Evaluation on Seismic Capacity of reinforced Concrete Structure Based on Structural Testing

구조실험을 통한 철근콘크리트구조의 내진성능 평가

  • 서수연 (한양대학교 초대형구조시스템연구센터 연구조교수)
  • Published : 2000.04.01

Abstract

This paper introduces the acceptance criteria for reinforced concrete moment frames based on structural testing of ACI in preparing and proposes criteria for acceptable limiting drift and energy dissipation ratios of reinforced concrete shear walls for structural testing. Limiting drift and energy dissipation ratios were examined for tests on shear walls having ductile type failures. Test data were analyzed and compared to results for a suggested acceptance criteria that involves a limiting drift that is a function of aspect ratio a limiting energy dissipation ratio that is a function of displacement ductility and damping.

Keywords