• Title/Summary/Keyword: current-effect

Search Result 10,222, Processing Time 0.037 seconds

Evaluation of the Device Temperature and Optical Characteristics in High Power White LED Lamp by Driving Condition (고출력 백색 LED 램프의 구동조건에 따른 온도 및 광 특성 평가)

  • Yun, Jang-Hee;Ryeom, Jeong-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.11
    • /
    • pp.33-38
    • /
    • 2011
  • In this paper, the effect of pulse current and generated heat on characteristics of the LED is measured and evaluated. For experiments, the LED driving circuit and digital logic which determines period and duty ratio of lighting are designed. At rated current, the temperature and optical characteristics of the LED with change in duty ratio and period are compared, and those of the LED with change in duty ratio and existence of cooling fan are also compared at constant average current. As a result, frequency does not affect device temperature and optical characteristic of the LED but duty ratio does. Also, the cooling fan is less effective on those of the LED at rated current.

The Improvement Effect of Input Current Waveform of Two New Main Switching Boost Rectifiers

  • Ha, Sung-Hyun;Kim, Chang-Il;Kim, Soo-Wook;Nam, Jing-Rak;Mun, Sang-Pil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.3
    • /
    • pp.15-26
    • /
    • 2008
  • This paper proposes a new sinusoidal rectifier which improves input factor and input current waveform without complicated switching modulation such as pulse width or a complicated feed back control. The proposed rectifier consists of a pair of capacitors connected in series, a full bridge diode rectifier, a pair of inductors, and a pair of switching devices connected in series. While the configuration of the sinusoidal rectifier is simple in itself, it effectively reduces the reactive power and harmonics involved(IEC555-2 SC77A90 Class C) in input line current. The excellent properties of the new sinusoidal rectifier are verified by theoretical analysis and experimental results.

Characteristics of a Flux-Lock Type Superconducting Fault Current Limiter According to the Parallel Connection of the Superconducting Elements. (초전도 한류소자의 병렬연결에 따른 자속구속형 초전도 한류기의 특성 분석)

  • Oh, Kum-Gom;Jung, Byung-Ik;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.198-201
    • /
    • 2008
  • We investigated the operating characteristics of the flux-lock type superconducting fault current limiter(SFCL) with the parallel connection between the primary and secondary windings which are connected with two superconducting units in series. The parallel connection for current level increase of the flux-lock type SFCL is necessary to apply the SFCL into the power system. The resistance generated in superconducting units was dependent upon the winding direction of the primary and the secondary coils, which can reduce the power burden. The resistance of the superconducting elements in the subtractive polarity winding is higher than that of the additive polarity winding. The fault current limiting effect of the subtractive polarity winding is better than that of the additive polarity winding. From this results, we confirmed that the power capacity of the flux-lock type SFCL could be increased by the parallel connection of the superconducting units.

The conductive characteristic of oil-immersed paper (유침절연지의 도전특성)

  • 성영권;이헌용
    • 전기의세계
    • /
    • v.25 no.2
    • /
    • pp.87-91
    • /
    • 1976
  • Experimentally to investigate the conductive characteristic of oil-immersed paper, we observed the leakage current-voltage characteristic of oil-immersed paper, the temperature dependence of ionization rate and the effect of metal electrode on the leakage current. The results showed that the leakage current-voltage characteristic generally followed the experimental equation i=i$_{0}$ exp (K.root.E) and the slope K did not change by the temperature and electric strength, but only when the direct voltage was applied. And also the leakage current seemed to depend on the work function of metal electrode. From the above results we concluded that the deterioration of oil-immersed paper was not only caused by the thermionic emission from the cathode but also by the conductive property of oil-immersed paper in itself and the work function of metal electrode.e.

  • PDF

A Study on the Normal-zone Propagation Velocity in a Superconducting Coil (초전도 코일의 국부 퀜치 발생시 상전도영역 전파속도 해석)

  • 배진한;서용석;오윤상;고태국
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.7
    • /
    • pp.1041-1049
    • /
    • 1994
  • Longitudimal and transverse normal zone propagations in the superconducting coil are analyzed and propagation velocity is derived from the heat balance equations in the propagating boundary region. The results of applying to the specific superconducting wire show that propagation velocity is linearly proportional to the transport current and increasing ramp current speeds up the longitudinal velocity by 1.22[m/s] under the applied field of 2T. Transient heat transfer has a significant effect on the normal zone propagation velocity and it decreases longitudinal velocity by 5.2[m/s] under the applied field of 2T as being compared to the steady-state heat transfer. Increasing ramp current speeds up the Z-axis transverse propagation velocity by 0.042[m/s] and transverse velocity of R and Z axis is costant regardless of the current flows.

Changes of Electrical Characteristics of Arrester Blocks by a Multiple-lightning Impulse Current (다중 뇌충격전류에 의한 피뢰기 소자의 전기적 특성 변화)

  • Lee, J.H.;Cheon, S.G..;Kim, I.K.;Han, J.S.;Kil, G.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2035-2037
    • /
    • 2000
  • This paper describes the effect of lightning impulse current on deterioration of ZnO blocks for distribution arrester. In this study. a multiple-lightning impulse current generator which can produce quadruple 8/20 ${\mu}s$ 5 kA is designed and fabricated, and total energy applied to the arrester block at each pulse is about 1,217 J. The experimental results indicate that the type of arresters are more vulnerable to deteriorate or damage at multiple-lightning impulse current.

  • PDF

Critical Current Degradation Characteristics by Temperature Difference of L$N_2$-Normal in Repetitive Bending Strain of High Temperature Superconducting Tape (고온 초전도 선재의 굽힘횟수와 온도차에 의한 임계전류저하특성)

  • 김해준;김석환;송규정;김해종;배준한;조전욱;성기철
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.274-277
    • /
    • 2003
  • Critical current(Ic) degradation of HTS tapes after bending is one of the hottest issues in HTS development and application studies. Many people are measuring Ic degradations for effect of bending radius. However even if the bending radius is larger than the breaking radius a HTS tapes can be damaged by repetitive bending, which is unavoidable in the winding processes. Therefore, We studied the Ic degradation after repetitive bending. at 77K with self-field, of Bi-2223 tapes processed by "Powder-in-Tube" technique, which was made by America Superconductor Corporation(AMSC) and superconductiing tapes that strain is imposed measured critical current by temperature difference of L$N_2$ and normal temperature. Like this, critical current could measure that degradation about 1~3% by temperature difference. These results will amount the most important basis data in power electric machine of superconductivity cable, magnet, etc that winding work is require.

  • PDF

Development of innovative superconducting DC power cable

  • Matsushita, Teruo;Kiuchi, Masaru
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.3
    • /
    • pp.1-7
    • /
    • 2017
  • It is required to reduce the cost of superconducting cable to realize a superconducting DC power network that covers a wide area in order to utilize renewable energy. In this paper a new concept of innovative cable is introduced that can enhance the current-carrying capacity even though the same superconducting tape is used. Such a cable can be realized by designing an optimal winding structure in such a way that the angle between the tape and magnetic field becomes small. This idea was confirmed by preliminary experiments for a single layer model cable made of Bi-2223 tapes and REBCO coated conductors. Experiments of three and four layer cables of practical sizes were also done and it was found that the current-carrying capacity increased as theoretically predicted. If the critical current properties of commercial superconducting tapes are further improved in a parallel magnetic field, the enhancement will become pronounced and this technology will surely contribute to realization of superconducting DC power network.

A Study on the Development of a Transient Voltage Blocking Device for Info-communication Facilities (정보통신기기용 과도전압 차단장치의 개발에 관한 연구)

  • 한주순
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.159-167
    • /
    • 1999
  • This paper presents a new transient voltage blocking device(TOBD)which low power and high frequency bandwidth to protect info-communication facilities from transient voltages. Conventional protection devices have some problems such as low frequency bandwidth low ener-gy capacity and high remnant voltage. in order to improve these limitations a hybrid type TOBD which consists of a gas tube avalanche diodes and junction type field effect transistor (JFETs) is developed. The TOBD differs from the conventional protection devices in configuration and JFETs are used as an active non-linear element and a high speed switching diode with low capacitance limited high current. Therefore the avalanche diode with low energy capacity are protected from the high current and the TOBD has a very small input capacitance. From the performance test using combination surge generator which can produce $1.2/50{\mu}m$ 4.2 kV/max, $8/20{\mu}m$ 2.1 kAmax it is confirmed that the proposed TOBD has an excellent protection per-formance in tight clamping voltage and limiting current characteristics.

  • PDF

Capacity Requirement Estimation of Shunt Active Power Filter for Thyristor Converter Load (싸이리스터 컨버터부하에 적용되는 병렬형 능동필터의 적정용량산정)

  • Park, No-Jung;Jeong, Seung-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.12
    • /
    • pp.715-726
    • /
    • 1999
  • This paper estimates the capacity of shunt type active power filters(APF) for harmonic/reactive power compensation with a thyristor converter load. The base capacity requirement of APF is defined for idealized converter load current waveform and the effect of commutation overlap on the APF capacity is examined. The APF capacity required for reactive power compensation in addition to the harmonic elimination is estimated to give maximum achievable power factor for various operating condition of the partially-loaded thyristor converter. The method of current limit of APF is introduced, and it is shown that the APF capacity can be considerably reduced by deliberately limiting the peak current while maintaining the filtering performance to meet the level std 519 regulation.

  • PDF