• 제목/요약/키워드: cut off

검색결과 2,218건 처리시간 0.028초

과류(過流) 차단형(遮斷型) 액화(液化) 석유(石油)가스 용기용(容器用) 밸브의 차단(遮斷) 성능(性能) 시험(試驗)에 관(關)한 실험적(實驗的) 연구(硏究) (An Experimental Study on the Cut off Performance Test of Cut off Type Overflow Valve in L.P Gas)

  • 이진
    • 설비공학논문집
    • /
    • 제4권2호
    • /
    • pp.116-122
    • /
    • 1992
  • The purpose of this paper is to determine the cut off flowrate regions of the overflow valve in using L.P gas vassels. The experimental methods were employed to measure the cut off flowrate in the state of constant pressure by using the $N_2$ gas. 1) To determine the optimum cut off flowrate regions, Hose length are required 0.5 meters. 2) Cut off fowrate regions about the each pressure can be suggested as follows. A) Cut off flowrate rigions are $2.0-4.0m^3/hr$ at the pressure of the $1Kg_f/cm^2$. B) Cut off flowrate rigions are$7.0-10.0m^3/hr$ at the pressure of the $10Kg_f/cm^2$.

  • PDF

The improvement of cut-off probe for measuring plasma density at hard conditions

  • 김대웅;유신재;김정형;성대진;장홍영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.202-202
    • /
    • 2011
  • Diagnostics of plasma density is a key factor for monitoring plasma processing. Various probes are invented to measure plasma density and cut-off probe is a one of the most promising diagnostics tool for measuring plasma density. However, at the low density or high pressure the cut-off probe cannot clearly resolve the cut-off peak. Several reasons make this problem: Cut-off likes peaks caused by cavity resonances and weaken transmission spectrum signal at high pressure. Recently, You et al., have researched mechanism of cut-off probe and we improve the cut-off reliability and sensitivity base on that research. Modified cut-off antenna is adapted and bias cut-off probe method is tried. These experiment results have good agreement with the previous study and show good measurement characteristics.

  • PDF

One Lambda LABTypeTM을 이용한 HLA- DR Typing시 나타나는 위양성과 위음성, High-Background 사례와 검사실 습도의 관계분석 (Association between False Positive, False Negative, High-Background Cases and Humidity in One Lambda LABTypeTM HLA-DR Typing)

  • 안향선;손민성
    • 대한임상검사과학회지
    • /
    • 제55권3호
    • /
    • pp.132-142
    • /
    • 2023
  • 서울대학교병원 진단면역검사실에서 HLA 형별 검사를 위한 결과 산출하는 과정에서 HLA-DR 검사 시행 건수 총 611건 중 Lot No.20의 시약에서 빈번히 나타나는 위양성과 위음성으로 의심되는 특이 bead 들의 반응을 발견하게 되었다. 따라서 정확한 결과 산출과정을 모색하기 위하여 특이 bead들의 cut-off 수정을 하지 않은 검사결과 533건과 특이 bead의 cut-off 수정을 한 뒤 결과 산출을 한 78건의 사례들을 가지고 cut-off 수정을 야기시키는 요인을 여러 변수로서 규명하고자 하였다. 검체대상의 인구통계특성과 cut-off 수정 여부를 확인하기 위해 빈도분석, 검사실의 습도를 변수로 넣어 기술통계를 진행하였고, cut-off 수정 여부와 인구통계특성의 연관성을 확인하기 위하여 교차분석을 시행, cut-off 수정 여부에 따른 습도의 차이를 검증하기 위해 독립표본 t검증을 실시하였다. 마지막으로 습도수준에 따른 cut-off 수정비율의 관계를 검증하기 위해 로지스틱 회귀분석을 실시하였다. 결과적으로 검사실의 습도 수준이 증가함에 따라 cut-off 수정사례는 0.986배 감소하는 것으로 나타났다. 이는 습도가 낮아질수록 cut-off 수정률이 증가한다는 것을 의미한다. 따라서 검사실의 습도 또한 HLA typing 결과에 영향을 미치는 요인임을 시사한다.

Cut-off Probe Frequency Spectrum의 물리적 해석

  • 유신재;김대웅;김정형;성대진;신용현;나병근;장홍영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.200-200
    • /
    • 2011
  • Although the cut-off probe, a precise measurement method for the electron density, is widely used in the industry, the physics on the wave spectrum of the cut-off is not understood yet, only cut-off point frequency containing the information of electron density has been analyzed well. This paper analyzes the microwave frequency spectrum of the cut-off probe to see the physics behind using both microwave field simulation (CST Microwave Studio) and simplified circuit simulation. The result shows that the circuit model well reproduces the cut-off wave spectrum especially in the low frequency regime where the wavelength of the driving frequency is larger than the characteristic length and reveals the physics of transmission characteristics with frequency as resonances between vacuum, plasma and sheath. Furthermore, by controlling the time domain in solver of the microwave simulator, the cut-off like transmission peaks above the cut-off frequency which has been believed as cavity effect is verified as chamber geometry effect. The result of this paper can be used as the basis for the improvement of cut-off probe.

  • PDF

다익 송풍기의 이산 주파수 소음 저감을 위한 실험적 연구 (An experimental study for reduction of B.P.F. noise level of multi-blade fan)

  • 김영찬;이상환
    • 설비공학논문집
    • /
    • 제11권2호
    • /
    • pp.167-175
    • /
    • 1999
  • B.P.F.(Blade Passing Frequency) levels were measured with the cut-off clearance changes. The velocity inside the scroll, pressure fluctuation at cut-off region, and the scroll surface pressure distribution along the scroll from the cut-off to outlet were measured. With a certain cut-off clearance the improvement of efficiency and attenuation of B.P.F. noise level could be achieved. The measured results of pressure fluctuation and scroll surface pressure distribution showed that the secondary flow inside the scroll increased B.P.F. noise level at the cut-off region as the cut-off clearance got wide.

  • PDF

절사법과 추정 (Cut off Sampling and Estimation)

  • 한근식
    • 한국조사연구학회:학술대회논문집
    • /
    • 한국조사연구학회 2003년도 춘계학술발표대회
    • /
    • pp.29-33
    • /
    • 2003
  • 사업체조사에서 절사법이 흔히 이용되고 있다. 이 경우, 절사되는 사업체가 모집단에서 차지하는 비중이 모집단 전체에 비하여 매우 작다 본 연구에서는 사레를 이용하여 모집단을 절사층, 표본층, 전수층으로 구분하고 절사층을 추정하는 문제를 살펴보도록 한다.

  • PDF

Photobacterium damselae의 디스크 확산법 결과에 대한 Epidemiological Cut-off Value의 결정 (Epidemiological Cut-off Values Generated for Disc Diffusion Data from Photobacterium damselae)

  • 권문경;임윤진;김명석;서정수;김도형
    • 한국수산과학회지
    • /
    • 제49권6호
    • /
    • pp.838-844
    • /
    • 2016
  • In this study, epidemiological cut-off values were estimated for 44 Photobacterium damselae isolates, since clinical breakpoints have not been established for this pathogenic bacterium. The susceptibility of the isolates to 10 antibiotics was evaluated using internationally standardized disc diffusion protocols. Normalized resistance interpretation was used to generate statistically valid epidemiological cut-off values for the susceptibility data. There were not enough strains exhibiting full sensitivity to ampicillin and amoxicillin to allow analysis of these antibiotics. Because there were only a marginally sufficient number of strains exhibiting full sensitivity to oxytetracycline, the cut-off value generated provided only a provisional estimate. The valid wild-type cut-off values were <13, 13, 9, 22, 25, 27, and 28 mm for gentamicin, cephalexin, erythromycin, oxolinic acid, flumequine, florfenicol, and sulfamethoxazole/trimethoprim, respectively. The application of these cut-off values should greatly facilitate the rational selection of antibiotics for use in commercial fish farms.

SPECT filter의 cut off level에 따른 반폭치(FWHM) 크기에 관한 연구 (A study of Full Width at Half Maximum(FWHM) according to the Filter's Cut off level in SPECT camera)

  • 박성옥;권수일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제26권2호
    • /
    • pp.63-69
    • /
    • 2003
  • 영상재구성에 있어 잡음(noise)을 제거하고 공간 분해능과 대조도 분해능을 향상시킬 수 있는 filter에서 cut off 주파수 level에 따라 영상의 질에 영향을 미치는 경향을 반폭치(FWHM : full width at half maximum)측정방법을 이용하여 비교하였다. 선택한 filter의 종류는 Band-limited, Sheep-logan, Sheep-logan Hanning, Generalized Hamming, Low pass cosine, Parazen, 그리고 Butterworth filter이다. SPECT 영상을 기록하기 위한 점선원(point source)으로 방사성의약품 $^{99m}TcO_4$을 이용하였으며 점선원에 대하여 각각의 filter에서 cut off 주파수 준위별로 영상을 기록하고 axial transverse, coronal sagittal... fh의 section image의 profile 곡선에서 반폭치을 측정하여 비교하였다. 본 연구에서 사용한 filter들에 있어서는 cut off level에 따라 X, Y, 그리고 Z축 방향으로의 평균 FWHM의 길이가 $9.16\;mm{\sim}18.14\;mm$까지 측정되었는데 cut off level 0.7에서 Generalized Hamming filter와 Band limited filter의 경우 9.16 mm로 반폭치의 길이가 제일 짧은 것으로 나타났다.

  • PDF

Should Cut-Off Values of the Risk of Malignancy Index be Changed for Evaluation of Adnexal Masses in Asian and Pacific Populations?

  • Yavuzcan, Ali;Caglar, Mete;Ozgu, Emre;Ustun, Yusuf;Dilbaz, Serdar;Ozdemir, Ismail;Yildiz, Elif;Gungor, Tayfun;Kumru, Selahattin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권9호
    • /
    • pp.5455-5459
    • /
    • 2013
  • Background: The risk of malignancy index (RMI) for the evaluation of adnexal masses is a sensitive tool in certain populations. The best cut off value for RMI 1, 2 and 3 is 200. The cut off value of RMI-4 to differentiate benign from malignant lesions is 450. Our aim was to evaluate the efficiency of four different malignancy indexes (RMI1-4) in a homogeneous population. Materials and Methods: We evaluated a total of 153 non-pregnant women with adnexal masses who did not have a history of malignancy and who were above 18 years of age. Results: A cut-off value of 250 for RMI-1 provided 95.9% inter-observer agreement, yielding 95.9% specificity, 93.5% negative predictive value, 75.0% sensitivity and 82.8% positive predictive value. A cut-off value of 250 for RMI-1 showed high performance in preoperative diagnosis of invasive malignant lesions than cut-off value of 200 in our population. A cut-off value of 350 for RMI-2 provided 94.5% inter-observed agreement, yielding 94.2% specificity, 93.4% negative predictive value, 75.0% sensitivity and 77.4% positive predictive value. RMI-2 showed the higher performance when the cut-off value was set at 350 in our population. A cut-off value of 250 provided 95.2% inter-observer agreement, yielding 95.0% specificity, 93.2% negative predictive value, 75.0% sensitivity, and 88.0% positive predictive value. RMI-3 showed the highest performance to diagnose malignant adnexal masses when the cut-off value was set at 250. In our study, RMI-4 showed similar statistical performance when the cut-off value was set at 400 [(Kappa: 0.684/p=0.000), yielding 93.8% inter-observer agreement, 93.4% specificity, 93.4% negative predictive value, 75.0% sensitivity, and 75.0% negative predictive value]. Conclusions: We showed successful utilization of RMIs in preoperative differentiation of benign from malignant masses. Many studies conducted in Asian and Pacific countries have reported different cut-off values as was the case in our study. We think that it is difficult to determine universally accepted cut-off values for RMIs for common use around the globe.

인공수초재배섬에서 수생식물 지상부 절취주기별 수중영양염류 제거효율 (Effect of Cut-off Intervals on Nutrients Removal Efficiency in Hydrophytes at the Artificial Vegetation Island)

  • 박혜경;변명섭;최명재;윤석환;전남희
    • 한국물환경학회지
    • /
    • 제25권2호
    • /
    • pp.221-226
    • /
    • 2009
  • We investigated the most effective cutting interval for underwater nutrient removal through cut off the emergent part of hydrophytes at artificial vegetation island (AVR) which was installed for the purpose of water quality improvement in Lake Paldang. We divided the planting area of Phragmites japonica into three parts according to the cutting intervals. The shoot height and relative growth rate of P. japonica, nutrient contents and biomass of cut off P. japonica were measured at each cutting interval. The amount of nutrients which were removed through cut off at each cutting interval was calculated. P. japonica showed full growth, 80% and 60% of full growth before first cut off at three-months, two-months and one-month cutting interval condition respectively. Three-month cutting interval condition showed the largest biomass of cut off P. japonica and one-month cutting interval condition showed the least. However the cut off P. japonica showed the highest content of nutrients at one-month cutting interval condition and the least at three-month cutting interval condition. The amount of phosphorus and nitrogen removal at two-month cutting off condition is the largest among three cutting interval conditions indicating that cut off the emergent part of P. japonica every two months is the most effective to remove the nutrients from water at AVR in eutrophic lakes.