• Title/Summary/Keyword: coupled electric field

Search Result 153, Processing Time 0.018 seconds

Analysis of Piezoelectric Ceramic Multi-layer Actuators Based on the Electro-mechanical Coupled Meshless Method (전기-기계 결합 하중을 받는 압전 세라믹 다층 작동기의 무요소 해석)

  • Kim, Hyun-Chul;Guo, Xianghua;Kim, Won-Seok;Fang, Daining;Lee, Jung-Ju
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.2
    • /
    • pp.101-108
    • /
    • 2007
  • This paper presents an efficient meshless method for analyzing cracked piezoelectric structures subjected to mechanical and electrical loading. The method employs an element free Galerkin (EFG) formulation and an enriched basic function as well as special shape functions that contain discontinuous derivatives. Based on the moving least squares (MLS) interpolation approach, The EFG method is one of the promising methods for dealing with problems involving progressive crack growth. Since the method is meshless and no element connectivity data are needed, the burdensome remeshing procedure required in the conventional finite element method (FEM) is avoided. The numerical results show that the proposed method yields an accurate near-tip stress field in an infinite piezoelectric plate containing an interior hole. Another example is to study a ceramic multilayer actuator. The proposed model was found to be accurate in the simulation of stress and electric field concentrations due to the abrupt end of an internal electrode.

Heat transfer enhancement in gas tungsten arc welding using azimuthal magnetic fields generated by external current

  • Kim, Yiseul;Lee, Jaewook;Liu, Xiaolong;Lee, Boyoung;Chang, Yunlong
    • Coupled systems mechanics
    • /
    • v.6 no.2
    • /
    • pp.113-125
    • /
    • 2017
  • This paper proposes the idea to enhance the heat transfer in Gas Tungsten Arc Welding (GTAW) by using the azimuthal magnetic field. The azimuthal magnetic field generated by the external currents makes the Lorentz force stronger, and consequently improves the heat transfer by the faster flow movement. The enhanced heat transfer might improve the welding performance by increasing the temperature at the workpiece. To validate the proposed idea, a two-dimensional axi-symmetric model of GTAW is built, and the multiphysics simulation of GTAW is carried out. As the analysis result, the distributions of electric current, electromagnetic fields, arc flow velocity, and temperature are investigated. Then, the proposed idea for heat transfer enhancement is validated by comparing the Lorentz force, flow velocity, and temperature distribution with and without azimuthal magnetic fields.

Design of Permanent Magnet Type Wind Power Generators for Cogging Torque Reduction with Optimum Pole Arc Pitch Ratio (코깅토크 저감을 위한 최적 극호비를 갖는 영구자석형 풍력발전기의 설계)

  • Jang, Seok-Myeong;Kim, Jin-Soon;Ko, Kyoung-Jin;Choi, Jang-Young;Yoon, Gi-Gab
    • Proceedings of the KIEE Conference
    • /
    • 2009.04b
    • /
    • pp.38-40
    • /
    • 2009
  • In order to achieve a gearless construction of the wind energy conversion system(WECS), a low-speed generator should be used. Of the various candidate machine types, radial-field, multi-pole, permanent magnet, synchronous machines may be used for low-speed applications. So, this paper deals with the design of direct-coupled, multi-pole radial field machines with permanent magnet(PM) excitation for wind power applications for cogging torque reduction through the determination of optimum pole arc/pitch ratio. On the basis of an equivalent magnetic circuit method(EMCM) and a space harmonic method(SHM), an initial design is performed considering restricted conditions. And then, a detailed design is made using a non-linear finite element analyses(FEA). Finally, test results concerning generating characteristics are given to confirm the validation of the design.

  • PDF

Measurement and Modeling of Personal Exposure to the Electric and Magnetic Fields in the Vicinity of High Voltage Power Lines

  • Tourab, Wafa;Babouri, Abdesselam
    • Safety and Health at Work
    • /
    • v.7 no.2
    • /
    • pp.102-110
    • /
    • 2016
  • Background: This work presents an experimental and modeling study of the electromagnetic environment in the vicinity of a high voltage substation located in eastern Algeria (Annaba city) specified with a very high population density. The effects of electromagnetic fields emanating from the coupled multi-lines high voltage power systems (MLHV) on the health of the workers and people living in proximity of substations has been analyzed. Methods: Experimental Measurements for the Multi-lines power system proposed have been conducted in the free space under the high voltage lines. Field's intensities were measured using a referenced and calibrated electromagnetic field meter PMM8053B for the levels 0 m, 1 m, 1.5 m and 1.8 m witch present the sensitive's parts as organs and major functions (head, heart, pelvis and feet) of the human body. Results: The measurement results were validated by numerical simulation using the finite element method and these results are compared with the limit values of the international standards. Conclusion: We project to set own national standards for exposure to electromagnetic fields, in order to achieve a regional database that will be at the disposal of partners concerned to ensure safety of people and mainly workers inside high voltage electrical substations.

Electroconvective Instability on Undulated Ion-selective Surface (파상형 이온 선택 표면상의 전기와류 불안정성)

  • Lee, Hyomin
    • Korean Chemical Engineering Research
    • /
    • v.57 no.5
    • /
    • pp.735-742
    • /
    • 2019
  • In this work, the electrokinetic interactions between the undulated structure of an ion-selective membrane and electroconvective instability has been studied using numerical analysis. Using finite element method, electric field-ionic species transport-flow field were analyzed by fully-coupled manner. Through the numerical study, the Dukhin's mode as the mechanism of undulated surface for the electroconvective instability were proven. The Dukhin's mode which competes with Rubinstein's mode has roles of (i) decreasing transition voltage to overlimiting regime and (ii) non-linearly increasing of overlimiting current. Also, (iii) the mixing efficiency is enhanced by removal mechanism of high-frequency Fourier mode of the electroconvective instability. Conclusively, the undulated ion-selective surface would provide energy-efficient mechanism for ion-selective transport systems such as electrodialysis, electrochemical battery, etc.

Design of an Inductively Coupled Plasma Source with Consideration of Electrical Properties and its Practical Issues (전기적 특성을 고려한 ICP Source 설계)

  • Lee, S.W.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.3
    • /
    • pp.176-185
    • /
    • 2009
  • The realization and the performance of ICP source are strongly affected by its electrical impedance and the electric/magnetic field distribution. The ICP source impedance is determined by the antenna impedance and the plasma one. It is preferred to keep the imaginary impedance between -100 ohm to 100 ohm, since it should be avoided the high voltage formation on the antenna and abrupt impedance variation during the thin film process. The plasma uniformity is affected by the electric and magnetic field which is formed by the antenna current and voltage. The influence of azimuthal symmetry are shown by the electromagnetic simulation and the measurement result of plasma density. The radial uniformity can be controlled by locating the concentric antennas which have different diameters. The power distribution ratio and its control method are presented in the case of parallel antenna connections.

Analysis on Temperature Distribution and Current-Carrying Capacity of GIL Filled with Fluoronitriles-CO2 Gas Mixture

  • Chen, Geng;Tu, Youping;Wang, Cong;Cheng, Yi;Jiang, Han;Zhou, Hongyang;Jin, Hua
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2402-2411
    • /
    • 2018
  • Fluoronitriles-$CO_2$ gas mixtures are promising alternatives to $SF_6$ in environmentally-friendly gas-insulated transmission lines (GILs). Insulating gas heat transfer characteristics are of major significance for the current-carrying capacity design and operational state monitoring of GILs. In this paper, a three-dimensional calculation model was established for a GIL using the thermal-fluid coupled finite element method. The calculated results showed close agreement with experimentally measured data. The temperature distribution of a GIL filled with the Fluoronitriles-$CO_2$ mixture was obtained and compared with those of GILs filled with $CO_2$ and $SF_6$. Furthermore, the effects of the mixture ratio of the component gases and the gas pressure on the temperature rise and current-carrying capacity of the GIL were analyzed. Results indicated that the heat transfer performance of the Fluoronitriles-$CO_2$ gas mixture was better than that of $CO_2$ but worse than that of $SF_6$. When compared with $SF_6$, use of the Fluoronitriles-$CO_2$ gas mixture caused a reduction in the GIL's current-carrying capacity. In addition, increasing the Fluoronitriles gas component ratio or increasing the pressure of the insulating gas mixture could improve the heat dissipation and current-carrying capacity of the GIL. These research results can be used to design environmentally-friendly GILs containing Fluoronitriles-$CO_2$ gas mixtures.

Electromagnetic Transmission through Slits in Two Adjacent Conducting Parallel-Plates (근접하는 도체 평행 평판의 슬릿을 통한 전자파 투과)

  • Lee, Jong-Ig;Ko, Ji-Hwan;Cho, Young-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.1
    • /
    • pp.83-90
    • /
    • 2009
  • In this paper, the problem of electromagnetic transmission through slits in two parallel conducting plates which separate two half spaces is considered. The coupled integral equations for the electric field distributions over the slits are developed for the case that the TM polarized plane wave is incident on the slit and solved by the method of moments. The transmitted power beyond the slit-perforated conducting parallel plates is computed in order to check the variations of the coupled power through slits against some parameters such as the incident angle of the TM polarized wave, slit width, lateral distance between two slits, and distance between the conducting plates. When the lateral distance between two slits approaches near the multiples of half wavelengths, the transmission resonance (maximum power transmission) is observed. If the slit width in the incident side is narrow and the distance between conducting plates is small compared to the wavelength, the maximum of transmitted power is observed to be nearly independent of the incident angle and slit width. In addition, the mechanism of the transmission resonance in the present geometry is explained using a simplified geometry and its equivalent circuit.

Analysis of coupled electro-mechanical system by using a nine-node assumed strain shell element (9 절점 가정변형률 쉘 요소를 이용한 전기-기계연성 시스템 해석)

  • Lee, Sang Gi;Park, Hun Cheol;Yun, Gwang Jun;Jo, Chang Min
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.2
    • /
    • pp.25-34
    • /
    • 2003
  • In the present paper, formulation of a nine-node assumed strain shell element is modified and extended for analysis of actuator embedded/attached structures. The shell element can alleviate locking and has sic DOFs per node by discarding assumption of no thickness change. In modeling of the physicalquantities, we have assumed linear strain field through the whole thickness direction. The electric and mechanical quantities have been coupled through the constitutive equations. Unlike typical shell element, the present shell element allows thickness change. Thus, three-dimensional piezoelasticity can be accurately simulated. Base on the formulation, a finite element program is generated and the code is validated by solving numerical examples. The results from the present work are well agreed with those from other references.

The Frequency Characteristics of Electromagnetic Waves and Discharge Phenomena Caused by Polluted Condition of Solide Insulator Surface (고체절연체표면의 오염상태에 따른 방전현상과 방사전자파의 주파수 특성)

  • 김충년;박원주;이광식;이동인;김인식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.4
    • /
    • pp.43-50
    • /
    • 2001
  • In this paper, the discharge phenomena and electromagnetic waves caused by discharge with insertion of a solid insulator and flame between sphere-sphere electrodes in air ware investigated. The surface discharge light and patterns of flame generated on a solid insulator surface were observed by using a CCD(Charged Coupled Device) camera. Also, the radiated electromagnetic waves were measured by using a biconical antenna and a spectrum analyzer. The surface discharge light generated on the solid insulator surface was larger and the size of flame was smaller by increasing allied voltages. Also, voltage distortion by voltage drop was strongly revealed when a insulator surface was polluted. When a solid insulator surface was not polluted, the electric field stength of electromagnetic waves was 10∼17[dBuV/m] higher than a polluted solide insulator, and 5∼9[dBuV/m] higher than a polluted solide insulator and flame.

  • PDF