• Title/Summary/Keyword: current account

검색결과 1,189건 처리시간 0.027초

구조물의 손상 상태에 따른 보강설계법 연구 (The Strengthening Desing Method Considering Damages of Structure)

  • 한만엽;이택성
    • 콘크리트학회논문집
    • /
    • 제11권3호
    • /
    • pp.35-45
    • /
    • 1999
  • Recently, many strengthening methods are developed to repair damaged structures, especially, steel plate or carbon fiber sheet bonding methods are widely used. For the bonding methods, the strengthening materials are bonded when the original structure is under loading, which causes difference of initial stresses between original member and bonded material. However, current design method or theory, which mostly depends on ultimately strength design, cannot account the difference of initial stresses between members, and it disregards the reduction of nominal strength. In this study, a new strengthening design theory and program which can account the difference of initial stresses are developed, and applied to the case when a structure in service is repaired. In order to verify the validity of the theory and the program, a test result is referred and compared with the results and it is showed that the calculated values are almost same as the referred data and finally proved that the program is reliable. The results showed that the amount of strengthening material depends on the status of damages of structure, and the nominal strength is reduced depending on the degree of damages.

간접냉각이 이용된 지중송전케이블의 적정냉각조건에 관한 연구 (A Study on the Optimum Cooling Condition of the Underground Power Transmission Cable Equipped with a Separate Pipe Cooling System)

  • 박만흥;최규식;서정윤;김재근;이재헌
    • 설비공학논문집
    • /
    • 제4권4호
    • /
    • pp.263-276
    • /
    • 1992
  • The transmission current in a power cable is determined under the condition of separate pipe cooling. To this end, the thermal analysis is conducted with the standard condition of separate pipe cooling system, which constitutes one of the underground power transmission system. The changes of transmission current in a power cable with respect to the variation of temperatures and flow rates of inlet cooling water as well as the cooling spans are also determined. As a consequnce, the corresponding transmission current is shown to vary within allowable limit, resulting in the linear variation of the current for most of the cable routes. The abrupt changes of current, however, for the given flow rate of inlet cooling water in some cooling span lead to the adverse effects on the smooth current transmission within the underground power transmission system. In practice, it is expected that the desinging of the separate pipe cooling system in conjunction with the evaluation of system capacity should take into account the effects of design condition on the inlet cooling flow rate.

  • PDF

Steady-State Current Characteristics for Squirrel Cage Induction Motor according to Design Variables of Rotor Bars using Time Difference Finite Element Analysis

  • Kim, Young Sun
    • Journal of Magnetics
    • /
    • 제22권1호
    • /
    • pp.104-108
    • /
    • 2017
  • Induction motors have wide applicability in many fields, both in industrial sectors and households, for their advantages of a high efficiency and robust structure. The introduction of power-source-containing harmonics into the induction motor winding lowers its efficiency and increases its temperature, greatly affecting its operation characteristics. In this study, we performed an electromagnetic field analysis using the time-difference finite-element method with the purpose of analyzing the steady-state current characteristics of an induction motor. Additionally, we calculated the steady-state current with a method combining an electromagnetic field equation and a circuit equation. In the electromagnetic field analysis, the nonlinearity was taken into account using the Newton-Raphson method, and a backward time-difference method was employed for the time derivative term. Then, we compared the steady-state current of the induction motor obtained by calculation with the experimentally measured values, thus validating the proposed algorithm. Furthermore, we analyzed the impacts of the shape and material of the rotor conductor bar of the induction motor on the steady-state current of the main winding.

Analysis of Magnetic Dipole Moment for a 300-W Solar-Cell Array

  • Shin, Goo-Hwan;Kim, Dong-Guk;Kwon, Se-Jin;Lee, Hu-Seung
    • Journal of Astronomy and Space Sciences
    • /
    • 제36권3호
    • /
    • pp.181-186
    • /
    • 2019
  • The attitude information of spacecraft can be obtained by the sensors attached to it using a star tracker, three-axis magnetometer, three-axis gyroscope, and a global positioning signal receiver. By using these sensors, the spacecraft can be maneuvered by actuators that generate torques. In particular, electromagnetic-torque bars can be used for attitude control and as a momentum-canceling instrument. The spacecraft momentum can be created by the current through the electrical circuits and coils. Thus, the current around the electromagnetic-torque bars is a critical factor for precisely controlling the spacecraft. In connection with these concerns, a solar-cell array can be considered to prevent generation of a magnetic dipole moment because the solar-cell array can introduce a large amount of current through the electrical wires. The maximum value of a magnetic dipole moment that cannot affect precise control is $0.25A{\cdot}m^2$, which takes into account the current that flows through the reaction-wheel assembly and the magnetic-torque current. In this study, we designed a 300-W solar cell array and presented an optimal wire-routing method to minimize the magnetic dipole moment for space applications. We verified our proposed method by simulation.

Internal Model Control of UPS Inverter using Resonance Model

  • Park J. H.;Kim D. W.;Kim J. K.;Lee H. W.;Noh T. K.;Woo J. I.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.184-188
    • /
    • 2001
  • In this paper, a new fully digital control method for single-phase UPS inverter, which is based on the double control loop such as the outer voltage control loop and inner current control loop, is proposed. The inner current control loop is designed and implemented in the form of internal model control and takes the presence of computational time-delay into account. Therefore, this method provides an overshoot-free reference-to-output response. In the proposed scheme, the outer voltage control loop employing P controller with resonance model implemented by a DSP is introduced. The proposed resonance model has an infinite gain at resonant frequency, and it exhibits a function similar to an integrator for AC component. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been demonstrated by the simulation and experimental results respectively.

  • PDF

Intermittent Heating and Cooling Load Calculation Method -Comparing with ISO 13790

  • Lee, Sang-Hoon
    • Architectural research
    • /
    • 제14권1호
    • /
    • pp.11-18
    • /
    • 2012
  • College of Architecture, Georgia Institute of Technology, Atlanta, GA, US Abstract The intermittent heating and cooling energy need calculation of the ISO 13790 monthly method was examined. The current ISO 13790 method applies a reduction factor to the continuous heating and cooling need calculation result to derive the intermittent heating and cooling for each month. This paper proposes a method for the intermittent energy need calculation based on the internal mean temperature calculation. The internal temperature calculation procedure was introduced considering the heat-balance taking into account of heat gain, heat loss, and thermal inertia for reduced heating and cooling period. Then, the calculated internal mean temperature was used for the intermittent heating and cooling energy need calculation. The calculation results from the proposed method were compared to the current ISO 13790 method and validated with a dynamic simulation using EnergyPlus. The study indicates that the intermittent heating and cooling energy need calculation method using the proposed model improves transparency of the current ISO 13790 method and draws more rational outcomes in the monthly heating and cooling energy need calculation.

노즐용삭을 고려한 SF6 가스차단기 노즐의 열적회복특성 해석 (Analysis of Thermal Recovery Characteristics for Nozzle of SF6 GCB Considering Nozzle Ablation)

  • 이병윤;송기동;정진교;박경엽
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권2호
    • /
    • pp.76-82
    • /
    • 2005
  • In this paper, a method for analyzing the thermal recovery characteristics of the nozzle of gas circuit breaker was described. In order to obtain thermal recovery characteristics, the transient simulation of SF6 arc plasma within the nozzle was carried out. In particular, the nozzle ablation was taken into account by simultaneously solving the PTFE concentration equation with the governing equations such as continuity, momentum and energy equation. After that, post arc current calculation was performed with the rate of rise of recovery voltage changed. From the calculated post arc current, it was possible to suggest the thermal recovery characteristics of the nozzle of gas circuit breaker.

고온ㆍ고압 아크 플라즈마 하에서의 정상상태 노즐용삭 해석 기술 (Steady State Analysis of Nozzle Ablation Under High Temperature and High Pressure Arc Plasma)

  • 이병윤;송기동;정진교;박경엽
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권9호
    • /
    • pp.395-399
    • /
    • 2003
  • In this paper, physical phenomena which are related to the high temperature and high pressure arc plasma generated during the fault current interruption by SF6 gas circuit breakers are reviewed. In particular, in order to analyze nozzle ablation induced by the heats transferred to the surface of the poly-tetrafluoroethylene(PTFE) nozzle through arc radiation, a governing equation for the calculation of PTFE concentration is added to the governing equations for SF6 arc Plasma analysis. The proposed method is applied to the steady state analysis of $SF_6$ arc plasma generated by direct current taking account of the nozzle ablation and the results are presented.

역기전력 전류를 고려한 자속 역전식 기기의 특성 해석 (Characteristics Analysis of Flux-Reversal Machine considering BEMF Current)

  • 김태형;이주
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권12호
    • /
    • pp.709-717
    • /
    • 2004
  • Flux-reversal machine (FRM) is a new brushless doubly salient permanent magnet machine. Its operation is similar to that of the brushless DC motor, so it can be driven by 120 degree square wave voltage and use PWM pulse patterns in two-phase feeding scheme to control the speed. In this driving method, the back electromotive force (BEMF) current in the open phase is generated by the BEMF. It can be appeared or disappeared according to the changes of the neutral voltage of the machine. In this paper, the time-stepped voltage source finite-element method taking BEMF current into account is proposed. Its influences on the performances of the FRM are also investigated. To prove the propriety of the proposed analysis method, a Digital Signal Processor (DSP) installed experimental devices are equipped and the experiment is performed.

Numerical analysis of viscoelastic flows in a channel obstructed by an asymmetric array of obstacles

  • Kwon, Young-Don
    • Korea-Australia Rheology Journal
    • /
    • 제18권3호
    • /
    • pp.161-167
    • /
    • 2006
  • This study presents results on the numerical simulation of Newtonian and non-Newtonian flow in a channel obstructed by an asymmetric array of obstacles for clarifying the descriptive ability of current non-Newtonian constitutive equations. Jones and Walters (1989) have performed the corresponding experiment that clearly demonstrates the characteristic difference among the flow patterns of the various liquids. In order to appropriately account for flow properties, the Navier-Stokes, the Carreau viscous and the Leonov equations are employed for Newtonian, shear thinning and extension hardening liquids, respectively. Making use of the tensor-logarithmic formulation of the Leonov model in the computational scheme, we have obtained stable solutions up to relatively high Deborah numbers. The peculiar characteristics of the non-Newtonian liquids such as shear thinning and extension hardening seem to be properly illustrated by the flow modeling. In our opinion, the results show the possibility of current constitutive modeling to appropriately describe non-Newtonian flow phenomena at least qualitatively, even though the model parameters specified for the current computation do not precisely represent material characteristics.