• Title/Summary/Keyword: current detecting

Search Result 758, Processing Time 0.028 seconds

Analysis on the Degradation of Insulators using Corona Camera (코로나 카메라를 이용한 불량애자 검출사례 분석)

  • Kim, H.S.;Kim, P.H.;You, Y.K.;Koo, K.W.;Kim, H.J.;Kim, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.132-134
    • /
    • 2003
  • Insulator that is used in electric power equipment superannuation and being damaged disorder can. Such as defected insulator has repair or change must because defective influence in electrical equipment. There are many method developed for detecting the defected insulators, analyzed various test of devide voltage, electric field, ultrasonic and discharge pulse. But methods of detecting ultrasonic of discharge, electric field or leakage current could not application in the field, In this paper, we compare the advantage and the limitation of the method to detect defected insulator, and wish proposed using corona camera.

  • PDF

Event Log Validity Analysis for Detecting Threats by Insiders in Control System

  • Kim, Jongmin;Kang, Jiwon;Lee, DongHwi
    • Journal of information and communication convergence engineering
    • /
    • v.18 no.1
    • /
    • pp.16-21
    • /
    • 2020
  • Owing to the convergence of the communication network with the control system and public network, security threats, such as information leakage and falsification, have become possible through various routes. If we examine closely at the security type of the current control system, the operation of the security system focuses on the threats made from outside to inside, so the study on the detection system of the security threats conducted by insiders is inadequate. Thus, this study, based on "Spotting the Adversary with Windows Event Log Monitoring," published by the National Security Agency, found that event logs can be utilized for the detection and maneuver of threats conducted by insiders, by analyzing the validity of detecting insider threats to the control system with the list of important event logs.

Literature Review on Recent Magnetocardiography and Impedance-Magnetocardiography Technologies

  • Kandori, A.;Miyashita, T.;Ogata, K.;Seki, Y.;Suzuki, D.;Tsukamoto, A.;Saito, K.;Yokosawa, K.;Tsukada, K.;Yamada, Satsuki;Watanabe, Shigeyuki;Horigome, Hitoshi;Yamaguchi, Iwao
    • Progress in Superconductivity
    • /
    • v.8 no.1
    • /
    • pp.1-7
    • /
    • 2006
  • We have developed magnetocardiography(MCG) and impedance magnetocardiography(I-MCG) for detecting heart disease by using dc-SQUID technology. The MCG system, using low-Tc SQUID, is being applied commercially for diagnosing heart disease. Using the low-Tc MCG system, many clinical studies on detection of abnormality have been performed. Furthermore, we have developed a portable MCG system using high-Tc SQUID. For detecting changes in kinetic impedance in the heart, an I-MCG system has been demonstrated. The I-MCG system could detect the mechanical movement of the heart. In this report, we review current clinical applications of magnetocardiography and impedance magnetocardiography.

  • PDF

The Study on the Correlation of Vibration, Wear and Temperature for Rubbing in Rotating Machinery (마멸현상에서 발생하는 회전기 시스템의 진동.마모.온도의 상관 관계 연구)

  • 백두진;김승종;윤의성;김창호;공호성;장건희;이용복
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.453-459
    • /
    • 2002
  • In this paper. the correlation among vibration. wear and temperature are experimentally investigated when rubbing is caused by static and dynamic forces. Each measurement reflects the characteristics of the system and is useful in detecting and diagnosing the current status of rotating machinery. For experiment, the rotor system with lubricating equipment such as trochoid pump, oil tank and wear detecting sensor is implemented to simulate the rubbing condition. Experimental results show that significant change in wear quantity can be notified when vibration signal is changed by rubbing. The results can be applied to system monitoring and fault diagnosis in rotating machinery.

  • PDF

A Study on the Fault Diagnosis of Rotor Bars in Squirrel Cage Induction Motors by Finite Element Method (유한요소법을 이용한 농형유도전동기의 회전자 불량 진단에 관한 연구)

  • 김창업;정용배
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.5
    • /
    • pp.287-293
    • /
    • 1996
  • The squirrel cage rotors of induction motors may have several faults such as broken bars, bad spots in end ring and abnormal skew caused by improper processing. These faults may cause bad effects on the performance of the induction motor. This paper proposes the detecting technique of these faults by analyzing the induced current of the detecting electric magnet, using 2-D finite element method taking account of the rotor movement.

  • PDF

CURRENT STATUS OF INTEGRITY ASSESSMENT BY SIPPING SYSTEM OF SPENT FUEL BUNDLES IRRADIATED IN CANDU REACTOR

  • Park, Jong-Youl;Shim, Moon-Soo;Lee, Jong-Hyeon
    • Nuclear Engineering and Technology
    • /
    • v.46 no.6
    • /
    • pp.875-882
    • /
    • 2014
  • In terms of safety and the efficient management of spent fuel storage, detecting failed fuel is one of the most important tasks in a CANada Deuterium Uranium (CANDU) reactor operation. It has been successfully demonstrated that in a CANDU reactor, on-power failed fuel detection and location systems, along with alarm area gamma monitors, can detect and locate defective and suspect fuel bundles before discharging them from the reactor to the spent fuel storage bay. In the reception bay, however, only visual inspection has been used to identify suspect bundles. Gaseous fission product and delayed neutron monitoring systems cannot precisely distinguish failed fuel elements from each fuel bundle. This study reports the use of a sipping system in a CANDU reactor for the integrity assessment of spent fuel bundles. The integrity assessment of spent fuel bundles using this sipping system has shown promise as a nondestructive test for detecting a defective fuel bundle in a CANDU reactor.

Performance Evaluation of Conflict Detection Schemes for Concurrent Temporal Tranactions (시간지원 크랙잭션을 위한 충돌 검출 기법의 성능평가)

  • 구경이;하봉옥;김유성
    • Journal of KIISE:Software and Applications
    • /
    • v.26 no.1
    • /
    • pp.80-80
    • /
    • 1999
  • As Temporal DataBase Systems(TDBSs) manages both the historical versions and the current version of each data item, a temporal transaction may access more data records than atransaction in traditional database systems. Hence, the concurrency control subsystem of temporaldatabase management system should be able to correctly and efficiently detect actual conflicts amongconcurrent temporal transactions while the cost of detecting conflicts is maintained in low levelwithout detecting false conflicts which cause severe degradation of system throughput.In this paper, Two-Level Conflict Detection(TLCD) scheme is proposed for efficient conflictdetection between concurrent temporal transactions in TDBs. In the proposed TLCD scheme, sincechecking conflict between concurrent temporal transactions is performed at two levels, i, e., logicallevel and physical level, conflicts between concurrent temporal transactions are efficiently and correctlydetected,Furthermore, we also evaluate the performance of the proposed TLCD scheme with those oftraditional conflict detection schemes, logical-level conflict detection scheme and physical-level conflictdetection scheme by simulation approach, The result of the simulation study shows that the proposedTLCD scheme outperforms the previous conflict detection schemes with respect to the averageresponse time.

New leakage detection system for the hydraulic system of EHV underground oil-filled cables (초고압 OF 케이블 급유계통의 조기이상검지시스템)

  • Kim, Y.;Seong, J.K.;Han, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1966-1968
    • /
    • 2000
  • Globally, oil-filled paper-insulated cables and cross-linked polyethylene-insulated cables have been mainly applied for a underground power transmission line. The oil-filled cable has the hydraulic system in which insulating oil, expanded and contracted by temperature changes, is absorbed and supplied. This system enable us to detect oil leakages from the cable. But it has some problems such as difficulty in detecting minor leakages and a relatively long period of fault detecting. And so, this paper introduce a new leakage detection system, improved from the current one.

  • PDF

Development of Wireless lightning detecting and warning system (무선식 낙뢰통보시스템 개발)

  • Kim, Kyung-Man;Kwon, Tae-Woon;Sim, Kwang-Yeol;Kim, Se-Yeol
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.500-503
    • /
    • 2006
  • This paper gives a Wireless lightning detecting and warning system. This system composed of transmitter and receiver. It promptly senses lightning strikes on the power lines and transmission towers by using the lightning current detection circuit in a small transmitter situated on the top of power tower, and it sends the number of lightning strikes and the ID. of the tower to patrols through the receivers. This system will be used to discover the exact location of a lightning strike.

  • PDF

The detection of Broken Rotor Bars in Squirrel Cage Induction Motors (농형 유도전동기의 회전자 도체 불량 검출 방법)

  • Im, Dal-Ho;Kim, Chang-Eob;Jung, Yong-Bae;Kwon, O-Mun;Park, Byung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.65-67
    • /
    • 1995
  • The squirrel cage rotors for induction motors may have several faults such as broken bars, bad spots in end ring, abnormal skew caused by improper processing. These faults have bad effect on the performance of the induction motor. This paper proposes the detecting technique of these faults by analyzing the current of the detecting electric magnet, using 2-D finite element method taking account of the rotor movement.

  • PDF