• Title/Summary/Keyword: cross resistance

Search Result 1,269, Processing Time 0.032 seconds

Fracture Characteristics of the Resistance Spot Welded Joints by Acoustic Emission (음향방출법에 의한 저항 점용접부의 파괴특성에 대한 연구)

  • Jo, Dae-Hee;Rhee, Zhang-Kyu;Park, Sung-Oan;Kim, Bong-Gag;Woo, Chang-Ki
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.2
    • /
    • pp.14-22
    • /
    • 2007
  • In this paper, the acoustic emission(AE) behaviors were investigated with single-and 2-spot resistance spot welded SPCC specimens. Test specimens were welded horizontally and/or vertically according to the rolling direction of base netal in 2-spot welding. In the case of 2-spot welding, when tensile-shear test has below amplitudes: crack initiation $50{\sim}60dB;$ tear fracture $40{\sim}50dB$. And when cross tensile test has below amplitudes: early stage $75{\sim}85dB;$ yielding point $65{\sim}75dB;$ post yielding $40{\sim}60dB;$ plug fracture $70{\sim}80dB\;or\;90{\sim}100dB$. Also, from the b-value that is slope of AE amplitude, we knew that there are lots of low amplitudes if b-value is big(i.e., tensile-shear $specimen{\rightarrow}tear$ fracture or shear fracture), and there are lots of high amplitudes if b-value is small(i.e.. cross tensile $specimen{\rightarrow}plug$ fracture). As the results of fiacture mechanism analyses through AE amplitude distributions, change of the b-value represented fracture patterns of materials. Correspondingly, low amplitude signals appeared in crack initiation, and high amplitude signals appeared in base metal fracture. We confirmed that these amplitude distributions represented the change or degradation of materials.

Application of Miniature Heat Pipe for Notebook PC Cooling (노트북 PC CPU 냉각용 소형 히트파이프 Packaging 연구)

  • Moon, Seok-Hwan;Hwang, Gunn;Choy, Tae-Goo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.6
    • /
    • pp.799-803
    • /
    • 2001
  • Miniature heat pipe(MHP) with woven-wired wick was used to cool the CPU of a notebook PC. The pipe with circular cross-section was pressed and bent for packaging the MHP into a notebook PC with very limited compact packaging space. A cross-sectional area of the pipe is reduced about 30% as the MHP with 4mm diameter is pressed to 2mm thickness. In the present study a performance test has been performed in order to review varying of operating performance according to pressed thickness variation and heat dissipation capacity of MHP cooling module that is packaged on a notebook PC. New wick type was considered for overcoming low heat transfer limit when MHP is pressed to thin-plate. The limiting thickness or pressing is shown to be within the range of 2mm∼2.5mm through the performance test with varying the pressing thickness. When the wall thickness of 0.4mm is reduced to 0.25mm for minimizing conductive thermal resistance through the wall of heat pipe, heat transfer limit and thermal resistance of MHP were improved about 10%. In the meantime, it is shown that the thermal resistance and heat transfer limit for the MHP with central wick type are higher than those of MHP with existing wick types. The results of performance test for MHP cooling modules with woven-wired wick to cool a notebook PC shows the stability as cooling system since T(sub)j(Temperature of Processor Junction) satisfy a demand condition of 0∼100$\^{C}$ under 11.5W of CPU heat.

Investigation of surface pressures on CAARC tall building concerning effects of turbulence

  • Li, Yonggui;Yan, Jiahui;Chen, Xinzhong;Li, Qiusheng;Li, Yi
    • Wind and Structures
    • /
    • v.31 no.4
    • /
    • pp.287-298
    • /
    • 2020
  • This paper presents an experimental investigation on the surface pressures on the CAARC standard tall building model concerning the effects of freestream turbulence. Two groups of incidence turbulence are generated in the wind tunnel experiment. The first group has an approximately constant turbulence intensity of 10.3% but different turbulence integral scale varying from 0.141 m to 0.599 m or from 0.93 to 5.88 in terms of scale ratio (turbulence integral scale to building dimension). The second group presents similar turbulence integral scale but different turbulence intensity ranging from 7.2% to 13.5%. The experimental results show that the mean pressure coefficients on about half of the axial length of the side faces near the leading edge slightly decrease as the turbulence integral scale ratio that is larger than 4.25 increases, but respond markedly to the changes in turbulence intensity. The root-mean-square (RMS) and peak pressure coefficients depend on both turbulence integral scale and intensity. The RMS pressure coefficients increase with turbulence integral scale and intensity. As the turbulence integral scale increases from 0.141 m to 0.599 m, the mean peak pressure coefficient increases by 7%, 20% and 32% at most on the windward, side faces and leeward of the building model, respectively. As the turbulence intensity increases from 7.2% to 13.5%, the mean value of peak pressure coefficient increases by 47%, 69% and 23% at most on windward, side faces and leeward, respectively. The values of cross-correlations of fluctuating pressures increase as the turbulence integral scale increases, but decrease as turbulence intensity increases in most cases.

Relationship Between Lodging-Related Characteristics and Field Lodging in Rice (벼 도복 관련형질과 포장도복과의 관계)

  • 임준택;권병선;정병관
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.36 no.4
    • /
    • pp.319-323
    • /
    • 1991
  • To determine how closely related to field lodging for several characters affecting the field lodging for several characters affecting field lodging, and to obtain the basic information for selection of lodging resistance genotype, an experiment was conducted with 10 varieties from May to Oct., 1990 at the experimental field in Sunchon Xational University. Culm length, dry weight per unit culm length (W/1), bending moment per unit culm diameter (W1/d), lodging index (L), bending load ratio (W1/P), and index of critical lodging load(W$_{s}$$^{2}$/1$^4$) were the most closely related characters to field lodging. Culm length showed highly significant positive correlation coefficient with field lodging(r=0.7607), but it may be undesirable to judge lodging resistance of genotype by culm length itself without consideration of culm stiffness. Considering the difficulty and time-consuming to measure the character, clum length, W/1, W1/d, and W$_{s}$$^{2}$/1$^4$ were easy to measure and hence would be the most useful variables to judge the lodging resistance of genotype. Culm diameter, cross sectional area of culm, thickness of culm wall, and the second inertia moment of cross section of culm were not correlated with field lodging at all. Breaking strength of culm showed significantly negative correlation coefficient (r=-0.3986) with field lodging.ing.

  • PDF

The Implementation of Load Resistance Measurement System using Time-Frequency Domain Reflectometry (시간-주파수 영역 반사파 계측방법을 이용한 부하 저항 측정 시스템 구현)

  • Kwak, Ki-Seok;Park, Tae-Geun;Yoon, Tae-Sung;Park, Jin-Bae
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.10
    • /
    • pp.435-442
    • /
    • 2006
  • One of the most important topics about the safety of electrical and electronic system is the reliability of the wiring system. The Time-Frequency Domain Reflectometry(TFDR) is a state-of-the-art system for detecting and estimating of the fault on a wiring. In this paper, We've considered the load resistance measurement on a coaxial cable using TFDR in a way of expanded application. The TFDR system was built using commercial Pci extensions for Instrumentation(PXI) and LabVIEW. The proposed real time TFDR system consisted of the reference signal design, signal generation, signal acquisition, algorithm execution and results display part. To implement real time system, all of the parts were programmed by the LabVIEW which is one of the graphical programming languages. Using the application software implemented by the LabVIEW, we were able to design a proper reference signal which is suitable for target cable and control not only the arbitrary waveform generator in the signal generation part but alto the digital storage oscilloscope in the signal acquisition part. By using the TFDR real time system with the terminal resistor on the target cable, we carried out load impedance measurement experiments. The experimental results showed that the proposed system are able not only to detect the location of impedance discontinuity on the cable but also to estimate the load resistance with high accuracy.

Metabolic Syndrome and Insulin Resistance Syndrome among Infertile Women with Polycystic Ovary Syndrome: A Cross-Sectional Study from Central Vietnam

  • Le, Minh Tam;Nguyen, Vu Quoc Huy;Truong, Quang Vinh;Le, Dinh Duong;Le, Viet Nguyen Sa;Cao, Ngoc Thanh
    • Endocrinology and Metabolism
    • /
    • v.33 no.4
    • /
    • pp.447-458
    • /
    • 2018
  • Background: Polycystic ovarian syndrome (PCOS) is one of the most common endocrinopathies among reproductive-age women. Its metabolic features often overlap with those associated with metabolic syndrome (MS) and insulin resistance syndrome (IRS). The objective of this study was to determine the prevalence and predictors of MS and IRS in infertile Vietnamese women with PCOS. Methods: A cross-sectional study was conducted at a tertiary fertility centre at Hue University Hospital from June 2016 to November 2017. A total of 441 infertile women diagnosed with PCOS based on the revised 2003 Rotterdam consensus criteria were enrolled. MS and IRS were defined based on the National Heart, Lung, and Blood Institute/American Heart Association Adult Treatment Panel III 2005 and American College of Endocrinology IRS 2003 criteria, respectively. Complete clinical and biochemical measurements of 318 women were available for analysis. Independent predictors of MS and IRS were identified using multivariate logistic regression. Results: The overall prevalence of MS and IRS in women with PCOS was 10.4% and 27.0%, respectively. We identified older age (>30 years) and obesity as independent predictors of MS and IRS. Elevated anti-$M{\ddot{u}}llerian$ hormone levels increased the risk of IRS, but not that of MS. Conclusion: MS and IRS are prevalent disorders among infertile Vietnamese women with PCOS. PCOS is not solely a reproductive problem. Screening and early intervention for MS and/or IRS based on anthropometric, metabolic, and reproductive hormone risk factors should be an integral part of fertility care.

Finite Element Analysis of Slender Reinforced Concrete Columns Subjected to Eccentric Axial Loads and Elevated Temperature (고온과 편심 축하중을 받는 세장한 철근 콘크리트 기둥의 유한요소해석)

  • Lee, Jung-Hwan;Kim, Han-Soo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.35 no.3
    • /
    • pp.159-166
    • /
    • 2022
  • In this study, slender reinforced concrete columns subjected to high temperatures and eccentric axial loads are evaluated by finite element analysis employing Abaqus (a finite element analysis program). Subsequently, the analysis results are compared and assessed. The sequentially coupled thermal stress analysis provided by Abaqus was employed to reflect the condition of an axially loaded column exposed to fire. First, heat transfer analysis was performed on the column cross-section. After verifying the results, another analysis was conducted: the cross-section was transformed into a three-dimensional element and then structural analyzed. In the analysis process, the column was modeled by accounting for the effects of tension stiffening and initial imperfection that could affect convergence and accuracy. The analysis results were compared with 74 experimental records, and an average error of 6% was observed based on the fire exposure and resistance. The foregoing indicates that the fire resistance performance of reinforced concrete columns can be predicted through finite element analysis.

Prevalence and characterization of pathogenic Escherichia coli from carcasses and environmental samples of cattle and pig slaughterhouses (소와 돼지 도축장 도체 및 환경에서 분리된 병원성대장균 분포 및 특성조사)

  • Hong, Serim;Kang, Hye Jeong;Moon, Jin-San;Yoon, Soon-Seek;Kim, Ha-Young
    • Korean Journal of Veterinary Service
    • /
    • v.45 no.3
    • /
    • pp.191-199
    • /
    • 2022
  • We investigated the virulence genes, O-serotypes, antimicrobial resistance of pathogenic E. coli isolated from carcasses (n=455) and environmental (n=372) samples of 11 cattle and 12 pig slaughterhouses from December 2020 to December 2021. E. coli were isolated from nine carcasses (2.0%), three slaughter facilities (1.4%), two utensils (2.7%) and three abattoir workers (3.5%) from four cattle and four pig slaughterhouses. Among all isolates, 13 STEC (76.5%) were identified, followed by four EPEC (23.5%). As a result of the antibiotic susceptibility test, all isolates were resistant to at least one antimicrobial, of which 70.6% isolates showed multidrug resistance patterns. The serotypes were diverse in pigs compared to cattle, with serotypes O18, O66, O109 in cattle and O9, O76, O85, O100, O153, and O159 in pigs. In a single cattle slaughterhouse, eight STEC O66 were isolated from various types of sample (4 slaughter animal surfaces, 3 gloves, and 1 knife) with two antimicrobial resistance patterns (CHL-FIS-STR and CHL-FIS). Those two types of strain were suspected cross-contamination from utensils to slaughter animal surfaces. These results showed that pathogenic E. coli were detected in carcasses and various environmental samples in cattle and pig slaughterhouses. Nationwide monitoring and hygiene management are required to prevent cross-contamination of STEC isolate slaughterhouses.

A Study On the Sand Wear Resistance and Formation Behavior of Boride Layer Formed on Ni-Cr-Mo Steel by Plasma Paste Boronizing Treatment (Plasma Paste Boronizing법에 의한 Ni-Cr-Mo강의 붕화물층 생성거동과 내 토사마모특성에 관한 특성)

  • Cho J. H;Park H. K;Son K. S;Yoon J. H;Kim H. S;Kim C. G
    • Korean Journal of Materials Research
    • /
    • v.14 no.1
    • /
    • pp.52-58
    • /
    • 2004
  • The surface property and formation behavior of a boride layer formed on Ni-Cr-Mo steel in a plasma paste boronizing treatment were investigated. The plasma paste boronizing treatment was carried out at 973~1273 K for 1-7 hrs under the gas ratio of Ar:H$_2$ (2:1). The thickness of the boride layer increased with increasing temperature and time in the boronizing treatment. The cross-section of the boride layer was a tooth structure and the hardness was Hv 2000~2500. XRD analysis revealed that the compound was identified as FeB, $Fe_2$B, and mixed phase of FeB/$Fe_2$B in the boride layer formed at 973~1073 K, 1173K, and 1273K, respectively. The Ni-Cr-Mo alloy boronized at 1173-1273 K showed the best excellent wear resistance against the sand. As a results of corrosion test in 1 M $H_2$$SO_4$ solution, $Fe_2$B formed on the matrix alloy exhibited higher corrosion resistance than FeB.

Control of Gas Direction in Gas Assisted Injection Molding (가스사출시 가스흐름방향의 예측 및 제어)

  • Soh, Young-Soo
    • The Korean Journal of Rheology
    • /
    • v.11 no.2
    • /
    • pp.153-158
    • /
    • 1999
  • An improved method to predict preferred direction of gas in gas assisted injection molding processes is introduced. Resistance of resin flow is defined and this resistance of resin flow is not directly related to the resistance of gas flow. Pressure drop requirement was believed to be proportional to the resistance to gas flow in our previous work. Instead of using the pressure drop requirement, velocity of resin should be compared to predict the gas flow direction. This method predicts the gas flow direction from the knowledge of process variables such as resin flow length, cross section area of cavity, melt temperature, and short shot. A simulation package was used to confirm the method.

  • PDF