• Title/Summary/Keyword: current pulse

Search Result 1,867, Processing Time 0.031 seconds

Characteristics in W-EDM of Tungsten Carbide (초경합금의 와이어 방전가공에 의한 특성)

  • 맹민재
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.4
    • /
    • pp.7-13
    • /
    • 2001
  • Wire electrical discharge machining experiments in conducted to investigate characteristics of acoustic emission (AE) and electrical discharge energy due to current peak (I$_{p}$), pulse on time($\tau$/on/). The AE signals are obtained with a sensor attached to workpiece side. Machining states are identified with scanning electron microscopy and residual stress analyzer. It is demonstrated that the residual stress provide reliable informations about the machining states. Moreover, machining states can be detected successfully using both the residual stress and AE count rate.e.

  • PDF

A Study on the Design of Branch Conductor in the Magnetic Pulse Generator (자기 펄스 발생기의 연결 도체 설계에 관한 연구)

  • SUH, JUBA
    • Journal of Industrial Technology
    • /
    • v.9
    • /
    • pp.101-107
    • /
    • 1989
  • The magnetic forming system must be able to store very important electric energy, several tens kilojoules, and flow this energy through the forming coil within some hundreds microseconds. So several hundreds kiloamperes of current can flow through the branch conductor. For the good performance of this type of machine, internal impedance must be minimized. By the computation of distribution of current inside the conductors using integral equation method, we can obtain the inductance and resistance of some dispositions of branch conductors and by comparison obtain some principles for the design of branch conductors in the high power magnetic pulse generator.

  • PDF

A Basic Study on Electrical Discharge Machining (방전 가공의 기초적 연구)

  • 김해종;마대영;김상현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.05a
    • /
    • pp.42-45
    • /
    • 1994
  • In this paper, we will report on the effect of the pointed end shape of an electrode, discharge energy, pulse width and discharge current on machining characteristics. The results obtained are as tollows: 1)As the discharge Energy increases, the diameter and the depth of the discharged crater becomes larger and deeper. 2) The discharge energy is not constant during discharge but varies depending on the pointed end shape of th8 electrode. 3) The shape of crater depends on the pulse width and discharge current.

  • PDF

Quench characteristics of bare and of-laminated YBCO-coated conductor (YBCO 고온초전도체의 \ulcorner치특성 연구)

  • Kim Ho-Min;Park Kwon-Bae;Lee Bang-Wook;Oh Il-sung;LEE Hai-gun;Iwasa Yukikazu
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.3
    • /
    • pp.1-5
    • /
    • 2004
  • This paper presents a study on the stability of bare and cu-laminated YBCO-coated conductor. we investigate the characteristics of quench/recovery behavior of YBCO test samples. bare and copper-laminated, by subjecting each test sample. immersed in a bath of liquid nitrogen boiling at 77.3 K. to a transport current pulse superimposed to a baseline DC current of 90-95% the critical current. The current pulse has an amplitude up to ∼4.5 times the critical current and a duration of 300 ms. This paper presents both experimental and simulation results.

Dynamic Power Supply Current Testing for Open Defects in CMOS SRAMs

  • Yoon, Doe-Hyun;Kim, Hong-Sik;Kang, Sung-Ho
    • ETRI Journal
    • /
    • v.23 no.2
    • /
    • pp.77-84
    • /
    • 2001
  • The detection of open defects in CMOS SRAM has been a time consuming process. This paper proposes a new dynamic power supply current testing method to detect open defects in CMOS SRAM cells. By monitoring a dynamic current pulse during a transition write operation or a read operation, open defects can be detected. In order to measure the dynamic power supply current pulse, a current monitoring circuit with low hardware overhead is developed. Using the sensor, the new testing method does not require any additional test sequence. The results show that the new test method is very efficient compared with other testing methods. Therefore, the new testing method is very attractive.

  • PDF

Analysis, Design, and Implementation of a High-Performance Rectifier

  • Wang, Chien-Ming;Tao, Chin-Wang;Lai, Yu-Hao
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.905-914
    • /
    • 2016
  • A high-performance rectifier is introduced in this study. The proposed rectifier combines the conventional pulse width modulation, soft commutation, and instantaneously average line current control techniques to promote circuit performance. The voltage stresses of the main switches in the rectifier are lower than those in conventional rectifier topologies. Moreover, conduction losses of switches in the rectifier are certainly lower than those in conventional rectifier topologies because the power current flow path when the main switches are turned on includes two main power semiconductors and the power current flow path when the main switches are turned off includes one main power semiconductor. The rectifier also adopts a ZCS-PWM auxiliary circuit to derive the ZCS function for power semiconductors. Thus, the problem of switching losses and EMI can be improved. In the control strategy, the controller uses the average current control mode to achieve fixed-frequency current control with stability and low distortion. A prototype has been implemented in the laboratory to verify circuit theory.

Study on Pulse Simulator of Oriental Medicine for Objective Structured Clinical Examination (OSCE) (한의학 객관구조화진료시험(OSCE)을 위한 진맥 시뮬레이터 개념 연구)

  • Kim, Kyoung-Shin;Kim, Kyoung-Ho;Choi, Chan-Hun;Lee, Soo-Jin;Kim, Byoung-Soo
    • The Journal of Korean Medicine
    • /
    • v.32 no.1
    • /
    • pp.1-11
    • /
    • 2011
  • Objectives: The aim of this study was to examine the controversial issues about objective structured clinical examination (OSCE) of pulse diagnosis and investigate the objectification of traditional Korean medicine and technical feasibility of pulse simulation through the suggestion of a pulse simulator. Methods: The concept, validity and reliability of OSCE and the current situation of medical simulation was described. The actual level and problems on the simulator development was presented through haptics and tactile technology in order to compose a pulse simulator for OSCE. Results: The pulse wave system of a pulse simulator should materialize through haptic technology and the classification of the differences between tactile sensation and tactile quality is essential for the development of the relevant pulse simulator for OSCE in traditional Korean medicine. Conclusions: The introduction and controversial issues of OSCE and methodology of pulse wave reappearance system are proposed for the objectification of Traditional Korean Medicine and the development of clinical technology.

Numerical Analysis of Intense Electric Current Pulse to Disperse Shaped Charge Metal Jet (성형작약탄 금속제트 산란을 위한 대전류 펄스의 수치해석적 연구)

  • Park, Hyeong Gyu;Kim, Dong Kyu;Kim, Si Woo;Joo, Jae Hyun;Song, Woo Jin;Kim, Jeong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.1
    • /
    • pp.55-62
    • /
    • 2015
  • The electromagnetic force induced by an intense electric current pulse, which generates an electromagnetic field around the metal jet originating from a shaped charge, can disperse and scatter the high-speed metal jet. An electric device consisting of an RLC circuit applies an intense electric current pulse that flows in the circuit while the metal jet passes between two electrodes. In this study, the metal jet formation was simulated using the ALE technique in 2-D, and a 3-D finite element model was mapped using 2-D simulation results to induce the electric current directly. The deformed shapes of the metal jet and the electromagnetic force were calculated using a finite element analysis by inducing the electric current directly, and the major parameters of the intense electric current pulse for breaking up the metal jet were examined.

Influence on Metal Removal Rate by Material and Size Difference of the Electrode (전극의 재료와 크기가 방전가공량에 미치는 영향)

  • 김희중
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.809-815
    • /
    • 1998
  • This study has been performed to investigate MRR(metal removal rate) surface roughness with various pulse-on duration using the copper and graphite electrode according to the electrode size on the heat treated STD 11 which is extensively used for metallic molding steel in the EDM. The results obtained are as follow ;a)MRR increases a lot when pulse-on duration is 100 $\mu{s}$ or less but MRR has little difference with pulse-on duration of 100 $\mu{s}$ or more b) According to the increase of Pulse-on duration the large the electrode size the more MRR c) Safe discharge is needed to make maximum of MRR and the metallic organization must be complicated for discharge induction. d) Actual machining time is longer than theoretical machining time at the short pulse-on duration because of skin effect of current. e) Graphite electrode needs the larger electric discharge energy than copper electrode to remove remained chips completely.

  • PDF