• 제목/요약/키워드: coupled structures control

검색결과 110건 처리시간 0.101초

Time delay study for semi-active control of coupled adjacent structures using MR damper

  • Katebi, Javad;Zadeh, Samira Mohammady
    • Structural Engineering and Mechanics
    • /
    • 제58권6호
    • /
    • pp.1127-1143
    • /
    • 2016
  • The pounding phenomenon in adjacent structures happens in severing earthquakes that can cause great damages. Connecting neighboring structures with active and semi-active control devices is an effective method to avoid mutual colliding between neighboring buildings. One of the most important issues in control systems is applying online control force. There will be a time delay if the prose of producing control force does not perform on time. This paper proposed a time-delay compensation method in coupled structures control, with semi-active Magnetorheological (MR) damper. This method based on Newmark's integration is adopted to mitigate the time-delay effect. In this study, Lyapunov's direct approach is employed to compute demanded voltage for MR dampers. Using Lyapunov's direct algorithm guarantees the system stability to design a controller based on feedback. Because of the strong nonlinearity of MR dampers, the equation of motion of coupled structures becomes an involved equation, and it is impossible to solve it with the common time step methods. In present paper modified Newmark-Beta integration based on the instantaneous optimal control algorithm, used to solve the involved equation. In this method, the response of a coupled system estimated base on optimal control force. Two MDOF structures with different degrees of freedom are finally considered as a numeric example. The numerical results show, the Newmark compensation is an efficient method to decrease the negative effect of time delay in coupled systems; furthermore, instantaneous optimal control algorithm can estimate the response of structures suitable.

Stochastic optimal control of coupled structures

  • Ying, Z.G.;Ni, Y.Q.;Ko, J.M.
    • Structural Engineering and Mechanics
    • /
    • 제15권6호
    • /
    • pp.669-683
    • /
    • 2003
  • The stochastic optimal nonlinear control of coupled adjacent building structures is studied based on the stochastic dynamical programming principle and the stochastic averaging method. The coupled structures with control devices under random seismic excitation are first condensed to form a reduced-order structural model for the control analysis. The stochastic averaging method is applied to the reduced model to yield stochastic differential equations for structural modal energies as controlled diffusion processes. Then a dynamical programming equation for the energy processes is established based on the stochastic dynamical programming principle, and solved to determine the optimal nonlinear control law. The seismic response mitigation of the coupled structures is achieved through the structural energy control and the dimension of the optimal control problem is reduced. The seismic excitation spectrum is taken into account according to the stochastic dynamical programming principle. Finally, the nonlinear controlled structural response is predicted by using the stochastic averaging method and compared with the uncontrolled structural response to evaluate the control efficacy. Numerical results are given to demonstrate the response mitigation capabilities of the proposed stochastic optimal control method for coupled adjacent building structures.

Comparison of an ultrasonic distance sensing system and a wire draw distance encoder in motion monitoring of coupled structures

  • Kuanga, K.S.C.;Hou, Xiaoyan
    • Coupled systems mechanics
    • /
    • 제5권2호
    • /
    • pp.191-201
    • /
    • 2016
  • Coupled structures are widely seen in civil and mechanical engineering. In coupled structures, monitoring the translational motion of its key components is of great importance. For instance, some coupled arms are equipped with a hydraulic piston to provide the stiffness along the piston axial direction. The piston moves back and forth and a distance sensing system is necessary to make sure that the piston is within its stroke limit. The measured motion data also give us insight into how the coupled structure works and provides information for the design optimization. This paper develops two distance sensing systems for coupled structures. The first system measures distance with ultrasonic sensor. It consists of an ultrasonic sensing module, an Arduino interface board and a control computer. The system is then further upgraded to a three-sensor version, which can measure three different sets of distance data at the same time. The three modules are synchronized by the Arduino interface board as well as the self-developed software. Each ultrasonic sensor transmits high frequency ultrasonic waves from its transmitting unit and evaluates the echo received back by the receiving unit. From the measured time interval between sending the signal and receiving the echo, the distance to an object is determined. The second distance sensing system consists of a wire draw encoder, a data collection board and the control computer. Wire draw encoder is an electromechanical device to monitor linear motion by converting a central shaft rotation into electronic pulses of the encoder. Encoder can measure displacement, velocity and acceleration simultaneously and send the measured data to the control computer via the data acquisition board. From experimental results, it is concluded that both the ultrasonic and the wire draw encoder systems can obtain the linear motion of structures in real-time.

전단벽 구조물의 풍응답 저감을 위한 LRB의 적용 (Application of LRBs for Reduction of Wind-Induced Responses of Coupled Shear Wall Structures)

  • 박용구;김현수;고현;김민균;이동근
    • 한국공간구조학회논문집
    • /
    • 제11권1호
    • /
    • pp.47-56
    • /
    • 2011
  • 일반적으로 전단벽은 횡력저항 요소로서 널리 이용되고 있다. 대부분의 전단벽 구조물은 통로의 목적으로 개구부를 필요로 하게 되고 전단벽들 사이가 슬래브나 연결보로 연결된 병렬전단벽의 형태를 띠게 된다. 본 연구에서는 병렬전단벽 구조물의 연결보 중앙부에 LRB(Lead Rubber Bearing)를 도입하였고 이 시스템의 풍응답 저감성능을 검토하였다. 제안된 방법의 효과를 살펴보기 위하여 20층 및 30층 예제구조물을 구성하였고 인공풍하중을 작성하여 경계비선형 시간이력해석을 수행하였다. 제안된 방법이 풍하중을 받는 고층 병렬전단벽 구조물의 사용성 향상에 도움을 줄 수 있는지 평가하기 위하여 일본 진동성능평가기준을 적용하여 보았다. 해석결과 본 논문에서 제안하는 LRB를 사용하여 병렬전단벽을 연결하는 방식이 풍응답 제어성능 개선에 효과가 있는 것을 확인할 수 있었다.

Optimum tuned mass damper approaches for adjacent structures

  • Nigdeli, Sinan Melih;Bekdas, Gebrail
    • Earthquakes and Structures
    • /
    • 제7권6호
    • /
    • pp.1071-1091
    • /
    • 2014
  • Pounding of adjacent structures are always a notable reason for damages after strong ground motions, but it is already unforeseen detail in newly constructed structures. Thus, several approaches have been proposed in order to prevent the pounding of structures. By using optimally tuned mass dampers, it is possible to decrease the displacement vibrations of structures. But in adjacent structures, the response of both structures must be considered in the objective function of optimization process. In this paper, two different designs of Tuned Mass Dampers (TMD) are investigated. The first design covers independent TMDs on both structures. In the second design, adjacent structures are coupled by a TMD on the top of the structures. Optimum TMD parameters are found by using the developed optimization methodology employing harmony search algorithm. The proposed method is presented with single degree of freedom and multiple degree of freedom structures. Results show that the coupled design is not effective on multiple degree of freedom adjacent structures. The coupled design is only effective for rigid structures with a single degree of freedom while the use of independent TMDs are effective on both rigid and flexural structures.

LRB를 이용한 병렬전단벽 구조물의 지진응답제어 (Seismic Responses Control of Coupled Shear Wall Structures Using LRBs)

  • 박용구;김현수;고현;김민균;이동근
    • 한국지진공학회논문집
    • /
    • 제14권6호
    • /
    • pp.1-9
    • /
    • 2010
  • 대부분의 전단벽 구조물은 통로의 목적으로 개구부를 필요로 하게 되고 전단벽들 사이가 슬래브나 연결보로 연결된 병렬 전단벽의 형태를 띠게 된다. 이러한 구조물에 지진하중이 작용할 때 연결보에 과도한 전단력이 작용하여 연결보가 취성적으로 파괴되거나 전단벽이 먼저 항복하는 문제점이 발생할 수 있다. 이를 방지하기 위하여 연결보에 감쇠장치를 설치하게 되면 구조물의 진동제어효과와 더불어 연결보의 응력집중 및 취성적 파괴를 막을 수 있어서 내진성능 향상을 기대할 수 있다. 본 논문에서는 병렬전단벽 연결보 중앙부에 LRB (Lead Rubber Bearing)가 설치된 구조물의 지진응답제어효과 및 응력의 분포를 평가하여 구조적 효율성을 확인하고자 한다. 이를 위하여 병렬전단벽의 거동을 비교적 정확하게 모사할 수 있는 모형화 방법을 제안하였고, 제안된 모형화 방법을 통하여 지진하중을 받는 예제 병렬구조물에 대한 시간이력해석을 수행한 후 지진응답제어성능을 검토하였다.

Tuned mass dampers for torsionally coupled systems

  • Pansare, A.P.;Jangid, R.S.
    • Wind and Structures
    • /
    • 제6권1호
    • /
    • pp.23-40
    • /
    • 2003
  • The steady state response of a torsionally coupled system with tuned mass dampers (TMDs) to external wind-induced harmonic excitation is presented. The torsionally coupled system is considered as one-way eccentric system. The eccentricity considered in the system is accidental eccentricity only. The performance of single tuned mass damper (TMD) optimally designed without considering the torsion is investigated for the torsionally coupled system and found that the effectiveness of a single TMD is significantly reduced due to torsion in the system. However, the design of TMD system without considering the torsion is only justified for torsionally stiff systems. Further, the optimum parameters of a single TMD considering the accidental eccentricity are obtained using numerical searching technique for different values of uncoupled torsional to lateral frequency ratio and aspect ratio of the system. The optimally designed single TMD system is found to be less effective for torsionally coupled system in comparison to uncoupled system. This is due to the fact that a torsionally coupled system has two natural frequencies of vibration, as a result, at least two TMDs are required which can control both lateral and torsional response of the system. The optimum damper parameters of different alternate arrangements such as (i) two identical TMDs placed at opposite corners, (ii) two independent TMDs and (iii) four TMDs are evaluated for minimum response of the system. The comparative performance of the above TMDs arrangements is also studied for both torsionally coupled and uncoupled systems. It is found that four TMDs arrangement is quite effective solution for vibration control of torsionally coupled system.

GA-SMC를 이용한 이중 탱크의 정밀한 수위 제어 (Control of Coupled Tank Level using GA-SMC)

  • 박현철;지석준;정종원;최우진;이준탁
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2002년도 춘계학술대회논문집
    • /
    • pp.239-244
    • /
    • 2002
  • Even though, tanks are used at the many industry plants, it is very difficult to control the tank level without any overflow and shortage; moreover, cause of its complication of dynamics and nonlinearity, it's impossible to realize the accurate control using the mathematical model which can be applied to the various operation modes. However, the sliding mode controller(SMC) is known as having the robust variable structures for the nonlinear control systems with the parametric perturbations and with the sudden disturbances, but the auto-tuning of parameters was a problem. Therefore, in this paper, a Genetic Algorithm based Sliding Mode Controller (GA-SMC) for the precise control of the coupled tank level was tried. GA optimized the SMCs switching parameters easily and rapidly. The simulation results are shown that the tank level could be satisfactorily controlled with less overshoot and steady-stale error by the proposed GA-SMC.

  • PDF

Distribution of Optimum Yield-Strength and Plastic Strain Energy Prediction of Hysteretic Dampers in Coupled Shear Wall Buildings

  • Bagheri, Bahador;Oh, Sang-Hoon;Shin, Seung-Hoon
    • 국제강구조저널
    • /
    • 제18권4호
    • /
    • pp.1107-1124
    • /
    • 2018
  • The structural behavior of reinforced concrete coupled shear wall structures is greatly influenced by the behavior of their coupling beams. This paper presents a process of the seismic analysis of reinforced concrete coupled shear wall-frame system linked by hysteretic dampers at each floor. The hysteretic dampers are located at the middle portion of the linked beams which most of the inelastic damage would be concentrated. This study concerned particularly with wall-frame structures that do not twist. The proposed method, which is based on the energy equilibrium method, offers an important design method by the result of increasing energy dissipation capacity and reducing damage to the wall's base. The optimum distribution of yield shear force coefficients is to evenly distribute the damage at dampers over the structural height based on the cumulative plastic deformation ratio of the dissipation device. Nonlinear dynamic analysis indicates that, with a proper set of damping parameters, the wall's dynamic responses can be well controlled. Finally, based on the total plastic strain energy and its trend through the height of the buildings, a prediction equation is suggested.

RVEGA SMC를 이용한 이중 탱크의 수위 제어 (Control of Coupled Tank Level using RVEGA SMC)

  • 김태우;이준탁
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권1호
    • /
    • pp.104-111
    • /
    • 2000
  • It is very difficult to maintain the desired tank level without any overflow or any shortage in a dangerous shemical plant and in a cooling one. Futhermore, because its dynamics are very complicate and nonlinear, it is impossible to realize the precise control using the accurate mathematical model which can be applied to the various peration modes. Nonetheless, the sliding mode controller(SMC) is known as having the robust variable structures for the nonlinear control system with the parametric perturbations and with the rapid disturbances. But the adaptive tuning algorithms for their parameters are not satisfactory. Therefore, in this paper, a Real Variable Elitist Genetic Algorithm based Sliding Mode Controller (RVEGA SMC) for the precise control of the coupled tank level was tried. The SMC's switching parameters were optimized easily and rapidly by RVEGA. The simulation results showed that the tank level could be satisfactorily controlled without and overshoot and any steady-state error by the proposed RVEGA SMC.

  • PDF