• Title/Summary/Keyword: custom-made

Search Result 352, Processing Time 0.035 seconds

A STUDY ON THE FRACTURE STRENGTH OF TEETH RESTORED WITH A CARBON FIBER POST UNDER CYCLIC LOADING (반복하중하에서의 carbon fiber post의 파절강도에 관한 연구)

  • Yi, Yang-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.640-649
    • /
    • 2000
  • In the restoration of endodontically treated teeth, carbon fiber post was recently introduced. The purpose of this in vitro study was to investigate the fracture strength of teeth restored with a pre-fabricated carbon fiber post in comparison with teeth restored with a prefabricated titanium post & custom cast gold post after cyclic loading in the different environment. A total of 30 recently extracted human central incisors of similar dimension with crowns removed were used. All teeth were placed into acrylic blocks and every steps for post and core fabrication were made accord-ing to manufacture's instruction. The post length and core dimensions were standardizd. All teeth were divided into 6 groups: 1) carbon fiber post / atmosphere, 2) titanium post / atmosphere, 3) gold post / atmosphere, 4) carbon fiber post / wet, 5) titanium post / wet, 6) gold post / wet. Carbon fiber post and titanium post were cemented in place using resin cement and cores were fabricated with Ti-Core. Custom cast gold post was made from Duralay pattern resin and cemented using resin cement, too. All specimens were thermocycled 10,000 times. After 50,000 cyclic loading, failure strength was measured using Instron testing machine. Kruskal-Wallis test followed by Mann-Whitney test was used to compare the mean fracture strength. Results were as follows : 1. All specimens showed lower fracture strength in wet environment after cyclic loading than in atmosphere condition, but did not reveal a significant difference. 2. There was no significant difference between carbon fiber post specimen and titanium post specimen in the same environment. 3. Gold cast post specimen showed significant different greater fracture strength than those of others in the same environment. 4. Carbon fiber post specimen showed no root fracture.

  • PDF

MOUTHGUARD FOR PREVENTING ORAL INJURIES IN CHILDREN (소아환자에 있어서 외상방지를 위한 마우스가드의 치험례)

  • Kim, Kyoung-Hee;Kim, Jong-Soo;You, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.3
    • /
    • pp.537-542
    • /
    • 2005
  • Dentofacial trauma can result in tooth fracture, avulsion, facial bone fracture. The Unites states and Japan mandated the use of mouthguards for contact sports. But, Korean didn't. Mouthguards divided into ready-made type and custom-made type. Mouthguards protect the lips, intraoral soft tissues, teeth and provide the mandible with resilient support to prevent jaw fracture and dislocations. Sports-related accidents have been reported to be one of the most common causes of dentofacial trauma. Sports trauma of involving teeth with incomplete root formation cause long chair time, multiple visit, economic considerations, additional dental services. So, mouthguards can offer considerable protection against sports-related trauma.

  • PDF

Effectiveness of a Custom-made Multi Purpose Brachytherapy Phantom (자체 제작한 근접방사선치료용 다목적 팬텀의 유용성 평가)

  • Jang, In-Gi;Lee, Jin-Joung;Kim, Wan-Sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.119-125
    • /
    • 2006
  • Purpose: To measure the dose for dose optimization at the reference point (A, B) and the critical organ with multi Purpose brachytherapy phantom (MPBP). For this wort the MPBP was custom made, and designed to reconstruct the treatment applicator using multi function applicator (MFA) in the same way as the treatment of patient. Materials and Methods: Dose measurements were made at the reference points (A, B) and the bladder with thermoluminescence dosimeter (TLD) for four patients with tandem and ovoid of uterine cervix cancer using the phantom. In Phantom, Total 20 times of the measurements were made with 5 times a patient. Results: The results of TLD measurements in MPBP phantom showed the relative error ranging from -3.2% to 3.8% at A point, and -1.4% to 4% at B point and 1.3% to 7.15% at the bladder of reference point. Conclusion: The reproducibility of dose measurement under the same condition as the treatment could be achieved using the custom-made MFA in phantom and the dose at the reference point (A, B) and bladder could be analyzed accurately. The measured dose acquired in MPBP can apply for the dose optimization.

  • PDF

The Effectiveness of the Use of Custom-Made Foot Orthotics on Temporal-Spatial Gait Parameters in Children With Spastic Cerebral Palsy

  • Kim, Sung-Gyung;Ryu, Young-Uk
    • Physical Therapy Korea
    • /
    • v.19 no.4
    • /
    • pp.16-23
    • /
    • 2012
  • This study examined the effects of custom-made foot orthotics on the temporal-spatial gait parameters in children with cerebral palsy. Twenty spastic bilateral cerebral palsy (spastic CP) children (11 boys and 9 girls) participated in this study. GAITRite was used to examine the velocity, cadence, step length differential, step length, stride length, stance time, single support time, double support time, base of support, and toe angle while walking with and without foot orthotics. The differences in temporal-spatial parameters were analyzed using paired t-test. The significance level was set at .05. The velocity, cadence, both step lengths, both stride lengths, both bases of support and right toe angle significantly increased when the children with spastic CP with foot orthotics compared to without foot orthotics (p<.05). The step length differential between the two extremities, left stance time and left single support time, significantly decreased with foot orthotics (p<.05). Right stance time, right single support time, both double support times and left toe angle showed little change (p>.05). This study demonstrated that foot orthotics were beneficial for children with spastic CP as a gait assistance tool.

Automatic Hand Measurement System from 2D Hand Image for Customized Glove Production

  • Han, Hyun Sook;Park, Chang Kyu
    • Fashion & Textile Research Journal
    • /
    • v.18 no.4
    • /
    • pp.468-476
    • /
    • 2016
  • Recent advancements in optics technology enable us to realize fast scans of hands using two-dimensional (2D) image scanners. In this paper, we propose an automatic hand measurement system using 2D image scanners for customized glove production. To develop the automatic hand measurement system, firstly hand scanning devices has been constructed. The devices are designed to block external lights and have user interface to guide hand posture during scanning. After hands are scanned, hand contour is extracted using binary image processing, noise elimination and outline tracing. And then, 19 hand landmarks are automatically detected using an automatic hand landmark detection algorithm based on geometric feature analysis. Then, automatic hand measurement program is executed based on the automatically extracted landmarks and measurement algorithms. The automatic hand measurement algorithms have been developed for 18 hand measurements required for custom-made glove pattern making. The program has been coded using the C++ programming language. We have implemented experiments to demonstrate the validity of the system using 11 subjects (8 males, 3 females) by comparing automatic 2D scan measurements with manual measurements. The result shows that the automatic 2D scan measurements are acceptable in the customized glove making industry. Our evaluation results confirm its effectiveness and robustness.

A Study on Manpower Education Plan of the Green Growth Industry of SME in Gwangju Area (광주지역 중소기업의 녹색성장산업 인력양성방안에 관한 연구)

  • Yim, Ki-Heung
    • Journal of Digital Convergence
    • /
    • v.8 no.2
    • /
    • pp.115-129
    • /
    • 2010
  • The purpose of this study is to explore manpower education plan of green growth industry of SME in Gwangju area. Nowadays, according to the change of green growth paradigm, We need to be the green switching strategy for solving the structural problem and overcoming a crisis in SME. Based on the findings, the study showed that SME in Gwangju area need to build up network of size and industrial classification. Also, green fusion technology grafting on the existing industry and the policy of educating manpower in long term and custom-made plan of educating manpower need to be followed.

  • PDF

Adult-Onset Primary Focal Foot Dystonia Improved with Custom Made Ankle-Foot Orthosis (맞춤형 단하지보조기 적용으로 호전된 성인형 일차성 국소성 족부 근긴장이상증)

  • Lee, Seunghwan;Lee, Yong Min;Uhm, Kyeong Eun;Lee, Jongmin
    • Clinical Pain
    • /
    • v.19 no.1
    • /
    • pp.40-44
    • /
    • 2020
  • The foot or lower extremity is rarely the initial site in adult-onset dystonia, whereas dystonia in children often begins in the foot. Isolated lower extremity dystonia in adults is rarely on a primary basis. Oral anti-dystonic medications have been found unsatisfactory in providing adequate symptomatic relief. On the other hand, botulinum toxin injections have been reported as beneficial. It is also known that personalized orthosis can be an effective solution for patients of dystonia. The purpose of this report is to demonstrate a case of primary focal foot dystonia that was effectively treated with botulinum toxin injection and the custom-made ankle-foot orthosis.

Development and performance evaluation of a low-cost custom-made extensional rheometer (저비용 수제 연신레오미터 개발 및 성능 평가)

  • Sihyun Kim;Hanbyeol Pak;Jeong-Hyun Kim
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.1
    • /
    • pp.110-118
    • /
    • 2023
  • Characterizing the extensional rheological properties of non-Newtonian fluids is crucial in many industrial processes, such as inkjet printing, injection molding, and fiber engineering. However, educational institutions and research laboratories with budget constraints have limited access to an expensive commercial extensional rheometer. In this study, we developed a custom-made extensional rheometer using a CO2 laser cutting machine and 3D printer. Furthermore, we utilized a smartphone with a low-cost microscopic lens for achieving a high spatial resolution of images. The aqueous polyethylene-oxide (PEO) solutions and a Boger fluid were prepared to characterize their extensional properties. A transition from a visco-capillary to an elasto-capillary regime was observed clearly through the developed rheometer. The extensional relaxation time and viscosity of the aqueous PEO solutions with a zero-shear viscosity of over 300 mPa·s could be quantified in the elasto-capillary regime. The extensional properties of the solutions with relatively small zero shear viscosity could be calculated using a smartphone's slow-motion feature with increasing temporal resolution of the images.

Operating characteristics analysis of 3-phase voltage disturbance generator for the test of custom power devices (전력품질 개선장치의 성능시험을 위한 3상 전압변동 발생기의 동작특성 분석)

  • Park, S.D.;Nho, E.C.;Kim, I.D.;Chun, T.W.;Kim, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.244-246
    • /
    • 2006
  • This paper deals with an analysis of SCR thyristor switching pattern for a power quality disturbance generator with phase jump function. The proposed generator can be applied to the performance test of custom power devices. Voltage sag, swell, outage, unbalance and phase jump after outage are provided by the generator. The phase jump operating principle of the generator is described and analysed. Especially, a proper switching of the SCR thyristors for the proposed generator is important to guarantee the system reliability. Therefore the switching patterns for the thyristors in each made were analysed.

  • PDF