• Title/Summary/Keyword: counting

Search Result 1,963, Processing Time 0.029 seconds

A Suggestion for Counting Efficiency Management of the Automation Instrument (자동화장비 계측효율 관리적 측정방법 제안)

  • Park, Jun Mo;Kim, Han Chul;Choi, Seung Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.105-111
    • /
    • 2018
  • Purpose Quality control of instrument takes up a large part in the Radioimmunoassays. The gamma-ray instrument, which is one of the important instruments in the laboratory, observes the condition and performance of instrument and performs quality control of the instrument by measuring the Normalization, Calibration, Background and etc. However, there are some automation instruments which can't measure the counting efficiency of gamma-ray meters, resulting in insufficient management in terms of performance evaluation of gamma-ray meters. Therefore, the purpose of this paper is to manage the quality control continuously and regularly by suggesting how to measure the counting efficiency of gamma-ray instruments. Materials and Methods In case of a comparative measurement method to a gamma-ray instrument dedicated to nuclear medical examination, the CPM and counting efficiency can be obtained after the measurement of normalization by inserting the I-125 $200{\mu}L$(CPM 50,000~500,000) into the test tube. With this CPM and counting efficiency values, it's possible to calculate the measurement of the DPM value and count the CPM from the automation instrument from the same source, and enter the DPM to calculate the counting efficiency using a comparative measurement method. Another method is to calculate the counting efficiency by estimating the half life using the radiation source information of the tracer in B test reagents of company A. Results According to the calculation formula using the DPM obtained by counting the normalization of gamma-ray meters, the detection efficiency was 75.16% for Detector 1, 76.88% for Detector 2, 77.13% for Detector 3, 75.36% for Detector 4 and 73.2% for Detector 5 respectively. Using another calculation formula estimated from the shelf life, the data of the detection efficiency from Detector 1 to Detector 5 were 74.9%, 75.1%, 76.5%, 74.9% and 73.2% respectively. Conclusion Although the accuracy of counting efficiencies of both methods are insufficient, this is considered to be useful for ongoing management of quality control if counting efficiency is managed after setting the acceptable ranges. For example, if the measurement efficiency is set to 70% or higher, the allowed %difference between measurements is within 3% and the %difference with the detector wall is set within 5%.

Automated Cell Counting Method for HeLa Cells Image based on Cell Membrane Extraction and Back-tracking Algorithm (세포막 추출과 역추적 알고리즘 기반의 HeLa 세포 이미지 자동 셀 카운팅 기법)

  • Kyoung, Minyoung;Park, Jeong-Hoh;Kim, Myoung gu;Shin, Sang-Mo;Yi, Hyunbean
    • Journal of KIISE
    • /
    • v.42 no.10
    • /
    • pp.1239-1246
    • /
    • 2015
  • Cell counting is extensively used to analyze cell growth in biomedical research, and as a result automated cell counting methods have been developed to provide a more convenient and means to analyze cell growth. However, there are still many challenges to improving the accuracy of the cell counting for cells that proliferate abnormally, divide rapidly, and cluster easily, such as cancer cells. In this paper, we present an automated cell counting method for HeLa cells, which are used as reference for cancer research. We recognize and classify the morphological conditions of the cells by using a cell segmentation algorithm based on cell membrane extraction, and we then apply a cell back-tracking algorithm to improve the cell counting accuracy in cell clusters that have indistinct cell boundary lines. The experimental results indicate that our proposed segmentation method can identify each of the cells more accurately when compared to existing methods and, consequently, can improve the cell counting accuracy.

Vision-based Potato Detection and Counting System for Yield Monitoring

  • Lee, Young-Joo;Kim, Ki-Duck;Lee, Hyeon-Seung;Shin, Beom-Soo
    • Journal of Biosystems Engineering
    • /
    • v.43 no.2
    • /
    • pp.103-109
    • /
    • 2018
  • Purpose: This study has been conducted to develop a potato yield monitoring system, consisting of a segmentation algorithm to detect potatoes scattered on a soil surface and a counting system to count the number of potatoes and convert the data from two-dimensional images to masses. Methods: First, a segmentation algorithm was developed using top-hat filtering and processing a series of images, and its performance was evaluated in a stationary condition. Second, a counting system was developed to count the number of potatoes in a moving condition and calculate the mass of each using a mass estimation equation, where the volume of a potato was obtained from its two-dimensional image, and the potato density and a correction factor were obtained experimentally. Experiments were conducted to segment potatoes on a soil surface for different potato sizes. The counting system was tested 10 times for 20 randomly selected potatoes in a simulated field condition. Furthermore, the estimated total mass of the potatoes was compared with their actual mass. Results: For a $640{\times}480$ image size, it took 0.04 s for the segmentation algorithm to process one frame. The root mean squared deviation (RMSD) and average percentage error for the measured mass of potatoes using this counting system were 12.65 g and 7.13%, respectively, when the camera was stationary. The system performance while moving was the best in L1 (0.313 m/s), where the RMSD and percentage error were 6.92 g and 7.79%, respectively. For 20 newly prepared potatoes and 10 replication measurements, the counting system exhibited a percentage error in the mass estimation ranging from 10.17-13.24%. Conclusions: At a travel speed of 0.313 m/s, the average percentage error and standard deviation of the mass measurement using the counting system were 12.03% and 1.04%, respectively.

A Study of Counting Ability of Mathematical Low Achievers in Low Grades of Elementary School (초등학교 저학년 수학부진아의 수세기 능력 연구)

  • Kim, Soo-Mi
    • School Mathematics
    • /
    • v.12 no.2
    • /
    • pp.137-150
    • /
    • 2010
  • This study has planned to understand the counting ability of mathematical low achievers(MLAs) in low grades of elementary school. For this, four MLAs of second graders were chosen as a experimental group and four MLAs of fourth graders and two mid-achievers of second grades were chosen as a comparison group. Every students were individually interviewed and their data were analyzed with three respects: accuracy, speed, efficiency. The results are the following three. First, the experimental group is still not used to counting. They counted slowly, made many mistakes and errors, and used inefficient strategies during counting. Second, It is hard to expect natural improvement of their counting performance as growing up. Finally, the explicit correlation between counting ability and arithmetic ability is not drown in this study, but the possibility still remains. These results tell us that we need to stress counting activity to MLAs when they are low graders.

  • PDF

Pedestrian Counting System based on Average Filter Tracking for Measuring Advertisement Effectiveness of Digital Signage (디지털 사이니지의 광고효과 측정을 위한 평균 필터 추적 기반 유동인구 수 측정 시스템)

  • Kim, Kiyong;Yoon, Kyoungro
    • Journal of Broadcast Engineering
    • /
    • v.21 no.4
    • /
    • pp.493-505
    • /
    • 2016
  • Among modern computer vision and video surveillance systems, the pedestrian counting system is a one of important systems in terms of security, scheduling and advertising. In the field of, pedestrian counting remains a variety of challenges such as changes in illumination, partial occlusion, overlap and people detection. During pedestrian counting process, the biggest problem is occlusion effect in crowded environment. Occlusion and overlap must be resolved for accurate people counting. In this paper, we propose a novel pedestrian counting system which improves existing pedestrian tracking method. Unlike existing pedestrian tracking method, proposed method shows that average filter tracking method can improve tracking performance. Also proposed method improves tracking performance through frame compensation and outlier removal. At the same time, we keep various information of tracking objects. The proposed method improves counting accuracy and reduces error rate about S6 dataset and S7 dataset. Also our system provides real time detection at the rate of 80 fps.

An Intercomparison of Counting Efficiency and the Performance of Two Whole-Body Counters According to the Type of Phantom

  • Pak, Minjung;Yoo, Jaeryong;Ha, Wi-Ho;Jin, Young-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.274-281
    • /
    • 2016
  • Background: Whole-body counters are widely used to evaluate internal contamination of the internal presence of gamma-emitting radionuclides. In internal dosimetry, it is a basic requirement that quality control procedures be applied to verify the reliability of the measured results. The implementation of intercomparison programs plays an important role in quality control, and the accuracy of the calibration and the reliability of the results should be verified through intercomparison. In this study, we evaluated the reliability of 2 whole-body counting systems using 2 calibration methods. Materials and Methods: In this study, 2 whole-body counters were calibrated using a reference male bottle manikin absorption (BOMAB) phantom and a Radiation Management Corporation (RMC-II) phantom. The reliability of the whole-body counting systems was evaluated by performing an intercomparison with International Atomic Energy Agencyto assess counting efficiency according to the type of the phantom. Results and Discussion: In the analysis of counting efficiency using the BOMAB phantom, the performance criteria of the counters were satisfied. The relative bias of activity for all radionuclides was -0.16 to 0.01 in the Fastscan and -0.01 to 0.03 in the Accuscan. However, when counting efficiency was analyzed using the RMC- II phantom, the relative bias of $^{241}Am$ activity was -0.49 in the Fastscan and 0.55 in the Accuscan, indicating that its performance criteria was not satisfactory. Conclusion: The intercomparison process demonstrated the reliability of whole-body counting systems calibrated with a BOMAB phantom. However, when the RMC-II phantom was used, the accuracy of measurements decreased for low-energy nuclides. Therefore, it appears that the RMC-II phantom should only be used for efficiency calibration for high-energy nuclides. Moreover, a novel phantom capable of matching the efficiency of the BOMAB phantom in low-energy nuclides should be developed.

Mechanism of Quenching by Dimethylanilines in Liquid Scintillation Counting (Liquid Scintillation Counting 에서의 Dimethylaniline 에 依한 消光機構)

  • Lee, Ik-Choon
    • Journal of the Korean Chemical Society
    • /
    • v.8 no.2
    • /
    • pp.43-46
    • /
    • 1964
  • Quenching constants, q, determined for N,N-dimethylanilines by liquid scintillation counting indicate that the quenching involves an energy transfer process to these compounds causing strong n-${\pi}$ interaction within the quencher molecule, which is then followed by an non-radiative degradation of the excitation energy to ground state.

  • PDF

A Comparative Analysis on Multiple Authorship Counting for Author Co-citation Analysis (저자동시인용분석을 위한 복수저자 기여도 산정 방식의 비교 분석)

  • Lee, Jae Yun;Chung, EunKyung
    • Journal of the Korean Society for information Management
    • /
    • v.31 no.2
    • /
    • pp.57-77
    • /
    • 2014
  • As co-authorship has been prevalent within science communities, counting the credit of co-authors appropriately is an important consideration, particularly in the context of identifying the knowledge structure of fields with author-based analysis. The purpose of this study is to compare the characteristics of co-author credit counting methods by utilizing correlations, multidimensional scaling, and pathfinder networks. To achieve this purpose, this study analyzed a dataset of 2,014 journal articles and 3,892 cited authors from the Journal of the Architectural Institute of Korea: Planning & Design from 2003 to 2008 in the field of Architecture in Korea. In this study, six different methods of crediting co-authors are selected for comparative analyses. These methods are first-author counting (m1), straight full counting (m2), and fractional counting (m3), proportional counting with a total score of 1 (m4), proportional counting with a total score between 1 and 2 (m5), and first-author-weighted fractional counting (m6). As shown in the data analysis, m1 and m2 are found as extreme opposites, since m1 counts only first authors and m2 assigns all co-authors equally with a credit score of 1. With correlation and multidimensional scaling analyses, among five counting methods (from m2 to m6), a group of counting methods including m3, m4, and m5 are found to be relatively similar. When the knowledge structure is visualized with pathfinder network, the knowledge structure networks from different counting methods are differently presented due to the connections of individual links. In addition, the internal validity shows that first-author-weighted fractional counting (m6) might be considered a better method to author clustering. Findings demonstrate that different co-author counting methods influence the network results of knowledge structure and a better counting method is revealed for author clustering.

Report on Two Cases of Treatment of Anxiety Disorder with Panic Attacks-on the Basis of Breath-Counting Meditation (Anapanasati)

  • Yoo, Song-Wun;Kim, Dong-Uk;Park, Se-Jin
    • Journal of Oriental Neuropsychiatry
    • /
    • v.26 no.1
    • /
    • pp.1-10
    • /
    • 2015
  • Objectives: The purpose of this study was to evaluate the effect of breath-counting meditation on anxiety disorder patients with panic attack. Methods: Two anxiety disorder patients with panic attack were treated with Breath-counting Meditation, acupunctures, and herb-medications. The patients have been predicted for anxiety disorder with panic attack through Dignosis and Statistical Manual (DSM-IV), Panic Disorder Severity Scale (PDSS), BDI (Beck Depression Inventory), and BAI (Beck Anxiety Inventory) on their 1st and 6th treatments. Results: After the treatments, both the physical and psychological symptoms have decreased. Conclusions: This study suggests that the breath-counting meditation is an effective way for treating patients who are suffering from anxiety disorder with panic attack.

Accuracy of Intersection Counting Method in Measurement of Fiber Orientation Angle Distribution Using Image Processing (화상처리에 의한 섬유배향각 분포측정에 있어서 교차점합산법의 정밀도)

  • 이상동;박준식;이동기;한길영;김이곤
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.12
    • /
    • pp.97-105
    • /
    • 1998
  • The fiber oriented condition inside fiber reinforced composite material is a basic factor of mechanical properties of composite materials. It is very important to meausure the fiber orientation angle for the determination of molding conditions, mechanical characteristics, and the design of composite materials. In the work, the fiber orientation distribution of simulation figure plotted by PC is measured using image processing in order to examine the accuracy of intersection counting method. The fiber orientation function measured by intersection counting method using image processing is compared with the calculated fiber orientation function. The results show that the measured value of fiber orientation function using intersection counting method is lower than the calculated value, because the number of intersection between the scanning line and the fiber with smaller fiber aspect ratio is counted less than with larger fiber aspect ratio.

  • PDF