• Title/Summary/Keyword: damaged building

Search Result 366, Processing Time 0.024 seconds

An Experimental Study on Alkali-Silica Reaction due to Neutron Shielding Concrete Containing Borosilicate Glass Powder (붕규산 유리 분말을 혼입한 차폐용 콘크리트의 알칼리 실리카 반응에 의한 팽창 실험)

  • Jang, Bo-Kil;Kim, Ji-Hyun;Chung, Chul-Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.160-161
    • /
    • 2015
  • Borosilicate glass can be used for improving neutron shielding of concrete. The well known expansion of borosilicate glass caused by expansion of mortar bar was can cause serious damage to the concrete. In this research, borosilicate glass was powdered to reduce the particle size similar to that of cement, and 20% cement replacement set was reduced expansion rate about 30%. But aggregate replacement set was damaged because of Alkali-Silica Reaction expansion.

  • PDF

A Stduy on the Self Healing Performance of Acrylate at Elevated Tmeperature (아크릴레이트의 온도별 자가 보수 성능에 관한 연구)

  • Yoon, Jun-No;Park, Wan-Goo;Choi, Su-Young;Kim, Dong-Bum;Kim, Byoung-Il;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.175-176
    • /
    • 2018
  • In this study, the performance of acrylate was evaluated by using acrylate composite waterproof sheet. Through this experiment, the waterproof sheet plays a primary role of waterproofing. When the water leakage occurs, the acrylate reacts with water and expands, and the performance of the self repairing of the damaged part is confirmed by temperature.

  • PDF

Investigation of blast-induced ground vibration effects on rural buildings

  • Oncu, Mehmet Emin;Yon, Burak;Akkoyun, Ozgur;Taskiran, Taha
    • Structural Engineering and Mechanics
    • /
    • v.54 no.3
    • /
    • pp.545-560
    • /
    • 2015
  • In this paper, blast-induced vibration effects on buildings located in rural areas were investigated. Damages to reinforced concrete, adobe and masonry buildings were evaluated in Çatakk$\ddot{o}pr\ddot{u}$ and Susuz villages in Silvan district of Diyarbakir, Turkey. Blasting of stiff rocks to construct highway at vicinity of the villages damaged the buildings seriously. The most important reason of the damages is lack of engineering services and improper constructed buildings according to the current building design codes. Also, it is determined that, inappropriate blast method and soft soil class increased the damages to the buildings. The study focuses on four points: Blast effect on buildings, soil conditions in villages, building damages and evaluation of damage reasons according to the current Turkish Earthquake Code (TEC).

Determining the Depth of Normal-Strength Concrete with Early-Frost Damage Through Dry Test (초기동해 피해를 입은 보통강도 콘크리트의 건조시험에 의한 깊이판정)

  • Kim, Tae-Woo;Beak, Cheol;Lee, Jae-Jin;Kim, Dong-Gyu;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.65-66
    • /
    • 2017
  • Early-frost damages easily take place in smaller and thinner walls and slabs. In case of slabs, it is difficult to visually determine the depth of early-frost damage. As such, the current study aims to determine the depth of early-frost damage caused to concrete structures due to bad curing in the winter. As a result, the study found that the depth of early-frost damages increased from the top as the atmospheric temperature on the concrete surface decreased. The changes in the color allowed the observer to easily identify the depth of early-frost damage with the naked eye. In particular, the color difference between potentially damaged parts and undamaged parts were the greatest around thirty minutes of drying after wetting.

  • PDF

Development of Multidiretion Incoming Salt Collector (다방향 비래염분 포집기 개발 및 포집 정확도 검증)

  • Park, Dong-Cheon;Ahn, Jae-Cheol;Kim, Woo-Jae;Oh, Sang-Gyun;Kim, Hyo-Youl;Kang, Byung-Hi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.13-14
    • /
    • 2011
  • Reinforced concrete structures are damaged by concrete carbonation, salt attack, and sulfate attack. The evaluation of the amount of chloride ion from the sea is very important to assess the life expectancy of Reinforced Concrete structures. The incoming salt collector which is developed in Japan has been used until the present, Unfortunately, the incoming salt collector has had a bad reputation which is caused by backward wind. The wind from backward causes the reduction of the amount of collected salt in collector's gauze. The collector was developed for excluding the effect of backward wind. The performance of it was verified from analytic and experimental methods.

  • PDF

Damage identification of isolators in base-isolated torsionally coupled buildings

  • Wang, Jer-Fu;Huang, Ming-Chih;Lin, Chi-Chang;Lin, Tzu-Kang
    • Smart Structures and Systems
    • /
    • v.11 no.4
    • /
    • pp.387-410
    • /
    • 2013
  • This paper deals with the damage assessment for isolators of base-isolated building systems considering the torsion-coupling (TC) effect by establishing damage indices. The damage indices can indicate the reduction in lateral stiffness of the isolator story as explicit formulas in terms of modal parameters. In addition, the damage location, expressed in terms of the estimated damage index and eccentricities before and after damage, is also presented. Numerical analysis shows that the proposed algorithms are applicable for general base-isolated multi-story TC buildings. A procedure from the analysis of seismic response to the implementation of damage indices is demonstrated by using a numerical case. A system identification technique is employed to extract modal parameters from seismic responses of a building. Results show that the proposed indices are capable of detecting the occurrence of damage and preliminarily estimating the location of damaged isolator.

A Study on the 3D Imaging of High Temperature Heating Cement Paste and the Analysis of Variation of the Pore Structure (고온 가열 시멘트 페이스트의 3D 영상화 및 세공구조 변화 분석에 관한 연구)

  • Kim, Min-Hyouck;Lee, Gun-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.147-148
    • /
    • 2020
  • In case of high temperature damage such as fire, the durability of concrete is reduced due to the collapse of internal pore tissue. Therefore, in this paper, we are going to analyze the pore structure of cement paste hardening agent using MIP analysis and build up 3D data produced using X-ray CT tomography. The test specimen is made of cement paste from W/C 0.4. As the temperature of heating increased, the amount of air gap and the diameter of air gap in cement paste increased. It is judged that the air gap structure inside cement collapsed due to the evaporation of the hydrate, gel count, capillary water, etc. inside the cement due to the high temperature.

  • PDF

Correlations between Compressive Strength and Biaxial Flexural Strength on High-Heated Concrete (고온 수열 콘크리트의 압축강도와 이축휨강도의 상관성 검토)

  • Lee, Gun-Cheol;Kwon, Hyun-Woo;Kim, Young-Min;Heo, Young-Sun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.239-240
    • /
    • 2021
  • In this study, we conducted a study to evaluate the more accurate mechanical properties of concrete damaged by fire. In relation to this, in this study, the results of compressive strength and biaxial flexural strength were compared for concrete that received high temperature heat. As a result, both the compressive strength and the biaxial bending strength decreased as the heating temperature increased. As a result of examining the correlation between the compressive strength and the biaxial flexural strength, the biaxial flexural strength was smaller than the compressive strength.

  • PDF

The Adequacy Evaluation of Limestone for Exterior Use (외부용 라임스톤의 시공 적정성 평가)

  • Kim, Rae-Hwan;Lee, Tae-Gyu;Song, Yeong-Chan;Kim, Yong-Ro;Bang, Jung-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.169-170
    • /
    • 2017
  • In this study, the adequacy evaluation of limestone for exterior use is presented. Major flaws of limestone for exterior use are reviewed. In addition, freezing-thawing test of the limestone specimens were performed. As a result, the limestone specimens was damaged by the freezing and thawing action for 300 cycle.

  • PDF

Vibration Characteristics of a Building Before and After Damage by Actual Measurement (실측을 통한 건물의 손상 전.후 진동특성 평가)

  • Yoon, Sung-Won;Park, Yong
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.5
    • /
    • pp.445-453
    • /
    • 2010
  • Recently, the remodeling projects of old low-rise buildings were launched in Korea. However, most of them were not satisfied with the value set forth by the KBC2005. Even though there are some research studies on how to improve the seismic performance of such buildings as newly constructed buildings, there is little research in measuring the actual vibrations on low old buildings to prove the effect of retrofit. There also has not been any in-depth research on the dynamic characteristics of full-scale structures using vibration measurements of the building that was damaged to failure. Using an actuator, the dynamic characteristics of reinforced three-storey concrete buildings were evaluated before and after they were damaged. After an 80-mm horizontal displacement by the actuator, frequency in the long and short directions were reduced to 20.85% and 5.77% respectively ; damping ratio was also reduced to 53.9% and 23.15% respectively.