• Title/Summary/Keyword: current design criteria

Search Result 503, Processing Time 0.025 seconds

LOAD COMBINATION CRITERIA FOR DESIGN OF NPP COINTAINMENT STRUCTURES (원자력 차폐 구조물의 설계하중 조합 규준)

  • Han, Bong-Koo;Cho, Hyo-Nam
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1989.10a
    • /
    • pp.19-24
    • /
    • 1989
  • The current load combination criteria for design of nuclear power plant structures are not based on the probability-based design concept but rely on the conventional design concept. In this paper, a load combination criteria for design of NPP coin-tainment structures are proposed based on a FEM-based random vibration analysis. More accurate reliability analyses under various dynamic loads such as earthquake loads were made possible by incorporating the FEM and random vibration theory, which is different from the conventional reliability analysis method. In this paper, the load factors for the design of NPP structures in Korea are proposed by considering appropriate fond combination criteria for design.

  • PDF

Optimum Design Criteria for Maximum Torque Density & Minimum Current Density of a Line-Start Permanent-Magnet Motor using Response Surface Methodology & Finite Element Method (반응표면법과 유한요소법을 이용한 라인-스타트 영구 자석 전동기의 최대토크밀도와 최소전류밀도을 위한 최적설계)

  • Jang, Soon-Myung;Jun, Myung-Jin;Lee, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1055-1056
    • /
    • 2011
  • This paper deals with optimum design criteria for maximum torque density & minimum current density of a single phase line-start permanent-magnet motor (LSPMM) using RSM (Response Surface Methodology) & FEM (Finite Element Method). The focus of this paper is to find a design solution through the comparison of torque density and minimum current density resulting from rotor shape variations. And then, a central composite design (CCD) mixed resolution is introduced, and analysis of variance (ANOVA) is conducted to determine the significance of the fitted regression model.

  • PDF

Design Criteria for Effective Public Building Construction Process (공공청사의 효율적 조성을 위한 건축디자인 기준 설정 연구)

  • Kim, Chang-Shin;Dong, Jae-Uk;Lee, Hwa-Ryong
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.13 no.1
    • /
    • pp.43-53
    • /
    • 2013
  • The purpose of this study is to propose the reasonable method for effective public building construction process. Public building service administration is necessary to make efficient public building supply and demand program. As a result, current public building precess need four steps(organize public assets, various process, establish public building service administration, design criteria). 1. Planning phase : Participation of Private Experts is guaranteed to enhance public building's function such as welfare, entertainment. 2. Design Phase : Detailed design review makes efficient and user oriented public building. 3. Construction Phase : Public Architect solve various problems among the participator especially in case of government local building construction. In conclusion, well formulated design criteria and Public building service administration make public building efficient in various field.

Load Combination Criteria for Dsing of NPP Containment Structures (원자력 차폐구조물의 설계하중 조합 규칙)

  • 한봉구;조효남
    • Computational Structural Engineering
    • /
    • v.3 no.1
    • /
    • pp.51-57
    • /
    • 1990
  • The current load combination criteria for design of nuclear power plant structures(NPP) are not based on the probability-based design concept but rely on the conventional design concept. In this paper, a load combination criteria for design of NPP containment structures are proposed based on a FEM-based random vibration analysis. More accurate reliability analyses under various dynamic loads such as earthquake loads were made possible by incorporating the FEM and random vibration theory, which is different from the conventional reliability analysis method, In this paper, the toad factors for the design of NPP structures in Korea are proposed by considering appropriate load combination criteria for design.

  • PDF

Reliability-Based Structural Optimization of Transmission Tower (신뢰성에 기초한 철탑구조물의 최적화에 관한 연구)

  • 김성호;김상효;황학주
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1993.04a
    • /
    • pp.135-140
    • /
    • 1993
  • The optimum weight design of structure is to determine the combination of structural members which minimize the weight of structures and satisfy design conditions as well. Since most of loads and design variables considered in structural design have uncertain natures, the reliability-based optimization techniques need to be developed. The aim of this study is to estabilish the general algorithm for the minimum weight design of transmission tower structure system with reliability constraints. The sequential linear programming method is used to solve non-linear minimization problems, which converts original non-linear programming problems to sequential linear programming problems. The optimal solutions are produced for various reliability levels such as reliability levels inherent in current standard transmission tower cross-section and optimal transmission tower cross-section obtained with constraints of current design criteria as well as selected target reliability index. The optimal transmission towers satisfying reliability constraints sustain consistent reliability levels on all members. Consequently, more balanced optimum designs are accomplished with less structural weight than traditional designs dealing with deterministic design criteria.

  • PDF

Structural Analysis of Underground Parking Garage Under Vehicle Load (지하주차장 차량하중에 따른 구조체의 영향분석)

  • Kim, Young-Jin;Lee, Bum-Sick;Choi, Dong-Sub;Oh, Hyo-Keon;Kang, Chang-Bum
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.4 no.4
    • /
    • pp.22-29
    • /
    • 2013
  • Accumulation of more than 20,000,000 vehicles since the establishment of the quality of life and economic development needs several parking lots and cause crack problem in Korea. Related structures in large cities due to the lack of parking garage attached to secure underground parking structures are actively being built, and the basement parking lot will continue to increase more stories and the trend is expected to be larger. But so far, construction of the underground parking structure is related to a number of problems, including cracks in the structure. Therefore, in this study, repair, reinforcement and a few non-economic losses in the current design criteria are presented. The review of the structure used to current design criteria is to minimize crack and maximize usability.

Structural Performance of 800 MPa High-Strength Steel Members and Application to Highrise and Mega Building Structures

  • Lee, Cheol-Ho
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.3
    • /
    • pp.249-259
    • /
    • 2017
  • The use of high-strength steels in construction of highrise and mega building structures can bring about many technological advantages from fabrication to erection. However, key design criteria such as local and lateral stability in current steel design specifications were developed based on tests of ordinary steels which have stress-strain characteristics very different from that of high strength steels. A series of tests on 800 MPa tensile strength steel (HSA800) members are summarized in this paper which were conducted to investigate the appropriateness of extrapolating current ordinary-steel based design criteria to high strength steels. 800 MPa I-shape beam specimens designed according to flange local buckling (FLB) criteria of the AISC Specification developed a sufficient strength for elastic design and a marginal rotation capacity for plastic design. It is shown that, without introducing distinct and significant yield plateau to the stress-strain property of high-strength steel, it is inherently difficult to achieve a high rotation capacity even if all the current stability limits are met. 800 MPa I-shape beam specimens with both low and high warping rigidity exhibited sufficient lateral torsional buckling (LTB) strength. HSA800 short-column specimens with various edge restraint exhibited sufficient local buckling strength under uniform compression and generally outperformed ordinary steel specimens. The experimental P-M strength was much higher than the AISC nominal P-M strength. The measured residual stresses indicated that the impact of residual stress on inelastic buckling of high-strength steel is less. Cyclic seismic test results showed that HSA800 members have the potential to be used as non-ductile members or members with limited ductility demand in seismic load resisting systems. Finally, recent applications of 800 MPa high strength steel to highrise and mega building structures in Korea are briefly presented.

A Study on Universal Design Guideline of the Urban Railway Station: Platform (도시철도 역사 승강장의 유니버설 디자인 기준에 관한 연구)

  • Kang, Byoung Keun;Kim, Sang Woon;Shin, Dong Hong;Lee, Joo Hyung;Lee, Ju Yeon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.21 no.2
    • /
    • pp.35-43
    • /
    • 2015
  • Purpose: A large number of the mobility impaired have increasingly used the railway station, so the application of UD(Universal Design) on urban railway station has been interested. However, the current criteria used in domestic areas have concerned about the effective administration of railway station facilities rather than the needs of he mobility impaired. Of diverse facilities in railway station, the platform is considered as an important space due to many transportation users' riding or transfer in railway stations. Therefore, this study aims to explore the detailed criteria in adapting ideas from UD to platform within railway station. Methods: This study explores the criteria by evaluating findings from previous studies. First, all criteria related to platform in domestic and foreign areas are taken together and analyzed, and appropriate criteria first are established. Based on these, the current situation of platform facilities in railway station is evaluated. Then, the detailed criteria applicable to railway station platform are concluded, by reviewing types of the mobility impaired and principles of UD. Result: Findings from this study are as follows. First, the current criteria applied to railway station platforms lack ideas of UD, while the criteria used in foreign countries adequately reflect the ideas of UD on railway station platforms; therefore, the better criteria applicable to platform facilities in domestic railway station are necessary. Second, standard criteria used in domestic areas with newly additional criteria suggest that platform facilities should be established according to those criteria. Taken together, the better platform facilities should be provided to railway users through the application of UD to railway station platforms. Implications: For the future users in railway station platforms, the additional research on criteria of UD as well as diverse types of spaces within railway stations should have been continued.

Evaluation of Sidewalk Level of Service Considering Land Use Patterns (용도지역 특성을 고려한 보도 설계 서비스수준 평가방안)

  • Kim, Yong-Seok;Choe, Jae-Seong
    • Journal of Korean Society of Transportation
    • /
    • v.25 no.2 s.95
    • /
    • pp.83-93
    • /
    • 2007
  • Pedestrians and vehicle users should be treated with equal importance in urban street design. However, current street design suggests that the design criteria for sidewalks is based on the functional hierarchy of the vehicles, therefore it is necessary to develop sidewalk design standards that give more weight to pedestrians rather than vehicles. For this, this study suggests that the level of service of pedestrians should be considered in the process of designing sidewalks. Currently, level of service (LOS) criteria for pedestrians in the Korean Highway Capacity Manual are based on pedestrian volume, but the volume of pedestrians is seldomly estimated in practice. So, the current LOS criteria has limitations in terms of practical use. Also, the study assumes that the pedestrian flow rate is hardly the dominant factor that could affect the LOS of pedestrians at most urban sidewalks. In this context, the study considers a new LOS for sidewalk design based on the comfort of pedestrians while passing pedestrians coming from the opposite direction. Then the study attempts to link the new LOS criteria to the land use patterns using data of pedestrian traffic characteristics acquired from the field. In addition to this, the scope in which the suggested criteria can be applied is suggested.

Case Studies on the Application of Universal Design Concept to Kitchen Planning (유니버설 디자인 개념을 적용한 부엌 계획을 위한 사례 연구)

  • Oh, Kyung-A;Kwon, Oh-Jung
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.360-363
    • /
    • 2008
  • The purpose of this study was to evaluate current usages and situations of kitchen with regard to universal design concept in order to provide useful data to plan universally designed kitchen space for all family members. Previous studies for universal design and kitchen planning were reviewed and a checklist was developed to evaluate kitchen space based on universal design concept by researchers of this study. Also, all items in the checklist were reclassified by 5 universal design criteria(Supportiveness, Adaptability, Communicability, Pleasantness, and Accessibility) and analyzed sample kichens by the criteria. The 7 households with different characteristics*age, sex, degree of disability or aging, and number of family) were selected for case studies. The results of this study suggested several critical design points to establish directions or provide guidelines for further kitchen planning.

  • PDF