• Title/Summary/Keyword: damage diagnosis

Search Result 584, Processing Time 0.026 seconds

Study on the Damage Diagnosis of an Cantilever Beams using PZT Actuator and PVDF Sensor (PZT 액추에이터와 PVDF센서를 이용한 외팔보의 손상 진단에 관한 연구)

  • 권대규;임숙정;유기호;이성철
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.5
    • /
    • pp.73-82
    • /
    • 2004
  • This paper presents the study on damage diagnosis of an intelligent cantilevered beams using PZT actuator and PVDF sensor This study provides the theoretical and experimental verification to examine structural damage. Time domain analysis for the non-destructive detection of damage is presented by parameterized partial differential equations and Galerkin approximation techniques. The time histories of the vibration response of structure were used to identify the presence of damage. Furthermore, this systematic approach permits one to use the piezomaterials to both excite and sense the vibration of structures. We also carried out the experimental verification about reliability of theoretical methods fur detecting the damage of a composite beam with PZT actuator and PVDF sensor. Experimental results are presented from tests on cantilevered composite beams which is damaged at different location and different dimensions. The results were compared with the simulation results. Good agreement between the results was found for the time shifts and amplitude difference in transients response of the cantilevered beam.

Assessment of Bearing Damage by Ultrasonic Measurement (초음파 측정에 의한 베어링손상 평가)

  • LEE SANG-GUK;LEE In-CHEOL
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.395-400
    • /
    • 2004
  • For the purpose of monitoring by ultrasonic test of the ball bearing conditions in rotating machinery, a system for their diagnosis was developed. ultrasonic technique is used to detect abnormal conditions in the bearing system. And various data such as frequency spectrum, energy and amplitude of ultrasonic signals, and ultrasonic parameters were acquired during experiments with the simulated ball bearing system. Based on the above results and practical application for power plant, algorithms and judgement criteria for diagnosis system was established. Bearing diagnosis system is composed of four parts as follows : sensing part for ultrasonic sensor and preamplifier, signal processing part for measuring frequency spectrum, energy and amplitude, interface part for connecting ultrasonic signal to PC using A/D converter, graphic display and software part for display of bearing condition and for managing of diagnosis program.

  • PDF

A Study on the Ultrasonic Measurement for Damage Evaluation of Power Plant Bearing (발전용 베어링 손상평가를 위한 초음파 측정 연구)

  • Lee, Sang-Guk
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1727-1732
    • /
    • 2004
  • For the purpose of monitoring by ultrasonic test of the ball bearing conditions in rotating machinery, a system for their diagnosis was developed. ultrasonic technique is used to detect abnormal conditions in the bearing system. And various data such as frequency spectrum, energy and amplitude of ultrasonic signals, and ultrasonic parameters were acquired during experiments with the simulated ball bearing system. Based on the above results and practical application for power plant, algorithms and judgement criteria for diagnosis system was established.

  • PDF

Development of Fault Diagnosis System for Ram in PHWR Plant (램집합체 이상진단 시스템의 개발)

  • 변승현;조병학;신창훈;양장범
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1319-1322
    • /
    • 2004
  • In this paper, a fault diagnosis system for ram in PHWR plant is developed. The developed diagnosis system can detect the ram stuck phenomena due to increased ball wear and damage in ball nut using discrete wavelet transform before the ram is stuck. The validity of developed diagnosis system is shown via experiments using ball nut characteristic test equipment.

  • PDF

Estimation of Probability Density Functions of Damage Parameter for Valve Leakage Detection in Reciprocating Pump Used in Nuclear Power Plants

  • Lee, Jong Kyeom;Kim, Tae Yun;Kim, Hyun Su;Chai, Jang-Bom;Lee, Jin Woo
    • Nuclear Engineering and Technology
    • /
    • v.48 no.5
    • /
    • pp.1280-1290
    • /
    • 2016
  • This paper presents an advanced estimation method for obtaining the probability density functions of a damage parameter for valve leakage detection in a reciprocating pump. The estimation method is based on a comparison of model data which are simulated by using a mathematical model, and experimental data which are measured on the inside and outside of the reciprocating pump in operation. The mathematical model, which is simplified and extended on the basis of previous models, describes not only the normal state of the pump, but also its abnormal state caused by valve leakage. The pressure in the cylinder is expressed as a function of the crankshaft angle, and an additional volume flow rate due to the valve leakage is quantified by a damage parameter in the mathematical model. The change in the cylinder pressure profiles due to the suction valve leakage is noticeable in the compression and expansion modes of the pump. The damage parameter value over 300 cycles is calculated in two ways, considering advance or delay in the opening and closing angles of the discharge valves. The probability density functions of the damage parameter are compared for diagnosis and prognosis on the basis of the probabilistic features of valve leakage.

A study on the improvement plans of precision safety inspection and precision safety diagnosis in tunnel structure (터널구조물 정밀안전점검 및 정밀안전진단 개선방안 고찰)

  • Lee, Gyu-Phil;Kim, Jeong-Heum
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.2
    • /
    • pp.183-192
    • /
    • 2022
  • Function and performance degradation in tunnel structure can cause road's function loss, proactive maintenance is needed to prevent the initial damage from progressing to intensified damage. Inspection and diagnosis are implemented in accordance with regulations, but it does not fully reflect maintenance processes such as inspection and diagnosis, planning rehabilitation and carrying out. It was carried out for 5,540 cases inspection and diagnosis result in 1,728 tunnels was analyzed to suggest rational maintenance plan in this study.

An Experimental Study on the Engineering Properties of Deteriorated Concrete using Recycled Fine Aggregate by Fire Damage (재생잔골재를 활용한 화재피해를 입은 콘크리트의 공학적 특성에 관한 실험적 연구)

  • Kwon, Yung-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.1
    • /
    • pp.190-196
    • /
    • 2006
  • In the existed study, a fire outbreak in a reinforced concrete structure looses the organism by the different contraction and expansion of hardened cement pastes and aggregate, and causes cracks by thermal stress, leading to the deterioration of the durability. So accurate diagnosis of deterioration is needed based on mechanism of fire deterioration in general concrete structures. Fundamental information and data on the Properties of concrete exposed to high temperature are necessary for accurate diagnosis of deterioration. Therefore, This study is willing to propose fundamental data for quick and accurate diagnosis of deteriorated concrete structure by fire damage with making variable concrete test specimen, exposing high temperature environment, observing the explosive spalling and examining engineering property.

A Study on the Noise Diagnosis and Suppression of the Temperature Sensor in the LCD Plant (LCD공장 내부의 온도센서 노이즈진단 및 억제에 관한 연구)

  • Kim, Kyung-Chul;Choi, Hyoung-Bum;Hwang, Young-Rok;Kim, Yong-Kwan;You, Chang-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.35-41
    • /
    • 2012
  • As automation equipment and electronic device progresses, the importance of power quality is more increasing. This paper represents the analysis and suppression about the causes of trouble by the inverter's ON/OFF noise in plant in order to prevent damage resulting in a secondary damage to conduct precise diagnosis and effective noise reduction. The countermeasure as a reduced carrier frequency and the LC resonant filter had been applied and confirmed the effective results to solve the trouble of noise.

An Experimental Study on the Engineering Properties of Deteriorated Concrete by Fire Damage According to Curing Conditions (화재피해를 입은 콘크리트의 폭력에 대한 양생조건의 영향성 검토에 관한 연구)

  • Na, Chul-Sung;Kim, Young-Sun;Kim, Jae-Hwan;Kwon, Yung-Jin;Kim, Gyu-Yong;Kim, Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.557-560
    • /
    • 2006
  • In the existed study, a fire outbreak in a reinforced concrete structure looses the organism by the different contraction and expansion of hardened cement pastes and aggregate, and causes cracks by thermal stress, leading to the deterioration of the durability. So accurate diagnosis of deterioration is needed based on mechanism of fire deterioration in general concrete structures. Fundamental information and data on the properties of concrete exposed to high temperature are necessary for accurate diagnosis of deterioration. Therefore, this study is willing to propose fundamental data for accurate diagnosis of deteriorated concrete structure by fire damage with experiment according to the curing conditions.

  • PDF

An Experimental Study on the Engineering Properties of Deteriorated Concrete by Fire Damage According to Design Compressive Strength (화재피해를 입은 콘크리트의 폭렬에 대한 설계기준강도의 영향성 검토에 관한 연구)

  • Na, Chul-Sung;Cho, Bong-Suk;Kim, Jae-Hwan;Kwon, Yung-Jin;Kim, Gyu-Yong;Kim, Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.465-468
    • /
    • 2006
  • In the existed study, a fire outbreak in a reinforced concrete structure looses the organism by the different contraction and expansion of hardened cement pastes and aggregate, and causes cracks by thermal stress, leading to the deterioration of the durability. So accurate diagnosis of deterioration is needed based on mechanism of fire deterioration in general concrete structures. Fundamental information and data on the properties of concrete exposed to high temperature are necessary for accurate diagnosis of deterioration. Therefore, this study is willing to propose fundamental data for quick and accurate diagnosis of deteriorated concrete structure by fire damage with experiment according to the design compressive strength.

  • PDF