0.05). Results: The dentin adhesive systems in order of decreasing median bond strength were One-Step > Prime&Bond NT with activator, AdheSE with activator > Prime&Bond NT, AdheSE. Among adhesives, One-Step had the highest bond strength. Prime&Bond NT with activator had higher bond strengths than Prime&Bond NT that was used alone, and so was AdheSE. Conclusion: Shear bond strengths were increased in Prime&Bond NT and AdheSE when these were used with activators comparing used without activators. But using activators was not effective clinically comparing One-Step.

Serum Biomarkers for Early Detection of Hepatocellular Carcinoma Associated with HCV Infection in Egyptian Patients

  • Zekri, Abdel-Rahman;Youssef, Amira Salah El-Din;Bakr, Yasser Mabrouk;Gabr, Reham Mohamed;El-Rouby, Mahmoud Nour El-Din;Hammad, Ibtisam;Ahmed, Entsar Abd El-Monaem;Marzouk, Hanan Abd El-Haleem;Nabil, Mohammed Mahmoud;Hamed, Hanan Abd El-Hafez;Aly, Yasser Hamada Ahmed;Zachariah, Khaled S.;Esmat, Gamal
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.3
    • /
    • pp.1281-1287
    • /
    • 2015
  • Background: Early detection of hepatocellular carcinoma using serological markers with better sensitivity and specificity than alpha fetoprotein (AFP) is needed. Aims: The aim of this study was to evaluate the diagnostic value of serum sICAM-1, ${\beta}$-catenin, IL-8, proteasome and sTNFR-II in early detection of HCC. Materials and Methods: Serum levels of IL-8, sICAM-1, sTNFR-II, proteasome and ${\beta}$-catenin were measured by ELISA assay in 479 serum samples from 192 patients with HCC, 96 patients with liver cirrhosis (LC), 96 patients with chronic hepatitis C (CHC) and 95 healthy controls. Results: Serum levels of proteasome, sICAM-1, ${\beta}$-catenin and ${\alpha}FP$ were significantly elevated in HCC group compared to other groups (P-value<0.001), where serum level of IL-8 was significantly elevated in the LC and HCC groups compared to CHC and control groups (P-value <0.001), while no significant difference was noticed in patients with HCC and LC (P-value=0.09). Serum level of sTNFR-II was significantly elevated in patients with LC compared to HCC, CHC and control groups (P-value <0.001); also it was significantly higher in HCC compared to CHC and control groups (P-value <0.001). ROC curve analysis of the studied markers between HCC and other groups revealed that the serum level of proteasome had sensitivity of 75.9% and specificity of 73.4% at a cut-off value of $0.32{\mu}g/ml$ with AUC 0.803 sICAM-1 at cut off value of 778ng/ml, the sensitivity was 75.8% and the specificity was 71.8% with AUC 0.776. ${\beta}$-catenin had sensitivity and specificity of 70% and 68.6% respectively at a cut off value of 8.75ng/ml with an AUC of 0.729. sTNFR-II showed sensitivity of 86.3% and specificity of 51.8% at a cut off value of 6239.5pg/ml with an AUC of 0.722. IL-8 had sensitivity of 70.4% and specificity of 52.3% at a cut off value of 51.5pg/ml with AUC 0.631. Conclusions: Our data supported the role of proteasome, sICAM-1, sTNFR-II and ${\beta}$-catenin in early detection of HCC. Also, using this panel of serological markers in combination with ${\alpha}FP$ may offer improved diagnostic performance over ${\alpha}FP$ alone in the early detection of HCC.

Polymorphisms in Epigenetic and Meat Quality Related Genes in Fourteen Cattle Breeds and Association with Beef Quality and Carcass Traits

  • Liu, Xuan;Usman, Tahir;Wang, Yachun;Wang, Zezhao;Xu, Xianzhou;Wu, Meng;Zhang, Yi;Zhang, Xu;Li, Qiang;Liu, Lin;Shi, Wanhai;Qin, Chunhua;Geng, Fanjun;Wang, Congyong;Tan, Rui;Huang, Xixia;Liu, Airong;Wu, Hongjun;Tan, Shixin;Yu, Ying
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.28 no.4
    • /
    • pp.467-475
    • /
    • 2015
  • Improvement for carcass traits related to beef quality is the key concern in beef production. Recent reports found that epigenetics mediates the interaction of individuals with environment and nutrition. The present study was designed to analyze the genetic effect of single nucleotide polymorphisms (SNPs) in seven epigenetic-related genes (DNMT1, DNMT3a, DNMT3b, DNMT3L, Ago1, Ago2, and HDAC5) and two meat quality candidate genes (CAPN1 and PRKAG3) on fourteen carcass traits related to beef quality in a Snow Dragon beef population, and also to identify SNPs in a total of fourteen cattle populations. Sixteen SNPs were identified and genotyped in 383 individuals sampled from the 14 cattle breeds, which included 147 samples from the Snow Dragon beef population. Data analysis showed significant association of 8 SNPs within 4 genes related to carcass and/or meat quality traits in the beef populations. SNP1 (13154420A>G) in exon 17 of DNMT1 was significantly associated with rib-eye width and lean meat color score (p<0.05). A novel SNP (SNP4, 76198537A>G) of DNMT3a was significantly associated with six beef quality traits. Those individuals with the wild-type genotype AA of DNMT3a showed an increase in carcass weight, chilled carcass weight, flank thicknesses, chuck short rib thickness, chuck short rib score and in chuck flap weight in contrast to the GG genotype. Five out of six SNPs in DNMT3b gene were significantly associated with three beef quality traits. SNP15 (45219258C>T) in CAPN1 was significantly associated with chuck short rib thickness and lean meat color score (p<0.05). The significant effect of SNP15 on lean meat color score individually and in combination with each of other 14 SNPs qualify this SNP to be used as potential marker for improving the trait. In addition, the frequencies of most wild-type alleles were higher than those of the mutant alleles in the native and foreign cattle breeds. Seven SNPs were identified in the epigenetic-related genes. The SNP15 in CAPN1 could be used as a powerful genetic marker in selection programs for beef quality improvement in the Snow Dragon Beef population.

3-Dimensional Micro-Computed Tomography Study on Bone Regeneration with Silk Fibroin, rh-Bone Morphogenetic Protein Loaded-Silk Fibroin and Tricalcium Phosphate Coated-Silk Fibroin in Rat Calvaria Defect

  • Pang, Eun-O;Park, Young-Ju;Park, Su-Hyun;Kang, Eung-Sun;Kweon, Hae-Yong;Kim, Soeng-Gon;Ko, Chang-Yong;Kim, Han-Sung;Nam, Jeong-Hun;Ahn, Jang-Hun;Chun, Ji-Hyun;Lee, Byeong-Min
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.1
    • /
    • pp.1-11
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate the bone regeneration capacity of silk fibroin (SF) when combined with beta tricalcium phosphate (${\beta}$-tricalcium phosphate [TCP]) and rh-bone morphogenetic protein (BMP) in vivo by micro-computed tomography (CT), soft x-ray, and histological analysis. Methods: A total of 56 critical size defects formed by a trephine bur made on 28 adult female Spague-Dawley rats were used for this study and the defect size was 5.0 mm in diameter. The defects were transplanted with (1) no graft material (raw defect), (2) autogenous bone, (3) SF ($10{\mu}g$), (4) SF-BMP ($10{\mu}g$, $0.8{\mu}g$ each), and (5) SF+${\beta}$-TCP ($10{\mu}g$). At 4 and 8 weeks after operation, the experimental animals were sacrificed. Samples were evaluated with soft x-ray, histological examinations and 3-dimensional micro-CT analysis. Results: In the 3-dimensional micro-CT evaluation, bone volume and bone surface data were higher in the SF-BMP ($12.8{\pm}1.5$, $138.6{\pm}45.0$ each) (P<0.05) and SF-TCP ($12.3{\pm}1.5$, $144.9{\pm}30.9$ each) group than in the SF group ($6.1{\pm}3.3$, $77.2{\pm}37.3$ each) (P<0.05), except for the autogenous group ($15.0{\pm}3.0$, $190.7{\pm}41.4$ each) at 4 weeks. At 8 weeks, SF-BMP ($16.8{\pm}3.5$, $173.9{\pm}34.2$ each) still revealed higher (P<0.05) bone volum and surface, but SF-TCP ($11.3{\pm}1.5$, $1132.9{\pm}52.1$ each) (P=0.5, P=0.2) revealed the same or lower amount compared with the SF group ($13.8{\pm}2.7$, $127.5{\pm}44.8$ each). The % of bone area determined by radiodensity was higher in the SF-TCP ($31.4{\pm}9.1%$) and SF-BMP ($36.2{\pm}16.2%$) groups than in the SF ($19.0{\pm}10.4$) group at the period of 4 weeks. Also, in the histological evaluation, the SF-BMP group revealed lower inflammation reaction, lower foreign body reaction and higher bone healing than the SF group at postoperative 4 weeks and 8 weeks. The SF-TCP group revealed lower inflammation at 4 weeks, but accordingly, as the TCP membrane was absorbed, inflammatory and foreign body reaction are increased at 8 weeks. Conclusion: The current study provides evidence that the silk fibrin can be used as an effective grafted material for tissue engineering bone generation through a combination of growth factor or surface treatment.