흙댐의 누수구역 판별을 위한 온도 모니터링 자료의 해석 (Analysis of temperature monitoring data for leakage detection of earth dam)

  • 오석훈;서백수
    • 산업기술연구
    • /
    • 제28권B호
    • /
    • pp.39-45
    • /
    • 2008
  • Temperature variation according to space and time on the inner parts of engineering constructions(e.g.: dam, slope) can be a basic information for diagnosing their safety problem. In general, as constructions become superannuated, structural deformation(e.g.: cracks, defects) could be occurred by various factors. Seepage or leakage of water through these cracks or defects in old dams will directly cause temperature anomaly. Groundwater level also can be easily observed by abrupt change of temperature on the level. This study shows that the position of seepage or leakage in dam body can be detected by multi-channel temperature monitoring using thermal line sensor. For this, diverse temperature monitoring experiments for a leakage physical model were performed in the laboratory. In field application of an old earth fill dam, temperature variations for water depth and for inner parts of boreholes located at downstream slope were measured. Temperature monitoring results for a long time at the bottom of downstream slope of the dam showed the possibility that temperature monitoring can provide the synthetic information about flowing path and quantity of seepage of leakage in dam body.

  • PDF

콘크리트 표면차수벽형 석괴댐(CFRD)의 누수특성에 관한 사례연구 (A Case Study on the Leakage in Concrete Face Rockfill Dam)

  • 방돈석;신창건;이강용;안상로
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.197-202
    • /
    • 2003
  • The leakage quantity through concrete facing of Concrete Face Rockfill Dam(CFRD) is very small due to its low permeability of intact concrete. Even though the concrete facing is well designed and constructed, fine cracks can be generated due to effects of thermal and drying shrinkage. Therefore, it can be said that the leakage from the CFRD is subjected to not permeability of intact concrete but poor joints, cracks and foundation rocks. The Safety of a dam on leakage was evaluated based on the comparison between apparent permeability estimated and leakage quantity measured. The above method can be concluded to give a good direction for the evaluation of safety on CFRD in maintenance aspects as design and construction technology is improved with the accumulation of leakage data.

  • PDF

계측자료 분석에 의한 필댐의 장기 침투거동 연구 (A Study on Long-Term Seepage Behaviour of Fill Dam by the Monitoring Data Analysis)

  • 정규정;이송
    • 한국지반환경공학회 논문집
    • /
    • 제11권9호
    • /
    • pp.15-25
    • /
    • 2010
  • 본 연구는 중앙심벽형 필댐인 주암댐과 임하댐을 대상으로 자동계측에 의해 연속적으로 생산되는 침투수량 계측자료에 대하여 분석을 통하여 필댐 고유의 특성에 따른 장기 침투특성과 댐의 안전관리 방법을 검토하고자 하였다. 필댐의 침투수량 계측값에는 내재 하는 강우 성분 등의 외부 요인의 영향으로 직접적으로 이상 누수의 발생을 검출하는 것은 어렵다. 이 때문에, 종래 저수위와 강우량을 고려하는 중회귀분석 등에 의해 누수량을 추정하는 방법이 적용되어 왔으나, 강우 성분의 추정 오차가 상대적으로 크고 정밀도가 불량한 것으로 알려졌다. 본 논문에서는 강우 성분의 분리해석을 통해 직접적으로 강우 성분에 영향을 받지 않는 저수지 수위에 연동하는 댐별 침투거동을 평가함과 아울러 분석대상 댐의 지형적, 수리지질학적 특성을 반영한 3차원 수치해석을 실시하여 계측 침투수량 자료와 비교하였다. 2개 대상댐의 침투거동은 각각의 고유한 특징을 가지고 있으며, 장기적으로 침투수량의 감소를 보여주고 있어 안정적인 상태로 나타났다. 또한, 수문곡선분리법은 침투수 안전관리 방법으로 적용가능한 것으로 판단되었다.

Validation of a new magnetometric survey for mapping 3D subsurface leakage paths

  • Park, DongSoon;Jessop, Mike L.
    • Geosciences Journal
    • /
    • 제22권6호
    • /
    • pp.891-902
    • /
    • 2018
  • Techniques for more reliable detection of 3D subsurface flow paths are highly important for most water-related geotechnical projects. In this case study, a magnetometric resistivity method with a new approach and state-of-the-art technology ("Willowstick survey") was applied to the testbed dam (YD dam) site, and its applicability was validated by geotechnical investigation techniques including borehole drilling and sampling, Lugeon test, flow direction and velocity test, and seismic tomography. In addition to the magnetometric survey, a 3D electrical resistivity survey was performed independently and the results were compared and discussed. The electrical resistivity survey was effective in detecting groundwater levels, but it was limited in mapping leakage paths. On the other hand, the Willowstick magnetometric survey effectively detected geologic weaknesses (e.g., fault fracture) and potential leakage paths of the dam site foundation rocks. The results of this research are expected to be effective for water infrastructures where leakage is an important issue.

댐 침투수 탐지를 위한 멀티 채널 온도 모니터링 연구 (A Study on multi-channel temperature monitoring for the detection of leakage or seepage in dam body)

  • 오석훈;김중열;박한규;김형수;김유성
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1211-1218
    • /
    • 2005
  • Temperature variation according to space and time on the inner parts of engineering constructions(e.g.: dam, slope) can be a basic information for diagnosing their safety problem. In general, as constructions become superannuated, structural deformation(e.g.: cracks, defects) could be occurred by various factors. Seepage or leakage of water through these cracks or defects in old dams will directly cause temperature anomaly. Groundwater level also can be easily observed by abrupt change of temperature on the level. This study shows that the position of seepage or leakage in dam body can be detected by multi-channel temperature monitoring using thermal line sensor. For this, diverse temperature monitoring experiments for a leakage physical model were performed in the laboratory. In field application of an old dam, temperature variations for water depth and for inner parts of boreholes located at downstream slope were measured. Temperature monitoring results for a long time at the bottom of downstream slope of the dam showed the possibility that temperature monitoring can provide the synthetic information about flowing path and quantity of seepage of leakage in dam body.

  • PDF

콤팩션 그라우팅에 의한 흙댐의 누수복원 공사효과 분석 (The Effect of Remedial Works to Control the Leakage Problem in Earth Fill Dam by Compaction Grouting)

  • 천병식;이용재;정하익
    • 한국지반공학회논문집
    • /
    • 제22권11호
    • /
    • pp.13-23
    • /
    • 2006
  • 국내의 흙댐 중에서 댐코아에 함몰 및 누수가 발생한 사례가 있었는데 콤팩션그라우팅에 의하여 댐코아의 손상부위를 복원하였다. 본 연구에서는 콤팩션그라우팅에 의한 복원공사전 공사중 및 공사후에 실내 및 현장시험을 통하여 콤팩션그라우팅 효과를 평가하였다. 콤팩션그라우팅공사와 더불어 정밀한 현장조사 및 지구물리탐사를 진행하였다. 콤팩션그라우팅공사는 2000년 6월 16일부터 8월 24일까지 수행되었다. 콤팩션그라우팅공사에 의한 댐복원후에 댐코아의 누수가 감소되었다. 콤팩션그라우팅공사가 손상된 댐을 복원하는데 효과가 큰 것으로 평가되었다. 콤팩션그라우팅공법의 적용에 의하여 댐코아의 느슨하고 공간이 있는 부분을 채우게 되었고 그라우팅 처리전에 비하여 누수량이 약 96% 정도 격감되었다.

방조제 누수지점 탐지를 위한 SP및 단극배열 전기비저항탐사의 적용 (Application of SP and Pole-pole Array Electrical Resistivity Surveys to the Seawater Leakage Problem of the Embankment)

  • 송성호;이규상;김진호;권병두
    • 자원환경지질
    • /
    • 제33권5호
    • /
    • pp.417-424
    • /
    • 2000
  • We applied SP monitoring and resistivity surveys using the pole-pole electrode array to seawater leakage problems in the Youngsan estuary dam and the Eoeun embankment to estimate and detect the zone of seawater leakage. The embankment is generally affected by tidal variation and has low resistivity characteristics due to the high saturation of seawater. For this reason, SP monitoring and the pole-pole array resistivity surveys, which are relatively more effective to the conductive media, were carried out to delineate the leakage zones of sea water through the embankment. We checked out electrical conductivity (EC) and temperature variations along the inner part of Youngsan estuary dam to detect the zone of seawater leakage and found that the measured EC value agreed to that of seawater in the leakage zone and the temperature was lower than that of the vicinity of leakage zone. SP monitoring results were coincided with tidal variations at each embankment. At the leakage zones in the Youngsan estuary dam and the Eoeun embankment, SP anomalies are in the range of -60~-85 mV and -20~-50 mV, respectively, and true resistivity values obtained by 2-D inversion are 3~15 ohm-m and below 0.3 ohm-m, respectively. Both SP monitoring and the pole-pole array resistivity method are found to be quite effective for investigation of seawater leakage zones in the embankment.

  • PDF

필댐의 안정성 해석 연구 (II) (A STUDY ON THE SAFETY ANALYSIS OF ROCK FILL DAM (2))

  • 손호웅;이대근
    • 지구물리
    • /
    • 제6권3호
    • /
    • pp.189-207
    • /
    • 2003
  • 경북 청도군 소재 운문댐의 안전진단을 목적으로 지반조사 및 계측자료의 분석이 수행되었다 특히 운문댐은 1998년에 차례에 걸쳐 댐의 정상부에 함몰현상이 발생되었으며 이러한 함몰현상이 대해 많은 조사가 이루어졌으며 이에 따라 CGS보강공법을 2000년에 시행하였다 댐의 함몰현상의 메카니즘에 대해 많은 의견이 있으나 누수에 의한 내부침식이 가장 유력하다 필댐에 있어서의 과대누수는 댐의 안정성의 평가하는데 가장 중요한 변수로 작용 하므로 토질시험 계측자료 및 시추자료를 통한 댐체의 누수 및 거동분석을 수행하였다 자료들을 종합해 본 결과 부실시공 댐의 응력전이 수압할렬의 가능성 누수 취약대 등과 같은 댐의 거동에 대한 여러 가지 정보를 얻을 수 있었다 또한 토질시험에서 코아재료의 적합성에 문제가 있었음을 발견하였다 댐 제체에서도 연약대가 발견되었 으며 여수로 근접한 부분에서 누수의 가능성이 높은 것으로 나타났다 거동분석에서는 댐 코아의 수압할렬이나 응력전이에 의한 손상이나 유로의 가능성도 배제할 수 없었다

  • PDF

3차원 댐구조가 전기비저항 자료에 미치는 영향 (3D Effect of Embankment Dam Geometry to Resistivity Data)

  • 조인기;이근수;강혜진
    • 지구물리와물리탐사
    • /
    • 제13권4호
    • /
    • pp.397-406
    • /
    • 2010
  • 전기비저항 탐사법은 저수지 누수구간 탐지에 매우 효과적이고 실질적인 물리탐사법이다. 일반적으로 저수지 제체의 마루에서 수행되는 전기비저항 탐사는 저수지가 2차원 구조를 갖고 있다고 가정한다. 하지만 저수지 제체에서 얻어지는 전기비저항 탐사자료는 저수지의 3차원 지형에 의해 크게 영향을 받는다. 본 연구에서는 유한요소법을 사용하는 3차원 전기비저항 탐사 모델링 프로그램을 통하여 저수지의 3차원 구조와 저수지 수위의 변화가 전기비저항 탐사자료에 미치는 영향을 평가하였다. 또한 측선의 위치에 따른 전기비저항 탐사자료를 비교하였으며, 지형보정 기법을 개발하였다. 마지막으로 누수구간이 존재하는 제체에 대한 3차원 모델링 자료에 대하여 2.5차원 역산을 수행하여 2차원 전기비저항 탐사법을 이용한 누수구간 탐지의 가능성을 분석하였다.

흙댐의 누수구역 판별을 위한 물리탐사와 온도 모니터링 자료의 해석 (An Analysis of Geophysical and Temperature Monitoring Data for Leakage Detection of Earth Dam)

  • 오석훈;서백수;김중열
    • 한국지구과학회지
    • /
    • 제31권6호
    • /
    • pp.563-572
    • /
    • 2010
  • 흙댐에서의 누수 구역을 판별하기 위해 다채널 연속 온도 모니터링을 수행하고 이를 검증하기 위해 전기비저항 물리탐사를 함께 수행하였다. 일반적으로 댐이나 사면과 같은 인공구조물의 내부는 시간과 위치에 따라 상이한 온도 분포를 갖는 것으로 여겨진다. 이와 같은 분포는 구조물의 안전성을 판단하는 데 매우 중요한 기본 자료로 이용될 수 있으며, 특히 댐 구조물의 경우 과도 침투수나 누수에 의한 위험 대역을 파악할 수 있는 기술로 이용될 수 있다. 그러나 기존의 온도 측정 방식은 대형 구조물의 온도를 연속적으로 동시에 측정할 수 없는 단점을 가지고 있다. 본 연구에서는 이를 극복한 새로운 온도 모니터링 장비를 이용하여 댐의 상부 및 하부에 걸쳐, 여러 지점에서 동시에 온도 분포를 측정하였으며, 실내 시험을 통해 누수 대역이 온도 분포의 이상을 충분히 반영하고 있음을 관측하였다. 또한 대상 댐의 전 구역에 걸쳐 전기비저항 조사를 수행한 결과와 온도 모니터링 자료를 비교 분석하여 누수구역의 판별력을 높일 수 있는 방법을 제시하고자 하였다.