• Title/Summary/Keyword: damage condition

Search Result 2,006, Processing Time 0.026 seconds

Crack Monitoring of RC beam using Surface Conductive Crack Detection Patterns based on Parallel Resistance Network (병렬저항회로에 기반한 표면 전도성 균열감지패턴을 사용한 콘크리트 휨 부재의 균열 감지 )

  • Kyung-Joon Shin;Do-Keun Lee;Jae-Heon Hong;Dong-Chan Shin;Jong-Hyun Chae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.5
    • /
    • pp.67-74
    • /
    • 2023
  • A large number of concrete structures are built and used around the world. To ensure their safe and continuous use, these structures require constant inspection and maintenance. While man-powered inspection and maintenance techniques are efficient, they can only provide intermittent status checks at the time of on-site inspection. Therefore, there is a growing need for a system that can continuously monitor the condition of the structure. A study was conducted to detect cracks and damage by installing a conductive coating on the surface of a concrete structure. A parallel resistance pattern that can monitor the occurrence and progression of cracks was developed by reflecting the structural characteristics of concrete structure. An empirical study was conducted to veryfy the application of the proposed method. The crack detection pattern was installed on the reinforced concrete beams, and the crack monitoring method was verified through applying a load on the beams.

Analysis of outflow reduction effect of bioretention in small watersheds during short-term rainfall (단기강우 시 소유역내 식생저류지의 유출량 저감성능 분석)

  • Kim, Jaemoon;Baek, Jongseok;Kim, Byungsung;Kwon, Soonchul
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.12
    • /
    • pp.855-869
    • /
    • 2023
  • Low Impact Development (LID) technology has been attracting attention as a countermeasure to solve frequent flood damage in urban areas. LID involves recovery of the natural circulation system based on infiltration and storage capacity at the site of rainfall runoff, to protect the aquatic ecosystem from the effects of urbanization. Bioretention as an element of LID technology reduces outflow through storage and infiltration of storm water runoff, and minimizes the effects of non-point pollutants. Although LIDs are being studied extensively, the amount of quantitative research on small watersheds with bioretention has been inadequate. In this study, a bioretention model was constructed in a small watershed using Korea-Low Impact Development Model (K-LIDM), which was conducted quantitative hydrologic analysis. We anticipate that the results of the analysis will be used as reference data for future bioretention research related to watershed characteristics, vegetation type, and soil condition.

Research on Improving the Performance of YOLO-Based Object Detection Models for Smoke and Flames from Different Materials (다양한 재료에서 발생되는 연기 및 불꽃에 대한 YOLO 기반 객체 탐지 모델 성능 개선에 관한 연구 )

  • Heejun Kwon;Bohee Lee;Haiyoung Jung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.3
    • /
    • pp.261-273
    • /
    • 2024
  • This paper is an experimental study on the improvement of smoke and flame detection from different materials with YOLO. For the study, images of fires occurring in various materials were collected through an open dataset, and experiments were conducted by changing the main factors affecting the performance of the fire object detection model, such as the bounding box, polygon, and data augmentation of the collected image open dataset during data preprocessing. To evaluate the model performance, we calculated the values of precision, recall, F1Score, mAP, and FPS for each condition, and compared the performance of each model based on these values. We also analyzed the changes in model performance due to the data preprocessing method to derive the conditions that have the greatest impact on improving the performance of the fire object detection model. The experimental results showed that for the fire object detection model using the YOLOv5s6.0 model, data augmentation that can change the color of the flame, such as saturation, brightness, and exposure, is most effective in improving the performance of the fire object detection model. The real-time fire object detection model developed in this study can be applied to equipment such as existing CCTV, and it is believed that it can contribute to minimizing fire damage by enabling early detection of fires occurring in various materials.

Evaluation of Wind load Safety for Single G-type Greenhouse Using Korean Design Standard (건축구조기준을 활용한 농가지도형 G형 비닐하우스의 풍하중 안전성 평가)

  • Lee, Woogeun;Shin, Kyungjae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.66 no.1
    • /
    • pp.39-48
    • /
    • 2024
  • Plastic greenhouses are simple structures consisting of lightweight materials such as steel pipes and polyvinyl chloride. However, serious damage occurs due to heavy winds and typhoon every year. To prevent a collapse of structural members, the Ministry of Agriculture and Rural Development has distributed plans and specifications for disaster-resistant standards. Despite these efforts, more than 50% of greenhouses still do not satisfy the disaster-resistant standards. Among the greenhouses that do not meet these standards, 85% are single-span greenhouses proposed 20 years ago. Consequently, there is a need to evaluate the safety of wind loads for the single-span greenhouse. Unfortunately, there are no design specifications for the greenhouses under wind loads. Therefore, a Korean design standard (KDS) has been utilized. KDS is defined with reference to wind speeds occurring once every 500 years, raising concerns about potential overdesign when considering the durability of plastic greenhouses. To address this, the modified wind load, considering the durability of the plastic greenhouse, was calculated, and a safety evaluation was conducted for sigle G-type plastic greenhouse. It was observed that the moment acting on the windward surface was substantial, and there was a risk of the foundation being pulled out if the basic wind speed exceeded 32 m/s. In terms of the combination strength ratio, it was less than 1.0 only on the leeward side when the basic wind speed was 24 m/s and 26 m/s. However, in all other cases, it exceeded 1.0, indicating an unsafe condition and highlighting the necessity for reinforcement.

Comparison of Vibration Characteristics of Cargo Bikes on General Roads and Bicycle Roads (일반도로와 자전거도로에서의 카고바이크 화물 적재함 진동 특성 비교)

  • Dong Yul Kim;Myenog Guk Yu;Heng Suk Lee;Sang Min Kim
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.29 no.3
    • /
    • pp.175-179
    • /
    • 2023
  • This paper analyzes the vibration characteristics within the cargo compartment of a three-wheeled cargo bike when used on both regular roads and dedicated bicycle lanes. When cargo is loaded into the cargo compartment of a cargo bike and driven on the road, the shocks and vibrations transmitted from the ground can potentially affect the transported goods and even lead to product damage. As the vibration characteristics applied to the cargo compartment may vary depending on the condition of the road, vibration sensors were attached to the cargo bike's cargo compartment for data collection during operation on different road types. According to KS T ISO 13355 standards, the cargo bike can withstand vibrations within the range of 10 Hz to 60 Hz when operating on both bicycle lanes and regular roads. However, it is observed that there are peaks exceeding the profile in the frequency range of 3-6 Hz. In the 70-200 Hz range, the profile is exceeded on both regular roads and bicycle lanes, with a tendency for higher exceedance on bicycle lanes. The Grms value within the frequency range of KS T ISO 13355 is 5.926 m/s2 (0.604 Grms). When operating on bicycle lanes with cargo, the Peak envelope optimization PSD value is 6.553 Grms, while on bicycle lanes, it is 7.708 Grms, indicating a difference of at least tenfold.

The ameliorating role of sofosbuvir and daclatasvir on thioacetamide-induced kidney injury in adult albino rats

  • Ahmed H. Moustafa;Heba F. Pasha;Manar A. Abas;Adel M. Aboregela
    • Anatomy and Cell Biology
    • /
    • v.56 no.1
    • /
    • pp.109-121
    • /
    • 2023
  • Thioacetamide (TAA) exposure and hepatitis C virus infection are usually associated with renal dysfunction. Sofosbuvir (SFV) and daclatasvir (DAC) drugs combination has great value in the treatment of hepatitis C. The study aimed to identify the nephrotoxic effects of TAA and to evaluate the ameliorative role of SFV and DAC in this condition. Forty-eight adult male albino rats were divided into eight groups and received saline (control), SFV, DAC, SFV+DAC, TAA, TAA+SFV, TAA+DAC and TAA+SFV+DAC for eight weeks. Kidney and blood samples were retrieved and processed for histological (Hematoxylin and Eosin and Masson's trichrome), immunohistochemical (α-smooth muscle actin), and biochemical analysis (urea, creatinine, total protein, albumin, malondialdehyde, reduced glutathione, superoxide dismutase, and tumor necrosis factor-α). Examination revealed marked destruction of renal tubules on exposure to TAA with either hypertrophy or atrophy of glomeruli, increase in collagen deposition, and wide expression of α-smooth muscle actin. Also, significant disturbance in kidney functions, oxidative stress markers, and tumor necrosis factor-α. Supplementation with either SFV or DAC produced mild improvement in the tissue and laboratory markers. Moreover, the combination of both drugs greatly refined the pathology induced by TAA at the cellular and laboratory levels. However, there are still significant differences when compared to the control. In conclusion, SFV and DAC combination partially but greatly ameliorated the renal damage induced by TAA which might be enhanced with further supplementations to give new hope for those with nephropathy associated with hepatitis.

Nondestructive detection of crack density in ultra-high performance concrete using multiple ultrasound measurements: Evidence of microstructural change

  • Seungo Baek;Bada Lee;Jeong Hoon Rhee;Yejin Kim;Hyoeun Kim;Seung Kwan Hong;Goangseup Zi;Gun Kim;Tae Sup Yun
    • Computers and Concrete
    • /
    • v.33 no.4
    • /
    • pp.399-407
    • /
    • 2024
  • This study nondestructively examined the evolution of crack density in ultra-high performance concrete (UHPC) upon cyclic loading. Uniaxial compression was repeatedly applied to the cylindrical specimens at levels corresponding to 32% and 53% of the maximum load-bearing capacity, each at a steady strain rate. At each stage, both P-wave and S-wave velocities were measured in the absence of the applied load. In particular, the continuous monitoring of P-wave velocity from the first loading prior to the second loading allowed real-time observation of the strengthening effect during loading and the recovery effect afterwards. Increasing the number of cycles resulted in the reduction of both elastic wave velocities and Young's modulus, along with a slight rise in Poisson's ratio in both tested cases. The computed crack density showed a monotonically increasing trend with repeated loading, more significant at 53% than at 32% loading. Furthermore, the spatial distribution of the crack density along the height was achieved, validating the directional dependency of microcracking development. This study demonstrated the capability of the crack density to capture the evolution of microcracks in UHPC under cyclic loading condition, as an early-stage damage indicator.

Imaging of Umbilical Venous Catheter-Related Hepatic Complications in Neonates (신생아의 제대 정맥 카테터와 관련된 간 합병증의 영상 소견)

  • Min Ju Kim;So-Young Yoo;Tae Yeon Jeon;Ji Hye Kim;Yu Jin Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.3
    • /
    • pp.586-595
    • /
    • 2023
  • An umbilical venous catheter (UVC) is commonly placed for central venous access in preterm or critically ill full-term neonates to provide total parenteral nutrition (TPN) and medication. However, UVCs can result in complications, including infection, portal vein thrombosis, and hepatic tissue injury. The inadvertent administration of hypertonic fluid through a malpositioned UVC can also cause hepatic parenchymal damage with mass-like fluid collection that simulates a tumorous condition during imaging. Ultrasonography and radiographic examinations play an essential role in detecting UVC-related complications. This pictorial essay aims to present the imaging findings of UVC-related hepatic complications in neonates.

The Non-destructive Inspection Using Infrared Thermal Technique on Reinforced Slopes by Shotcrete (적외선 열화상을 이용한 숏크리트 보강사면의 비파괴점검)

  • Shin, Chang-Gun;Lee, Song;Ahn, Sang-Ro
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.1
    • /
    • pp.95-102
    • /
    • 2007
  • It needs to Prevent damage as aging shotcrete itself exists as a dangerous component to comuting vehicles or infrastructure due to scaling, spaling, and loosening. However, it is hard to make an approach owing to a steep slope and high work, and there has been indicated a limit that it is difficult to grasp the internal condition of shotcrete on the surface. This study aimed to research internal defects that cannot be observed from the surface, by measuring a subtle thermal transfer on the shotcrete surface by using infrared thermography for overcoming such a technical limit. As a result of conducting an inspection through an analysis on measured data and fieldwork using an endoscope camera, it was impossible to accurately determine the wet part because of an excessive coating of shotcrete, yet, This study is proposed effictively extract a void part of the inside with non-destructive and non-touching method.

The Evaluation of Surface Scaling and Resistance of Concrete to Frost Deterioration with Freezing-Thawing Action by Salt Water (염화물이 함유된 동결수의 동결융해 작용에 따른 콘크리트의 내동해성과 표면열화 평가)

  • Kim, Gyu-Yong;Kim, Moo-Han;Cho, Bong-Suk;Lee, Seung-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.6
    • /
    • pp.143-151
    • /
    • 2007
  • This study presents the experimental results of frost durability including resistance to freezing-thawing and surface scaling of concrete. Mixing design was proportioned with the various water-binder ratio between 0.37 and 0.47 and three different binder compositions corresponding to Type I cement without any supplementary cementitious materials(OPC), Type II cement with 50% blast-furnace slag replacement(BFS50), and ternary cement with Type III cement, 15% fly ash, and 35% slag replacement (BFS35%+FA15%). Test results showed that the mixing design with BFS50% and BFS35%+FA15% exhibited higher durability factor than that made with OPC only. Finally, the use of blend cement containing slag can be used effectively in terms of frost durability of the concrete exposed to severe condition under coastal environment like as flying salt, sea water spray, etc.