• Title/Summary/Keyword: current-fed

Search Result 800, Processing Time 0.027 seconds

Automatic frequency Control Current-Source Inverter for Forging Application

  • Chudjuarjeen, Saichol;Koompai, Chayant;Monyakul, Veerapol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.238-242
    • /
    • 2004
  • The paper describes an automatic frequency control current-fed inverter for forging applications. The IGBT in series with diodes as its switching devices in the inverter circuit which is of full-bridge type. The operating frequency is automatically tracked to maintain a small constant leading phase angle when load parameters change. The load voltage is controlled to protect the switches. The output power can be adjusted by varying the input current from phase controlled rectifiers which is a part of current source. The system has been operated at 15-17 kHz. The output power transferred to the load is 1,595 watts. It can heat the steel work pieces with 15 mm diameter and 120 mm long from room temperature to approximately 1100 $^{\circ}C$ within 20 seconds with 0.97 leading power factor on the input side.

  • PDF

A Study on characteristics of Current-Fed Type Inverter driven by Voltage Source (전압원 구동시의 전류형 인버어터의 특성연구)

  • Lee, Dal-Hae;Kim, Dong-Hee;Lee, Bong-Seop;Yoo, Dong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.587-590
    • /
    • 1991
  • It is general to make the circuit analysis of current-fed type inverter driven by current source with rippleless input under the assumption of infinite induction Ld in direct current reactor(DCL). This paper focusing on the fact that Ld has bounded value in real circuit, examines operating characteristics by analysis of static state characteristics of current type inverter driven by voltage source and compares it with the operating characteristics of the circuit driven by current source.

  • PDF

Novel Electromagnetic Induction Eddy Current DPH based Continuous Pipeline Fluid Heating using Soft Switching PWM High Frequency Inverter

  • Nam, Jing-Rak
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.3
    • /
    • pp.305-309
    • /
    • 2008
  • This paper presents an innovative prototype of a new conceptual electromagnetic induction eddy current based fluid heating appliance using voltage-fed quasi resonant zero voltage soft switching PWM high-frequency inverter using IGBTs, which can operate at a constant frequency variable power regulation scheme. The promising simple high efficient low noise inverter type electromagnetic induction eddy current based pipeline fluid heating appliance is proposed for saturated steam generator, superheated steam generator, hot water and hot air producer, metal catalyst heating for exhaust gas cleaning in engine. Under these technological backgrounds, a novel electromagnetic induction eddy current Dual Packs Heater(DPH) based pipeline fluid heating incorporates thin metal layer type package for continuous fluid heating appliances applying two types of voltage-fed quasi load resonant ZVS-PWM high frequency inverter. The unique features of a novel electromagnetic induction eddy current DPH based continuous pipeline fluid heating appliance is illustrated on the basis of simulation and discussed for the steady state operating characteristics and experimental results.

Fuel Cell Generation Systems with Active Clamp Current fed Half Bridge Converter (능동 클램프 전류형 하프 브리지 컨버터를 적용한 연료전지 발전시스템)

  • Jang S. J.;Kim J. T.;Lee T. W.;Lee B. K.;Won C. Y.
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.78-86
    • /
    • 2005
  • Recently, a fuel cell with low voltage and high current output characteristics is remarkable for new generation system. It needs both a dc-dc boost converter and dc-ac inverter to be used in fuel cell generation system. Therefore, this paper presents dc-dc active clamp current-fed half-bridge converter with ZVS for fuel cell generation system. The proposed converter has outstanding advantages over the conventional dc-dc converters with respect to high efficiency and high component utilization. The Fuel Cell generation system consist of active clamp current-fed half-bridge converter to boost the Fuel Cell(PEMFC) voltage(28∼43[Vdc]) to 380[Vdc]. A single phase full-bridge inverter is implemented to produce 220[Vac], 60[Hz] AC outputs.

Analysis and Compensation of Current Measurement Errors in a Doubly Fed Induction Generator

  • Son, Yung-Deug;Im, Won-Sang;Park, Han-Seok;Kim, Jang-Mok
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.532-540
    • /
    • 2014
  • It is necessary to measure the current of rotor for controlling the active and reactive power generated by the stator side of the doubly fed induction generator (DFIG) system. There are offset and scaling errors in the current measurement. The offset and scaling errors cause one and two times current ripples of slip frequency in the synchronous reference frame of vector control, respectively. This paper proposes a compensation method to reduce their ripples. The stator current is variable according to the wind force but the rotor current is almost constant. Therefore input of the rotor current is more useful for a compensation method. The proposed method adopts the synchronous d-axis current of the rotor as the input signal for compensation. The ripples of the measurement errors can be calculated by integrating the synchronous d-axis stator current. The calculated errors are added to the reference current of rotor as input of the current regulator, then the ripples are reduced. Experimental results show the effectiveness of the proposed method.

Analysis of Doubly Fed Variable-Speed Pumped Storage Hydropower Plant for Fast Response (빠른 응답성을 갖는 가변속 DFIM 분석)

  • Sun, Jinlei;Seo, Joungjin;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.425-430
    • /
    • 2022
  • A pumped storage power station is an important means to solve the problem of peak load regulation and ensures the safety of power grid operation. The doubly fed variable-speed pumped storage (DFVSPS) system adopts a doubly fed induction machine (DFIM) to replace the synchronous machine used in traditional pumped storage. The stator of DFIM is connected to the power grid, and the three-phase excitation windings are symmetrically distributed on the rotor. Excitation current is supplied by the converter. The active and reactive power of the unit can be quickly adjusted by adjusting the amplitude, frequency, and phase of the rotor-side voltage or current through the converter. Compared with a conventional pumped storage hydropower station (C-PSH), DFVSPS power stations have various operating modes and frequent start-up and shutdown. This study introduces the structure and principle of the DFVSPS unit. Mathematical models of the unit, including a model of DFIM, a model of the pump-turbine, and a model of the converter and its control, are established. Fast power control strategies are proposed for the unit model. A 300 MW model of the DFVSPS unit is established in MATLAB/Simulink, and the response characteristics in generating mode are examined.

Current-fed Push-Pull type high frequency resonant inverter for wax-sealing

  • Won, Jae-Sun;Kim, Dong-Hee;Ro, Chae-Cyun;Kim, Min-Huei
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.225-230
    • /
    • 2000
  • This paper describes a double-ended current fed push-pull type high frequency resonant inverter used as the power supply for wax-sealing. The proposed inverter can realize ZVS operation by using resonant capacitor to ZVS capacitor and has some merits not only reduction of switch current distribution but also extension of load range compare to the conventional single-ended current fed push-pull type high frequency resonant inverter. This analysis of proposed circuit uses normalized parameter ad characteristic estimation which is needed in each step before design is generally described according to normalized frequency($\mu$), normalized resistance(λ) and parameters. It is also presented as an example of method of the circuit design based on estimation analysis values from theoretical analysis. The theoretical analysis is proved through experiment and this circuit shows that it can be used practically as the power supply system for wax-sealing and DC-DC converter.

  • PDF

A Characteristic Analysis of Current-Fed Push Pull type DC-DC converter using LCCC Resonant circuit and ZVS function (LCCC 공진회로와 ZVS 기능을 동시에 갖는 전류형 Push Pull DC-DC 컨버터의 특성해석)

  • An, Hang-Mock;Hwang, Gye-Ho;Lee, Dal-Hae;Nam, Seung-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1324-1326
    • /
    • 2000
  • This paper proposes a Current-Fed Push Pull type DC-DC converter using LCCC Resonant circuit and Zero Voltage Switching function to reduce turn on and off loss at the switching instants. This paper have the advantage which is able to operating safely in load short, because of DC reactor is connected with resonance reactor in order to supply a fixed current with low ripple from DC Power supply. The capacitor ($C_1$, $C_2$) connected in switch are common using as resonance capacitor and ZVS capacitor. The analysis of the proposed Current-Fed Push Pull type DC-DC converter is generally described by using normalized parameter, and we have evaluated characteristic values which is needed to design a circuit. We confirm a rightfulness theoretical analysis by comparing a theoretical values and experimental values obtained from experiment using MOSFET as switching devices.

  • PDF

Determination of Regulator Parameters and Transient Analysis of Modified Self-commutating CSI-fed IM Drive

  • Pandey, A.K.;Tripathi, S.M.
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.48-58
    • /
    • 2011
  • In this paper, an attempt has been made to design the current and speed proportional and integral (PI) regulators of self-commutating current source inverter-fed induction motor drive having capacitors at the machine end and to investigate the transient performance of the same for step changes in reference speed. The mathematical model of the complete drive system is developed in closed loop, and the characteristic equations of the systems are derived using perturbation about steady-state operating point in order to develop the characteristic equations. The D-partition technique is used for finding the stable region in the parametric plane. Frequency scanning technique is used to confirm the stability region. Final selection of the regulator parameters is done by comparing the transient response of the current and speed loops for step variations in reference. The performance of the drive is observed analytically through MATLAB simulation.

Control characteristics of the prototype power trains of 1MW Uldolmok tidal current plant (울돌목 조류발전소 설치용 1MW 발전설비 시제품 제어특성)

  • Park, Jung-Woo;Lee, Ki-Wook;Kim, Dong-Wook;Lee, Kwang-Soo;Park, Jin-Soon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.644-647
    • /
    • 2007
  • We have developed electrical power train for 1MW tidal current plant which is composed of both 500kW tidal current plant with doubly-fed induction generator and 500kW tidal current plant with synchronous generator. To check performances of the protype, 2MW dynamometer is used to simulate a helical turbine, and then protype generator and converter are coupled with the dynamometer separately. From the suggested experimental results it is reconfirmed that two kinds of the power train to be installed at the Uldolmok located at southwestern shore in Korea are able to operate under all kinds of the condition about speed and power.

  • PDF