• Title/Summary/Keyword: damage diagnosis

Search Result 591, Processing Time 0.028 seconds

Damage Types of Levee and its Maintenance and Repair (제방의 손상 유형 및 보수보강)

  • Moon, Dae-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.144-169
    • /
    • 2010
  • In 2002, property loss caused by failure or leakage of existing river levee structures was about 1.8 trillion in Korean Won, and furthermore in which damages of river structures are getting more severe due to characteristics of extremely extraordinary rain such as torrential rain in the locality or guerrilla heavy rain. In this regards, this paper collects and analyzes those damage records and costs for repair by statistic method, and moreover categorizes the causes of failure, erosion and overtopping of levee structures in large and small scale rivers threatened frequently by typhoon and heavy rainfall. It is believed that the results from the analyses can be used as a basic source in developing criteria of standards for design, construction, maintenance and inspection(or diagnosis) of hydraulic structures such as levee and drain conduit.

  • PDF

Damage Estimation of Cables using PZT (압전소자를 이용한 케이블의 손상평가)

  • Park, Kang-Geun;Kim, Ie-Sung;Kim, Wha-Jung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.11a
    • /
    • pp.235-239
    • /
    • 2008
  • Cable systems are a construction of elements carrying only tension and no compression or bending in membrane structure. Tensile membrane structures are most often used as roofs as they can economically and attractively span large distances. But cable systems have weaknesses to vibration by earthquake, wind and vehicle loads. Damage detection of cable systems by using existing safety diagnosis is difficult to detect the characteristic change of overall structural action. If cable snaps are occurred to cable release and tear in tension structures, these are set up a vibration. So, we used piezo-electric materials, and The principle of operation of a piezoelectric sensor is that a physical dimension, transformed into a force, acts on two opposing faces of the sensing element. In this study, the development on test method of cable system is proposed and tested by tensile strength using piezo-electric materials.

  • PDF

Damage Size Estimation by the Continuous Wavelet Transform of Bending Wave Signals (굽힘파 신호의 연속 웨이블렛 변환을 이용한 결함 크기 평가)

  • Kim, Ik-Kyu;Kim, Yoon-Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.364.1-364
    • /
    • 2002
  • This work is concerned with the damage size estimation by using propagating bonging wave signals in a beam. To this end, we apply the continuous wavelet transforms to the incident waves and the reflected waves from a small damage in a long cylindrical beam. In particular, we propose to use the relative magnitudes of the two kinds of waves along the ridges in the wavelet transformed time-frequency planes. (omitted)

  • PDF

Extravasation Injury and Pressure Sore in Brain Damage Patient with Stiffness of the Limbs

  • Jung, Kyu Hwa;Choi, Hwan Jun;Kim, Jun Hyuk
    • Archives of Reconstructive Microsurgery
    • /
    • v.23 no.1
    • /
    • pp.36-39
    • /
    • 2014
  • Extravasation injury refers to leakage of corrosive liquids from veins, resulting in tissue damage. The authors report on a case of extravasation injury to the left hand after administration of fluid to the antecubital area in a patient with brain damage. In order to minimize the effects of extravasation injury, rapid diagnosis and management are needed. In patients with stiffness, pressure sores can develop requiring more careful management by the medical staff.

Structural Damage Detection by Using the Time-Reversal Process of Lamb Waves and the Imaging Method (Lamb파의 시간-반전과정 및 이미지기법을 이용한 손상탐지)

  • Jun, Yong-Ju;Lee, U-Sik
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.4
    • /
    • pp.320-326
    • /
    • 2011
  • This paper proposes a baseline-free SHM technique in which the time-reversal process of Lamb waves and the imaging method are used. The proposed SHM technique has three distinct features when compared with the authors' previously proposed one: (1) It use the reconstructed signal for damage diagnosis, without need to extract the damage signal as the difference between reconstructed signal and initial input signal; (2) It use the imaging method based on the time-offlight information from the reconstructed signal, instead of using a pattern comparison method; (3) In order to make the damage image more clear, the modified mathematical definition of damage image in a pixel is used. The proposed SHM technique is evaluated through the damage detection experiment for an aluminum plate with damage at different locations.

Newborn Screening for Lysosomal Storage Diseases in Taiwan

  • Lin, Hsiang-Yu;Chuang, Chih-Kuang;Lin, Shuan-Pei
    • Journal of mucopolysaccharidosis and rare diseases
    • /
    • v.3 no.1
    • /
    • pp.14-19
    • /
    • 2017
  • Lysosomal storage diseases (LSDs) are a group of rare inherited metabolic disorders caused by the deficiency of specific lysosomal enzymes and subsequent accumulation of substrates. Enzyme deficiency leads to progressive intra-lysosomal accumulation of the incompletely degraded substances, which cause dysfunction and destruction of the cell and eventually multiple organ damage. Patients have a broad spectrum of clinical phenotypes which are generally not specific for some LSDs, leading to missed or delayed diagnosis. Due to the availability of treatment including enzyme replacement therapy (ERT) and hematopoietic stem cell transplantation for some LSDs, early diagnosis is important. ERT products have been approved with optimal outcomes for some LSDs in the recent decades, including Gaucher, Fabry, mucopolysaccharidosis (MPS) I, Pompe, MPS VI, MPS II, and MPS IVA diseases. ERT can stabilize the clinical condition, prevent disease progression, and improve the long-term outcome of these diseases, especially if started prior to irreversible organ damage. Based on the availability of therapy and suitable screening methods in the recent years, some LSDs, including Pompe, Fabry, Gaucher, MPS I, MPS II, and MPS VI diseases have been incorporated into nationwide newborn screening panels in Taiwan.

A Case of Amyotrophic Lateral Sclerosis (근위축성 측삭 경화증 1예)

  • Lee, Beom-Jun;Jeon, Jin-Hee;Lew, Jae-Hwan;Kim, Tae-Yun
    • The Journal of Internal Korean Medicine
    • /
    • v.21 no.4
    • /
    • pp.661-665
    • /
    • 2000
  • Amyotrophic Lateral Sclerosis(ALS) is a fatal neuromuscular disease characterized by progressive muscle weakness resulting in paralysis. ALS is characterized by both upper and lower motor neuron damage. Diagnostic tests include magnetic resonance imaging(MRI) electromyogram(EMG), muscle biopsy, and blood tests. In order for a definitive diagnosis of ALS to be made, damage must be evident in both upper and lower motor neurons. When three limbs are sufficiently affected, the diagnosis is ALS. There is no cure for ALS. We recently experienced one case of ALS, The patients was diagnosed as ALS by EMG and Symptoms. We diagnosed her as Wea jeung and treated by Herbal-medication based on the differentiation of symtoms. we report change of his symptoms through both western medical treatment and oriental medical treatment.

  • PDF

PLASMA DIAGNOSIS OF FANING TARGETS SPUTTERING SYSTEM FOR DEPOSITION OF BA FERRITE FILMS IN Ar, Xe AND $O_2$ GAS MIXTURE

  • Matsushita, Nobuhiro;Noma, Kenji;Nakagawa, Shigeki;Naoe, Masahiko
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.6
    • /
    • pp.834-838
    • /
    • 1996
  • The diagnosis of the plasma in the facing targets sputtering system was performed in mixture gas of Ar 0.18-0.0 Pa, Xe 0.0-0.18 Pa and $O_2$ 0.02 Pa by using Langmiur's probe and the effect of plasma-damage to surface smoothness and magnetic characteristics of Ba ferrite films was clarified. The electron density $N_e$ and the electron temperature $T_e$ were evaluated at the center of the plasma and at the neighborhood of the anode ring. $T_e$ decreased and $N_e$ increased with increase of $P_{Xe}$ at the center of plasma. For the measurement at the neighborhood of the anode ring, $T_e$ was almost constant and $N_e$ took the minimum value at $P_{Xe}$ of 0.1 Pa, where Ba ferrite films with excellent c-axis orientation and magnetic characteristics were obtained. It was suggested that the restriction of the bombardment of recoiled particles as well as the suppress of plasma-damage were effective for obtaining good surface smoothness and excellent magnetic characteristics and it was useful for decreasing the crystallization temperature of Ba ferrite films.

  • PDF

Clinical Value of Salpingoscopy in Infertility (불임의 진단에 있어서 난관경의 임상적 이용)

  • Park, K.H.;Park, W.I.;Lee, B.Y.;Lee, B.S.;Cho, D.J.;Song, C.H.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.20 no.1
    • /
    • pp.95-98
    • /
    • 1993
  • Salpingoscopy may be helpful in the diagnosis of subclinical epithelial, vascular damage and stricture formation, which may playa significant role in infertility, or predispose women to tubal pregnancy, despite of clear demonstration of tubal patency on hysterosalpingogram. We explored the fallopian tube from the fimbriae to the ampullary-isthmic junction with small rigid flexible endoscope during laparoscopy in sixteen patients from July 1991 to Jan. 1992. All patients have been observed following salpingoscopy for several months. Three pregnancies were achieved in seven patients with bilaterally normal or minimally damaged tubal mucosa. In another five patients with moderate to severe tubal damage, we noted one tubal pregnancy. The other remaining patients are being followed up now. As conclusions, salpingoscopy seems to be an useful tool in the diagnosis of tubal lesions which are not identified by H.S.G., give much help to refine the indications for tubal microsurgery and the selection of patients for GIFT or IVF-ET and to determine the prognostic value in terms of risk for ectopic pregnancy.

  • PDF

Minimum thickness of flat plates considering construction load effect

  • Hwang, Hyeon-Jong;Ma, Gao;Kim, Chang-Soo
    • Structural Engineering and Mechanics
    • /
    • v.69 no.1
    • /
    • pp.1-10
    • /
    • 2019
  • In the construction of flat plate slabs, which are widely used for tall buildings but have relatively low flexural stiffness, serviceability problems such as excessive deflections and cracks are of great concern. To prevent excessive deflections at service load levels, current design codes require the minimum slab thickness, but the requirement could be unconservative because it is independent on loading and elastic modulus of concrete, both of which have significant effects on slab deflections. In the present study, to investigate the effects of the construction load of shored slabs, reduced flexural stiffness and moment distribution of early-age slabs, and creep and shrinkage of concrete on immediate and time-dependent deflections, numerical analysis was performed using the previously developed numerical models. A parametric study was performed for various design and construction conditions of practical ranges, and a new minimum permissible thickness of flat plate slabs was proposed satisfying the serviceability requirement for deflection. The proposed minimum slab thickness was compared with current design code provisions and numerical analysis results, and it agreed well with the numerical analysis results.