• 제목/요약/키워드: damping ratios

검색결과 378건 처리시간 0.025초

A simple damper optimization algorithm for both target added damping ratio and interstorey drift ratio

  • Aydin, Ersin
    • Earthquakes and Structures
    • /
    • 제5권1호
    • /
    • pp.83-109
    • /
    • 2013
  • A simple damper optimization method is proposed to find optimal damper allocation for shear buildings under both target added damping ratio and interstorey drift ratio (IDR). The damping coefficients of added dampers are considered as design variables. The cost, which is defined as the sum of damping coefficient of added dampers, is minimized under a target added damping ratio and the upper and the lower constraint of the design variables. In the first stage of proposed algorithm, Simulated Annealing, Nelder Mead and Differential Evolution numerical algorithms are used to solve the proposed optimization problem. The candidate optimal design obtained in the first stage is tested in terms of the IDRs using linear time history analyses for a design earthquake in the second stage. If all IDRs are below the allowable level, iteration of the algorithm is stopped; otherwise, the iteration continues increasing the target damping ratio. By this way, a structural response IDR is also taken into consideration using a snap-back test. In this study, the effects of the selection of upper limit for added dampers, the storey mass distribution and the storey stiffness distribution are all investigated in terms of damper distributions, cost function, added damping ratio and IDRs for 6-storey shear building models. The results of the proposed method are compared with two existing methods in the literature. Optimal designs are also compared with uniform designs according to both IDRs and added damping ratios. The numerical results show that the proposed damper optimization method is easy to apply and is efficient to find optimal damper distribution for a target damping ratio and allowable IDR value.

실측 데이터를 이용한 공용중인 강사장교의 버페팅 응답 분석 (A Study on Buffeting Responses of a In-service Steel Cable-stayed Bridge Using Full-scale Measurements)

  • 이덕근;공민준;유동우
    • 대한토목학회논문집
    • /
    • 제36권3호
    • /
    • pp.349-359
    • /
    • 2016
  • 공용 중인 교량의 버페팅 응답을 해석적으로 평가하기 위해서는 교량 현장의 난류강도, 난류 스펙트럼, 조도계수, 거스트 계수 등 풍하중에 대한 분석이 우선되어야 하고, 해석 결과는 정적 공기력 계수, 플러터계수, 구조 감쇠비, 공기역학적 감쇠비, 고유 진동수 등 여러 변수에 의해 영향을 받는다. 본 논문에서 대상으로 한 교량은 32년째 공용 중에 있는 교량으로써 교량 주변의 지형조건은 설계 및 시공 당시에 비해 많은 변화가 발생하였으며 최근 기후 변화로 인한 풍 환경 역시 큰 변화가 있다. 이러한 이유로 대상교량에서 실측한 풍속 데이터를 분석하여 난류강도, 난류길이, 지표조도계수, 풍속 스펙트럼 등 교량 현장의 풍하중을 평가하였다. 교량 주변의 풍환경 평가 결과, 대상 교량은 해상교량임에도 불구하고 지표조도구분 II의 특성을 나타내고 있었다. 또한 실측한 구조물의 가속도, 변위 응답 데이터를 통해 대상교량의 감쇠비, 정적 공기력 계수, 고유진동수를 평가하여 계측기반 버페팅 해석 변수를 산정하였다. 계측데이터 기반의 해석 변수와 케이블강교량설계지침에 제시된 해석 변수를 적용하여 총 4가지 경우에 대한 버페팅 해석을 수행하였으며, 그 결과 10분 평균 풍속 25m/s이하에서 측정된 버페팅 응답과 계측 기반 해석 변수를 적용한 해석 응답이 가장 잘 일치함을 확인하였고, 계측 풍속과 Gumbel 확률분포를 이용하여 추정한 200년 재현기대 풍속인 45m/s에서의 버페팅 응답을 제시하였다.

인장하중 및 반복하중을 받는 강재 스프링의 변형 성능 평가 (Evaluation of Deformation Capacity of Various Steel Springs Subjected to Tensile Loading or Uniaxial Cyclic Loading)

  • 권희용;황승현;양근혁;김상희;최용수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권4호
    • /
    • pp.1-10
    • /
    • 2022
  • 이 연구에서는 강재 스프링을 감쇠 장치로써 사용 가능성을 평가하기 위해서, 강재 스프링의 인장 및 반복하중 실험을 수행하였다. 주요 실험변수는 강재의 종류(SAE9254 및 SS275), 스프링상수(700 N/mm, 1,000 N/mm 및 1,400 N/mm) 및 SAE9254의 열처리 유·무이다. 인장 실험 결과, SAE9254로 제작된 강재 스프링의 설계 스프링상수와 측정 스프링상수의 비는 1.08 ~ 1.13이며, SS275로 제작된 강재 스프링의 설계 스프링상수와 측정 스프링상수의 비는 0.86 ~ 0.97로 측정되었다. 항복 이후 열처리 유·무에 따른 SAE9254로 제작된 스프링의 하중-변위 관계 기울기는 약 240 ~ 251 kN/mm 및 92 N/mm 이었으며, SS275로 제작된 스프링의 하중-변위 관계 기울기는 거의 0이었다. 반복하중 실험 결과에서 모든 실험체는 KDS 41 17 00 (2019)에서 요구하는 변위 의존형 감쇠 장치의 적합 조건인 변위 원점에서의 하중 조건, 최대변위에서 하중 조건 그리고 에너지 소산 능력 조건을 모두 만족하였다. 그리고 열처리 안 된 SAE9254 및 SS275로 제작된 강재 스프링의 등가 감쇠비는 열처리 된 SAE9254로 제작된 스프링에 비해 각각 약 2.8배 및 1.9배 높은 수준이었다.

Aero-elastic wind tunnel test of a high lighting pole

  • Luo, Yaozhi;Wang, Yucheng;Xie, Jiming;Yang, Chao;Zheng, Yanfeng
    • Wind and Structures
    • /
    • 제25권1호
    • /
    • pp.1-24
    • /
    • 2017
  • This paper presents a 1:25 multi-freedom aero-elastic model for a high lighting pole at the Zhoushan stadium. To validate the similarity characteristics of the model, a free vibration test was performed before the formal test. Beat phenomenon was found and eliminated by synthesis of vibration in the X and Y directions, and the damping ratio of the model was identified by the free decay method. The dynamic characteristics of the model were examined and compared with the real structure; the similarity results were favorable. From the test results, the major along-wind dynamic response was the first vibration component. The along-wind wind vibration coefficient was calculated by the China code and Eurocode. When the peak factor equaled 3.5, the coefficient calculated by the China code was close to the experimental result while Eurocode had a slight overestimation of the coefficient. The wind vibration coefficient during typhoon flow was analyzed, and a magnification factor was suggested in typhoon-prone areas. By analyzing the power spectrum of the dynamic cross-wind base shear force, it was found that a second-order vortex-excited resonance existed. The cross-wind response in the test was smaller than Eurocode estimation. The aerodynamic damping ratio was calculated by random decrement technique and the results showed that aerodynamic damping ratios were mostly positive at the design wind speed, which means that the wind-induced galloping phenomenon is predicted not to occur at design wind speeds.

공진주/비틂 전단(RC/TS)시험기를 이용한 건조 사질토의 변형특성 (Deformational Characteristics of Dry Sand Using Resonant Column / Torsional Shear Testing Equipment)

  • 김동수
    • 한국지반공학회지:지반
    • /
    • 제11권1호
    • /
    • pp.101-112
    • /
    • 1995
  • 동적하중을 받는 지반-구조물 시스템의 설계를 위해 전단탄성계수와 감쇠비로 표현되는 지반의 변형특성의 결정은 매우 중요하다. 본 논문에서는 공진주/비틂전단시험기를 이용하여 저변형률 및 중간 변형률하에서 건조사질토의 변형특성을 연구하였다. 동적시험인 공진주시험과 반복시험인 비틀전단시험을 동일한 공시 체를 이용하여 실시하였다. 진동측정시스템을 개량하여 응력 -변형관계가 하중반복회수와 전단변형률의 크기에 영향을 받지않는 선형영역을 찾았으며 이 영역에서 이력감쇠가 존재함을 나타내었다. 반복한계변형률 이상에서는 하중반복회수에 따라 전단탄성계수는 증가하고 감쇠비는 감소하였다. 사질토의 전단탄성계수와 감쇠비는 진동주파수에 영향을 받지 않으며 의사정적시험인 비틈전단시험에서 변형특성과 동적시험인 공진주 시험에서 얻은 값은 비교시 하중반복회수의 영향을 고려하면 동일하다. 그러므로 공진주l비틀전단시 험을 통해 얻은 변형특성은 지반-구조물시스템의 동적해석은 물론 정적해석에서도 적용할 수 있다.

  • PDF

Rhizoctonia solani에 의한 여름 시금치 잘록병의 방제를 위한 살균제 선발 (Fungicide Screening for Control of Summer Spinach Damping-off Caused by Rhizoctonia solani)

  • 김병섭;윤여순;윤철수;장현철;용영록;홍세진
    • 농약과학회지
    • /
    • 제9권1호
    • /
    • pp.35-40
    • /
    • 2005
  • Rhizoctonia solani AG-4에 의하여 발생하는 여름 시금치 잘록병은 매우 중요한 병이다. 이 병을 방제하기 위하여 13종(pencycuron, trifloxystrobin, pyraclostrobin, azoxystrobin, kresoxim-methyl, validamycin, fluazinam, Benlate-T, flutolanil, cyazofamid, hexaconazole, tebuconazole, prochloraz)의 살균제의 약효를 in vitro와 in vivo 검정을 통하여 평가하였다. In vitro 균사생장 억제 시험 결과 pencycuron, pyraclostrobin, validamycin, fluazinam, Benlate-T, hexaconazole, tebuconazole, flutolanil이 병원균의 생장을 크게 억제하였다. 그러나 trifloxystrobin, azoxystrobin, kresoxim-methyl, cyazofamid, prochloraz은 억제 정도가 낮게 나타났다. 살균제들을 관구처리한 유묘검정(2,000 mg/L)에서 pencycuron, pyraclostrobin, validamycin, fluazinam, Benlate-T, flutolanil은 97.8%, 84.4%, 93.3%, 95.6%, 91.1%, 86.7%의 생존율을 나타냈고, 2,000 mg/L의 농도로 종자처리하였을 때 pencycuron과 pyraclostrobin은 85.1% 이상의 생존율을 나타내었다.

구조실험을 통한 철근콘크리트구조의 내진성능 평가 (Evaluation on Seismic Capacity of reinforced Concrete Structure Based on Structural Testing)

  • 서수연
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.308-318
    • /
    • 2000
  • This paper introduces the acceptance criteria for reinforced concrete moment frames based on structural testing of ACI in preparing and proposes criteria for acceptable limiting drift and energy dissipation ratios of reinforced concrete shear walls for structural testing. Limiting drift and energy dissipation ratios were examined for tests on shear walls having ductile type failures. Test data were analyzed and compared to results for a suggested acceptance criteria that involves a limiting drift that is a function of aspect ratio a limiting energy dissipation ratio that is a function of displacement ductility and damping.

  • PDF

Seismic loading response of piled systems on soft soils - Influence of the Rayleigh damping

  • Jimenez, Guillermo A. Lopez;Dias, Daniel;Jenck, Orianne
    • Geomechanics and Engineering
    • /
    • 제29권2호
    • /
    • pp.155-170
    • /
    • 2022
  • An accurate analysis of structures supported on soft soils and subjected to seismic loading requires the consideration of the soil-foundation-structure interaction. An important aspect of this interaction lies with the energy dissipation due to soil material damping. Unlike advanced constitutive models that can induce energy loss, the use of simple elastoplastic constitutive models requires additional damping. The frequency dependent Rayleigh damping is a formulation that is frequently used in dynamic analysis. The main concern of this formulation is the correct selection of the target damping ratio and the frequency range where the response is frequency independent. The objective of this study is to investigate the effects of the Rayleigh damping parameters in soil-pile-structure and soil-inclusion-platform-structure systems in the presence of soft soil under seismic loading. Three-dimensional analyses of both systems are carried out using the finite difference software Flac3D. Different values of target damping ratios and minimum frequencies are utilized. Several earthquakes are used to study the influence of different excitation frequencies in the systems. The soil response in terms of accelerations, displacements and strains is obtained. For the rigid elements, the results are presented in terms of bending moments and normal forces. The results show that when the frequency of the input motion is close to the minimum (central) frequency in the Rayleigh damping formulation, the overdamping amount is reduced, and the surface spectral acceleration of the analyzed pile and inclusion systems increases. Thus, the bending moments and normal forces throughout the piles and inclusions also increase.

Optimum LCVA for suppressing harmonic vibration of damped structures

  • Shum, K.M.;Xu, Y.L.;Leung, H.Y.
    • Smart Structures and Systems
    • /
    • 제20권4호
    • /
    • pp.461-472
    • /
    • 2017
  • Explicit design formulae of liquid column vibration absorber (LCVA) for suppressing harmonic vibration of structures with small inherent structural damping are developed in this study. The developed design formulae are also applicable to the design of a tuned mass damper (TMD) and a tuned liquid column damper (TLCD) for damped structures under harmonic force excitation. The optimum parameters of LCVA for suppressing harmonic vibration of undamped structures are first derived. Numerical searching of the optimum parameters of tuned vibration absorber system for suppressing harmonic vibration of damped structure is conducted. Explicit formulae for these optimum parameters are then obtained by a series of curve fitting techniques. The analytical result shows that the control performance of TLCD for reducing harmonic vibration of undamped structure is always better than that of non-uniform LCVA for same mass and length ratios. As for the effects of structural damping on the optimum parameters, it is found that the optimum tuning ratio decreases and the optimum damping ratio increases as the structural damping is increased. Furthermore, the optimum head loss coefficient is inversely proportional to the amplitude of excitation force and increases as the structural damping is increased. Numerical verification of the developed explicit design expressions is also conducted and the developed expressions are demonstrated to be reasonably accurate for design purposes.

Effects of viscoelastic memory on the buffeting response of tall buildings

  • Palmeri, A.;Ricciardelli, F.;Muscolino, G.;De Luca, A.
    • Wind and Structures
    • /
    • 제7권2호
    • /
    • pp.89-106
    • /
    • 2004
  • The response of tall buildings to gust buffeting is usually evaluated assuming that the structural damping is of a viscous nature. In addition, when dampers are incorporated in the design to mitigate the response, their effect is allowed for increasing the building modal damping ratios by a quantity corresponding to the additional energy dissipation arising from the presence of the devices. Even though straightforward, this procedure has some degree of inaccuracy due to the existence of a memory effect, associated with the damping mechanism, which is neglected by a viscous model. In this paper a more realistic viscoelastic model is used to evaluate the response to gust buffeting of tall buildings provided with energy dissipation devices. Both cases of viscous and hysteretic inherent damping are considered, while for the dampers a generic viscoelastic behaviour is assumed. The Laguerre Polynomial Approximation is used to write the equations of motion and find the frequency response functions. The procedure is applied to a 25-story building to quantify the memory effects, and the inaccuracy arising when the latter is neglected.