• Title/Summary/Keyword: current account

Search Result 1,189, Processing Time 0.025 seconds

Numerical simulation for increment of neutron production rate in SCBF device (SCBF 장치에서 중성자 생성률 증대를 위한 수치해석)

  • Ju, Heung-Jin;Park, Jeong-Ho;Ko, Kwang-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2184-2186
    • /
    • 2005
  • Neutron production is very important to apply fusion energy through SCBF(Spherically Convergent Beam Fusion) device and its rate is Proportional to the square of the ion current$({\propto}I^2)$. Also the ion current has a close relation with the potential well structure in grid cathode. In this paper, the ion current is calculated for the increasement of neutron production rate in a variety of grid cathode geometry. The atomic and molecular collision are taken into account by Monte Carlo Method and Potential is calculated by Finite Element Method. Main processes of the discharge is the ionization of $D_2$ by fast $D_2^+$ ion. As the number of a cathode ring is small and gap distance decreases, the ion current increases and neutron production rate will increase.

  • PDF

Extension of Cut-off Capacity of DC Circuit Breaker due to Superconducting Coil Application (초전도 코일 적용으로 인한 DC 차단기의 차단 용량 증대)

  • Choi, Hye-Won;Choi, Hyo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.4
    • /
    • pp.593-597
    • /
    • 2019
  • We proposed a current Interruption type DC superconducting circuit breaker(I-DC SCB), a protection device that combines the current limiting technology of a superconductor with the cut-off technology of circuit breaker. Unlike existing protective devices, the current I-DC SCB is a device that combines two protection functions, notably improving failure probability and operational reliability. It is also applicable to all DC systems, such as HV, MV, and LVDC, due to the ease in capacity increase. The 100 kV I-DC SCB was designed after taking into account the actual power system conditions, followed by an analysis of the transient characteristics and the breaking range of the limiter. The results of the analysis showed that the I-DC SCB had a fault current limit of about 75% at the rated voltage, and completed the cut-off operation within about 20 ms.

A Modified Capacitor Current Feedback Active Damping Approach for Grid Connected Converters with an LCL Filter

  • Wan, Zhiqiang;Xiong, Jian;Lei, Ji;Chen, Chen;Zhang, Kai
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1286-1294
    • /
    • 2015
  • Capacitor current feedback active damping is extensively used in grid-connected converters with an LCL filter. However, systems tends to become unstable when the digital control delay is taken into account, especially in low switching frequencies. This paper discusses this issue by deriving a discrete model with a digital control delay and by presenting the stable region of an active damping loop from high to low switching frequencies. In order to overcome the disadvantage of capacitor current feedback active damping, this paper proposes a modified approach using grid current and converter current for feedback. This can expand the stable region and provide sufficient active damping whether in high or low switching frequencies. By applying the modified approach, the active damping loop can be simplified from fourth-order into second-order, and the design of the grid current loop can be simplified. The modified approach can work well when the grid impedance varies. Both the active damping performance and the dynamic performance of the current loop are verified by simulations and experimental results.

Effect of the Neighboring Tape′s AC Currents on Transport Current Loss of a Bi-2223 Tape (인접 교류전류가 Bi-2223테이프의 통전손실에 미치는 영향)

  • 류경우;최병주
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.3
    • /
    • pp.251-256
    • /
    • 2001
  • Bi-2223 tapes have been developed for low-field power applications at liquid nitrogen temperature. When the Bi-2223 tapes are used in an application such as a power transmission cable or a power transformer, they are supplied with an AC transport current simultaneously. AC loss taking into account such real applications is a crucial issue for power applications fo the Bi-2223 tapes to be feasible. In this paper, the transport losses for different AC current levels and arrangements of the neighboring tapes have been measured in a 1./5 m long Bi-2223 tape. The significant increase of the transport losses due to neighboring tape's AC currents is observed. An increase of the transport losses caused by a decrease of the Bi-2223 tape's critical current is a minor effect. The measured trasprot losses could not be explained by a dynamic resistance loss based on DC voltage-current characteristics in combination with the neighboring tape's AC currents.The trasport losses do not depend on the frequency of the neighboring tape's AC currents but is arrangements in the range of small current especially.

  • PDF

A Study of Optimizing Cathodic Protection in Comparison of Design Methodologies

  • Choi, Young-Kwan;Choi, Sang-Yule;Shin, Myong-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.11
    • /
    • pp.23-29
    • /
    • 2010
  • The principal factor determining an optimum design method for cathodic protection is finding the protection current for preventing the corrosion of existing, already laid pipe. Some factors currently used to test designs include the sizes and lengths of pipes, soil resistivity, and the coating damage rate. We believe this method and current formulae are not optimum due to the uncertainty of determining the coating damage rate and the corrosion protection current's density. This paper analyzes the amount of protection current obtained by performing a temporary current test using data describing existing laid pipe. We then propose determining the corrosion protection current by using the temporary current test after modifying the formula. In addition, we suggest a way to choose optimized cathodic protection and the process of design by executing the design and taking account of such factors as a site condition of 34km-long non-protected water supply pipe lines (stages I and II) in ${\bigcirc}{\bigcirc}$ region, climate, interferences, and durability.

A Study on Transverse Edge Effect in Linear Induction Motor With Sheet Rotor (Sheet Rotor를 가진 직선형 유도전동기의 Transverse Edge Effect에 관한 연구)

  • Yun Jong Lee;Dal Ho Im;Soo Hyun Baek
    • 전기의세계
    • /
    • v.23 no.4
    • /
    • pp.39-45
    • /
    • 1974
  • In most previous research work, the transverse edge effect has been allowed for only by use of a relativity-increase factor. This paper gives a more exact treatment. A two-dimensional-field analysis is presented for the problem of sheet rotor linear induction motor with finite width the method used takes account of flux leakage in the space between the stator and secondary sheet rotor as well as in the secondary itself. Equations are derived for the flux density distribution in the air gap and for the starting face, in each case as a function of stator current. The cross gap flux density peaks towards athe edge of the stator. This phenomena is known as the transverse edge effect. Measurements of the flux density in the air gap and starting force on a linear induction motor with sheet rotor of different width showed a reasonable agreement,suggest that it would be desirable to take into account also, at least for this motor in which severe redistribution occurs.

  • PDF

A Development on Method of Strengthening Design for the Different Status of Damages (손상상태를 고려한 부재의 보강설계법 개발)

  • 한만엽;이성준
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.1
    • /
    • pp.69-77
    • /
    • 2000
  • Recently, many strengthening methods are developed to repair damaged structures, when the original structure is under loading, which causes the difference of initial stresses between original member and bonded material. However, current design method or theory, which mostly depends on ultimately strength design, cannot account the difference of initial stresses between members, and it disregards the reduction of nominal strength. In this study, a new strengthening design theory and the amount of strengthening which can account the difference of initial stresses are developed, and applied to the case when a structure in service is repaired. The results show that the amount of strengthening material depends on the status of damages of structure, and the nominal strength is reduced depending on the degree of damages.

Flow-Aware Link Dimensioning for Guaranteed-QoS Services in Broadband Convergence Networks

  • Lee, Hoon;Sohraby, Khosrow
    • Journal of Communications and Networks
    • /
    • v.8 no.4
    • /
    • pp.410-421
    • /
    • 2006
  • In this work, we propose an analytic framework for dimensioning the link capacity of broadband access networks which provide universal broadband access services to a diverse kind of customers such as patient and impatient customers. The proposed framework takes into account the flow-level quality of service (QoS) of a connection as well as the packet-level QoS, via which a simple and systematic provisioning and operation of the network are provided. To that purpose, we first discuss the necessity of flow-aware network dimensioning by reviewing the networking technologies of the current and future access network. Next, we propose an analytic model for dimensioning the link capacity for an access node of broadband convergence networks which takes into account both the flow and packet level QoS requirements. By carrying out extensive numerical experiment for the proposed model assuming typical parameters that represent real network environment, the validity of the proposed method is assessed.

From Opposition to Cooperation: Semantic Change of with

  • Rhee, Seongha
    • Korean Journal of English Language and Linguistics
    • /
    • v.4 no.2
    • /
    • pp.151-174
    • /
    • 2004
  • A historical investigation reveals that English preposition with underwent a change from OPPOSITION to ASSOCIATION and further to ACCOMPANIMENT, where the first stage shows peculiarity in that the two concepts involved comprise an unusual set to form an extensional chain. Intrigued by this oddity, this paper aims to investigate the semantic structure of English preposition with from a grammaticalization perspective. We review mechanisms and models of semantic change and evaluate their adequacy with the semantic structure and change shown by with. Drawing upon the observed fact that with underwent the apparent antonymic semantic change, it is argued that such semantic change mechanisms as metaphor, metonymy, subjectification, and generalization have difficulties explaining the change, and that only the Frame-of-Focus Variation can effectively account for this peculiar change type. In terms of semantic change models, we argue that the Bleaching Model cannot effectively provide an explanation; that the Loss and Gain Model has problems in explaining the motivation of change directions; that the Metonymic-Metaphoric Model cannot be assessed at the current level of investigation; and that the Overlap Model and the Prototype Extension Model excellently account for the macro-level changes.

  • PDF

A Study for Numerical Procedure of Strengthening Capacity in Field Structure (사용중 보강되는 부재의 보강설계법 연구)

  • 한만엽;이원창
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.3
    • /
    • pp.13-21
    • /
    • 1999
  • Recently, many strengthening methods are developed to repair damaged structures, especially, steel plate or carbon fiber sheet bonding methods are widely used. For the bonding methods, the strengthening materials are bonded when the original structure is under loading, with causes the difference of initial stresses between original member and bonded material. However, current design method or theory, which mostly depends on ultimately strength design, cannot account the difference of initial stresses between members, and it disregards the reduction of nominal strength. In this study, a new strengthening design theory and program which can account the difference of initial stresses are developed, and applied to the case when a structure in service is repaired. In order to verify the validity of the theory and the program, a test result is referred and compare with the results and it is showed that the calculated values are almost same as the referred data and finally proved that the program is reliable. The results showed that the amount of strengthening material depends on the status of damages of structure, and the nominal strength is reduced depending on the degree of damages.