• Title/Summary/Keyword: damaged building

Search Result 366, Processing Time 0.022 seconds

A Basic Study on the Development of Filling Material using Seismic Retrofit of Masonry Architectural Wall Systems in Educational Facilities. (교육시설물의 조적치장벽체 내진보강에 적용 가능한 충전재 개발 기초연구)

  • Lee, Joo-Hyeong;Oh, Jun-Seok;Jeon, Sang-Sub;Son, Ki-Young;Na, Young-Ju
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.180-181
    • /
    • 2019
  • South Korea has long been without major earthquakes. But 317 public facilities have been damaged by Po-Hang earthquake. Among them, 103 educational facilities suffered 25.6 billion won worth of damage. This is the most damaging of public facilities. The earthquake damage was mainly centered on non-seismic retrofit educational facilities and masonry architectural wall systems installed on the outer walls of buildings. Therefore, the purpose of this study is to develop a filling material that can be applied to the non-seismic retrofit of masonry architectural wall systems installed on the outer walls of educational facilities. To achieve the objective, first, set the filling material requirements. Second, set the sequence model of experiments and prepare for the experiment. Third, after the experiment, analyze the results obtained through the experiment. Forth, the optimal filling material is selected by comparing the analyzed results with the requirements. As a results, E-S-X sample using epoxy resin were selected for the seismic retrofit of masonry architectural wall systems in educational facilities. In the future, this study can be used as a basic material for developing seismic reinforcement methods guidelines in domestic existing educational facilities.

  • PDF

Seismic characteristics of a Π-shaped 4-story RC structure with open ground floor

  • Karabini, Martha A.;Karabinis, Athanasios J.;Karayannis, Chris G.
    • Earthquakes and Structures
    • /
    • v.22 no.4
    • /
    • pp.345-353
    • /
    • 2022
  • The configuration of an open ground floor (pilotis) is a common and very critical irregularity observed in multistory reinforced concrete frame structures. The characteristics and the geometrical formation of the beams of the first story proved to be a critical parameter for the overall seismic behavior of this type of Reinforced Concrete (RC) structures. In this work the combination of open ground floor (pilotis) morphology with very strong perimetrical beams at the level of the first story is studied. The observation of the seismic damages and the in situ measurements of the fundamental period of four buildings with this morphology and Π-shaped plan view are presented herein. Further analytical results of a pilotis type Π-shaped RC structure are also included in the study. From the measurements and the analytical results yield that the open ground floor configuration greatly influences the fundamental period whereas this morphology in combination with strong beams can lead to severe local shear damages in the columns of the ground floor. The structural damage was limited in the columns of the ground floor and yet based on the changes of the in situ measured fundamental period the damaged level is assessed as DI=88%. Furthermore, due to the Π-shape of the plan view the tendency of the parts of the building to move independently strongly influences the distribution of the damages over the ground floor vertical elements.

Seismic Fragility of Low-rise Piloti Buildings Designed According to KDS 41 17 00 (KDS 41 17 00에 따라 설계된 저층 필로티 건물의 지진 취약도)

  • Joo, Changhyeok;Kim, Taewan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.26 no.2
    • /
    • pp.49-58
    • /
    • 2022
  • The 2017 Pohang earthquake caused severe damage to low-rise piloti buildings. The damage was caused mainly by column shear failure, and some core walls were as well. The damaged piloti buildings in Pohang City could be relieved if they were designed correctly according to the standards at that time. However, the post-earthquake investigation revealed design, construction, and permission problems. To solve the problems, the Piloti Building Structure Design Guidelines that include strict specifications were published in 2018. Separately, KDS 41 17 00, the seismic design standard for buildings, was enacted in 2019 and it included the guideline contents. Therefore, at least after the publication of the guidelines, piloti buildings, designed by the standard and guidelines, can be expected to possess better seismic performance than existing piloti buildings. To confirm this, the probability of exceedance for several damage state thresholds was estimated for existing and designed piloti buildings. As a result, the probability of damage of designed piloti buildings was very low compared to existing ones. Consequently, it was confirmed that the guideline and standard adequately supplement the structural fragility of existing piloti buildings.

Numerical study to reproduce a real cable tray fire event in a nuclear power plant

  • Jaiho Lee ;Byeongjun Kim;Yong Hun Jung;Sangkyu Lee;Weon Gyu Shin
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1571-1584
    • /
    • 2023
  • In this study, a numerical analysis was performed as part of an international joint research project to reproduce a real cable tray fire that occurred in the heater bay area of the turbine building of a nuclear power plant. A sensitivity analysis was performed on various input parameters to derive results consistent with the sprinkler activation time obtained from the fire event analysis. For all sensitive parameters, the normalized sprinkler activation time correlated well with the power function of the normalized sprinkler height. A correlation equation was developed to identify the sprinkler activation time at any location when determining the slope or fire growth rate under the conditions assuming a linear or t-squared heat release rate (HRR) time curve. Various cable fire growth assumptions were used to determine which assumption was better to provide the prediction coincident with the information given from the fire event analysis in terms of the sprinkler activation time and total energy generated from cables damaged by fire. In the comprehensive analysis of all the sensitive parameters, the standard deviation of the input parameters increased as the sprinkler height decreased. Within the range of the sensitivity parameter values given in this study, when considering all sprinkler heights, the standard deviation of the cable model change was the largest and that of the overhang position change was the smallest.

Analysis of Fire Damaged Concrete Ca(OH)2 by Heating Temperature Using Scanning Electron Microscope and X-ray Diffraction (SEM과 XRD를 이용한 수열온도별 화재피해 콘크리트의 Ca(OH)2 분석)

  • Lim, Gun-Su;Han, Soo-Hwan;Hyun, Seung-Yong;Kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.149-150
    • /
    • 2022
  • In Korea, there is no clearly established technology for diagnosing and evaluating the damage depth of concrete structures created by fire. There have been cases of repairing, reinforcing, and demolishing degraded structures without diagnosing the damage depth. The commonly used phenolphthalein-based carbonate thickness measurement does not satisfy the complete disappearance condition of Ca(OH)2 in the interval where the relatively stationary flow declines after exposure to high temperatures. Even a small amount of Portlandite[Ca(OH)2] reacts with a red color, and the damage depth is misjudged. It was confirmed by X-ray diffraction and scanning electron microscope that Ca(OH)2 existed from 300℃ to 500℃ where the residual compressive strength decreased.

  • PDF

Seismic risk priority classification of reinforced concrete buildings based on a predictive model

  • Isil Sanri Karapinar;Ayse E. Ozsoy Ozbay;Emin Ciftci
    • Structural Engineering and Mechanics
    • /
    • v.91 no.3
    • /
    • pp.279-289
    • /
    • 2024
  • The purpose of this study is to represent a useful alternative for the preliminary seismic vulnerability assessment of existing reinforced concrete buildings by introducing a statistical approach employing the binary logistic regression technique. Two different predictive statistical models, namely full and reduced models, were generated utilizing building characteristics obtained from the damage database compiled after 1999 Düzce earthquake. Among the inspected building parameters, number of stories, overhang ratio, priority index, soft story index, normalized redundancy ratio and normalized lateral stiffness index were specifically selected as the predictor variables for vulnerability classification. As a result, normalized redundancy ratio and soft story index were identified as the most significant predictors affecting seismic vulnerability in terms of life safety performance level. In conclusion, it is revealed that both models are capable of classifying the set of buildings being severely damaged or collapsed with a balanced accuracy of 73%, hence, both are able to filter out high-priority buildings for life safety performance assessment. Thus, in this study, having the same high accuracy as the full model, the reduced model using fewer predictors is proposed as a simple and viable classifier for determining life safety levels of reinforced concrete buildings in the preliminary seismic risk assessment.

Seismic Behavior of Domestic Piloti-type Buildings Damaged by 2017 Pohang Earthquake (2017년 포항지진으로 피해를 입은 국내 필로티형 건물의 지진 거동)

  • Kim, Taewan;Chu, Yurim;Kim, Seung Re;Bhandari, Diwas
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.161-168
    • /
    • 2018
  • Pohang earthquake occurred on November 15, 2017, with a magnitude of 5.4. The damage of the structure caused by the Pohang earthquake was the most significant in 4-story piloti-type buildings, where the damage patterns were different according to the location of columns and walls at the first story. One building with a staircase at a corner shows shear failure at columns, and Another building with a staircase in the middle shows no failure or shear failure at staircase walls. Therefore, two different piloti-type buildings were selected; one has a staircase at a corner and another has in the middle, and the seismic behavior of the buildings were examined by nonlinear dynamic analysis applying a ground motion measured at Pohang. Analytical model well simulated the actual behavior of the piloti-type buildings during the earthquake. Analysis results showed that walls have an insufficient shear strength wherever the location of the staircase is and columns with insufficient transverse reinforcement could be failed when the staircase is located at a corner. Conclusively, structural engineers should design columns and walls in piloti-type buildings to possess sufficient capacity according to the location of staircase.

Experimental Test on the Effect of Onsite Welding of Steel Plates for a Joint Between Concrete Columns and a Steel Belt Truss

  • Shim, Hak Bo;Yun, Da Yo;Park, Hyo Seon
    • International Journal of High-Rise Buildings
    • /
    • v.9 no.2
    • /
    • pp.155-166
    • /
    • 2020
  • To connect exterior reinforced concrete (RC) columns with the steel belt truss, the gusset plates are welded to the steel plates embedded in the RC column. Then, the concrete around an embedded plate is very likely to be damaged by the heat input from a long-time (6 to 48 hours) welding of the embedded and gusset plates at a joint between RC columns and steel belt truss. However, very few studies have assessed the concrete damage caused by the welding heat between embedded and gusset plates, and no clear onsite solution has been found. In this paper, experimental tests have been carried out on 4 full-scale specimen to analyze the effect of long-time (about 6 hours) onsite welding (1-side welding and 3-side welding) between a gusset plate and an embedded plate in high strength concrete with compressive strength of 55 MPa and 80 MPa on RC columns. The effect of the long-time welding heat of embedded and gusset plates, which are used in real high-rise building construction sites, on concrete is analyzed in terms of the following three items: 1) temperature distribution, 2) pattern and characteristics of cracks, and 3) effect of the cracks on the compressive strength of RC column. Based on the experimental results, even though the heat input up to about 150? from the long-time onsite welding on the high-strength concrete column for the joint could result in concrete cracks in a radial form, it is found that the welding cracks have no effect on the axial stiffness and strength of the concrete column.

Mobile Energy Shelter House(MeSH) for victims when a disaster occurs - Focused on Indoor Thermal Environmental Performance - (재난·재해 시 이재민을 위한 이동형 에너지 셜터하우스 (MeSH) 계획 -실내 온열환경 성능을 중심으로-)

  • Shin, Hwayeon;Kim, Jeonggook;Kim, Jonghun;Jeong, Hakgeun;Jang, Cheolyong;Hong, Wonhwa
    • KIEAE Journal
    • /
    • v.14 no.6
    • /
    • pp.75-80
    • /
    • 2014
  • Development of temporary housing for victims whose house damaged is required. In this study is to plan temporary house space 'Mobile Energy Shelter House ; MeSH' that can be inhabited for a long time. And measure the indoor Environmental performance. 'Mobile Energy Shelter House : MeSH' was made by reflecting Passive Design, Universal Design. Also, thermal insulation that meets the 'Korea standard insulation' for use low energy. Winter season, measuring temperature, humidity, air velocity and radiation temperature when floor heating that temperature controllers ware installed is used. Confirmed the data for the 8:00pm to 8:00am because evening hours are expected as residents live. Average outdoor temperature was $-11.3^{\circ}C$ and Indoor temperature was from $16.09^{\circ}C$ to $20.63^{\circ}C$. Calculated the TDRi of the window surface for checked condensation risk. TDRi value was 0.185. Furthermore, PMV value was -0.08 to -0.85. It was satisfied to ISO comfort criterion ranged.

Forced Vibration Testing of a Four-Story Reinforced Concrete Frame Building (철근콘크리트조 4층 골조건물의 강제진동실험)

  • Yu, Eun-Jong;Wallace, John W.
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.2 s.54
    • /
    • pp.27-38
    • /
    • 2007
  • A series of forced vibration tests and ambient vibration measurement was conducted on a four-story reinforced concrete building damaged in the 1994 Northridge earthquake. Both low amplitude broadband and moderate amplitude harmonic excitation were applied using a linear shaker and two eccentric mass shakers, respectively, and ambient vibrations were measured before and after each forced vibration test. Accelerations, interstory displacements, and curvature distributions were monitored using accelerometers, LVDTs and concrete strain gauges. Natural frequencies and the associated mode shapes fur the first 7 modes were identified. Fundamental frequencies determined from the eccentric mass shaker tests were 70% to 75% of the values determined using ambient vibration data, and 92% to 93% of the values determined using the linear shaker test data. Larger frequency drops were observed in the NS direction of the building, apparently due to damage that was induced during the Northridge earthquake.