• Title/Summary/Keyword: current pulse

Search Result 1,867, Processing Time 0.024 seconds

Characteristics of Plated Bump on Multi-layer Build up PCB by Pulse-reverse Electroplating (Pulse-reverse도금을 이용한 다층 PCB 빌드업 기판용 범프 생성특성)

  • Seo, Min-Hye;Kong, Man-Sik;Hong, Hyun-Seon;Sun, Jee-Wan;Kong, Ki-Oh;Kang, Kae-Myung
    • Korean Journal of Materials Research
    • /
    • v.19 no.3
    • /
    • pp.151-155
    • /
    • 2009
  • Micro-scale copper bumps for build-up PCB were electroplated using a pulse-reverse method. The effects of the current density, pulse-reverse ratio and brightener concentration of the electroplating process were investigated and optimized for suitable performance. The electroplated micro-bumps were characterized using various analytical tools, including an optical microscope, a scanning electron microscope and an atomic force microscope. Surface analysis results showed that the electroplating uniformity was viable in a current density range of 1.4-3.0 A/$dm^2$ at a pulse-reverse ratio of 1. To investigate the brightener concentration on the electroplating properties, the current density value was fixed at 3.0 A/$dm^2$ as a dense microstructure was achieved at this current density. The brightener concentration was varied from 0.05 to 0.3 ml/L to study the effect of the concentration. The optimum concentration for micro-bump electroplating was found to be 0.05 ml/L based on the examination of the electroplating properties of the bump shape, roughness and grain size.

Numerical Analysis of Through Transmission Pulsed Eddy Current Testing and Effects of Pulse Width Variation

  • Shin, Young-Kil;Choi, Dong-Myung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.3
    • /
    • pp.255-261
    • /
    • 2007
  • By using numerical analysis methods, through transmission type pulsed eddy current (PEC) testing is modeled and PEC signal responses due to varying material conductivity, permeability, thickness, lift-off and pulse width are investigated. Results show that the peak amplitude of PEC signal gets reduced and the time to reach the peak amplitude is increased as the material conductivity, permeability, and specimen thickness increase. Also, they indicate that the pulse width needs to be shorter when evaluating the material conductivity and the plate thickness using the peak amplitude, and when the pulse width is long, the peak time is found to be more useful. Other results related to lift-off variation are reported as well.

Practical Implementation of Maximum Power Tracking Based Short-Current Pulse Method for Thermoelectric Generators Systems

  • Yahya, Khalid;Bilgin, Mehmet Zeki;Erfidan, Tarik
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1201-1210
    • /
    • 2018
  • The applications of thermoelectric generators (TEGs) have received a lot of attention both in terms of harvesting waste thermal energy and the need for multi-levels of power. It is critical to track the optimum electrical operating point using DC to DC converters controlled by a pulse that is generated through a maximum power point tracking algorithm (MPPT). In this paper, the hardware implementation of a short-current pulse algorithm has been demonstrated under steady stated and transient conditions. In addition, the MPPT algorithm has been proposed, which is one of the most effective and applicable algorithms for obtaining the maximum power point of TEGs. During this study, the proposed prototype has been validated both analytically and experimentally. It has also demonstrated successful performance, which highlights the claimed advantages of the proposed MPPT solution.

Comparison of the harmonic reduction by using harmonic passive fitters and technique of intervene firing method at the pulse of the 6-pulse phase controlled converter.

  • Wongtongdee, Surached W.;Laohasongkram, Pipat
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.782-785
    • /
    • 2005
  • This article introduces technique to reduce harmonic by using the $5^{th}$ and $7^{th}$ harmonic tune filter and line reactor in the comparison to the technique of intervening firing method at the pulse of the 6-pulse phase-controlled converter in every 1/6 period. The design of the technique introduced in this article is to reduce the harmonic distortion of the current and the voltage resulted from three-phase thyristor phase-controlled converter. The waveform obtained from the experiment was analyzed on the spectrum of the current, voltage and the total harmonic distortion. The double firing method causes zero vectors of output voltage and input current. Designing the mechanism of the converter based on the idea of Park Vector Theory, the number of harmonic distortion in the intervening firing method were compared to those in normal firing method.

  • PDF

Current waveform Control of Pulse MAG Welding Power Source for High Speed Welding of Thin Plates (박판의 고속용접을 위한 펄스MAG 용접전원의 파형제어에 관한 연구)

  • Gu, Heon-Hoe;Kim, Tae-Jin;Kim, Jun-Hong;Lee, Hyeon-U;Jo, Sang-Myeong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.10
    • /
    • pp.571-578
    • /
    • 1999
  • Current waveform control of pulse MAG welding power source is studied so that welding of thin plates may obtain high speed and improved performance. In this paper, waveform control method is proposed, digital controller using DSP is able to control the current waveform precisely. High speed welding of thin plates using pulse MAG welding method is made possible. Performance test for 1.2mm thin plates is carried out, output waveform and welding performance is analyzed.

  • PDF

Pulse-width Adjustment Strategy for Improving the Dynamic Inductor Current Response Performance of a Novel Bidirectional DC-DC Boost Converter

  • Li, Mingyue;Yan, Peimin
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.34-44
    • /
    • 2018
  • This paper presents a pulse-width adjustment (PWA) strategy for a novel bidirectional DC-DC boost converter to improve the performance of the dynamic inductor current response. This novel converter consists of three main components: a full-bridge converter (FBC), a high-frequency isolated transformer with large leakage inductance, and a three-level voltage-doubler rectifier (VDR). A number of scholars have analyzed the principles, such as the soft-switching performance and high-efficiency characteristic, of this converter based on pulse-width modulation plus phase-shift (PPS) control. It turns out that this converter is suitable for energy storage applications and exhibits good performance. However, the dynamic inductor current response processes of control variable adjustment is not analyzed in this converter. In fact, dc component may occur in the inductor current during its dynamic response process, which can influence the stability and reliability of the converter system. The dynamic responses under different operating modes of a conventional feedforward control are discussed in this paper. And a PWA strategy is proposed to enhance the dynamic inductor current response performance of the converter. This paper gives a detailed design and implementation of the PWA strategy. The proposed strategy is verified through a series of simulation and experimental results.

Effects of Interferential Current Stimulation on the Peripheral Blood Velocity in Healthy Subjects (간섭전류자극이 말초 혈류속도에 미치는 영향)

  • Park Jang-Sung;Lee Jae-Hyoung
    • The Journal of Korean Physical Therapy
    • /
    • v.11 no.2
    • /
    • pp.37-42
    • /
    • 1999
  • The purpose of this study was to determine whether percutaneous interferential current stimulation on thoracic sympathetic ganglia with amplitude modulated frequency (AMF) $90\~100$ bps and subthreshold of muscle contraction for 10 minutes on peripheral blood flow velocity in healthy subjects. Thirty-seven healthy volunteers were assigned randomly into an experimental group (n=25) and a control group (n=12). the experimental group received interferential current stimulation with subthreshold of the muscle contraction of current at AMF $90\~100$ bps on $1st\~5th$ thoracic sympathetic ganglial region for 10 minutes. The control group received same handling and electode placement, but no current was applied. Using a Doppler blood flow meter, the radial arterial blood flow velocities and the pulse raters were determined for two-way analysis of variance for repeated measures on time and group. There were no significant difference between the two groups with respect to the changes in arterial blood flow velocity and pulse rate over the four measurement times. Interferential current stimulation did not change in mean blood flow velocity and pulse rate. We conclude that interferential current stimulation on the thoracic sympathetic ganglia, as used in this study, did not dilate peripheral artery. This results suggests that interferential current stimulation dose not alter the activtiy of sympathetic nerve.

  • PDF

THE EFFECT OF PULSE CURRENT ON THE CURRENT EFFICIENCY OF CHROMIUM PLATING IN SRHS BATH

  • Han S.H;Kwon S.C.
    • Journal of the Korean institute of surface engineering
    • /
    • v.19 no.2
    • /
    • pp.59-64
    • /
    • 1986
  • Pulse current was empolyed to the chromium electroplating bath of self-regulating high speed in the following range of conditions; 10-80$^{\circ}C$, 0-400A/$dm^2$, 10-100KHz. The current efficiency was compared with that of a conventional direct current plating in respect of current density and electrode interdistance. The effect of pulse current was found to increase the current efficiency at least 10-20 percent more than the conventional direct current plating in the high current density more than 100A/$dm^2$ and at 3-4mm of electrode interdistance. The surface appearance was also studied and known to be of great influenced by pulse frequency.

  • PDF

The development of laser system for cancer (암치료용 레이저 시스템 개발)

  • 이동진;김주명;김선학;임현수
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.08a
    • /
    • pp.154-155
    • /
    • 2001
  • A laser system for therapy of cancer is proposed in this paper. In order to accuracy and statistical output control we used the constant current control method and designed the power source to protect the resonator from the over -current, rush-current and electrical fault. The most important things are the radiation type for cancer therapy in laser system, we developed the radiation type of cw, pulse, and burst pulse. The experimental result show that laser beam power increase linearly from 100mW to 300mW for input current increasing and the exposure time.

  • PDF

Harmonic Reduction of Three Phase Multi-Pulse Converter Circuit without Input Transformer (입력 변압기 없는 3상 멀티-펄스 콘버터의 고조파 저감)

  • Park, Hyun-Chul;Kim, Yeong-Min;Hwang, Jong-Sun;Kim, Jong-Man
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.128-131
    • /
    • 2002
  • In this paper, a new method for reducing harmonic in input AC line currents of converter presents, which is the multi-pulse converter circuit without the input transformer. This system can reduce the harmonic like conventional 12-pulse converter. Both the bridge circuits are controlled with the shifted firing angle and connected 2 tap inter-phase reactor. Using 2 tap changing on inter-phase reactor, the input current is controlled with the different two values in order to make the input current waveform 12 pulses.

  • PDF