• Title/Summary/Keyword: damage condition

Search Result 2,006, Processing Time 0.03 seconds

A Study on the Improvement of Disaster and Safety Management for Local Cultural Heritages (지방문화재 재난안전관리 개선방안에 관한 연구)

  • Kim, Twe-Hwan;Kim, Jung-Gon;Been, Ju-Hee
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.3
    • /
    • pp.358-366
    • /
    • 2019
  • Purpose: This paper aims to clarify the problems and to examine the improvement methods by investigating the management condition of local-designated cultural property of which management is relatively poor in comparison with state-designated cultural heritage. Method: In order to grasp the management situation of the local-designated cultural heritage, a research on cultural heritage management situation and problems will be carried out with 35 cultual heritages in Goryeong-gun. Also, the improvement methods about the property type vulnerability on the basis of interview with cultual property managers, fire-fighting officers and civil servants, etc. Results: Local cultural heritages were investigated to be very vulnerable to the fire of wooden buildings, the theft of movable cultural heritages, and the effects of wind and water damage. It is because cultural heritages are scattered over wide areas fundamentally. As the result, it has difficulty in the patrols of police officers and fire fighters, and in the situation that it lacks disaster monitoring and CCTV for countermeasures to replace them, electronic security including fire hydrant, sensors, etc and fire extinguishing facilities and so on. It is difficult for local governments managing local-designated cultural heritages to enhance their management systems directly due to their lack of budget and manpower. Conclusion: In order to strengthen disaster and safety management system for the cultural heritages designated by local governments, they have to clarify disaster countermeasure task of fire fighting, police, and cultural heritage managers prepare their manuals, and systematize them through disaster drill mainly in local autonomous governments. Also, so as to establish a surveillance system every day, they have to enhance the community for local cultural heritage manage consisting of local volunteer fire departments, local voluntary disaster prevention organizations, volunteers, etc.

Analysis of Effects of Multiple Environmental Factors on Early Life-history for Growth and Stress Accumulation Using a Dynamic-state-dependent Model (동적상태의존모델을 이용하여 복합적 환경영향이 어류의 초기 생활사에 미치는 영향 분석)

  • Lee, Who-Seung
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.1
    • /
    • pp.49-62
    • /
    • 2019
  • Environmental changes can affect life-history traits, such as growth rate and reproduction, and organisms adapt on a given environmental condition to maximize ecological fitness. This study shows the effects of water temperature and dissolved oxygen level on early growth and accumulated damage in fish using a dynamic-state-dependent model. I have hypothesized that the level of foraging activity is related to growth and stress and so the optimal level can maximize reproductive success - ultimately, fitness. The critical temperature and dissolved oxygen (DO) is also defined as inducing the maximum growth rate at the level. So, the model predicts the highest growth rate at oxygen saturation and lower growth rate at lower or higher level of DO in water. Lower DO (i.e., hypoxia) causes slower growth rate through higher amount of accumulated stress whereas higher DO (i.e., hyperoxia) induces faster growth rate, but smaller body size. In addition, I show that there is lower impact when considering simple or independent environmental factors on environmental assessment. My findings suggest that multiple environmental factors as physiological ecology approach should be considered to improve impact assessment in environmental changes and a further study is needed to develop advanced assessment tools considering multiple environmental factors.

Extracorporeal Life Support in Acute Poisoning (급성 중독에서 체외순환보조장치의 적용)

  • Lee, Si Jin;Han, Gap Su;Lee, Eui Jung;Kim, Do Hyun;Park, Kyoung Yae;Lee, Ji Young;Kim, Su Jin;Lee, Sung Woo
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.16 no.2
    • /
    • pp.86-92
    • /
    • 2018
  • Purpose: Cardiovascular or respiratory complications of acute intoxication are the most common causes of mortality. Advanced cardiac life support (ACLS) or specific antidotes help manage these cardiac or respiratory complications in acute intoxication. On the other hand, some cases do not respond to ACLS or antidotes and they require some special treatment, such as extracorporeal life support (ECLS). ECLS will provide the chance of recovery from acute intoxication. This study examined the optimal timing of ECLS in acute intoxication cases. Methods: This paper is a brief report of a case series about ECLS in acute poisoning. The cases of ECLS were reviewed and the effects of ECLS on the blood pressure and serum lactate level of the patients were analyzed. Results: A total of four cases were reviewed; three of them were antihypertensive agent-induced shock, and one was respiratory failure after the inhalation of acid. The time range of ECLS application was 4.8-23.5 hours after toxic exposure. The causes of ECLS implementation were one for recurrent cardiac arrest, two for shock that did not respond to ACLS, and one for respiratory failure that did not respond to mechanical ventilator support. Three patients showed an improvement in blood pressure and serum lactate level and were discharged alive. In case 1, ECLS was stared at 23.5 hours post toxic exposure; the patient died due to refractory shock and multiple organ failure. Conclusion: The specific management of ECLS should be considered when a patient with acute intoxication does not recovery from shock or respiratory failure despite ACLS, antidote therapies, or mechanical ventilator support. ECLS improved the hemodynamic and ventilator condition in complicated poisoned patients. The early application of ECLS may improve the tissue perfusion state and outcomes of these patients before the toxic damage becomes irreversible.

A Study on Behavior of Post-integrated Abutment Bridge When Abutment and Bridge Decks are Jammed (교대 협착 발생 시 무조인트화 교량의 거동 분석 연구)

  • Park, Yang Heum;Nam, Moon S.;Jang, Il Young
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.3
    • /
    • pp.31-35
    • /
    • 2021
  • The expansion joints installed on the bridge for the accommodation of expansion and contraction of the supper structure are essential members of the bridge. However, the expansion joints are deteriorated over time and the waterproof function weakens, causing rainwater to penetrate and deteriorate the structure. In order to solve the traffic congestion caused by frequent replacement of the old expansion joints along with the deterioration of the structure, a post-integrated abutment bridge in which the existing expansion joints are removed and replaced with reinforced concrete link connection has been applied to highway bridges since 2016. After the post-integrated abutment method was applied, it was partially applied to bridges in which the superstructure and abutment were jammed. In this study, the causes of problems that may occur when the post-integrated abutment method is applied to the jammed bridge were analyzed numerically. It was analyzed that damage occurred in the link connection part. Based on the results of this study, the application condition for the post-integrated abutment method is reinforced as it is not possible to apply the post-integrated abutment method to bridges are already jammed.

A Study on the Risk of Halogen Lamp for Pigsty Heating and Fire Prevention (축사 난방용 할로겐램프의 위험성 및 화재 예방에 관한 연구)

  • Lee, Jae kyung;Seo, Seong Hyeon;Lee, Jae Wook
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.3
    • /
    • pp.553-564
    • /
    • 2021
  • This study analyzed the the risk of halogen lamp for pigsty heating and its fire prevention. Halogen lamps are used for keeping warm in pen because of their excellent economy and convenience. However, there is a high risk of fire due to poor safety management and exposure to animal movements. In fact, after exploring old pigsty and cattle shed, it was easy to confirm that they were exposed to fire risks. We noted this point and studied the possibility of fire by experiment due to combustible contact with halogen lamp and carelessness in use. The experiment was conducted under conditions similar to the actual use environment. After installing halogen lamps to the height used in actual pen, the temperature change was observed with infrared camera with straw, sawdust and rice husks on the floor. And assuming abnormal conditions, the experiment was also conducted under conditions the lamp dropped on the floor or combustible material came into contact with the glass tube inside the lamp. If halogen lamps were used in normal condition, there was no risk of fire. However, in abnormal use environments, smoke comes out or even ignited. Even if it is convenient for use or highly utilized, high risk of fire will require setting up fire prevention measures or regulation of use. Through in-depth fire investigation and research, we should promote the risk of fire and make efforts to prevent fire to minimize human life and property damage.

Study on the Brittle Crack Arrest Property for 9% Ni Steel by Duplex ESSO test (Duplex ESSO 시험법에 의한 9% Ni강 취성 균열정지 특성 연구)

  • Kim, Young Kyun;Oh, Byung Taek;Yang, Young Chul;Yoon, Ihn soo;Kim, Jae Hoon
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.6
    • /
    • pp.47-54
    • /
    • 2020
  • A brittle fracture is one of the source of structural damage and can bring a fatal accident. The inner shell of LNG storage tank should be designed and applied to construction by ensure that no brittle crack will occur under -162℃ condition. In point of view of fracture mechanics brittle fracture in the structure could be referred as crack initiation and crack arrest. It should be designed no crack initiation. However, in the unlikely event of a brittle fracture occurring, a back-up function of arresting the brittle crack should be included for the design. In this paper investigated the characteristics of 9% Ni steel thick plates of having a capability of arresting brittle cracks under the thickness of 33 mm, 37mm, 40 mm. First, charpy test has performed to evaluate the fundamental brittle impact fracture property of 9% Ni steel under the temperature of 24℃, -162℃ and -196℃. In addition, Duplex ESSO tests were also performed under -196℃ to evaluate the capability of crack arrest for 9% Ni steel. From the experiments results, it was confirmed that all the thickness of 9% Ni steel plates exhibits sufficient brittle crack arrest fracture toughness for the application of LNG storage tank as a inner shell.

Seismic Fragility of Bridge Considering Foundation and Soil Structure Interaction (교량기초 종류 및 지반-구조물 상호작용을 고려한 지진취약도 분석)

  • Kim, Sun-Jae;An, Hyo-Joon;Song, Ki-il
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.129-137
    • /
    • 2020
  • In performing the structural analysis, the foundation is considered to be a fixed end as a plastic hinge model. In this study, the displacements of the foundation, pier, and shoe were compared when the foundation modeled as a fixed end, a shallow foundation constructed on bedrock of 2m depth, and a pile foundation constructed in the 10m to 20m depth of bedrock. The shear force was also compared, and the probability of damage was calculated and compared for the critical condition. When calculated as a fixed end, the displacement of the foundation converged to 0mm, but the shallow foundation built on the bedrock with a depth of 2m caused relatively displacement, and the pile foundation constructed to contact the bedrock with a depth of 18m caused a larger displacement. In addition, it was analyzed that the displacement of the foundation, which is the lower structure, affects the displacement of the super structure, but the difference in shear force applied to the foundation was insignificant in the three cases. There was no difference between the shallow foundation and the pile foundation in the influence on the displacement of the top of the pier, but there was a big difference from the analysis assuming as a fixed end.

Diagnosis and Visualization of Intracranial Hemorrhage on Computed Tomography Images Using EfficientNet-based Model (전산화 단층 촬영(Computed tomography, CT) 이미지에 대한 EfficientNet 기반 두개내출혈 진단 및 가시화 모델 개발)

  • Youn, Yebin;Kim, Mingeon;Kim, Jiho;Kang, Bongkeun;Kim, Ghootae
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.4
    • /
    • pp.150-158
    • /
    • 2021
  • Intracranial hemorrhage (ICH) refers to acute bleeding inside the intracranial vault. Not only does this devastating disease record a very high mortality rate, but it can also cause serious chronic impairment of sensory, motor, and cognitive functions. Therefore, a prompt and professional diagnosis of the disease is highly critical. Noninvasive brain imaging data are essential for clinicians to efficiently diagnose the locus of brain lesion, volume of bleeding, and subsequent cortical damage, and to take clinical interventions. In particular, computed tomography (CT) images are used most often for the diagnosis of ICH. In order to diagnose ICH through CT images, not only medical specialists with a sufficient number of diagnosis experiences are required, but even when this condition is met, there are many cases where bleeding cannot be successfully detected due to factors such as low signal ratio and artifacts of the image itself. In addition, discrepancies between interpretations or even misinterpretations might exist causing critical clinical consequences. To resolve these clinical problems, we developed a diagnostic model predicting intracranial bleeding and its subtypes (intraparenchymal, intraventricular, subarachnoid, subdural, and epidural) by applying deep learning algorithms to CT images. We also constructed a visualization tool highlighting important regions in a CT image for predicting ICH. Specifically, 1) 27,758 CT brain images from RSNA were pre-processed to minimize the computational load. 2) Three different CNN-based models (ResNet, EfficientNet-B2, and EfficientNet-B7) were trained based on a training image data set. 3) Diagnosis performance of each of the three models was evaluated based on an independent test image data set: As a result of the model comparison, EfficientNet-B7's performance (classification accuracy = 91%) was a way greater than the other models. 4) Finally, based on the result of EfficientNet-B7, we visualized the lesions of internal bleeding using the Grad-CAM. Our research suggests that artificial intelligence-based diagnostic systems can help diagnose and treat brain diseases resolving various problems in clinical situations.

An Experimental Study on the Applicability of UAV for the Analysis of Factors Influencing Rural Environment - Focusing on Photovoltaic Facilities and Vacant House in Galsan-Myeon, Hongseong-gun - (농촌 공간 환경영향요인 분석을 위한 무인항공기 적용 가능성에 관한 실험적 연구 - 홍성군 갈산면의 태양광 발전시설과 빈집을 중심으로 -)

  • An, Phil-Gyun;Eom, Seong-Jun;Kim, Su-Yeon;Kim, Young-Gyun
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.24 no.1
    • /
    • pp.9-17
    • /
    • 2022
  • Rural spaces are increasingly valuable as areas for introducing renewable energy infrastructure to achieve carbon neutrality. Rural areas are the living grounds of rural residents, and the balance of conservation and development for rural areas is important for the introduction of reasonable facilities. In order to maintain a balance between development and preservation and to introduce reasonable renewable energy facilities, it is necessary to develop a current status survey and an effective survey method to utilize a space capable of introducing renewable energy facilities such as idle land and vacant houses. Therefore, this study was conducted to verify the readability using an unmanned aerial vehicle, and the main results are as follows. The detection of photovoltaic power generation facilities using unmanned aerial vehicles was effective in analyzing the location and area of photovoltaic panels located on the roofs of buildings, and it was possible to calculate the expected power generation by region through the area calculation of photovoltaic panels. The vacant house detection can be used to select an investigation target for an vacant house condition survey as it can identify damage to buildings that are expected to be empty houses, management status, and electricity supply facilities through aerial photos. It is judged that the unmanned aerial vehicle detection capability can be utilized as a method to improve the efficiency of investigation and supplement the data related to solar power generation facilities and vacant houses provided by public institutions. Although this study detected the status of solar power generation facilities and vacant houses through high-resolution aerial image analysis, as a follow-up study, automatic measurement methods using the temperature difference of solar power generation facilities and general characteristics of vacant houses that can be read from the air were investigated. If the deriving research is carried out, it is judged that it will be possible to contribute to the improvement of the accuracy of the detection result using the unmanned aerial vehicle and the expansion of the application range.

Evaluation Study of Blast Resistance and Structural Factors in the Explosive Simple Storage by Numerical Analysis (수치해석을 통한 화약류 간이저장소의 방폭성 및 구조인자 평가연구)

  • Jung, Seung-Won;Kim, Jung-Gyu;Kim, Jun-Ha;Kim, Nam-Soo;Kim, Jong-Gwan
    • Tunnel and Underground Space
    • /
    • v.32 no.2
    • /
    • pp.160-172
    • /
    • 2022
  • The design regulations for simple explosive storage in Korea only stipulate standards for the materials and thickness of the wall of the structure because the amount of explosives that can be stored is small. There is concern about secondary damage during an internal explosion in a simple storage facility, and it is necessary to reexamine the current standards. The numerical analysis for the TNT 15 kg explosion inside the simple storage was carried out by setting the factors using the robust experimental design method. The displacement of the structure generated under the same time condition was analyzed, and the contribution was evaluated. The contribution of concrete thickness was the highest, and the contribution of concrete strength and rebar arrangement was lower than that of concrete thickness. The reinforcement diameter contributed extremely little to the displacement. The structural standards of the simple storage that are currently applied are insufficient on blast resistance, and it is necessary to present new design standards. Therefore, the design factor to be applied later analysis and actual experiments were taken into consideration. For the design variables, the thickness of the concrete was 15 cm considering the displacement, the concrete strength was selected as general concrete considering the inlet discharge pressure, the factor with the lowest average displacement was selected for the reinforcement arrangement and the diameter of the reinforcement, the factor with the smallest level was selected in consideration of economic feasibility because the difference in displacement was low.