• Title/Summary/Keyword: current-effect

Search Result 10,222, Processing Time 0.035 seconds

Analysis and Compensation of Current Sampling Error in Discontinuous PWM Inverter for AC Drive (교류 전동기 구동용 불연속 PWM 인버터의 전류 샘플링 오차 해석 및 보상)

  • Song, Seung-Ho;Son, Yo-Chan;Seol, Seung-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.9
    • /
    • pp.517-522
    • /
    • 1999
  • This paper addresses the issue of current sampling in a high performance AC drive system fed by a discontinuous PWM inverter. The effect of the sampling error due to the measurement delay produced by an input stage low pass filter and an A/D converter is described in the case of discontinuous PWM. To compensate for the sampling error, a method to estimate the delay time of the whole measurement system based on the measured current is proposed and its effectiveness is verified by experimental results. The proposed algorithm can automatically estimate the system delay introduced by the low pass filter and the A/D converter at the commissioning stage. By delaying the current sampling by the estimated value, experimental results indicate that more than 50% reduction of current ripple can be achieved.

  • PDF

The Effect of Additives on the Deposition Rate and the Surface Morphology of Trivalent Chromium Electrodeposits (3가 크롬도금의 전착속도 및 표면형상에 미치는 첨가제의 영향)

  • 예길촌;서경훈
    • Journal of the Korean institute of surface engineering
    • /
    • v.37 no.1
    • /
    • pp.13-21
    • /
    • 2004
  • The deposition rate, the current efficiency and surface morphology of trivalent Cr deposits were investigated according to additives in sulfate bath and current density. The deposition rate of the Cr deposits plated from the formic acid complexed bath was noticeably higher than that of the glycine complexed bath. The current efficiency of the deposition from formic acid bath was higher than that of the glycine bath and increased with current density in the range of 20-50 A/d$\m^2$. The current efficiency of the deposition from the formic acid bath with boric acid buffer was higher than that of the bath with aluminum sulfate or boric acid-aluminum sulfate buffers. The nodular crystallite size of the Cr deposits increased with current density and the uniform and crack-free growth of the deposits for the aluminum sulfate was observed compared to the other buffers.

Effect of Current Density and Solution pH on Properties of Electrodeposited Cu Thin Films from Sulfate Baths for FCCL Applications (Sulfate 용액을 이용하여 전기도금 한 FCCL용 Cu 필름의 특성에 미치는 전류밀도와 pH의 영향)

  • Shin, Dong-Yul;Park, Doek-Yong;Koo, Bon-Keup
    • Journal of the Korean institute of surface engineering
    • /
    • v.42 no.4
    • /
    • pp.145-151
    • /
    • 2009
  • Nanocrystalline Cu thin films for FCCL were electrodeposited from sulfate baths to investigate systematically the influences of current density, solution pH on current efficiency, residual stress, surface morphology, and microstructure of thin Cu films. Current efficiencies were measured to be approximately 100%, irrespective of the applied current density and solution pH. But these influenced residual stress, surface morphology, XRD pattern, and grain size of electrodeposited Cu thin film. The residual stress decreased with decreasing the surface roughness, but increased with increasing the fcc(111) peak strength of XRD patterns.

Effect of carrier collector on the Efficiency of DSSCs

  • Ramasamy, Easwaramoorthi;Lee, Won-Jae;Lee, Dong-Yun;Song, Jae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.633-634
    • /
    • 2005
  • Transparent conducting glasses exhibit high ohmic losses that are apparent in the case of large size Dye Sensitized Solar Cells (DSSCs). In this study, we investigated the impact of current collectors over the efficiency of DSSCs. The Silver current collectors were prepared on both counter electrode and working electrode surface by screen printing method. For long term stability in electrolyte environment and also to avoid the charge recombination, current collectors are protected by sodium silicate overcoat layer. These current collectors were characterized for their microstructure parameters. Also current collector's stability in electrolyte environment has been investigated.

  • PDF

Disturbance Observer-based Current Measurement Offset Error Compensation in Vector-controlled SPMSM Drives (표면 부착형 동기 전동기 벡터 제어에서의 외란 관측기 기반 전류 측정 오프셋 오차 보상 방법)

  • Lee, Sang-Min;Lee, Kibok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.402-409
    • /
    • 2022
  • In vector-controlled drive systems, the current measurement offset error causes unwanted torque ripple, resulting in speed and torque control performance degradation. The current measurement offset error is caused by various factors, including thermal drift. This study proposes a simple DC offset error compensation method for a surface permanent magnet motor based on a disturbance observer. The disturbance observer is designed in the stationary reference frame. The proposed method uses only the measured current and machine parameters without additional hardware. The effect of parameter variations is analyzed, and the performance of the current measurement offset error compensation method is validated using simulation and experimental results.

The effect of HRT, current density, and packing ratio on nitrate nitrogen removal efficiency and current efficiency in BRM-BER (고정상 담체를 충진한 BER에서 HRT, 전류밀도 및 담체 충진율 변화가 질산성 질소 제거효율과 전류이용효율에 미치는 영향)

  • Whang, Gye-Dae;Lee, Sang-Keun;Sung, Hae-Chang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.4
    • /
    • pp.433-442
    • /
    • 2010
  • BER at different packing ratios of bio-ring media(BRM) was tested to investigate the effect of varying hydraulic retention time (HRT) and current density on the nitrate removal and current efficiency. In the preliminary batch mode experiment of BERs, current density was applied at 2.0 A/$m^2$, 4.0 A/$m^2$, 4.8 A/$m^2$, which correspond to the designation of reactor #1, #2, #3, respectively. The reactor #2 showed a highest nitrate removal rate of 162.0 mg $NO_3{^-}$-N/L/d, and the kinetics of nitrate removal rate was defined as the Zero order reaction. In the primary experiment of BERs, four BERs packed with BRM were operated in varying HRT and current, and the packing ratios of reactor #1, #2, #3 and #4 were 0%, 8%, 16%, 24%. respectively. This results of the experiments indicated that the nitrate removal rate and current efficiency were increased significantly cause of growing of autotrophic denitrification microorganisms on the surface of cathode and media by increasing of the current density and decreasing of HRT. However, The decreasing of nitrate removal rate and current efficiencies were observed in the condition of HRT of 5.25 hr and 4.8 A/$m^2$ of current density. With more increasing current density and decreasing of HRT, the hydrogen inhibition occurred at the surface of cathode. Moreover, nitrate removal rate by autotrophic denitrification microorganisms attached on the media surface was observed to be limited by no longer increasing dissolved hydrogen concentration of each reactor. In conclusion, the highest nitrate nitrogen removal and current efficiency could be achieved when the BER was operated at the conditions of 7 hr HRT, current density of 4.0 A/$m^2$, and 16% packing ratio. And it was found that the amount of nitrate removal by microorganisms attached on the surface of cathode and media (BRM) was 178.2 mg/L and 52.2 mg/L respectively. and the amount of nitrate removal per MLVSS was 0.435 g $NO_3{^-}$-N/g $MLVSS{\cdot}d$ and 0.336 $NO_3{^-}$-N/g $MLVSS{\cdot}d$.

Effects of the Capacitive Field in an Inductively Coupled Plasma Discharge

  • Choe, HeeHwan
    • Applied Science and Convergence Technology
    • /
    • v.26 no.5
    • /
    • pp.114-117
    • /
    • 2017
  • Plasma characteristics of two-dimensional inductively coupled discharge simulation is investigated. Impedance of an inductively coupled plasma discharge was considered. Voltage drops across antenna coils and current variation between coils made different profiles of plasma characteristics. Importance of the capacitive field effect in some case was analyzed.

Fabrication of Organic Field-Effect Transistors with Low Gate Leakage Current by a Functional Polydimethylsiloxane Layer (PDMS 기능성 박막을 이용한 적은 게이트 누설 전류 특성을 가지는 유기트랜지스터의 제작)

  • Kim, Sung-Jin
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.2
    • /
    • pp.147-150
    • /
    • 2009
  • We present a technique for fabricating low leakage organic field-effect transistors by a functional polydimethylsiloxane (PDMS) layer. The technique relies on the photo-chemical process of conversion of the PDMS to a silicon oxide which provides the selective growth of pentacene thin films. The reduced gate leakage current showed ${\sim}10^{-10}$ A in a linear ($V_d=-5\;V$) and saturation ($V_d=-30\;V$) region at $V_g-V_t>0$.

Experimental Study on Wave Attenuating Effect of a Pneumatic Breakwater by Using a Multiple Parallel Manifold (다중 병렬 분기관을 이용한 압축공기 방파제의 소파효과에 관한 실험적 연구)

  • KIM JONG-WOOK;Shin Hyun-Soo
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.257-262
    • /
    • 2004
  • A series of preliminary model tests are performed to find out the wave attenuating effect of the pneumatic breakwater of environment friendly type, which is a bubble screen generated by releasing compressed air from a submerged multiple parallel manifold Rising bubbles induce vertical current, which produces horizontal currents flowing away from the bubble-screen area in both directions. Near bottom, the corresponding currents flow toward the bubble screen, thus completing the circulation pattern. The surface current moving against the direction of wave propagation causes some attenuation of the waves. It becomes more effective as the relative depth (d/ L) increases (short-period waves in deep water). With the same air-discharge, the multiple parallel manifold can be more effective for the attenuation of longer waves through optimum arrangement of manifold number. installation depth, manifold gap, etc. The pneumatic breakwater will give a wide utilization as a device for protecting harbor facilities and as a simple, mobile breakwater.

  • PDF