• 제목/요약/키워드: cyclone incinerator

검색결과 9건 처리시간 0.023초

바이오 가스 소각용 저공해 사이클론 소각기 개발을 위한 수치 해석적 연구 (Numerical Study for the Design of Biogas-fired Low Emission Cyclone Incinerator)

  • 전영남;김시욱;백원석
    • 한국대기환경학회지
    • /
    • 제18권5호
    • /
    • pp.401-410
    • /
    • 2002
  • Concerns for energy conservation, environmental pollution, and the fact that organic wastes account for a major portion of our waste materials, have created the interest of biogas, which usually contains about 60 to 70 percent methane, 30 to 40 percent carbon dioxide, and other gases, including ammonia, hydrogen sulfide, mercaptans and other noxious gases. Cyclone combustors are used for homing a wide range of fuels such as low calorific value gas, waste water, sludge. coal, etc. The 3-dimensional swirling flow, combustion and emission in a tangential inlet cyclone incinerator under different inlet conditions are simulated using a standard k-s turbulence model and ESCRS (Extended Simple Chemically-Reacting System) model. The commercial code Phoenics Ver.3.4 was used for the present work. The main parameters considered in this work are inlet velocity and air to fuel ratio. The results showed that the change of operating conditions had an influence on the shape and size of recirculation zones, mixture fraction and axial velocity which are important factors for combustion efficiency and emission behavior. The application of this kind of computer program seams to be promising as a potential tool for the optimum design of a cyclone combustor with low emission.

산업폐기물 소각시설에서 폐기물 유형에 따른 입자상물질의 배출특성 (Emission Characterization of Particulate Matters According to the Types of Wastes from Industrial Waste Incinerator)

  • 박정호;서정민;조정구;류재용;한성종
    • 한국환경과학회지
    • /
    • 제16권11호
    • /
    • pp.1225-1230
    • /
    • 2007
  • The emissions characteristics of particulate matters(PM) according to the types of wastes from industrial waste incinerator of 800 kg/hr treatment capacity were investigated. For this study, the incinerate waste are as follows; waste resin, waste wood, waste urethane, waste gunny, and waste paper. The particulate samples were collected to be emitted in stack and air pollution control(both cyclone and bag filter). In stack, the concentrations of PM were in the range of 2.61 to $26.51 mg/Sm^3$ and the major chemical species were C, Si, Cl, K, Na, Ca in all the wastes. In cyclone fly ash, the mean content of heavy metal were in the order of Fe > Zn > Pb > Cu > Mn > Cr > Ni > Cd > As > Hg and the heavy metal content of waste resin were Zn 34,197.5 mg/kg, Fe 27,587.6 mg/kg, Pb 6,055.8 mg/kg, respectively. In bag filter fly ash, the mean content of heavy metal were in the order of Zn > Pb > Fe > Cu > Mn > Cd > Cr > Ni > As > Hg and the heavy metal content of waste wood were Pb 36,405.2 mg/kg, Fe 15,762.9 mg/kg, Cu 9,989.5 mg/kg, Cd 2,230.1 mg/kg, respectively. Comparing the heavy metal content of both cyclone and bag filter, in cyclone, the Cr, Fe, Ni content were higher than in bag filter and the Cd, Cu, Hg content were lower than in bag filter.

슬러지용 소형 사이클론 소각 시스템의 연소특성에 대한 연구 (A Study on the Combustion Characteristics of the Small Scale Cyclone Incinerate System for Sludge)

  • 박우철;이현창
    • 한국산학기술학회논문지
    • /
    • 제8권1호
    • /
    • pp.1-9
    • /
    • 2007
  • 본 연구에서는 수분 함유량이 높은 하수 슬러지 처리를 위한 열 건조기를 포함하는 100kg/hr급 소용량 사이클론 소각시스템의 소각 성능을 평가하였다. 국내에서 발생하는 하수 슬러지의 물성치를 바탕으로 소각시스템을 설계하였다. 슬러지 수분 정도, 슬러지 투입량, 보조연료량 등 동작조건의 변화에 따른 성능실험을 통하여 소각시스템의 특성을 분석하였다. 정상 운전 시 전체시스템의 압력 손실은 700mmAq로 비교적 적게 나타났으며, 소각기 내부의 연소에 의한 온도분포도 $1000^{\circ}C$미만으로 유지되었다. 수분 86.1%의 슬러지 100kg을 소각하는 경우 $4.7{\ell}/hr$ 정도의 보조 연료가 필요하다. 소각기 내부의 온도가 $1000^{\circ}C$ 미만으로 유지되기 때문에 측정된 대부분의 NOx는 연소과정에 발생된 열적인 NOx 보다는 슬러지 중에 포함된 N 성분의 산화에 의하여 발생되는 연료적 NOx인 것으로 예측된다. 배출된 소각재의 성분 분석 결과, 소각재 속에는 유기물이 전혀 검출되지 않았으며, 이로부터 소각기에서 완전 연소가 이루어진 것으로 예상된다.

  • PDF

폐기물 소각시 중금속 성분의 거동에 관한 연구 (A Study on Behavior of Heavy Metals during Waste Incineration)

  • 박용이;허철구
    • 한국환경과학회지
    • /
    • 제5권6호
    • /
    • pp.785-799
    • /
    • 1996
  • The incineration tests of mixed industrial wastes using the stoker type incinerator are carried out to investigate the partitioning characteristics of heavy metals during incineration. The results obtained from this study are as follow. The partitioning characteristics of heavy metals throughout this incinerator are found that, at given condition of $700^{\circ}C$, the elements with the relatively high boiling point such as Cr, Cu and Pb are partitioned into a bottom ash, a fry ash captured tv cyclone, and a flue gas stream, 67~88%, 2~19% and 6~16% of initial amount entering the incinerator, respectively, but the Cd and Hg of 75~81% is vaporized into the flue gas. It appears that the partitioning characteristics according to the particle size of ash is different between the bottom ash and the fly ash. For bottom ash, the fraction of partitioning into 75${\mu}{\textrm}{m}$ oversized particles is reatively high. For fly ash, the characteristics of distributions with the particle size can not be clearly shown.

  • PDF

폐기물 소각시설 배가스에서의 수은 배출특성 (The Characteristics of Mercury Emission from Municipal Solid Waste (MSW) Incinerator Stack)

  • 이한국
    • 한국환경보건학회지
    • /
    • 제30권5호
    • /
    • pp.378-387
    • /
    • 2004
  • This study was carried to investigate the emission characteristics of mercury from domestic and industrial MSW (municipal solid waste) incinerator stacks. The mercury concentration levels of flue gas from 32 MSW incinerators stacks selected were above the criteria level ($5{\mu}g/S\;m^3$). MSWI facilities exceeding the criteria levels in Korea are due to the poor units comparison of combustion chamber(CC)-cyclone(CY)-stack. So, the mercury from MSW incinerators stack were suspected to contaminate the natural system unless the MSW incinerators were properly controlled. Mean-while, the relationship between mercury concentration and temperature of flue gas in MSW incinerator stacks were examined at two temperature ranges (Group A : $29.85{\sim}327.63^{\circ}C$, Group B : $446.9{\sim}848.15^{\circ}C$). The mercury concentration in flue gas with high temperature range was higher than that of flue gas with low temperature rage. This mean that the temperature of flue gas plays an important role in mercury control in MSW incinerator. The emission characteristics oi mercury was also evaluated by using the correlation matrix between the mercury and NOx, $PM_{10}$, moisture (MO.) at both low temperature and high temperature flue gas ranges. The mercury concentration was mainly affected by NOx, $PM_{10}$. moisture (MO.) at low temperature range, while the mercury concentration at high temperature flue gas was mainly affected by NOx, moisture (MO.). From these results, it was suggested that the temperature of cooling system and the air pollution control device should be properly regulated in order to control mercury of flue gas in MSWI incinerator.

PMF 모델을 이용한 경산지역 PM2.5의 오염원 기여도 추정 (Source Apportionment of PM2.5 in Gyeongsan Using the PMF Model)

  • 정영진;황인조
    • 한국대기환경학회지
    • /
    • 제31권6호
    • /
    • pp.508-519
    • /
    • 2015
  • The objective of this study was to quantitatively estimate $PM_{2.5}$ source contribution in Gyeongsan. Ambient $PM_{2.5}$ samples have been collected on zefluor, quartz and nylasorb filter by $PM_{2.5}$ samplers of cyclone method from September 2010 to December 2012. Collected samples were analyzed for determining 17 inorganic elements, 8 ions, and 8 carbon components after pretreatment. Based on these chemical information, the PMF model was applied to estimate the quantitative contribution of air pollution sources. The results of the PMF modeling showed that the sources were apportioned by biomass burning source (15.5%), secondary sulfate source (16.0%), industry source (10.4%), soil source (7.0%), gasoline source (9.1%), incinerator source (10.4%), diesel emission source (11.0%), and secondary nitrate source (20.6%), respectively. To analyze local source impacts from various wind directions, the CPF analysis were performed using source contribution results with the wind direction values measured at the site.

고정배출원의 먼지 크기별 (PM, PM10, PM2.5) 배출 특성 연구 (The Characterization of PM, PM10, and PM2.5 from Stationary Sources)

  • 김종호;황인조
    • 한국대기환경학회지
    • /
    • 제32권6호
    • /
    • pp.603-612
    • /
    • 2016
  • The objective of this study was to estimate the emission characteristics for PM, $PM_{10}$, and $PM_{2.5}$ in the various stationary sources. The particulate matters collected in the various stationary sources such as power plants (Coal and B-C oil), incinerators(municipal and industrial waste), and glass furnaces. The PM and $PM_{10}$, PM and $PM_{2.5}$, $PM_{10}$ and $PM_{2.5}$ samples were collected using the cyclone type $PM_{10}$, $PM_{2.5}$ samplers and 30 species(19 inorganic species, 9 ionic species, OC and EC) were analyzed by ICP, IC, and TOR/IMPROVE methods. The mass concentrations of PM, $PM_{10}$, $PM_{2.5}$ from nine stationary sources ranged $0.63{\sim}9.58mg/Sm^3$, $0.26{\sim}7.47mg/Sm^3$ and $0.13{\sim}6.34mg/Sm^3$, respectively. The level of $PM_{10}$, $PM_{2.5}$ portion in PM calculated 0.63~0.99, 0.38~0.94, respectively. In the case of emission trend for species, power plant showed high concentrations for Al, Mg, Na, Si, V and $SO_4{^{2-}}$, respectively. Also, Ca, Fe, K, Si, $Cl^-$, and $K^+$ showed high in incinerator. In the case of glass furnace, Na, Pb, K, Si, $Na^+$ and $SO_4{^{2-}}$ represented high concentrations. Power plant showed higher EC/OC concentrations than other sampling sites. These results suggest the possible role for complement establishment process of emission inventory and emission management for PM.

폐기물소각시설의 수은배출특성 연구 (A Study on the Emission Characteristics of Mercury in Municipal and Industrial Waste Incinerators)

  • 석광설;홍지형;이석조;이대균;김대곤;박지현
    • 한국대기환경학회지
    • /
    • 제20권2호
    • /
    • pp.205-213
    • /
    • 2004
  • The emission characteristics of mercury in waste incinerators were investigated to get basic data for the policy development on the emission reduction of mercury (Hg). For the study several important factors were analysed from 4 incinerators such as mercury concentration, emission factors and removal rate for control devices. The results are listed below. Mercury concentrations in the flue gas were 0.39~5.96 $\mu\textrm{g}$/S㎥ in MWI and 2.5~8.8 $\mu\textrm{g}$/S㎥ in IWI. The distributions of gaseous and particulate mercury in flue gas were above 99% and below 1 %, respectively. Therefore, in order to remove mercury effectively, it is important to control the gaseous mercury. Mercury concentrations in fly ash collected from control device were found as 16.2~35.6 mg/kg- ash in FF of MWI. Also mercury concentrations at the front and back point of control device of MWI were 33.45~62.65 $\mu\textrm{g}$/S㎥ and 0.88~3.49 $\mu\textrm{g}$/S㎥, respectively. Emission factors were estimated as 3.67~11.67 mg/ton in FF, 2.6~24.5 mg/ton in MWI with SNCR, SDR and FF, 54.9~192.7 mg/ton in IWI with Cyclone and FF. Emissions from Municipal Waste Incinerator were found both in minimum and maximum ranges. Annual mercury emissions emitted from MWI was estimated as 20.0 kg (6.0~33.9 kg).

고속도로 휴게소의 소형소각로에서 배출되는 대기오염물질 조사 (An Investigation for Air Pollutants Emitted from Small-Scale Incinerators in Highway Service Area)

  • 장영기;최상진;김관;홍민선;최종인;문수호;김순태;김승도
    • 한국대기환경학회지
    • /
    • 제18권6호
    • /
    • pp.539-546
    • /
    • 2002
  • The physicochemical properties of solid wastes generated from seven highway service areas, four branch offices, and one construction site were analyzed in concert with air pollutants including heavy metals emitted from near-by small-scale incinerators. The amount of solid wastes generated from highway areas has been increasing with recent increases in the number of highways and passengers. Twelve incinerators examined in this study generally had capacity smaller than 100 kg/hr, most of which were equipped with cyclone for dust removal. It was seen that the concentrations of the gas-phase air pollutants (e.g., SO$_2$, NO$_{x}$, HCl and H$_2$S) were above the acceptable emission standards except one or two sites. CO concentrations at all incinerators were also higher due to incomplete combustion. In addition, particulate matters showed concentration six times higher at their maximum. The results of heavy metal analysis showed that the concentrations of Cu, Cd, and Ni satisfied the emission standards. whereas Pb at one site and Zn at five sites exceeded the standards. Cr measurement results indicated that 9 of 12 incinerators had higher values than the standard; especially one branch office showed nine times higher than normal concentration. In order to satisfy more stringent emission standards in the near future, it is necessary to install air pollution control system and to develop an intensified management plan.n.